Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Calibration of High Frequency MEMS Microphones

Understanding and controlling aircraft noise is one of the major research topics of the NASA Fundamental Aeronautics Program. One of the measurement technologies used to acquire noise data is the microphone directional array (DA). Traditional direction array hardware, consisting of commercially available condenser microphones and preamplifiers can be too expensive and their installation in hard-walled wind tunnel test sections too complicated. An emerging micro-machining technology coupled with the latest cutting edge technologies for smaller and faster systems have opened the way for development of MEMS microphones. The MEMS microphone devices are available in the market but suffer from certain important shortcomings. Based on early experiments with array prototypes, it has been found that both the bandwidth and the sound pressure level dynamic range of the microphones should be increased significantly to improve the performance and flexibility of the overall array. Thus, in collaboration with an outside MEMS design vendor, NASA Langley modified commercially available MEMS microphone as shown in Figure 1 to meet the new requirements. Coupled with the design of the enhanced MEMS microphones was the development of a new calibration method for simultaneously obtaining the sensitivity and phase response of the devices over their entire broadband frequency range. Over the years, several methods have been used for microphone calibration. Some of the common methods of microphone calibration are Coupler (Reciprocity, Substitution, and Simultaneous), Pistonphone, Electrostatic actuator, and Free-field calibration (Reciprocity, Substitution, and Simultaneous). Traditionally, electrostatic actuators (EA) have been used to characterize air-condenser microphones for wideband frequency ranges; however, MEMS microphones are not adaptable to the EA method due to their construction and very small diaphragm size. Hence a substitution-based, free-field method was developed to calibrate these microphones at frequencies up to 80 kHz. The technique relied on the use of a random, ultrasonic broadband centrifugal sound source located in a small anechoic chamber. Phase calibrations of the MEMS microphones were derived from cross spectral phase comparisons between the reference and test substitution microphones and an adjacent and invariant grazing-incidence 1/8-inch standard microphone.

Shams, Qamar A.↗

Stereo Imaging Velocimetry Technique Using Standard Off-the-Shelf CCD Cameras

Stereo imaging velocimetry is a fluid physics technique for measuring three-dimensional (3D) velocities at a plurality of points. This technique provides full-field 3D analysis of any optically clear fluid or gas experiment seeded with tracer particles. Unlike current 3D particle imaging velocimetry systems that rely primarily on laser-based systems, stereo imaging velocimetry uses standard off-the-shelf charge-coupled device (CCD) cameras to provide accurate and reproducible 3D velocity profiles for experiments that require 3D analysis. Using two cameras aligned orthogonally, we present a closed mathematical solution resulting in an accurate 3D approximation of the observation volume. The stereo imaging velocimetry technique is divided into four phases: 3D camera calibration, particle overlap decomposition, particle tracking, and stereo matching. Each phase is explained in detail. In addition to being utilized for space shuttle experiments, stereo imaging velocimetry has been applied to the fields of fluid physics, bioscience, and colloidal microscopy.

McDowell, Mark↗

Aperture-synthesis interferometry at optical wavelengths

The prospects for applying aperture-synthesis interferometry to the optical domain are reviewed. The radio examples such as the VLA provide a model, since the concepts are equally valid for radio and optical wavelengths. If scientific problems at the milliarc-second resolution level (or better) are to be addressed, a space-based optical array seems to be the only practical alternative, for the same reasons that dictated array development at radio wavelengths. One concept is examined, and speculations are offered concerning the prospects for developing real systems. Phase-coherence is strongly desired for a practical array, although self-calibration and phase-closure techniques allow one to relax the restriction on absolute phase stability. The design of an array must be guided by the scientific problems to be addressed.

Burke, Bernard F.↗

EOS Moderate Resolution Imaging Spectroradiometer - Phase C/D status and comments on calibration and georeferencing approaches

The Moderate Resolution Imaging Spectroradiometer-Nadir (MODIS-N) is a key observing instrument to be flown on the Earth Observing System (EOS). The MODIS-N is being built under contract to NASA by the Santa Barbara Research Center. MODIS-N is a 36-band instrument with bands chosen in the visible through the emitted thermal IR part of the electromagnetic spectrum to observe key features of the Earth's land and ocean surfaces plus the properties of clouds and other constituents in the troposphere. To provide improved radiometric accuracy, several on-board approaches are used to monitor the calibration of the instrument. The calibration accuracy requirements are 5 percent absolute in the reflected solar radiation observations, 2 percent relative to the sun, and 1 percent absolute in the emitted thermal IR. Requirements for georeferencing of observations are still under study. At the present time, it appears that MODIS-N pixels can be georeferenced to better than 500 meters based on the EOS pointing knowledge capabilities.

Salomonson, Vincent V.↗

Evaluation of Methods for In-Situ Calibration of Field-Deployable Microphone Phased Arrays

Current field-deployable microphone phased arrays for aeroacoustic flight testing require the placement of hundreds of individual sensors over a large area. Depending on the duration of the test campaign, the microphones may be required to stay deployed at the testing site for weeks or even months. This presents a challenge in regards to tracking the response (i.e., sensitivity) of the individual sensors as a function of time in order to evaluate the health of the array. To address this challenge, two different methods for in-situ tracking of microphone responses are described. The first relies on the use of an aerial sound source attached as a payload on a hovering small Unmanned Aerial System (sUAS) vehicle. The second relies on the use of individually excited ground-based sound sources strategically placed throughout the array pattern. Testing of the two methods was performed in microphone array deployments conducted at Fort A.P. Hill in 2015 and at Edwards Air Force Base in 2016. The results indicate that the drift in individual sensor responses can be tracked reasonably well using both methods. Thus, in-situ response tracking methods are useful as a diagnostic tool for monitoring the health of a phased array during long duration deployments.

Humphreys, William M.↗

Calibration Results for the AXAF Flux Contamination Monitor

The Flux Contamination Monitor (FCM) on the Advanced X-ray Astrophysics Facility (AXAF) serves the purposes of transfering the absolute flux calibration from the ground calibration at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center to operation on orbit and of detecting any changes in molecular contamination of the High Resolution Mirror Assembly (HRMA) between ground calibration and the post-launch activation phase. we describe the design, construction, and characterization of the FCM radioactive sources, and their placement on the Forward Contamination Cover (FCC). We present results from FCM measurements with the AXAF focal plane instruments, particularly the AXAF CCD Imaging Spectrometer (ACIS), during the ground calibration phase at XRCF in 1997. Finally, we describe the plans for FCM on-orbit measurements during observatory activation and the subsequent analysis.

Elsner, Ronald F.↗

PACE OCI Lunar Calibration: Initial Results

Launched in February 2024, the Ocean Color Instrument (OCI) onboard NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission has started performing its monthly lunar calibrations at ±7degreeslunar phase angle in March 2024. In this paper, we will describe the OCI lunar calibration methodology and show the results of lunar calibration events during the initial months of PACE/OCI operation. A key difference of OCI lunar calibration from heritage sensors is that the lunar disk integrated irradiance is computed from lunar pixel radiance and sampling distance instead of the instrument’s IFOV. PACE provided a near constant sweep rate during lunar calibration allowing accurate determination of OCI pixel sampling extent. OCI performs lunar calibration in baseline science mode with 282 hyperspectral bands from 315 –895 nm and 7 shortwave infrared bands(940 -2260 nm). For each OCI band, we compute the integrated lunar disk irradiance, and compare the result with a lunar irradiance model (ROLO)prediction. The early results presented here clearly show that OCI’s lunar image acquisition is working as intended and will provide accurate data for OCI’s on-orbit radiometric characterization. The hyperspectral lunar irradiances provided by OCI are expected to become a valuable data set for the evaluation of lunar irradiance models.

calibration↗

Results of the 1988 NASA/JPL airborne SAR calibration campaign

During the spring of 1988, the NASA/JPL multifrequency, multipolarization SAR (synthetic aperture radar) flew in series of calibration experiments over the Goldstone dry lake bed. An array of calibration devices was deployed, including dihedral and trihedral corner reflectors, polarimetric active radar calibrators, passive receivers, and CW (continuous wave) tone generators. The aim of the campaign was to calibrate both amplitude and phase of the resulting SAR images, over long and short time scales. The results of the analysis of the calibration data collected in the spring of 1988 are presented. Trihedral corner reflector signatures and certain image background measures are used to externally calibrate relative amplitude and phase between polarizations at a given frequency, and to calibrate across frequencies. Assessments are made of the calibration accuracy as a function of image frame position for each frequency, and the stability of the radar calibration over long and short time-scales.

Freeman, A.↗

Automatic Phasing for Active Antenna Elements

Automatic phasing system periodically interrupts antenna operation for calibration intervals and measures phase and amplitude response at each active antenna element. Using these measurements, system adjusts phase shift and possibly gain of active elements during operating intervals to give desired antenna-gain pattern.

Wu, C.↗

Development and Calibration of a Field-Deployable Microphone Phased Array for Propulsion and Airframe Noise Flyover Measurements

A new aeroacoustic measurement capability has been developed consisting of a large channelcount, field-deployable microphone phased array suitable for airframe noise flyover measurements for a range of aircraft types and scales. The array incorporates up to 185 hardened, weather-resistant sensors suitable for outdoor use. A custom 4-mA current loop receiver circuit with temperature compensation was developed to power the sensors over extended cable lengths with minimal degradation of the signal to noise ratio and frequency response. Extensive laboratory calibrations and environmental testing of the sensors were conducted to verify the design's performance specifications. A compact data system combining sensor power, signal conditioning, and digitization was assembled for use with the array. Complementing the data system is a robust analysis system capable of near real-time presentation of beamformed and deconvolved contour plots and integrated spectra obtained from array data acquired during flyover passes. Additional instrumentation systems needed to process the array data were also assembled. These include a commercial weather station and a video monitoring / recording system. A detailed mock-up of the instrumentation suite (phased array, weather station, and data processor) was performed in the NASA Langley Acoustic Development Laboratory to vet the system performance. The first deployment of the system occurred at Finnegan Airfield at Fort A.P. Hill where the array was utilized to measure the vehicle noise from a number of sUAS (small Unmanned Aerial System) aircraft. A unique in-situ calibration method for the array microphones using a hovering aerial sound source was attempted for the first time during the deployment.

Humphreys, William M., Jr.↗

Phase Screen Determination for the GeoSAR Interferometric Mapping Instrument

GeoSAR is a dual frequency airborne radar interferometric mapping instrument designed to obtain high resolution and high accuracy digital elevation models. The X-band inteferometric antennas are mounted beneath the fuselage with a separation distance of 2.6 m. Midway between the antennas along the aircraft centerline is a large fairing housing the Laser Baseline metrology System (LBMS) and Inertial Navigtion Units (INUs). The P-band antennas are mounted in wingtip pods approximately 10 m from the aircraft centerline. Multipath signals reflected from the LBMS fairing cause phase distortions corrupting the topograhic height measurements for both the X-band and P-band systems. In addition multipath off the wing affects the P-band phase measurements. In this paper we discuss a technique used to mitigate the amount of X-Band multipath and methods calibrating and correcting the phase for both X-Band and P-Band using a high accuracy DEM. Height differences between the interferometrically derived elevations and a photogrammetrically derived DEM are converted into phase differences. Multipath phase errors are sinusoidal with spatial frequency and amplitude related to the magnitude of reflection of the multipath reflection point and its distance from the interferometric antennas. These phase residuals are fitted using a Chebyshev polynomial sequence and used as a phase screen in the processor to correct the phase prior to height reconstruction. Based on the correction signal it is possible to estimate the location and magnitude of the multipath signal. This information can then be used to extend the domain of the phase screen over mapping angles not covered during the calibration passes. Keywords: SAR,interferometry,phase screen

Hensley, Scott↗

Another Technique For Calibration Of Polarimetric Radar

Inexpensive technique involves four-stage procedure where different aspects of radar system calibrated at each stage. Provides calibration of relative phase, crosstalk, relative amplitude, and absolute amplitude. Only artificial target(s) required is at least one trihedral corner reflector. Advantage of four-step calibration procedure is that one does not have to perform entire procedure if one does not need full calibration.

Van Zyl, Jakob J.↗

A Proposed Astrometric Observing Program for Densifying the ICRF in the Northern Hemisphere

The International Celestial Reference Frame (ICRF) could be of significant importance to the astronomy community for observing weak objects angularly close to ICRF sources with the phase-referencing technique. However, the current distribution of the ICRF sources is found to be largely non-uniform, which precludes the wide use of the ICRF as a catalog of calibrators for phase-referencing observations. We show that adding 150 new sources at appropriate sky locations would reduce the distance to the nearest ICRF source for any randomly-chosen location in the northern sky from up to 13 deg to up to 6 deg, close to the requirement of the phase-referencing technique. Accordingly, a set of 150 such sources, selected from the Jodrell Bank-VLA Astrometric Survey and filtered out using the Very Long Baseline Array Calibrator Survey, has been proposed for observation to the European VLBI Network (EVN) extended with additional geodetic stations. The use of the EVN is essential to this project since most of the new sources will be weaker and thus difficult to observe with standard geodetic networks.

Charlot, Patrick↗

MAESTRO1 data set calibration: The JRC approach

Calibration is a fundamental task for analysis. Therefore, the Microwave Team of the JRC Ispra has put considerable effort investigating and checking the different calibration techniques, using the data collected during the MAESTRO1 campaign. We report on this activity. First, we give an overview of the algorithms used for phase and radiometric calibration. Then, we describe the software tools that were developed to support the calibration data processing. Finally, we present and discuss the results obtained from the calibration in the test sites of Freiburg and Flevoland.

Lavalle, C.↗

The color bar phase meter: A simple and economical method for calibrating crystal oscillators

Comparison of crystal oscillators to the rubidium stabilized color burst is made easy and inexpensive by use of the color bar phase meter. Required equipment consists of an unmodified color TV receiver, a color bar synthesizer and a stop watch (a wrist watch or clock with sweep second hand may be used with reduced precision). Measurement precision of 1 x 10 to the minus 10th power can be realized in measurement times of less than two minutes. If the color bar synthesizer were commercially available, user cost should be less than $200.00, exclusive of the TV receiver. Parts cost for the color bar synthesizer which translates the crystal oscillator frequency to 3.579MHz and modulates the received RF signal before it is fed to the receiver antenna terminals is about $25.00. A more sophisticated automated version, with precision of 1 x 10 to the minus 11th power would cost about twice as much.

Davis, D. D.↗

PMT calibration for the JSNS^2-II far detector with an embedded LED system

The JSNS^2-II (the second phase of JSNS^2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. Here, this experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. The following properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector have been calibrated: PMT gain, its dependence of supplied High Voltage (HV), Peak-to-Valley (PV), and signal timing. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of the PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. To achieve a good energy resolution for physics events, a relative gain adjustment of up to 10% is required for all functioning PMTs. This will be achieved using the HV curves measured and the results of the LED calibration. The Peak-to-Valley (PV) ratio values, which distinguish the single photo-electron signal from the pedestal, are similar to those from the production company. Additionally, the precision of the PMT signal timing is measured to be 2.1 ns. This meets the event reconstruction requirement of 10 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗