Search NASA⌕ Search

SEARCH · Search NASA

Results for “plug”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Fidelity-preserving enhancement of ptychography with foundational text-to-image models

Ptychographic phase retrieval enables high-resolution imaging of complex samples but often suffers from artifacts such as grid pathology and multislice crosstalk, which degrade reconstructed images. We propose a plug-and-play (PnP) framework that integrates physics model-based phase retrieval with text-guided image editing using foundational diffusion models. By employing the alternating direction method of multipliers, our approach ensures consensus between data fidelity and artifact removal subproblems, maintaining physical consistency while enhancing image quality. Artifact removal is achieved using a text-guided diffusion image editing method (LEDITS++) with a pre-trained foundational diffusion model, allowing users to specify artifacts for removal in natural language. Demonstrations on simulated and experimental datasets show significant improvements in artifact suppression and structural fidelity, validated by metrics such as peak signal-to-noise ratio and diffraction pattern consistency. This work highlights the combination of text-guided generative models and model-based phase retrieval algorithms as a transferable and fidelity-preserving method for high-quality diffraction imaging.

image editing↗

Utah FORGE: Wells 16A(78)-32 and 16B(78)-32 Stimulation Pressure and Circulation Data April, 2024

This dataset consists of all of the pressure pumping data for Utah FORGE Well16A78-32 fracturing stages, Well 16B78-32 fracturing stages, and a 9-hour circulation test which took place after all of the frac plugs were drilled out. Fracturing in the wells took place in stages from April 3rd to April 17th, while the circulation test occurred on April 27th, 2024. Data is in excel files, with ReadMe files for each of the .zip folders that detail what data is available. Also attached here is wellhead pressure data from Pason that is referred to in the ReadMe files.

15 GEOTHERMAL ENERGY↗

2015-2017 California Vehicle Survey

The 2015-2017 California Vehicle Survey of residential and commercial light-duty vehicle owners in California assessed consumer preferences for vehicles and included a targeted sample of plug-in electric vehicle (PEV) owners. Resource Systems Group conducted the survey on behalf of the California Energy Commission. In addition to economic and demographic data, the survey integrated light-duty vehicle holding and use information with vehicle choice data collected via the stated preferences survey's set of eight vehicle and fuel type choice exercises. The PEV owner survey participants provided additional data on charging behavior, electricity rates, and their main motivations for purchasing PEVs.

1Hz data↗

2019 California Vehicle Survey

The 2019 California Vehicle Survey of residential and commercial light-duty fleet owners in California assessed consumer preferences for vehicles and included a targeted sample of plug-in electric vehicle (PEV) owners. In addition to economic and demographic data, the survey integrated light-duty vehicle holding and use information with vehicle choice data, which was collected via a set of eight exercises on vehicle and fuel type choice. The PEV owner survey participants provided additional data on charging behavior, electricity rates, and their main motivations for purchasing PEVs.

1Hz data↗

Detailed Simulation Datasets Quantifying U.S. DOE VTO/HFTO R&D Benefits Across Light- to Heavy-Duty Vehicles

For more than 20 years, Argonne National Laboratory’s Vehicle & Mobility Systems Department has assessed how R&D investments by the U.S. Department of Energy’s Transportation Technologies Office and Alternative Fuels and Feedstocks Office affect vehicle energy use and cost. The analyses are performed using Autonomie, Argonne’s full-vehicle simulation tool for energy consumption, performance, and cost. The study covers five time frames ranging from present day through 2050, with more than 30 vehicle classes and applications (10 light duty and >20 medium and heavy duty), as well as six powertrain configurations (conventional, start-stop, hybrid electric vehicle, plug-in hybrid electric vehicle, battery-electric vehicle, and fuel cell electric vehicle) and five fuels (gasoline, diesel, natural gas, hydrogen, and electricity). Low and high technology uncertainty scenarios have been considered to capture a realistic range of outcomes. The resulting datasets include the assumptions used (i.e., efficiency, $/kWh), vehicle-level data (power, energy, weight, and cost), and outputs such as energy consumption, manufacturer’s suggested retail price, and total cost of ownership. These data are critical to stakeholders working in transportation, technology assessment, and long-term R&D planning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Autonomie Simulation Datasets in Support of U.S. DOT-NHTSA Advanced Vehicle Technology Research

Understanding how new vehicle technologies affect fuel economy and energy use is critical to the regulatory work performed by the U.S. Department of Transportation’s National Highway Traffic Safety Administration (NHTSA), which sets Corporate Average Fuel Economy (CAFE) standards under the Energy Policy and Conservation Act of 1975. In order to support this work, Argonne National Laboratory uses Autonomie, a full-vehicle simulation tool, to evaluate advanced powertrain architectures and their effects on vehicle energy consumption and performance. A wide range of vehicle classes has been assessed (i.e., internal combustion engine vehicles, hybrid electric vehicles, plug-in hybrid electric vehicles, battery-electric vehicles, and fuel cell electric vehicles), as well as the effects of various technology improvements such as lightweighting, aerodynamic refinements, and low-rolling-resistance tires. Simulations have been run across multiple drive cycles to capture fuel and electricity use under realistic operating conditions. The resulting datasets include detailed vehicle-level results, model assumptions, and validation reports, all of which have been made publicly available through NHTSA in support of the 2023 notice of proposed rulemaking covering light-duty vehicles for model years 2027 to 2035. These data are critical to stakeholders working in fuel economy regulation, vehicle technology assessment, and energy policy analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Downloadable Dynamometer Database (D3): Public Test Data on Advanced-Technology Vehicles

Access to high-quality, independent vehicle test data is critical to advancing energy-efficient transportation research. The Downloadable Dynamometer Database (D3) is a public repository of dynamometer test data on advanced-technology vehicles, generated at the Advanced Mobility Technology Laboratory (AMTL) at Argonne National Laboratory and hosted by the Transportation and Power Systems Division. The database has been made available to support researchers, students, and professionals engaged in energy-efficient vehicle research, development, and education. A wide range of vehicle categories has been tested (i.e., alternative fuel vehicles, conventional gasoline and diesel vehicles, all-electric vehicles, hybrid electric vehicles, and plug-in hybrid electric vehicles), as well as various drive cycles and test conditions documented in the accompanying D3 user presentation. Stakeholders can select a vehicle type, identify a vehicle of interest, and download the associated test data for use in their own analyses. Data downloaded from D3 must be accompanied by the required attribution: "This data is from the Downloadable Dynamometer Database and was generated at the Advanced Mobility Technology Laboratory (AMTL) at Argonne National Laboratory." These data are critical to vehicle modeling, validation, technology assessment, and educational use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scaling the polymerization of polyaldehydes through continuous flow synthesis

Abstract A plug flow reactor was constructed to scale the synthesis of metastable, phthalaldehyde-based polymers to achieve production rates of 1–2 kg per day. The flow-induced mixing and in-line polymerization quench and precipitation sequences resulted in improved polymer purity and long-term stability compared to the same materials made from a conventional batch process. Cryogenic rheology was used to probe the complex fluid dynamics encountered during the polymerization of PPA homopolymers. It is envisioned that this continuous flow manufacturing approach could be extended to other low ceiling temperature or aldehyde monomer systems to help implement and support a plastic circular economy. Graphical abstract

Schwartz, Jared M.↗

DE-FE0029488 - North Dakota Integrated Carbon Capture and Storage Complex Feasibility Study Public Data

Data from award DE-FE0029488 - North Dakota Integrated Carbon Capture and Storage Complex Feasibility Study performed by the Energy & Environmental Research Center including the following: - 2D Seismic {Input data, sgy files, maps, logs, and descriptors} - Core Petrophysics {Core analysis of plugs from the two stratigraphic test wells (Flemmer-1 [API 33-057-00039] and BNI-1 [API 33-065-00018])} - North Dakota Oil and Gas File No 37380 Files - North Dakota Oil and Gas File No 37672 Files - Well Testing Data {Summary of well testing methods and results from the stratigraphic test wells (Flemmer-1 and BNI-1)} Additional References: https://www.netl.doe.gov/sites/default/files/2017-12/Wesley-Peck-_Mastering-the-Subsurface_CarbonSAFE-Phase-II_August-2017-final.pdf Peck, W.D., Ayash, S.C., Klapperich, R.J., Gorecki, C.D. (2019) The North Dakota integrated carbon storage complex feasibility study, International Journal of Greenhouse Gas Control, Volume 84, 2019, Pages 47-53, https://doi.org/10.1016/j.ijggc.2019.03.001

Carbon Storage↗

Farnsworth Unit Legacy Core Data

Data set of core plug porosity and permeability from 47 wells in the Morrow sandstone, Farnsworth Unit field, Ochiltree County, Texas

Farnsworth↗

Development of the first 1 GHz niobium-tin quarter-wave cavity

Niobium-Tin (Nb3Sn) is a promising alternative to pure niobium for low-beta ion accelerators due to low RF losses even at high frequencies. At 4.5 K, the expected Bardeen-Cooper-Schrieffer resistance of Nb3Sn is a few nano-Ohms at 1 GHz, with two orders of magnitude improvement compared to pure niobium. The low Nb3Sn RF losses allow the use of higher frequency, much smaller cavities while maintaining 4.5 K operation that is compatible with cryocoolers. This work aims to demonstrate the feasibility of coating a high-frequency 1 GHz, compact quarter-wave cavity. The development of this cavity has the potential to transform low-beta ion accelerators through size reductions and by enabling the replacement of large helium cryoplants with small plug-in cryocoolers. We have designed, built, and tested a 1GHz Nb3Sn coated quarter-wave cavity. Nb3Sn coating has been performed once by vapor diffusion at Fermilab. Cryogenic cold tests show a quality factor of ~1E9 at low accelerating electric fields or ~7 times higher than the theoretical limit for pure niobium at 1GHz. This first coating does not yet meet our quality factor or gradient goals; however, we plan to continue to develop this cavity.

Zhou, Yang [Argonne]↗

Characterizing electrical demand and load diversity of low-power water and space heating appliances in US homes

Home renovation and remodeling projects can involve costly and time consuming electrical infrastructure upgrades at the household level. From the grid perspective they also lead to costly replacement of local infrastructure, such as transformers, and can add stress to the grid at peak times. The emergence of innovative, power-efficient household appliances offers a way to minimize these problems. These appliances are designed for lower power consumption, simplifying installation through standard plug-in connections, reducing the need for new electric circuits/panels/service, and minimizing the peak power demand for the home. Key examples include low-power heat pump water heaters (HPWHs) and cold climate window heat pumps that operate on standard 120V outlets. To assess the real-world impact of these solutions, we compiled and analyzed power metering data from several US field studies. This data provides insights into the effects on peak power demand of selecting lower-power appliances. Our analysis focuses on several key metrics, including the maximum power demand of individual appliances, their operational runtime, continuous operation and load diversity. While individual low-power 120V space and water heating appliances offer significant peak demand reductions compared to 240V heat pump or resistance alternatives, their longer runtimes might increase the likelihood of operation during whole-dwelling peak events, albeit at lower power levels.

Less, Brennan↗

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Radiation and Fire Resistant Polyurethane Foam in Support of Deactivation and Decommissioning [Poster]

FoamBag™ is a two-part polyurethane foam that has been down selected as a possible engineering solution for the decommissioning of radiologically contaminated pipes. Our main objective consists of establishing an internal barrier (plug) to mitigate the release of residual contamination prior to cutting operations and required pipework for deactivation and decommissioning projects. To ensure worker safety, we will also be analyzing hazards associated with the off gasses present during curing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation Exercise of a Coarse Finite Element Model of Laser Welds

The objective of this project is to validate low-fidelity models of 304L to 304L stainless steel partial-penetration laser welds for thin sheets. Low-fidelity means that the weld is represented by coarsely meshed element blocks. Here, the hexahedral element size is approx imately half the weld penetration depth. The material behavior of the block is represented by a J2 plasticity model with a Voce hardening function. The source of the data used in this work is an extensive experimental study conducted by Sharlotte Kramer (1528) and published in 2015. Figure 1 shows a cross-section of the weld of interest. The nominal thickness of the sheets is 0.063 in. while the target penetration depth of the weld is in the range of 0.028 to 0.032 in., extending about half the sheet thickness. Uniaxial tension tests provided data for calibration of base material and weld models. Results of two validation geometries were also provided. The principal validation geometry is shown in Fig. 2. It consists of a plate specimen with in-plane dimensions 6 in × 2.875 in loaded in tension. A circular plug with a 1.5 in. diameter was cut from the center of the plate and then welded in place. The details of the welding schedule are given. An important assumption is that the welds in the calibration and validation specimens have similar geometric and material properties as those in the validation tests. The task was to first calibrate models for the base material and the welds and then simulate the validation tests until the point of weld first failure.

36 MATERIALS SCIENCE↗

Results from an Aeromagnetic Survey to Detect Steel-Cased Wells at a Marcellus Shale Well Site in Washington County, Pennsylvania

Pennsylvania has a 150-year history of oil and gas production—the longest of any state—and this enduring activity has resulted in the drilling of more than 300,000 recorded wells. However, unknown wells likely exist because innumerable wells were drilled during Pennsylvania’s intense early oil and gas history when incomplete records were kept of well locations. There is concern that early wells are likely to be ineffectively sealed because there were no laws that required plugging when the wells were abandoned. Today, many undocumented and unplugged wells are thought to be in areas of emerging shale gas and shale oil development where open wellbores can provide a pathway for undesired upward migration of fluids and gas from hydraulically fractured reservoirs. Due to this concern, Pennsylvania regulators have asked operators to locate orphaned and abandoned wells within a 1,000-ft buffer of proposed new wells. The objective of this report is to demonstrate that high-resolution aeromagnetic surveys, historic air photos, and Light Detection and Ranging (LiDAR) imagery can be rapid and effective methods to reconnoiter large, forested areas of moderate terrain for the presence of abandoned wells. These well-finding methods were evaluated at a proposed Marcellus Shale gas drilling site in Washington County, Pennsylvania, where the methods collectively located 18 confirmed wells: 15 wells were identified from aeromagnetic surveys, two wells were identified from inspection of historical air photos, and one well was identified by evaluation of state-wide LiDAR imagery. Only six wells were previously known, and their locations, as recorded in Pennsylvania’s statewide oil and gas wells database (PA/IRIS/WIS), were often too inaccurate for the wells to be found in the dense underbrush. Twelve wells identified in this study were abandoned, unmarked, and undocumented. Aeromagnetic surveys locate wells by detecting the unique magnetic signature of vertical, steel well casing, which is depicted on magnetic maps as a “bull’s eye” type anomaly that is centered directly over the well. However, when wells were drilled and found to be sub-economic, their casing was sometimes pulled and salvaged for reuse. Such wellbores provide no magnetic response and go undetected if all casing was removed. Oftentimes attempts to retrieve well casing were not 100% successful. For example, historical records for one well in the study area indicate that the well was completed in 1902 as a dry hole and that, to the extent possible, the casing was pulled for reuse. However, a section of 10-in. diameter steel casing was not recovered and remains at an unknown depth in the wellbore. This well was easily detected by the aeromagnetic survey although only deep casing remained in the well. To mitigate for the likelihood that wellbores exist where most or all casing has been removed, this study augmented aeromagnetic data with historic air photos and digital terrain models generated from LiDAR datasets—both databases are publicly available at no cost for areas within Pennsylvania. These complementary methods located three wells where the aeromagnetic anomaly, although present, was subtle and overlooked. Together, these methods determined accurate locations for six known wells within the study area and located 12 previously unknown wells. Although it is not certain that these methods successfully located all wells in the study area, the application of these methods does represent a significant improvement over relying on existing databases for well locations. For the Appendix to the report, see: https://www.netl.doe.gov/energy-analysis/details?id=b46c417a-7c9e-4d25-b810-e6248b0217f4</p>

04 OIL SHALES AND TAR SANDS↗

Studies of Helium Behavior in Uranium Hexafluoride

Several issues have arisen from experimental observations and/or theoretical postulation related to the behavior of helium in uranium hexafluoride (UF 6 ) matrices and how it may impact the ability to use this noble gas to quantify the fill date of the cylinder. A series of experiments was conducted to address several such issues, and the results and implications are reported here. Two issues relate to bias in the helium measurement due to ambient air from extraneous sources such as atmospheric air or from potential holdup in a large, activated alumina chemical trap. These issues are really a question of differential retention of helium versus three other inert gas isotopes (representative of other noble gases found in air) used as a calibration for air in leakage. Discernable bias was not detected in either case. Another issue had to do with helium potentially brought into the cylinder by a liquid UF 6 fill and subsequently released as the material solidifies and/or during storage. The solubility of helium in liquid UF 6 was measured to investigate this theory. The experiment quantified the potential magnitude of the initial helium contribution if present. The final issue was that of retention of helium in solid UF 6 . Investigation of this theory necessitated quantifying both the solubility and the diffusivity of helium in UF 6 . In one experiment, the solubility was measured at cryogenic temperature, allowing quantification of helium in solid UF 6 such as would be found in a cold trap. In a second experiment, transport of helium into and through a macroscopic plug of solid UF 6 was examined. The transport was very slight although apparently detectible. Effectively, only an upper limit to the transport could be determined, but that limit implied that helium holdup in solid UF 6 is a real possibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TEAMER - Field Demonstration of MarineSitu’s Marine Energy Monitoring Tools - CRADA 664 (Abstract)

In order to effectively monitor for marine life around marine energy devices and thus minimize the risk of collision, multiple sensors working in coordination and augmented with around-the-clock automated monitoring algorithms need to be installed in challenging high-energy tidal and wave environments. Such systems are often too expensive for widespread adoption, or lack sufficient sensors or smarts to enable around-the-clock, real-time monitoring without human involvement. MarineSitu has been working to tackle this problem by developing a low-cost, combined sonar and stereo camera sensor array with connected real-time AI-based algorithms for automatically detecting marine life in these marine energy suitable environments. In this TEAMER project with Pacific Northwest National Lab (PNNL), MarineSitu will be testing this novel sensor system for the first time in the high-energy tidal channel environment at PNNL’s Marine and Coastal Research Lab. Throughout this deployment, MarineSitu will be monitoring their system and running analytics on the sensor’s data in real-time. Meanwhile, PNNL Data Scientists and Ocean Engineers, will be evaluating the system’s effectiveness and ease of use both as a tool for plug-and-play environmental monitoring and novel environmental monitoring research. In doing so, the team will improve MarineSitu’s system and software, produce insightful data products, and develop novel visualizations and AI algorithms for combining and analyzing the data produced by systems like MarineSitu’s.

16 TIDAL AND WAVE POWER↗