Search NASA⌕ Search

SEARCH · Search NASA

Results for “photon detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specific integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifiers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verified using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

Plasma enhanced atomic layer deposition and atomic layer etching of gallium oxide using trimethylgallium

Atomic layer etching driven by self-limiting thermal reactions has recently been developed as a highly conformal and isotropic technique for low damage atomic scale material removal by sequential exposures of vapor phase reactants. Gallium oxide (Ga2O3) is currently among the materials of interest due to a large variety of applications including power electronics, solar cells, gas sensors, and photon detectors. In this study, Ga2O3 was deposited by plasma enhanced atomic layer deposition using trimethylgallium [TMG, Ga(CH3)3] and O2 plasma at a substrate temperature of 200 °C. We report a newly developed method for Ga2O3 thermal atomic layer etching, in which surface modification is achieved through HF exposure resulting in a gallium fluoride surface layer, and then removed through volatile product formation via ligand exchange with TMG. Saturation of the precursor exposure at a substrate temperature of 300 °C resulted in an etch rate of 1.0 ± 0.1 Å/cycle for amorphous Ga2O3. Uniformity and conformality of the atomic layer etching process were confirmed via atomic force microscopy with a measured surface roughness of 0.55 ± 0.05 nm that remains unchanged after etching. The use of TMG for etching may expand available precursors for atomic layer etching processes, while allowing for both etching and deposition of Ga2O3 using the same metalorganic precursor.

Hatch, Kevin A. (ORCID:0000000283118623)↗

Ion-beam-assisted growth of cesium-antimonide photocathodes

We report on the novel use of a Cs+ ion gun for an ion-beam-assisted molecular-beam-epitaxy (IBA-MBE) method to sequentially deposit Cs-Sb cathodes on room temperature substrates as opposed to the standard technique of thermal evaporation on elevated-temperature substrates. The details of the ultrahigh-vacuum chamber, the Cs+ ion source, and the growth technique are elaborated. The final quantum efficiency (QE) is reasonably good for Cs-Sb cathodes grown on two different substrates—Si (100) and strontium titanate—and is comparable to the QE of cathodes grown using thermal sources. This suggests that IBA-MBE could be a viable alternative to grow alkali-antimonides without substrate heating, paving the way for the growth of epitaxial alkali-antimonides in a more reproducible fashion, which may help improve the efficiency of photon detectors and accelerator applications that use alkali-antimonides as electron sources.

Engineering↗

Heterodyne spectrometer sensitivity limit for quantum networking

We report optical heterodyne detection-based spectrometers are attractive due to their relatively simple construction and ultrahigh resolution. Here we demonstrate a proof-of-principle single-mode optical-fiber-based heterodyne spectrometer that has picometer resolution and quantum-limited sensitivity around 1550 nm. Moreover, we report a generalized quantum limit of detecting broadband multispectral-temporal-mode light using heterodyne detection, which provides a sensitivity limit on a heterodyne detection-based optical spectrometer. We then compare this sensitivity limit to several spectrometer types and dim light sources of interest such as spontaneous parametric downconversion, Raman scattering, and spontaneous four-wave mixing. We calculate that the heterodyne spectrometer is significantly less sensitive than a single-photon detector and is unable to detect these dim light sources, except for the brightest and narrowest-bandwidth examples.

47 OTHER INSTRUMENTATION↗

First Results from BREAD: Broadband Reflector Experiment for Axion Detection

We report R&D progress, as well as first dark photon search results with BREAD - a novel dish antenna for broadband ~$\mu$eV-eV wave-dark matter detection, which allows to utilize state-of-the-art high-field solenoidal magnets. Axions are converted non-resonantly to photons on a cylindrical metallic wall parallel to an external magnetic field. These photons are then focused using a novel reflector geometry onto a state-of-the-art high-sensitive photon detector. We recently demonstrated [PRL 128 (2022) 131801] that this concept using a $\sim 10\,{\rm m}^2$ conversion area in a $\sim 10\,{\rm T}$ solenoidal magnet has the potential to discover QCD axions spanning multiple decades in mass range. In this talk we discuss progress of our first stage pilot experiments - GigaBREAD and InfraBREAD - covering different mass ranges. We show first results of a room-temperature GigaBREAD prototype and discuss upscaling to larger, cryogenic and magnetized versions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond Timing

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specifc integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verifed using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

Towards High-Efficiency Particle Detection Using Superconducting Microwire Arrays

We present a detailed study of an 8-channel $1\times1$~mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120~GeV hadron beam and 120~GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3~nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7~nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10~$\mu$m in situ spatial resolution. The results show a detection efficiency of 75\% and a time resolution of about 130~ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Wang, Christina [Fermilab]↗

Quantum enabled precision measurements of the 229Th nuclear isomer transition (final report)

The existence of the nuclear isomer transition in thorium-229 was first inferred from keV lines in the gamma spectrum of uranium-233 decay more than 40 years ago. Over the years, the value of the transition energy has been refined with indirect measurements using nuclear physics techniques, and the current evidence points to transition energy in the laser-accessible vacuum ultra-violet region of the spectrum. At the start of this project, the two best measurements of the transition energy were 7.8±0.5 eV and 8.28±0.17 eV from high precision gamma ray spectroscopy and kinetic energy of internal conversion electrons, respectively. This project aimed to reduce the uncertainty in the transition energy to 10 meV using direct calorimetric measurements of the decay energy with superconducting nanowire single photon detectors (SNSPDs). Specifically, the method that was pursued was to generate thorium-229 in the excited isomer state by the alpha decay of uranium-233, embed the excited state thorium into an SNSPD, then detect the energy released when the isomer deexcites.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards a New μ→eγ Search with the MEG II Experiment: From Design to Commissioning

The MEG experiment represents the state of the art in the search for the Charged Lepton Flavour Violating μ + →e + γ decay. With its first phase of operations at the Paul Scherrer Institut (PSI), MEG set the most stringent upper limit on the BR (μ + →e + γ) ≤ 4.2×10 –13 at 90% confidence level, imposing one of the tightest constraints on models predicting LFV-enhancements through new physics beyond the Standard Model. An upgrade of the MEG experiment, MEG II, was designed and it is presently in the commissioning phase, aiming at a sensitivity level of 6×10 –14 . The MEG II experiment relies on a series of upgrades, which include an improvement of the photon detector resolutions, brand new detectors on the positron side with better acceptance, efficiency and performances and new and optimized trigger and DAQ electronics to exploit a muon beam intensity twice as high as that of MEG (7×10 7 μ + /s). This paper presents a complete overview of the MEG II experimental apparatus and the current status of the detector commissioning in view of the physics data taking in the upcoming three years.

79 ASTRONOMY AND ASTROPHYSICS↗

Readout of Large Capacitance SiPMs by Weak Coupling to Charge Sensitive Amplifier

Large area and large capacitance silicon photomultiplier (SiPM) arrays are employed to collect scintillation light in noble liquid time projection chambers (TPC) such as DarkSide, nEXO, MEGII, protoDUNE and DUNE. Light readout using ASICs designed for operation in noble liquids is a solution for large meter-scale photon detectors. However, conventional readout requires a high voltage decoupling capacitor larger than SiPM capacitance (in the range of tens of nF) to achieve full charge transfer to the preamplifier. Here, we demonstrate a readout concept by weakly coupling (via a capacitor lower by an order of magnitude than SiPM capacitance) to a charge sensitive amplifier, LArASIC in this case, without any loss in the signal to noise ratio (S/N). The single-photoelectron detection, signal-to-noise ratio, timing resolution, and coincidence detection are experimentally characterized.

47 OTHER INSTRUMENTATION↗

Development of the detector array for photons, protons, and exotic residues

Accurate neutron capture predictions are needed in fundamental and applied science. Empirical models are constrained largely for stable nuclei, but predictions far from stability are needed. Neutron transfer in (d,p) reactions in inverse kinematics with rare isotope beams offer a means to access key aspects of the capture process. To this end, the detector array for photons, protons, and exotic residues (DAPPER) has been designed, built, tested, and used for measurement at Texas A&M University.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of nanodiamond photocathodes for MPGD-based detectors of single photons

The proposed new Electron–Ion Collider poses a technical and intellectual challenge for the detector design to accommodate the long-term diverse physics goals envisaged by the program. This requires a 4π detector system capable of reconstructing the energy and momentum of final state particles with high precision. The Electron-Ion Collider also requires identification of particles of different masses over a wide momentum range. A diverse spectrum of Particle IDentification detectors has been proposed. Of the four types of detectors for hadron identification, three are based on Ring Imaging Cherenkov Counter technologies, and one is realized by the Time of Flight method. The quest for a novel photocathode, sensitive in the far vacuum ultraviolet wavelength range and more robust than cesium iodide, motivated an R&D programme to explore nano-diamond (ND) based photocathodes, started by a collaboration between INFN and CNR Bari and INFN Trieste. Systematic measurements of the photoemission in different Ar:CH 4 and Ar:CO 2 gas mixtures with various types of ND powders and Hydrogenated ND (H-ND) powders are reported. A first study of the response of THGEMs coated with different photocathode materials is presented. Additionally, the progress of this R&D programme and the results obtained so far by these exploratory studies are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting boosted dark photons with gaseous detectors

We search for indirect signals of O ( keV ) dark matter annihilating or decaying into O ( eV ) dark photons. These dark photons will be highly boosted, predominantly transversely polarized, have decay lengths larger than the Milky Way, and can be absorbed by neutrino or dark matter experiments at a rate dependent on the photon-dark photon kinetic mixing parameter and the optical properties of the experiment. We show that current experiments cannot probe new parameter space, but future large-scale gaseous detectors with low backgrounds (i.e., CYGNUS, NEXT, PANDAX-III) may be sensitive to this signal when the annihilation cross section is especially large. Published by the American Physical Society 2024

79 ASTRONOMY AND ASTROPHYSICS↗

Improved Heralded Single-Photon Source with a Photon-Number-Resolving Superconducting Nanowire Detector

Deterministic generation of single photons is essential for many quantum information technologies. A bulk optical nonlinearity emitting a photon pair, where the measurement of one of the photons heralds the presence of the other, is commonly used with the caveat that the single-photon emission rate is constrained due to a trade-off between multiphoton events and pair emission rate. Using an efficient and low noise photon-number-resolving superconducting nanowire detector we herald, in real time, a single photon at telecommunication wavelength. We perform a second-order photon correlation g 2 ( 0 ) measurement of the signal mode conditioned on the measured photon number of the idler mode for various pump powers and demonstrate an improvement of a heralded single-photon source. We develop an analytical model using a phase-space formalism that encompasses all multiphoton effects and relevant imperfections, such as loss and multiple Schmidt modes. We perform a maximum-likelihood fit to test the agreement of the model to the data and extract the best-fit mean photon number μ of the pair source for each pump power. A maximum reduction of 0.118 ± 0.012 in the photon g 2 ( 0 ) correlation function at μ = 0.327 ± 0.007 is obtained, indicating a strong suppression of multiphoton emissions. For a fixed g 2 ( 0 ) = 7 × 10 − 3 , we increase the single pair generation probability by 25%. Our experiment, built using fiber-coupled and off-the-shelf components, delineates a path to engineering ideal sources of single photons.

Davis, Samantha I.↗

Earth-catalyzed detection of magnetic inelastic dark matter with photons in large underground detectors

Inelastic dark matter with moderate splittings, $\mathcal{O}$ (few to 150) keV, can upscatter to an excited state in the Earth, with the excited state subsequently decaying, leaving a distinctive monoenergetic photon signal in large underground detectors. The photon signal can exhibit sidereal-daily modulation, providing excellent separation from backgrounds. Using a detailed numerical simulation, we examine this process as a search strategy for magnetic inelastic dark matter with the dark matter mass near the weak scale, where the upscatter to the excited state and decay proceed through the same magnetic dipole transition operator. At lower inelastic splittings, the scattering is dominated by moderate mass elements in the Earth with high spin, especially 27 Al, while at larger splittings, 56 Fe becomes the dominant target. We show that the proposed large volume gaseous detector CYGNUS will have excellent sensitivity to this signal. Xenon detectors also provide excellent sensitivity through the inelastic nuclear recoil signal, and if a future signal is seen, we show that the synergy among both types of detection can provide strong evidence for magnetic inelastic dark matter. In the course we have calculated nuclear response functions for elements relevant for scattering in the Earth, which are publicly available on GitHub.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗