Search NASA⌕ Search

SEARCH · Search NASA

Results for “plasma instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Machine learning prediction of electron density and temperature from He I line ratios

We propose to utilize machine learning to predict the electron density, ne, and temperature, T e , from He I line intensity ratios. In this approach, training data consist of measured He I line ratios as input and ne and T e measured using other diagnostic(s) as desired output, which is a Langmuir probe in our study. Support vector machine regression analysis is, then, performed with the training data to develop a predictive model for n e and T e , separately. It is confirmed that n e and T e predicted using the developed models agree well with those from the Langmuir probe in the ranges of 0.28 × 10 18 ≤ n e (m -3 ) ≤ 3.8 × 10 18 and 3.2 ≤ T e (eV) ≤ 7.5. The developed models are, further, examined with an evaluation data, which are not included in the training data, and are found to well reproduce absolute values and radial profiles of probe-measured n e and T e .

47 OTHER INSTRUMENTATION↗

Design and implementation of a portable diagnostic system for Thomson scattering and optical emission spectroscopy measurements

A diagnostic system, which has a design goal of high-portability, has been designed at Oak Ridge National Laboratory (ORNL). This project aims at providing measurements of key plasma parameters (ne, Te, ni, Ti) for fusion-relevant devices, utilizing Thomson scattering (TS) and optical emission spectroscopy (OES). The innovative design employs mostly commercial off-the-shelf instrumentation and a traveling team of researchers to conduct measurements at various magnetic-confinement plasma devices. The TS diagnostic uses a Quantel Q-smart 1500 Nd:YAG laser with a 2ω harmonic generator to produce up to 850 mJ of 532 nm laser pulses at 10 Hz. Collection optics placed at the detection port consists of an 11 × 3 optical fiber bundle, where the TS diagnostic uses an 11 × 1 subset array of the fibers, the OES diagnostic uses another 11 fibers, and the remaining fibers are available to the host institution. The detection system is comprised of two separate IsoPlane-320 spectrometers with triple-grating turrets of various line spacing and two PI-MAX 4 intensified CCD detectors, used simultaneously to measure a broad range of ion, impurity, and electron parameters. The self-contained diagnostic package also includes a data processing and storage system. The design and initial implementation of the TS-OES diagnostic system are described. The experiments from the proof-of-principle operation of the portable package on a high density (∼2.5 × 1022 m−3) and low-temperature (∼5 eV) electrothermal arc source at ORNL are also discussed.

Kafle, N. (ORCID:000000028144787X)↗

Design and expected performance of a variable-radii sinusoidal spiral x-ray spectrometer for the National Ignition Facility

A novel high-resolution x-ray spectrometer for point-like emission sources has been developed using a crystal shape having both a variable major and a variable minor radius of curvature. This variable-radii sinusoidal spiral spectrometer (VR-Spiral) allows three common spectrometer design goals to be achieved simultaneously: 1. reduction of aberrations and improved spectral (energy) resolution, 2. reduction of source size broadening, and 3. use of large crystals to improve total throughput. The VR-Spiral concept and its application to practical spectrometer design are described in detail. This concept is then used to design a spectrometer for an extreme extended x-ray absorption fine structure experiment at the National Ignition Facility looking at the Pb L 3 absorption edge at 13.0352 keV. The expected performance of this VR-Spiral spectrometer, both in terms of energy resolution and spatial resolution, is evaluated through the use of a newly developed raytracing tool, xicsrt. Finally, the expected performance of the VR-Spiral concept is compared to that of spectrometers based on conventional toroidal and variable-radii toroidal crystal geometries showing a greatly improved energy resolution.

47 OTHER INSTRUMENTATION↗

On the relative importance of the different initial conditions that seed the electrothermal instability

Electrothermal instability is responsible for degrading numerous applications of pulsed-power technology, yet the initial conditions from which it grows are not well understood. For the first time, metal surfaces have been tracked from characterization to self-emission. This reveals no clear correlation between non-uniform thermal emissions and surface metallurgical defects or crystallographic grains, while correlations are observed with surface topography for 5N metal but not 6061 metal. Finally, for 5N metal, surfaces with average roughness as small as 5nm still admit thermal perturbations with δT/T >0.1.

42 ENGINEERING↗

Beam-pointing verification using x-ray pinhole cameras on the 60-beam OMEGA laser

On the OMEGA laser system, the beam-pointing accuracy is verified by irradiating a 4 mm diameter Au-coated spherical target with ~23 kJ of laser energy. Up to ten x-ray pinhole cameras record the x-ray emission from all 60-beam spots. A new set of algorithms has been developed to improve the accuracy of the pointing evaluation. An updated edge-finding procedure allows one to infer the center of the sphere with subpixel accuracy. A new approach was introduced to back-propagate the pixel locations on the 2D image to the 3D surface of the sphere. Furthermore, a fast Fourier transform-based de-noising method significantly improves the signal-to-noise of the data. Based on the beam-pointing analysis, hard-sphere calculations of the laser-drive illumination uniformity on the target surface and the decomposition of the illumination distribution into lower order modes (1–10) are evaluated.

47 OTHER INSTRUMENTATION↗

Detection limits for laser absorption spectroscopy of Li in laser ablation plumes

A high-sensitivity laser absorption spectroscopy (LAS) method is demonstrated for rapid and non-contact analysis of Li in solids. Glass samples with Li concentrations ranging from 1-500 ppm by mass are ablated in 5 Torr air, and time-resolved Li atomic absorption is measured using a tunable laser near 671 nm. Significant improvements in analytical performance over prior laser-induced breakdown techniques are demonstrated. Here, a single-shot limit of detection (LOD) of 180 ppb is shown for fixed wavelength operation, improving to 6 ppb with averaging over 1000 ablation shots (100 s acquisition time). Isotope-resolved Li absorption spectra are measured with a 17 ppb LOD in 40 s. Methods for optimizing LOD based on noise/averaging properties of LAS experiments in LA plumes are discussed.

(020.3260) Isotope shifts↗

CSAC observations from 2025 CHEDAR review [Slides]

Overall, the CSAC is impressed by the strong start of CHEDAR, a multi-institutional center with broader scope than its predecessor. The CSAC was impressed and energized by discussions with center students and staff; the enthusiasm for science is universal and the sense of the contribution in context to the NNSA mission is mostly understood. The Center is well positioned to build on a strong start and (1) enhance integration of code-development targeted to, and numerical design in on-going experimental campaigns, (2) focus and better tell the story of the astrophysical connection for on-going experimental campaigns, and (3) expand and deepen ties between Center students (and faculty) and the NNSA National Laboratories. Overall, the CSAC was encouraged and energized by the materials presented. Now, the Center has to recognize the need to continue growing strategically. There is abundant access to experimental facilities – is that a challenge to focused effort? The PIs will need to balance the pace of experimental campaigns and analysis and simulation so that informed progress and focused investigation can develop in each campaign. There was a clear need to connect simulations to the goals of experimental campaigns – what is the best way to cultivate that connection? Are there adequate resources in the near term to develop code capability? What is the balance between close personal mentorship and collaboration across the separate institutions that compose the Center? The CSAC feels confident that the team leading CHEDAR will find creative solution to these challenges.

47 OTHER INSTRUMENTATION↗

Methods for multiphase laser ablation analysis

Methods of liquid and solid materials analysis by laser induced ablation spectroscopy are disclosed. The liquid and solid materials are analyzed in an instrument having one pulsed laser to produce emissive plasma plumes and ablate solid material. Liquid phase samples are aerosolized before streaming to an analysis zone where they are dissociated into a plasma plume. A large number of sites within solid phase sample structures and be analyzed using a movable x-y-z stage and displayed in a chemical map.

Bol'shakov, Alexander A.↗

LBNL-BELLA Center Monoenergetic Photon Source Experiments

This document outlines measurements made by Idaho National Laboratory (INL) staff at the Berkeley Lab Laser Accelerator (BELLA) Center. Measurements of a mono-energetic Thomson photon beam were made with various INL instruments. The photon beam was generated by a laser-plasma accelerator system. This project is referred to by the name Laser Wake. Key Lawrence Berkeley National Laboratory (LBNL) personnel involved include Liona Fan-Chiang, Cameron Geddes, Anthony Gonsalves, Robert Jacob, Tobias Ostermayr, and Hai-En Tsai.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Sub-nanosecond time-resolved radiation measurement using x-ray focusing crystal spectrometers

Here, in this paper, we describe a technique using a crystal spectrometer, a silicon-diode detector, and a filtered photoconductive detector to monitor photon energies in the L-shell (0.9–1 keV) and K-shell regimes for nickel and copper hybrid X-pinch x-ray sources. The detectors, system cabling, and an 8 GHz digital oscilloscope in combination enable time resolution better than 200 ps for photoconductive detectors and 700 ps for silicon-diode detectors of the K- and L-shell radiation signals, respectively. We substantially improve the relative timing of signals obtained using the oscilloscope by using an x-ray streak camera with a crystal spectrometer to monitor the L-shell line spectra and, separately, the K-shell line spectra relative to the continuum burst to better than 17 ps time resolution. This combination of instruments enabled and validated a new method by which plasma conditions in nickel and copper X-pinches can be assessed immediately before and after the ~30 ps continuum x-ray burst produced by 370 kA hybrid X-pinches. In general, the method described here can be applied to observe otherwise highly filter-absorbed radiation in the presence of a broad spectrum of higher energy radiation by combining x-ray crystals and detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Density Implosions on OMEGA and the National Ignition Facility (NIF) (Final FY23 report for the subcontract B656484 (formerly B640112))

This final FY23 report for the subcontract B656484 (formerly B640112) “High-Density Implosions on Omega and the National Ignition Facility (NIF)” summarizes MIT’s support of LLNL experiments at OMEGA and the NIF with nuclear diagnostics, platforms and analysis, and of training PhD students. Overall, the tasks identified as Statement-Of-Work (SOW) items for FY23 were accomplished.

42 ENGINEERING↗

Novel data interpretation method for DIII-D divertor retarding field energy analyzer with 3-D particle-in-cell simulations

A novel data interpretation process that utilizes comprehensive particle-in-cell (PIC) simulations is developed for the new retarding field energy analyzer (RFEA) currently being constructed at DIII-D for the lower divertor using the Divertor Material Evaluation System. Furthermore, this probe is expected to survive a heat load of up to 100 MW/m 2 for up to 5 s and reliably measure the main ion temperature (T i ) on the divertor target ranging from 10 to 200 eV. These extreme conditions posed significant engineering limitations on the probe geometry, thus extensive validation work has been performed. The conventional fitting method for the RFEA I–V characteristics is based on a simplified 1-D model without considering the ion space charge inside the probe cavity and may not be sufficient for probes designed for the DIII-D divertor environment. In this article, a more realistic description of the particle propagation process within the RFEA cavity is achieved by including both 3-D geometric effects and ion space charge in the PIC simulations, and the capability to reconstruct the ion energy distribution functions is demonstrated with reasonable consistency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

$Z$-Pinch Interferometry Analysis With the Fourier-Based TNT Code

Here, we present the analysis of interferometry diagnostics with the user-friendly Talbot Numerical Tool (TNT), a Fourier-based postprocessing code that enables real-time assessment of plasma systems. TNT performance was explored with visible and infrared interferometry in pulsed-power-driven Z -pinch configurations to expand its capabilities beyond Talbot X-ray interferometry in the high-intensity laser environment. TNT enabled accurate electron density characterization of magnetically driven plasma flows and shocks through phase-retrieval methods that did not require data modification or masking. TNT demonstrated enhanced resolution, detecting below 4 % fringe shift, which corresponds to 8.7 × 10 15 cm –2 within 28 μ m, approaching the laser probing system limit. TNT was tested against a well-known interferometry analysis software, delivering an average resolving power nearly ten times better (~28 μ m versus ~ 210 μ m) when resolving plasma ablation features. TNT demonstrated higher sensitivity when probing sharp electron density gradients in supersonic shocks. A maximum electron areal density of 4.1 × 10 17 cm –2 was measured in the shocked plasma region, and a minimum electron density detection of ~ 1.0 × 10 15 cm –2 was achieved. When probing colliding plasma flows, the calculations of the effective adiabatic index and the associated errors were improved from γ* = 2.6 ± 1.6 – 1.4 ± 0.2 with TNT postprocessing, contributing valuable data for the interpretation of radiative transport. Additional applications of TNT in the characterization of pulsed-power plasmas and beyond are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Variable magnetic field electron spectrometer to measure hot electrons in the range of 50–460 keV

Resonance absorption (RA) occurs when a p-polarized electromagnetic wave, obliquely incident on an inhomogeneous plasma, tunnels past its turning point and resonantly excites an electron plasma wave (EPW) at the critical density. This phenomenon is important, for instance, in the direct drive approach to inertial fusion energy and is a particular example of a wider phenomenon in plasma physics known as mode conversion, which is crucial for heating magnetic fusion devices, such as tokamaks, via RF heating. Direct measurement of these RA-generated EPW accelerated hot electrons, with energy in the range of a few tens to a few hundreds of keV, is a challenging task due to the relatively low deflecting magnetic fields needed. The solution described here is a magnetic electron spectrometer (MES) with a continually changing magnetic field, lower at the entrance of the MES and gradually increasing toward the end, that enables the measurement of a wide spectral range of electrons with energies between 50 and 460 keV. Electron spectra taken in a LaserNetUS RA experiment were acquired from plasmas generated by irradiating polymer targets with the combination of an ~300 ps pulse followed by a series of ten high intensity 50–200 fs duration laser pulses from the ALEPH laser at Colorado State University. In conclusion, the high intensity beam is designed as spike trains of uneven duration and delay pulses in order to modify the RA phenomenon.

47 OTHER INSTRUMENTATION↗

Direct Observation of Plasma-Stimulated Activation of Surface Species Using Multimodal In Situ/Operando Spectroscopy Combining Polarization-Modulation Infrared Reflection-Absorption Spectroscopy, Optical Emission Spectroscopy, and Mass Spectrometry

Nonthermal plasmas (NTPs) produce reactive chemical environments, including electrons, ions, radicals, and vibrationally excited molecules, that can drive chemistry at temperatures at which such species are thermally inaccessible. There has been growing interest in the integration of conventional catalysis with reactive NTPs to promote novel chemical transformations. Unveiling the full potential of plasma-catalytic processes requires a comprehensive understanding of plasma-catalytic synergies, including characterization of plasma-catalytic surface interactions. In this work, we report on a newly designed multimodal spectroscopic instrument combining polarization-modulation infrared reflection-absorption spectroscopy (PM-IRAS), mass spectrometry, and optical emission spectroscopy (OES) for the investigation of plasma–surface interactions such as those found in plasma catalysis. In particular, this tool has been utilized to correlate plasma-phase chemistry with both surface chemistry and gas-phase products in situ (1) during the deposition of carbonaceous surface species via NTP-promoted nonoxidative coupling of methane and (2) during subsequent activation of surface deposits with an atmospheric pressure and temperature argon plasma jet on both nickel (Ni) and silicon dioxide (SiO 2 ) surfaces. For the first time, the activation of carbonaceous surface species by a NTP on Ni and SiO 2 surfaces to form hydrogen gas and C 2 hydrocarbons was directly observed, where both PM-IRAS and OES measurements suggest that they may form through different pathways. Furthermore, this unique tool for studying plasma–surface interactions could enable more rational design of plasma-stimulated catalytic processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel dual-reflection design applied for ITER core x-ray spectrometer

Here. a novel dual-reflection configuration is introduced for the International Tokamak Experimental Reactor (ITER) core x-ray spectrometer to fit the allocated space where it will be placed accompanied by moving the detectors backward to reduce the incident radiation dose. The highly oriented pyrolytic graphite, which has a mosaic structure of microscopic crystallites, is chosen for the front reflector motivated by higher x-ray throughput and stronger misalignment tolerance compared to the perfect crystal reflector. In the ITER core x-ray spectrometer, a combination of several reflector-deflected Lines of Sight (LOSs) and a direct LOS is proposed for the first time named X-Ray Crystal Spectroscopy Core (XRCS-Core). The system is optimized to observe lines from externally seeded xenon and the intrinsic tungsten impurity, meeting both port integration needs and measurement requirements. Its spectral performance is simulated using an analytical-raytracing mixed code——XRSA, showing good imaging quality with a spectral resolution higher than 8000. The XRCS-Core system is thought to be applicable in various ITER scenarios through the assessment taking into account the spectrometers’ specifications and the chosen lines’ emissivity in different plasma parameters.

47 OTHER INSTRUMENTATION↗

Active control of electron cyclotron emission radiometer channel frequencies for improved electron temperature measurements

As advanced scenarios are developed for tokamak operations, the demand for flexibility of the electron cyclotron emission (ECE) channels’ locations has increased. The tunable feature of yttrium iron garnet (YIG) filters provides this spatial flexibility. Here, we present a method of performing ECE measurements on fixed flux surfaces instead of fixed frequencies. This is achieved by adjusting YIG filters utilized in the intermediate frequency section to frequencies associated with flux surfaces in regions of interest during the discharge. Here, the key components are the application of tunable YIG filters and a control program that calculates the filter settings using flux information from real-time reconstruction equilibria (EFIT). This fast procedure facilitates T e measurements in regions of interest to investigate plasma dynamic behaviors.

47 OTHER INSTRUMENTATION↗