Search NASA⌕ Search

SEARCH · Search NASA

Results for “photon sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Investigation Of Prandtl-Ishlinskii Hysteresis Compensation for Deep Space Optical Communications Pointing Control

This paper studies the simulated performance of the Deep Space Optical Communication (DSOC) laser downlink pointing control system that has a pointing requirement at the sub-microradian scale. To achieve the required pointing precision, the DSOC Flight Laser Transceiver (FLT) point-ahead mirror (PAM) employs piezoelectric actuators, which are widely used in precision applications due to their high motion resolution, rapid response, and high output forces. However, a piezoelectric actuator's performance is often limited by nonlinearities in their response, most significantly hysteresis. To study the effect of hysteresis on our simulated pointing performance, an invertible hysteresis model is developed using the Classical Prantdl-Ishlinskii (CPI) method. The simulation includes models of DSOC hardware and electronic system components based on key parameters (bias, frequency response, noise), with the hysteresis modeled in the PAM piezo actuator dynamics. A Proportional-Integral controller provides feedback with measurements from two potential sources: strain gauge sensors or a photon-counting camera. To compensate for hysteresis behavior, a feedforward inverse CPI hysteresis model is implemented in the control system. Two CPI models are built using different sampling methods (uniform sampling and cosine spacing) and controller performance is compared. For the maximum command range of ±400 μrad at 1 mHz, results show that the feedforward combined with feedback control reduces output tracking error by 50% or 58% (to 0.20 or 0.38 μrad) compared to feedback control alone (from 0.40 or 0.90 μrad), corresponding to the uniform-sampled and cosine-sampled CPI models, respectively.

Marinello, Lindsey A.↗

Fiber optic interferometric sensors for aerospace applications

This paper addresses two fiber optic sensor development programs in the Photonics Laboratory, NASA Ames Research Center, one in progress and the other being initiated. The ongoing program involves development of advanced acoustic sensors for wind tunnel applications. The new undertaking involves development of a novel sensor technique for studies of aerodynamic transition from laminar to turbulent flow.

Cho, Y. C.↗

Phase Demodulation by Frequency Chirping in Coherence Microwave Photonic Interferometry

This paper presents a signal processing method to demodulate the optical interference phase of cascaded individual optical fiber intrinsic Fabry-Perot interferometric (IFPI) sensors in a coherent microwave-photonic interferometry (CMPI) distributed sensing system. The new method utilizes the chirp effect of electro-optic modulator (EOM) to create a quasi-quadrature optical interference phase shift between two adjacent pulses which correspond to two adjacent reflection points in the time domain. The phase shift can be controlled by adjusting the bias voltage that is applied to the EOM. The interference phase is calculated by elliptically fitting the phase shift. The interference phase change is proportional to the optical path difference (OPD) change of the interferometer, and the sign can be used to differentiate the increase or decrease of the OPD. The method is demonstrated for distributed strain sensing, showing good linearity, high resolution and large dynamic range.

42 ENGINEERING↗

Charge collection study with the ATLAS ITk prototype silicon strip sensors ATLAS17LS

The inner tracker of the ATLAS detector is scheduled to be replaced by a completely new silicon-based inner tracker (ITk) for the Phase-II of the CERN LHC (HL-LHC). The silicon strip detector covers the volume 40 < R < 100 cm in the radial and | z | < 300 cm in the longitudinal directions. The silicon sensors for the detector will be fabricated using the n + -on-p 6-inch wafer technology, for a total of 22,000 wafers. Here, intensive studies were carried out on the final prototype sensors ATLAS17LS fabricated by Hamamatsu Photonics (HPK). The charge collection properties were examined using penetrating 90 Sr β -rays and the ALIBAVA fast readout system for the miniature sensors of 1 cm × 1 cm in area. The samples were irradiated by protons in the 27 MeV Birmingham Cyclotron, the 70 MeV CYRIC at Tohoku University, and the 24 GeV CERN-PS, and by neutrons at Ljubljana TRIGA reactor for fluence values up to 2 × 10 15 n eq /cm 2 . The change in the charge collection with fluence was found to be similar to the previous prototype ATLAS12, and acceptable for the ITk. Sensors with two active thicknesses, 300 μ m (standard) and 240 μ m (thin), were compared and the difference in the charge collection was observed to be small for bias voltages up to 500 V. Some samples were also irradiated with gamma radiation up to 2 MGy, and the full depletion voltage was found to decrease with the dose. This was caused by the Compton electrons due to the 60 Co gamma radiation. To summarize, the design of the ATLAS17LS and technology for its fabrication have been verified for implementation in the ITk. We are in the stage of sensor pre-production with the first sensors already delivered in January of 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated quantum optical phase sensor in thin film lithium niobate

Abstract The quantum noise of light, attributed to the random arrival time of photons from a coherent light source, fundamentally limits optical phase sensors. An engineered source of squeezed states suppresses this noise and allows phase detection sensitivity beyond the quantum noise limit (QNL). We need ways to use quantum light within deployable quantum sensors. Here we present a photonic integrated circuit in thin-film lithium niobate that meets these requirements. We use the second-order nonlinearity to produce a squeezed state at the same frequency as the pump light and realize circuit control and sensing with electro-optics. Using 26.2 milliwatts of optical power, we measure (2.7 ± 0.2)% squeezing and apply it to increase the signal-to-noise ratio of phase measurement. We anticipate that photonic systems like this, which operate with low power and integrate all of the needed functionality on a single die, will open new opportunities for quantum optical sensing.

47 OTHER INSTRUMENTATION↗

Single-Photon-Sensitive HgCdTe Avalanche Photodiode Detector

The purpose of this program was to develop single-photon-sensitive short-wavelength infrared (SWIR) and mid-wavelength infrared (MWIR) avalanche photodiode (APD) receivers based on linear-mode HgCdTe APDs, for application by NASA in light detection and ranging (lidar) sensors. Linear-mode photon-counting APDs are desired for lidar because they have a shorter pixel dead time than Geiger APDs, and can detect sequential pulse returns from multiple objects that are closely spaced in range. Linear-mode APDs can also measure photon number, which Geiger APDs cannot, adding an extra dimension to lidar scene data for multi-photon returns. High-gain APDs with low multiplication noise are required for efficient linear-mode detection of single photons because of APD gain statistics -- a low-excess-noise APD will generate detectible current pulses from single photon input at a much higher rate of occurrence than will a noisy APD operated at the same average gain. MWIR and LWIR electron-avalanche HgCdTe APDs have been shown to operate in linear mode at high average avalanche gain (M > 1000) without excess multiplication noise (F = 1), and are therefore very good candidates for linear-mode photon counting. However, detectors fashioned from these narrow-bandgap alloys require aggressive cooling to control thermal dark current. Wider-bandgap SWIR HgCdTe APDs were investigated in this program as a strategy to reduce detector cooling requirements.

Huntington, Andrew↗

Long-baseline quantum sensor network as dark matter haloscope

Ultralight dark photons constitute a well-motivated candidate for dark matter. A coherent electromagnetic wave is expected to be induced by dark photons when coupled with Standard-Model photons through kinetic mixing mechanism, and should be spatially correlated within the de Broglie wavelength of dark photons. Here we report the first search for correlated dark-photon signals using a long-baseline network of 15 atomic magnetometers, which are situated in two separated meter-scale shield rooms with a distance of about 1700 km. Both the network’s multiple sensors and the shields large size significantly enhance the expected dark-photon electromagnetic signals, and long-baseline measurements confidently reduce many local noise sources. Using this network, we constrain the kinetic mixing coefficient of dark photon dark matter over the mass range 4.1 feV-2.1 peV, which represents the most stringent constraints derived from any terrestrial experiments operating over the aforementioned mass range. Our prospect indicates that future data releases may go beyond the astrophysical constraints from the cosmic microwave background and the plasma heating.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Clinical 6 MV X-Ray Facility Photo-Neutron/Fission Interrogations with TMFD Sensors

Detection of several targets (U, Be, D2O) of interest to national security has been achieved at Purdue University’s 6 MV (~104 R/h) X-Ray clinical linear accelerator (CLINAC), from photoneutron/fission induced neutron signatures using a Centrifugally Tensioned Metastable Fluid Detector (CTMFD). Traditional neutron detection schemes were saturated and ineffective under the intense (to ~104 R/h) photon environment; however, the CTMFD sensor technology was capable of measuring the relatively insignificant (~10-12x lower intensity) neutron field produced from 6 MeV-end point X-Ray beam interactions with the CLINAC components and surroundings. This is in stark contrast to published results based on conventional belief for immeasurable neutron dose in 6 MV CLINAC facilities. Photoneutron and photofission neutron production rates were detected and analyzed at various standoffs from the isocenter, with and without special nuclear material (SNM) related targets ranging in mass from 5 g of Be, to ~0.6 kg of UO2. It was confirmed that 6 MV X-Ray photons do result in measurable neutron dose above normal cosmic background. Additionally, in threshold mode, the CTMFD operating under a tensioned metastable pressure of -5bar, enabled conclusive rejection of background photoneutrons, while enabling the rapid detection of: Be, D2O, C and U targets within seconds to minutes while operating in and around 104 R/h photon fields.

Ozerov, Stepan↗

An Ultrasensitive Hot-Electron Bolometer for Low-Background SMM Applications

We are developing a hot-electron superconducting transition-edge sensor (TES) that is capable of counting THz photons and operates at T = 0.3K. The main driver for this work is moderate resolution spectroscopy (R approx. 1000) on the future space telescopes with cryogenically cooled (approx. 4 K) mirrors. The detectors for these telescopes must be background-limited with a noise equivalent power (NEP) approx. 10(exp -19)-10(exp -20) W/Hz(sup 1/2) over the range v = 0.3-10 THz. Above about 1 THz, the background photon arrival rate is expected to be approx. 10-100/s), and photon counting detectors may be preferable to an integrating type. We fabricated superconducting Ti nanosensors with a volume of approx. 3x10(exp -3) cubic microns on planar substrate and have measured the thermal conductance G to the thermal bath. A very low G = 4x10(exp -14) W/K, measured at 0.3 K, is due to the weak electron-phonon coupling in the material and the thermal isolation provided by superconducting Nb contacts. This low G corresponds to NEP(0.3K) = 3x10(exp -19) W/Hz(sup 1/2). This Hot-Electron Direct Detector (HEDD) is expected to have a sufficient energy resolution for detecting individual photons with v > 0.3 THz at 0.3 K. With the sensor time constant of a few microseconds, the dynamic range is approx. 50 dB.

bolometers↗

A stochastic model for photon noise induced by charged particles in multiplier phototubes of the space telescope fine guidance sensors

The Space Telescope (ST) is subjected to charged particle strikes in its space environment. ST's onboard fine guidance sensors utilize multiplier phototubes (PMT) for attitude determination. These tubes, when subjected to charged particle strikes, generate spurious photons in the form of Cerenkov radiation and fluorescence which give rise to unwanted disturbances in the pointing of the telescope. A stochastic model for the number of these spurious photons which strike the photocathode of the multiplier phototube which in turn produce the unwanted photon noise are presented. The model is applicable to both galactic cosmic rays and charged particles trapped in the Earth's radiation belts. The model which was programmed allows for easy adaption to a wide range of particles and different parameters for the phototube of the multiplier. The probability density functions for photons noise caused by protons, alpha particles, and carbon nuclei were using thousands of simulated strikes. These distributions are used as part of an overall ST dynamics simulation. The sensitivity of the density function to changes in the window parameters was also investigated.

Howell, L. W.↗

Non-destructive evaluation and machine learning methods for inspection of spent nuclear fuel canisters: A state-of-the-art review

Nuclear energy is among the cleanest and most efficient energy sources currently available. The operation of nuclear power plants (NPPs) produces large amounts of high-level radioactive waste known as spent nuclear fuel (SNF). Currently, large amounts of SNF is stored in dry cask storage systems (DCSSs) for extended interim storage until a permanent disposal solution becomes available. During the extended interim storage, the DCSS, particularly the SNF canisters, may degrade and abnormal conditions may occur. Therefore, non-destructive evaluation (NDE) and machine learning (ML) approaches are necessary for inspection of SNF canisters. This paper presents a state-of-the-art review of literature by summarizing recent progress made on the applications of NDE and ML for inspection of SNF canisters. Sixteen NDE methods are examined and compared: visual inspection, ultrasonic guided waves (UGWs), laser-based approaches, acoustic emission (AE), eddy current testing (ECT), non-invasive acoustic sensing, dynamic modal testing, cosmic ray muons tomography, neutron imaging, gamma rays detection, fiber optical sensors, through-wall communications, X-ray computed tomography (CT), vibrothermography, monoenergetic photon sources, and surface acoustic wave (SAW) sensors. The technology readiness level (TRL) for each method is assessed and compared. Recent publications on ML-enhanced visual inspection, AE, non-invasive acoustic sensing, dynamic modal testing, and neutron imaging for SNF canisters are summarized and future research needs are identified. In conclusion, this review article provides a convenient reference on the state-of-the-art applications of NDE and ML methods for inspection of SNF canisters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Broadband quadrature-squeezed vacuum and nonclassical photon number correlations from a nanophotonic device

We report demonstrations of both quadrature-squeezed vacuum and photon number difference squeezing generated in an integrated nanophotonic device. Squeezed light is generated via strongly driven spontaneous four-wave mixing below threshold in silicon nitride microring resonators. The generated light is characterized with both homodyne detection and direct measurements of photon statistics using photon number–resolving transition-edge sensors. We measure 1.0(1) decibels of broadband quadrature squeezing (~4 decibels inferred on-chip) and 1.5(3) decibels of photon number difference squeezing (~7 decibels inferred on-chip). Nearly single temporal mode operation is achieved, with measured raw unheralded second-order correlations g (2) as high as 1.95(1). Multiphoton events of over 10 photons are directly detected with rates exceeding any previous quantum optical demonstration using integrated nanophotonics. These results will have an enabling impact on scaling continuous variable quantum technology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stochastic model for photon noise induced by charged particles in multiplier phototubes of the Hubble Space Telescope fine guidance sensors

The Space Telescope (ST) is subjected to charged particle strikes in its space environment. ST's onboard fine guidance sensors utilize multiplier phototubes (PMT) for attitude determination. These tubes, when subjected to charged particle strikes, generate spurious photons in the form of Cerenkov radiation and fluorescence which give rise to unwanted disturbances in the pointing of the telescope. A stochastic model for the number of these spurious photons which strike the photocathodes of the multiplier phototube which in turn produce the unwanted photon noise are presented. The model is applicable to both galactic cosmic rays and charged particles trapped in the earth's radiation belts. The model which was programmed allows for easy adaption to a wide range of particles and different parameters for the phototube of the multiplier. The probability density functions for photons noise caused by protons, alpha particles, and carbon nuclei were using thousands of simulated strikes. These distributions are used as part of an overall ST dynamics simulation. The sensitivity of the density function to changes in the window parameters was also investigated.

Howell, L. W.↗

Bio-inspired gas sensing: boosting performance with sensor optimization guided by “machine learning”

The performance of existing gas sensors often degrades in field conditions because of the loss of measurement accuracy in the presence of interferences. Thus, new sensing approaches are required with improved sensor selectivity. We are developing a new generation of gas sensors, known as multivariable sensors, that have several independent responses for multi-gas detection with a single sensor. In this study, we analyze the capabilities of natural and fabricated photonic three-dimensional (3-D) nanostructures as sensors for the detection of different gaseous species, such as vapors and non-condensable gases. We employed bare Morpho butterfly wing scales to control their gas selectivity with different illumination angles. Next, we chemically functionalized Morpho butterfly wing scales with a fluorinated silane to boost the response of these nanostructures to the vapors of interest and to suppress the response to ambient humidity. Further, we followed our previously developed design rules for sensing nanostructures and fabricated bioinspired inorganic 3-D nanostructures to achieve functionality beyond natural Morpho scales. These fabricated nanostructures have embedded catalytically active gold nanoparticles to operate at high temperatures of ≈300 °C for the detection of gases for solid oxide fuel cell (SOFC) applications. Our performance advances in the detection of multiple gaseous species with specific nanostructure designs were achieved by coupling the spectral responses of these nanostructures with machine learning (a.k.a. multivariate analysis, chemometrics) tools. Our newly acquired knowledge from studies of these natural and fabricated inorganic nanostructures coupled with machine learning data analytics allowed us to advance our design rules for sensing nanostructures toward the required gas selectivity for numerous gas monitoring scenarios at room and high temperatures for industrial, environmental, and other applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quality Assurance methodology for the ATLAS Inner Tracker strip sensor production

The production of the strip sensors for the ATLAS Inner Tracker (ITk) will start in 2020. Nearly 22,000 large area sensors will be produced over a period of about five years by Hamamatsu Photonics K.K. (HPK). The institutes involved in the sensor development and production are committed to deliver and maintain the highest quality sensors for the experiment. A Quality Assurance (QA) strategy has been prepared to be carried out during the whole production period. Once the process has been characterized as providing the required pre-irradiation specifications and the proper radiation hardness, the onus is on the manufacturer to rigidly stick to that qualified process. Still, sample testing with specific device-element structures and irradiation of devices should be implemented by the ITk sensor collaboration. A detailed irradiation and testing plan has been prepared by the ATLAS-ITk Collaboration, together with a newly designed test chip with specific structures to monitor different key technological and device parameters during the whole production. The tests and irradiations will be carried out on a sample basis. In order to have a practical methodology, samples from alternating batches will be sent for irradiations with protons, neutrons and gammas, and then tested in order to check that the characteristics remain within specifications. Here we present the detailed plan and the design and test methods for the structures in the test chip.

47 OTHER INSTRUMENTATION↗

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters↗

An airborne compatible photofragmentation two-photon laser-induced fluorescence instrument for measuring background tropospheric levels of NO, NO(x), and NO2

The operating principle, design, and performance of a two-photon LIF (TP-LIF) sensor for simultaneous measurements of NO, NO(x) (NO + NO2), and NO2 are described. In this instrument, NO is first measured by direct spectroscopic TP-LIF detection; NO2 is converted to NO by photofragmentation using an XeF excimer laser operating at 353 nm; and the resulting NO is then detected quantitatively by TP-LIF. The detection limits of the instrument are found to be 3.5 parts per trillion by volume (pptv) of NO and 10 pptv for NO2, with integration times of 2 and 6 min, respectively. The in-flight performance of the instrument was evaluated during the NASA Global Tropospheric Experiment Chemical Instrumentation Test and Evaluation 2 program in summer 1986, as reported by Gregory et al. (1990).

Sandholm, S. T.↗