Search NASA⌕ Search

SEARCH · Search NASA

Results for “polytetrafluoroethylene”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Thermal anomalies in stressed Teflon.

In the course of testing polytetrafluoroethylene (Teflon) as a calorimetric gasketing material, serendipity revealed a thermal anomaly in stressed film that occurs concomitantly with the well-documented 25 C transition. The magnitude of the excess energy absorption - about 35 cal/g - is suggested to be related to the restricted thermal expansion of the film.

Lee, S. H.↗

Auger analysis of films formed on metals in sliding contact with halogenated polymers

The use of Auger electron spectroscopy (AES) to search for transferred polymer must contend with the fact that there has been no published work on Auger analysis of polymers. Since this is a new area for AES, the Auger spectra of polymers and of halogenated polymers in particular is discussed. It is shown that the Auger spectra of halogenated polymers have certain characteristics that permit an assessment of whether a polymeric transfer film has been established by sliding contact. The discussion is general and the concepts should be useful in considering the Auger analysis of any polymer. The polymers chosen for this study are the halogenated polymers polytetrafluoroethylene (PTFE), polyvinyl chloride (PVC), and polychlorotrifluorethylene (PCTFE).

Pepper, S. V.↗

The Acute Inhalation Toxicity in Rats from the Pyrolysis Products of Four Fluoropolymers

Male Sprague-Dawley rats (225?250 g) were exposed to the thermal degradation products from four fluoropolymers. The three polymers containing vinylidene fluoride and hexafluoropropene (VF2/HFP) were pyrolyzed at 550? and 800?C, whereas polytetrafluoroethylene (PTFE) was pyrolyzed at 625 and 800?C. At the lower temperatures, the pyrolysate from the copolymer of vinylidene fluoride and hexafluoropropene (VF2/HFP) was less toxic than the pyrolysates from either the terpolymer of vinyidene fluoride, hexafluoropropene, and tetrafluoroethylene (VF2/HFP/TFE) or the copolymer of vinylidene fluoride and hexafluoropropene with ?additives? (VF2/HFP-A). However, the pyrolysates from the VF2/HFP-containing materials produced less toxic products than the pyrolysate from PTFE at 625?C. When the pyrolysis temperature was increased to 800?C, very little difference was noted between the pyrolysis toxicity for any of the VF2/HFP-containing polymers with the most toxic pyrolysate again produced by PTFE. Carbon monoxide levels were all sublethal. No correlation could be established between hydrolyzable fluoride levels and the lethality of the pyrolysates. Death following exposure occurred within 48 hr due to acute pulmonary edema and hemorrhage. Survival of this acute phase was followed by alveolar lymphocytic infiltration and peribronchial tissue proliferation.

Carter, V. L., Jr.↗

High-temperature flat-conductor cable

Temperature limit of 25-conductor signal cable and 3-conductor power cable, fabricated using woven and roll laminated technique, increased from 200 C to 350 C when polyimide/fluorinated ethylene propylene or polytetrafluoroethylene insulation films and fluorinated ethylene propylene as adhesive medium is applied.

Rigling, W. S.↗

Splicing shielded cables

Simple repair technique retains cable characteristic impedance. Shielded-Cable Splicing Technique retains cable characteristic impedance. Procedure involves splicing inner conductors in staggered pattern, installing jumper braid by heat-shrinking two solder sleeves, and placing insulation sleeve over repaired section and heat-shrinking it. Two possible insulation materials are modified polyvinylidene fluoride and polytetrafluoroethylene.

Lind, W. P.↗

The use of an ion-beam source to alter the surface morphology of biological implant materials

An electron bombardment, ion thruster was used as a neutralized-ion beam sputtering source to texture the surfaces of biological implant materials. Scanning electron microscopy was used to determine surface morphology changes of all materials after ion-texturing. Electron spectroscopy for chemical analysis was used to determine the effects of ion texturing on the surface chemical composition of some polymers. Liquid contact angle data were obtained for ion textured and untextured polymer samples. Results of tensile and fatigue tests of ion-textured metal alloys are presented. Preliminary data of tissue response to ion textured surfaces of some metals, polytetrafluoroethylene, alumina, and segmented polyurethane were obtained.

Weigand, A. J.↗

Ion beam sputter etching and deposition of fluoropolymers

Fluoropolymer etching and deposition techniques including thermal evaporation, RF sputtering, plasma polymerization, and ion beam sputtering are reviewed. Etching and deposition mechanism and material characteristics are discussed. Ion beam sputter etch rates for polytetrafluoroethylene (PTFE) were determined as a function of ion energy, current density and ion beam power density. Peel strengths were measured for epoxy bonds to various ion beam sputtered fluoropolymers. Coefficients of static and dynamic friction were measured for fluoropolymers deposited from ion bombarded PTFE.

Banks, B. A.↗

Polymeric electrolytic hygrometer

An improved flow-through electrolytic hygrometer is described which utilizes a long lasting oxidation-resistant, hollow fiber formed from persulfonic acid substituted polytetrafluoroethylene having closely spaced noble metal electrodes in contact with the inner and outer surfaces of the fiber. The fiber is disposed within a chamber so that the moisture-bearing gas passes in contact with at least one surface of the fiber. The electrodes are connected in series to a dc voltage supply and an ammeter. As the gas passes through the chamber, moisture absorbed into the wall of the fiber is electrolyzed to hydrogen and oxygen by the closely spaced electrodes. The amount of electricity required for electrolysis is proportional to the absorbed moisture and is observed on the ammeter.

Lawson, D. D.↗

Ion beam sputter etching and deposition of fluoropolymers

Fluoropolymer etching and deposition techniques including thermal evaporation, RF sputtering, plasma polymerization, and ion beam sputtering are reviewed. Etching and deposition mechanisms and material characteristics are discussed. Ion beam sputter etch rates for polytetrafluoroethylene (PTFE) were determined as a function of ion energy, current density and ion beam power density. Peel strengths were measured for epoxy bonds to various ion beam sputtered fluoropolymers. Coefficients of static and dynamic friction were measured for fluoropolymers deposited from ion bombarded PTFE.

Banks, B. A.↗

Friction coefficients of PTFE bearing liner

Data discusses frictional characteristics of PTFE (polytetrafluoroethylene) under temperature extremes and in vacuum environment. Tests were also run on reduced scale hardware to determine effects of vacuum. Data is used as reference by designers of aircraft-control system rod-end bearings and for bearings used in polar regions.

Daniels, C. M.↗

Strain relief for power-cable connectors

Easily fabricated grommet composed of polytetrafluoroethylene cylinder, containing U-shaped channels equally spaced around periphery, is used in power cable connectors to relieve strain on cables. Utilization of grommets provides more ease in cable insertion and removal. Potential applications include wiring in large residential and commercial buildings.

Dean, W. T., III↗

Rotatable microscope stage

Samples mounted on rotatable microscope stage consisting of aluminum hemisphere resting in hemispherical cavity of polytetrafluoroethylene base is viewed at various angles. Stage permits operator to orient sample at selected fixed angles.

Ivanisko, J. A.↗

Increased fuel-cell cross-pressure limit

Polytetrafluoroethylene (PTFE) impregnated support screen increases cross pressure on electrolyte-filled matrix in fuel-cell passive water-removed unit. This increases cell operating pressure limit which may improve performance and life characteristics of passive water-removal-type fuel cells.

Bell, W. F.↗

Mechanical and chemical effects of ion-texturing biomedical polymers

To determine whether sputter etching may provide substantial polymer surface texturing with insignificant changes in chemical and mechanical properties, an 8 cm beam diameter, electron bombardment, argon ion source was used to sputter etch (ion-texture process) nine biomedical polymers. The materials included silicone rubber, 32% carbon impregnated polyolefin, polyoxymethylene, polytetrafluoroethylene, ultrahigh molecular weight (UHMW) polyethylene, UHMW polyethylene with carbon fibers (10%), and several polyurethanes (bioelectric, segmented, and cross linked). Ion textured microtensile specimens of each material except UHMW polyethylene and UHMW polyethylene with 10% carbon fibers were used to determine the effect of ion texturing on tensile properties. Scanning electron microscopy was used to determine surface morphology changes, and electron spectroscopy for chemical analysis was used to analyze the near surface chemical changes that result from ion texturing. Ion energies of 500 eV with beam current densities ranging from 0.08 to 0.19 mA/sq cm were used to ion texture the various materials. Standard microtensile specimens of seven polymers were exposed to a saline environment for 24 hours prior to and during the tensile testing. The surface chemical changes resulting from sputter etching are minimal in spite of the often significant changes in the surface morphology.

Weigand, A. J.↗

Transient ablation of Teflon in intense radiative and convective environments

On the basis of this investigation of the high-temperature behavior of polytetrafluoroethylene (PTFE), the transient one-dimensional ablation of PTFE has been developed by taking into account the optical transmittance of both the amorphous zone and the crystalline zone of PTFE layer. Results show that although the exposed surface receded at an apparently steady state, both the internal temperature and the thickness of the gel layer increase continuously due to the internal absorption of radiation.

Arai, N.↗

Connector heat shield

Polytetrafluoroethylene tape wrapped around electrical connectors protects them from heat damage during soldering. Tape is easily removed after contacts are joined.

Clarke, S.↗

Foam-filled cushions for sliding trays

Polytetrafluoroethylene tube filled with polyurethane foam forms low friction sliding surface that cushions vibrations and absorbs manufacturing tolerances and misalignment. Possible uses include packaging of components for shipping and seals for doors in lockers, cars, and refrigerators.

Nahin, S. B.↗

Ball-joint grounding ring

In ball and socket joint where electrical insulator such as polytetrafluoroethylene is used as line to minimize friction, good electrical contact across joint may be needed for lightning protection or to prevent static-charge build-up. Electrical contact is maintained by ring of spring-loaded fingers mounted in socket. It may be useful in industry for cranes, trailers, and other applications requiring ball and socket joint.

Aperlo, P. J. A.↗