Search NASA⌕ Search

SEARCH · Search NASA

Results for “planetary masses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Compact Two-Step Laser Time-Of-Flight Mass Spectrometer for In Situ Analysis of Planetary Surfaces

Two-step laser mass spectrometry (L2MS) has proved to be a powerful tool for the analysis of aromatic organics in icy planetary simulants, meteorites, asphaltenes on Earth, and returned cometary particles from the Stardust mission. L2MS employs two lasers to separate the desorption and ionization processes of laser desorption ionization into distinct steps. In the first step, an infrared laser desorbs neutrals from a solid sample surface; in the second step, an ultraviolet laser forms molecular ions within the neutral plume through a resonance-enhanced process to minimize fragment at ion of complex species. We have recently demonstrated that the L2MS technique is compatible with a compact TOF-MS that could form the center piece of a future in situ landed planetary mission emphasizing surface chemistry or astrobiology. The increased sensitivity and selectivity offered by this technique has been demonstrated in analyses of various planetary analog mixtures and meteorite powders, and representative results of these analyses will be presented.

Getty, Stephanie A.↗

Characterizing K2 Candidate Planetary Systems Orbiting Low-Mass Stars. I. Classifying Low-Mass Host Stars Observed During Campaigns 1-7

We present near-infrared spectra for 144 candidate planetary systems identified during Campaigns 1-7 of the NASA K2 Mission. The goal of the survey was to characterize planets orbiting low-mass stars, but our Infrared Telescope Facility/SpeX and Palomar/TripleSpec spectroscopic observations revealed that 49% of our targets were actually giant stars or hotter dwarfs reddened by interstellar extinction. For the 72 stars with spectra consistent with classification as cool dwarfs (spectral types K3-M4), we refined their stellar properties by applying empirical relations based on stars with interferometric radius measurements. Although our revised temperatures are generally consistent with those reported in the Ecliptic Plane Input Catalog (EPIC), our revised stellar radii are typically 0.13 solar radius (39%) larger than the EPIC values, which were based on model isochrones that have been shown to underestimate the radii of cool dwarfs. Our improved stellar characterizations will enable more efficient prioritization of K2 targets for follow-up studies.

Campaigns17 of the NASA K2 Mission↗

Planetary spacecraft as optical instrument platforms

The pointing system, telemetry rate, thermal control, power, command, and available mass of planetary spacecraft are described. A comparison of the pointing and stability capabilities of the three-axis stabilized spacecraft and the spin stabilized spacecraft is presented. The development of a hybrid spacecraft, which combines the spin and three-axis design, is examined. The attitude control and articulation system, and the instruments of the Galileo, a hybrid spacecraft, are analyzed.

Vescelus, F. E.↗

Systematic KMTNet Planetary Anomaly Search. I. OGLE-2019-BLG-1053Lb, a BuriedTerrestrial Planet

In order to exhume the buried signatures of “missing planetary caustics” in Korea Microlensing Telescope Network (KMTNet) data, we conducted a systematic anomaly search of the residuals from point-source point-lens fits, based on a modified version of the KMTNet Event Finder algorithm. This search revealed the lowest-mass-ratio planetary caustic to date in the microlensing event OGLE-2019-BLG-1053, for which the planetary signal had not been noticed before. The planetary system has a planet–host mass ratio ofq= (1.25±0.13) × 10−5. A Bayesian analysis yielded estimates of the mass of the host star, Mhost =-0.61+0.29 -0.24 Mo, the mass of its planet, Mplanet =-2.48 +1.19 -0.98 Mo, the projected planet – host separation, a^= 3.4 +0.5/-0.5 au, and the lens distance, DL =-6.8 +0.6 -0.90kpc.The discovery of this very-low-mass-ratio planet illustrates the utility of our method and opens a new window for a large and homogeneous sample to study the microlensing planet–host mass ratio function down to q∼ 10−5.

Exoplanet detection methods↗

A mass spectrometer-beam experiment for investigations of planetary atmospheres

An experimental concept for investigation of planetary atmospheres using a mass spectrometer is discussed. High atmospheric pressures are reduced to mass spectrometer operating pressures by means of differential pumping. Sampling is accomplished through the formation of a molecular beam. A flag in front of the mass spectrometer can be used to separate ambient gases from system background. Laboratory tests have confirmed the feasibility of the experiment, particularly in CO2 dominated atmospheres.

Mauersberger, K.↗

Simulation of a Miniature, Low-Power Time-of-Flight Mass Spectrometer for In Situ Analysis of Planetary Atmospheres

We are implementing nano- and micro-technologies to develop a miniaturized electron impact ionization mass spectrometer for planetary science. Microfabrication technology is used to fabricate the ion and electron optics, and a carbon nanotube (CNT) cathode is used to generate the ionizing electron beam. Future NASA planetary science missions demand miniaturized, low power mass spectrometers that exhibit high resolution and sensitivity to search for evidence of past and present habitability on the surface and in the atmosphere of priority targets such as Mars, Titan, Enceladus, Venus, Europa, and short-period comets. Toward this objective, we are developing a miniature, high resolution reflectron time-of-flight mass spectrometer (Mini TOF-MS) that features a low-power CNT field emission electron impact ionization source and microfabricated ion optics and reflectron mass analyzer in a parallel-plate geometry that is scalable. Charged particle electrodynamic modeling (SIMION 8.0.4) is employed to guide the iterative design of electron and ion optic components and to characterize the overall performance of the Mini TOF-MS device via simulation. Miniature (less than 1000 cubic centimeters) TOF-MS designs (ion source, mass analyzer, detector only) demonstrate simulated mass resolutions greater than 600 at sensitivity levels on the order of 10(exp -3) cps/molecule N2/cc while consuming 1.3 W of power and are comparable to current spaceflight mass spectrometers. Higher performance designs have also been simulated and indicate mass resolutions approximately 1000, though at the expense of sensitivity and instrument volume.

King, Todd T.↗

UV Laser Development for In Situ Planetary Lander Instruments

Mass and Raman spectrometers represent progressive analytical platforms for future in situ lander missions to explore the surface chemistry of planetary bodies across the Solar System. Europa, the Moon, and Mars are some of the primary targets for future NASA missions to search for extraterrestrial life and potentially habitable environments beyond Earth, further our understanding of the timing and formation of the Solar System and identify potentially viable economic resources such as water and/or valuable metal assets. The CORALS (Characterization of Ocean Residues And Life Signatures) and CRATER (Characterization of Regolith And Trace Economic Resources) instruments are UV laser-enabled OrbitrapTM mass spectrometers currently under development for prospective lander missions to Europa and the Moon, respectively. The Raman Mass Spectrometer (RAMS) is a dual wavelength (UV and visible) laser enabled hybrid instrument that incorporates laser desorption/ ionization mass spectrometry (LDMS) and micro-Raman microspectroscopy imaging (μRS) into a compact instrument package for multiple planetary missions to the inner and outer Solar System. The Pulse Laser Ablation Sampling and Mass Analysis (PLASMA) instrument combines a multi-wavelength laser (deep-UV to near-IR), plasma source, and collision cell with a heritage quadrupole mass spectrometer (QMS) to enable high precision trace element analyses for a future Lunar lander instrument. We report on the advancement of four compact, robust, and high technology readiness level (TRL) solid state lasers operating at wavelengths 213 nm, 266 nm, 515 nm, 532 nm and 1064 nm that serve as the sampling and ionization sources, for the CRATER, CORALS, RAMS and PLASMA investigations.

Molly Fahey↗

Multi-Pass Quadrupole Mass Analyzer

Analysis of the composition of planetary atmospheres is one of the most important and fundamental measurements in planetary robotic exploration. Quadrupole mass analyzers (QMAs) are the primary tool used to execute these investigations, but reductions in size of these instruments has sacrificed mass resolving power so that the best present-day QMA devices are still large, expensive, and do not deliver performance of laboratory instruments. An ultra-high-resolution QMA was developed to resolve N2 +/CO+ by trapping ions in a linear trap quadrupole filter. Because N2 and CO are resolved, gas chromatography columns used to separate species before analysis are eliminated, greatly simplifying gas analysis instrumentation. For highest performance, the ion trap mode is used. High-resolution (or narrow-band) mass selection is carried out in the central region, but near the DC electrodes at each end, RF/DC field settings are adjusted to allow broadband ion passage. This is to prevent ion loss during ion reflection at each end. Ions are created inside the trap so that low-energy particles are selected by low-voltage settings on the end electrodes. This is beneficial to good mass resolution since low-energy particles traverse many cycles of the RF filtering fields. Through Monte Carlo simulations, it is shown that ions are reflected at each end many tens of times, each time being sent back through the central section of the quadrupole where ultrahigh mass filtering is carried out. An analyzer was produced with electrical length orders of magnitude longer than its physical length. Since the selector fields are sized as in conventional devices, the loss of sensitivity inherent in miniaturizing quadrupole instruments is avoided. The no-loss, multi-pass QMA architecture will improve mass resolution of planetary QMA instruments while reducing demands on the RF electronics for high-voltage/high-frequency production since ion transit time is no longer limited to a single pass. The QMA-based instrument will thus give way to substantial reductions of the mass of flight instruments.

Prestage, John D.↗

Two-step Laser Time-of-Flight Mass Spectrometry to Elucidate Organic Diversity in Planetary Surface Materials.

Laser desorption/ionization time-of-flight mass spectrometry (LD-TOF-MS) holds promise to be a low-mass, compact in situ analytical capability for future landed missions to planetary surfaces. The ability to analyze a solid sample for both mineralogical and preserved organic content with laser ionization could be compelling as part of a scientific mission pay-load that must be prepared for unanticipated discoveries. Targeted missions for this instrument capability include Mars, Europa, Enceladus, and small icy bodies, such as asteroids and comets.

Europa↗

The Martian climate: Energy balance models with CO2/H2O atmospheres

Coupled equations are developed for mass and heat transport in a seasonal Mars model with condensation and sublimation of CO2 at the polar caps. Topics covered include physical considerations of planetary as mass and energy balance; effects of phase changes at the surface on mass and heat flux; atmospheric transport and governing equations; and numerical analysis.

Hoffert, M. I.↗

Effect of Nitrogen Gas on the Lifetime of Carbon Nanotube Field Emitters for Electron-Impact Ionization Mass Spectrometry

The lifetime of a patterned carbon nanotube film is evaluated for use as the cold cathode field emission ionization source of a miniaturized mass spectrometer. Emitted current is measured as a function of time for varying partial pressures of nitrogen gas to explore the robustness and lifetime of carbon nanotube cathodes near the expected operational voltages (70-100 eV) for efficient ionization in mass spectrometry. As expected, cathode lifetime scales inversely with partial pressure of nitrogen. Results are presented within the context of previous carbon nanotube investigations, and implications for planetary science mass spectrometry applications are discussed.

Getty, Stephanie A.↗

(abstract) Pluto Integrated Camera-Spectrometer (PICS): a Low Mass, Low Power Instrument for Planetary Exploration

The concept we describe is an integrated instrument (a Pluto Integrated Camera-Spectrometer -- PICS) that will perform the functions of all three optical instruments required by the Pluto Fast Flyby Mission: the near-IR spectrometer, the camera, and the UV spectrometer. This integrated approach minimizes mass and power use. It also forced us early in the conceptual design to consider integrated observational sequences and integrated power management, thus ensuring compatible duty cycles (i.e., exposure times, readout rates) to meet the composite requirements for data collection, compression, and storage. Based on flight mission experience we believe that this integrated approach will result in substantial cost savings, both in reworking instrument designs during accommodation, as well as in sequence planning and integration. Finally, this integrated payload automatically yields a cohesive mission data set, optimized for correlative analysis. The presentation will provide details of the PICS instrument design and describe the fabrication and testing of the integrated SiC structure and optics at SSG Inc. Final integration and test plans for the prototype will also be described.

Pluto↗

Systems analysis

Selenodesy experiment, data compression, Mars and Venus mass data, Earth-Moon mass ratio, orbits for three-body problem, and unbraked impact time for lunar landing mission - systems analyses

THREE-BODY PROBLEM↗