ProfileSR-GAN: A GAN Based Super-Resolution Method for Generating High-Resolution Load Profiles
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
This study examines the impact of reserve margin-based reliability assessment, as commonly used in capacity expansion models, on planning resource-adequate power systems under high penetrations of solar photovoltaics (PV). As a generation resource, PV is operationally different from the conventional dispatchable resources for which most capacity expansion models were designed. The question this study attempts to answer is whether large amounts of PV on a system (in this case, the Western Interconnection of North America) would bias the results of conventional reserve margin-based capacity expansion modeling towards an over- or under-provisioning of resource adequacy. This analysis used NREL’s Resource Planning Model (RPM) for capacity expansion modeling and NREL’s Probabilistic Resource Adequacy Suite (PRAS) for resource adequacy assessment. RPM uses a reserve margin requirement to enforce resource adequacy. PRAS, a collection of tools for studying the resource adequacy of power systems and the adequacy contributions of individual resources on a probabilistic basis, was used to compute multiple resource adequacy metrics across a number of simulated scenarios and system representations with differing regional detail. In all cases, including high PV penetrations (up to 33% annual generation from PV, interconnection-wide), RPM was able to produce resource-adequate systems as measured by normalized expected unserved energy and loss-of-load expectation results from PRAS. The accuracy of reserve margin approaches depends heavily on the underlying assumptions informing the capacity credit assigned to variable and energy-limited resources, particularly when such resources are abundant in the modeled system. RPM’s standard methodology for estimating variable and flexible resources’ capacity contributions, which is based on the top 100 hours of net load, did not appear to systematically undervalue or overvalue variable generation relative to a more rigorous equivalent firm capacity assessment using PRAS, although both over- and under-valuations were observed in specific scenarios. In the worst cases, the top 100 hour method underestimated the equivalent firm capacity of PV by two percentage points, and overestimated the equivalent firm capacity of PV by five percentage points. Calculating capacity contributions based on the top 10 hours of net load systematically underestimated equivalent firm capacities at more modest PV penetrations, but was often a better approximation of equivalent firm capacity than the existing 100-hour approach in scenarios with higher PV penetrations.
Al-Si cast alloys are usually composed of α-Al and Al-Si eutectic. Si flakes and Al matrix generally hold cube-on-cube orientation relationship with the primary interface (111) Al ∥(111) Si . Extensive experimental studies demonstrated that Si flakes cannot significantly improve mechanical properties of Al-Si cast alloys. We hypothesize that the weak strengthening effect associated with Si flakes might be attributed to thermomechanical properties of Al-Si interfaces besides their morphologies. To characterize Al-Si interfaces with a large lattice mismatch (> 30%), we proposed the quasi-coincident site lattice (Q-CSL) as reference lattice, and demonstrated that the Q-CSL Al-Si coherent interface has three characteristic coherent structures, one stable and low energy structure and two metastable and high energy structures. The translation vectors for the same type of coherent Q-CSL structures are consistent with three displacement shift complete (DSC) vectors. The two metastable structures can be obtained by shifting the low energy structure with three partial DSC vectors. Semi-coherent interface is composed of the low energy Q-CSL patches and three sets of interface misfit dislocations with Burgers vectors same as the DSC vectors. Atomistic simulations revealed that Al-Si interface exhibits low shear resistance. Ideal shear strength of the Q-CSL coherent interface is 110 MPa and semi-coherent interface is 20 MPa. The low shear resistance is attributed to the glide of interface misfit dislocations. Al-Si interface also exhibits low formation and migration energies of point defects. Owing to low shear strength and low formation and migration energies of point defects, interface sliding or shear readily happen under mechanical loading or during dislocation-interface interactions. Lattice dislocations can cross slip onto or climb along Al-Si interfaces. These reactions decrease the number of accumulated dislocation loops around Si flakes and promote nucleation and emission of lattice dislocations from Al-Si interfaces to matrix, consequently reduce the repulsive force on approaching dislocations and weaken Si flakes strengthening effect. In situ tension and compression tests in a scanning electron microscope reveal relatively weak strengthening effect due to Si flakes, consistent with the computed dislocation interaction with interfaces and shear behavior of interfaces.
Absorption based direct air capture (DAC) technologies have garnered significant interest in recent years due to their scalability, competitive regeneration energy requirements, and low susceptibility to degradation. One of the key advantages of DAC lies in its flexible siting options and the potential to utilize low-value land. However, most of the research in this field has been focused on ambient climate zones (T > 20 °C), overlooking sub-ambient (–30 °C < T < 20 °C) regions, which comprise approximately 70 % of the Earth’s surface. To fully realize the potential of DAC, it is essential to understand how DAC solvents perform in these sub-ambient conditions before any large-scale deployment can be considered. Among DAC solvents of interest, potassium sarcosinate (K-SAR) has emerged as a promising candidate due to its high CO 2 capacity, fast uptake kinetics, compatibility with contactor packing materials, low volatility, good thermal and oxidative stability, and competitive regeneration energy requirements compared to current industry standards. This paper characterizes the CO 2 flux and viscosity of K-SAR at sub-ambient conditions and explores the potential of using ethylene glycol and triethylene glycol as additives to prevent solvent freezing in DAC applications. For 1 M K-SAR, the CO 2 flux ranges between 1.3 × 10 -5 and 8.0 × 10 -5 mol m –2 s –1 across a temperature range of –5 °C to 45 °C. Ethylene glycol is shown to effectively suppress the freezing point of K-SAR below –30 °C with volumetric loadings of the additive as low as 0.1. Here, a reaction model was developed to predict the CO 2 flux for 1 M K-SAR at different temperatures, demonstrating good agreement between experimental and theoretical fluxes.
C4F7N [2,3,3,3-tetrafluoro-2-(trifluoromethyl)propanenitrile]/CO2 gas mixtures are being developed as an eco-friendly electrical insulator to replace SF6, the most potent greenhouse industrial gaseous dielectric. However, recent studies have reported complicated and often conflicting decomposition pathways for C4F7N/CO2 gas mixtures, which has raised concerns. In this work, the decomposition characteristics of C4F7N/CO2 gas mixtures were studied comprehensively by both designed computations and experiments. Computations were performed starting from fundamental propositions of C4F7N/CO2 decompositions, which were further experimentally verified by pyrolysis, long-term thermal aging with/without catalytic materials (industrial-grade molecular sieves 4A), and electrical decomposition by spark discharge. The results of both computations and experiments suggest that in an ideal thermal decomposition, C4F7N is likely to decompose into C2F6 and small fluoronitriles first at high temperatures. The generation of C3F6 and C2N2 from C4F7N thermal decomposition at lower temperatures appears because of the catalytic effect of incompatible materials, for example, the industrial-grade molecular sieves 4A that we tested. The electron impact dissociation of C4F7N plays an important role in C4F7N electrical decomposition, leading to additional formation of distinctive small molecules of CF4 and C2N2 of low concentrations. It was pointed out based on a real arcing test in a load disconnector that the decomposition of C4F7N gas mixtures in real applications will be at a much moderate and manageable rate than what was obtained from the highly accelerated laboratory tests presented in this work. The signatures of decomposition products extracted in this study provide invaluable guidance for developing decomposition-based diagnosis and fixation of decomposition byproducts toward SF6-free power grids.
The width tapered beam method for measuring fracture toughness has been contemplated for use in measuring the adhesion of photovoltaic materials, is promoted by it being a viable method for use directly on modules rather than to engineered test specimens. However, precise determination of crack length is often difficult as failure often involves tendril formation, cavitation voids, and other plastic deformation at the crack front in addition to obfuscation by opaque materials. Because fracture energy varies as the square of crack length, imprecise crack tip length results in large measurement uncertainties. In this work, we develop a method to estimate the crack tip length using the relationship between the applied force and the displacement of the load frame. The crack tip is determined for every data point and can be defined from a calibration curve related to the amount of energy put into the beam, or from a theoretically idealized estimation. Once a calibration curve is set up and the equations programmed, the fracture energy as a function of position on the newly formed crack interface can be accurately estimated. The test additionally provides much easier analysis and insight into the joint failure through more precise knowledge of fracture toughness at each de-bonded area.
Abstract The response of a polycrystalline material to a mechanical load depends not only on the response of each individual grain, but also on the interaction with its neighbors. These interactions lead to local, intragranular stress concentrations that often dictate the initiation of plastic deformation and consequently the macroscopic stress–strain behavior. However, very few experimental studies have quantified intragranular stresses across bulk, three-dimensional volumes. In this work, a synchrotron X-ray diffraction technique called point-focused high-energy diffraction microscopy (pf-HEDM) is used to characterize intragranular deformation across a bulk, plastically deformed, polycrystalline titanium specimen. The results reveal the heterogenous stress distributions within individual grains and across grain boundaries, a stress concentration between a low and high Schmid factor grain pair, and a stress gradient near an extension twinning boundary. This work demonstrates the potential for the future use of pf-HEDM for understanding the local deformation associated with networks of grains and informing mesoscale models. Graphical abstract
The share of electronics-based residential load is expected to rise as devices such as variable frequency drives (VFDs), electric vehicle chargers, and inverter-based distributed energy resources (DERs), e.g., photovoltaic (PV) systems become more common. These loads may introduce significant harmonics into power networks that need to be closely studied in order to perform accurate load modeling and forecasting. However, it can be difficult to obtain harmonic-rich voltage and current data - necessary for identifying accurate load models - for residential electrical loads. Recognizing this need, we identify and model a set of electronics-based end-use loads and DERs in an electromagnetic transients program (EMTP) tool for a residence with a single- phase split-phase supply. Further, a procedure is developed to model harmonic interactions between end-use loads connected to the same non-ideal supply voltage in a residential setting. Finally, a harmonic-rich dataset produced via the proposed procedure is utilized to identify frequency coupling matrix (FCM) based load model. Numerical results demonstrate the accuracy of the model, and explore model identifiability with limited data points.
Marine energy structures are typically made of advanced composite materials and are subjected to extreme ocean environments in service. In extreme ocean environments, seawater currents and waves load structures repeatedly, which cause two environmental conditions: water intrusion and mechanical fatigue. In prior research, the two environmental conditions were applied sequentially, where composite specimens were aged and then mechanically tested. To understand the combined effects of dynamic loading and water intrusion on composite materials, the present study involves the static and fatigue four-point bend testing of composite coupons in a water tank. The water tank was designed and built to fit either a 100 kN or a 250 kN load frame. Flexural strength value, cycles to failure, and failure mode results from submerged fatigue testing will be used to inform marine energy structure designs. The coupon-scale test method will be used to scale up to and inform methods for subsequent subcomponent testing and standards development. The benefits of designing marine energy structures to informed standards are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.
Marine energy structures are typically made of advanced composite materials and are subjected to extreme ocean environments in service. In extreme ocean environments, seawater currents and waves load structures repeatedly, which cause two environmental conditions: water intrusion and mechanical fatigue. In prior research, the two environmental conditions were applied sequentially, where composite specimens were aged and then mechanically tested. To understand the combined effects of dynamic loading and water intrusion on composite materials, the present study involves the static and fatigue four-point bend testing of composite coupons in a water tank. The water tank was designed and built to fit either a 100 kN or a 250 kN load frame. Flexural strength value, cycles to failure, and failure mode results from submerged fatigue testing will be used to inform marine energy structure designs. The coupon-scale test method will be used to scale up to and inform methods for subsequent subcomponent testing and standards development. Finally, the benefits of designing marine energy structures to informed standards are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.
Marine energy structures are typically made of advanced composite materials and are subjected to extreme ocean environments in service. In extreme ocean environments, seawater currents and waves load structures repeatedly, which cause two environmental conditions: water intrusion and mechanical fatigue. In prior research, the two environmental conditions were applied sequentially, where composite specimens were aged and then mechanically tested. To understand the combined effects of dynamic loading and water intrusion on composite materials, the present study involves the static and fatigue four-point bend testing of composite coupons in a water tank. The water tank was designed and built to fit either a 100 kN or a 250 kN load frame. Flexural strength value, cycles to failure, and failure mode results from submerged fatigue testing will be used to inform marine energy structure designs. The coupon-scale test method will be used to scale up to and inform methods for subsequent subcomponent testing and standards development. The benefits of designing marine energy structures to informed standards are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.
Marine energy structures are typically made of advanced composite materials and are subjected to extreme ocean environments in service. In extreme ocean environments, seawater currents and waves load structures repeatedly, which cause two environmental conditions: water intrusion and mechanical fatigue. In prior research, the two environmental conditions were applied sequentially, where composite specimens were aged and then mechanically tested. To understand the combined effects of dynamic loading and water intrusion on composite materials, the present study involves the static and fatigue four-point bend testing of composite coupons in a water tank. The water tank was designed and built to fit either a 100 kN or a 250 kN load frame. Flexural strength value, cycles to failure, and failure mode results from submerged fatigue testing will be used to inform marine energy structure designs. The coupon-scale test method will be used to scale up to and inform methods for subsequent subcomponent testing and standards development. The benefits of designing marine energy structures to informed standards are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.
This paper presents a system-level efficiency study of modular DC/DC converter and fuel cell stack configurations under series, parallel, and series–parallel connections. The investigation considers selected DC/DC converter topologies, including isolated and non-isolated architectures, boost, non-inverting buck-boost, and resonant converters, integrated with commercially available fuel cell stacks, including the Accelera FCE150, Ballard FCgen-HPS, and Toyota TFCM2. DC/DC converter modules are evaluated in modular configurations rated at 60 kW and 90 kW and two distinct output voltage ranges, specifically 580–730V and 780–930V, examining how different interconnection schemes impact overall system efficiency. The converters are evaluated under full load (100%), partial load (66%), and light load (33%) conditions, providing a comprehensive assessment of efficiency and operational characteristics across varying power demands. Approximately two-thousand efficiency data points are obtained from laboratory prototype–level component measurements and validated design evaluations across multiple converter topologies, modular configurations, voltage ranges, and load conditions, providing a robust dataset for comparative system-level efficiency analysis. The results highlight the effects of modularity and topology selection on system-level efficiency, offering a “playbook” framework for designers to select appropriate DC/DC converter arrangements and fuel cell stack connections for series, parallel, or hybrid configurations based on efficiency considerations.
Uranium borides are promising candidate fuel forms for use in advanced nuclear reactors due to their high thermal conductivity and potential for dual use as both fuel and burnable absorber. In this work, uranium tetraboride () and uranium monoboroncarbide (UBC) composite were synthesized by using industrially scalable carboborothermic reduction method. The final uranium boride phase composition is sensitive to the sample holding crucibles ( and graphite) such that graphite supply excess carbon, promoting the formation of a predominant UBC phase. The high‐temperature in situ synchrotron X‐ray diffraction of pristine –UBC show persistence , UBC, and phases while preoxidized –UBC leads to predominant and formation due to progressive oxidation and boron loss at high temperature. The oxidation behavior was further characterized using thermogravimetric analysis, allowing direct comparison with other potential accident tolerant fuels such as , , UC, and UN. The –UBC shows higher uranium loading than monolithic and demonstrates promising oxidation behavior at high temperature, pointing to its potential as an improved uranium boride‐based fuel form.
As extreme weather events become more frequent and intense, the demand for connecting grid operation and infrastructure planning with extreme event models will increase as well. We present a methodology for creating damage contingencies and scenarios for electric transmission grids during a hurricane strike. Included is an example case study: Hurricane Dolly damaging a synthetic 2000 bus test system during its landing in Southern Texas. Using WIND Toolkit meteorological data in conjunction with fragility curves for various electric grid elements, we generate stochastic damage scenarios that can be used for short- and long-term planning problems including emergency asset management. We perform statistical analysis of damages and quantify topological effects on example synthetic grid. Also, we investigate loss-of-load events during two-day economic dispatch experiment. Finally, we point out various shortcomings of our method and suggest how it can be improved.
As extreme weather events become more frequent and intense, the demand for connecting grid operation and infrastructure planning with extreme event models will increase as well. We present a methodology for creating damage contingencies and scenarios for electric transmission grids during a hurricane strike. Included is an example case study: Hurricane Dolly damaging a synthetic 2000 bus test system during its landing in Southern Texas. Using WIND Toolkit meteorological data in conjunction with fragility curves for various electric grid elements, we generate stochastic damage scenarios that can be used for short- and long-term planning problems including emergency asset management. We perform statistical analysis of damages and quantify topological effects on example synthetic grid. Also, we investigate loss-of-load events during two-day economic dispatch experiment. Finally, we point out various shortcomings of our method and suggest how it can be improved.
The integration of the inverter-based renewable energy resources is increasing and replacing conventional synchronous generators in the evolving bulk power system (BPS), impacting the system inertia along the way. Also, the limited over-current capability of power electronic converters continues to deteriorate the grid strength of the evolving power systems. Type-5 wind turbines have the potential to mitigate these problems because this configuration interfaces with the grid through a synchronous generator; hence, its operation and consequent grid impacts might mimic the conventional synchronous generator. The drivetrain of this type of turbines, however, is different from the more common Type-3 and Type-4 turbines. A hydraulic torque converter and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine drivetrain, to isolate the wind speed variations at the wind turbine rotor from the grid connected generator side. This supports the synchronous operation of the generator. However, high fidelity models of Type-5 wind turbine drivetrain including these core components are not openly and widely available for grid integration and transient stability studies. Moreover, Type-5 turbines are not commonly deployed and hence its power generation and frequency stability characteristics are not widely publicized. This hinders appropriate assessment of Type-5 wind power plant's contribution to bulk grid resilience. This work provides transient stability assessment of a standalone Type-5 wind turbine. Normal operation and grid transient studies are performed to see the step load change and wind speed disturbance impacts on the Type-5 drivetrain and generation dispatch. Preliminary results show that Type-5 wind turbines can support load changes of between 0.6 p.u to 1.15 p.u. Beyond this point, the synchronization of the generator starts to deviate from its set point.
This paper proposes a virtual oscillator-based control architecture for a grid-forming converter with an inner current control loop. In general, the virtual oscillator is based on a Lienard type of oscillator equation with a cubic nonlinearity. A virtual oscillator alone cannot accommodate unbalanced or harmonic mitigation while operating converters in grid-forming mode. Therefore, to accomplish better tracking performance, incorporating the provision for nonlinear and/or unbalanced loads, an inner current control loop is utilized that is based on the Lyapunov energy function type control architecture. To reduce the overall cost of implementation and ensure proper phase difference in the generated voltages, the implemented virtual oscillator operates with only one voltage feedback from the point of common coupling. To verify the effectiveness of the proposed approach, the overall system has been modeled in MATTLAB/Simulink and PLECS domain. This paper also presents case studies showing the successful production of low harmonic load voltages under nonideal loading conditions, along with other important results.