Search NASA⌕ Search

SEARCH · Search NASA

Results for “portable power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Advanced control design for hybrid turboelectric vehicle

The new environment standards are a challenge and opportunity for industry and government who manufacture and operate urban mass transient vehicles. A research investigation to provide control scheme for efficient power management of the vehicle is in progress. Different design requirements using functional analysis and trade studies of alternate power sources and controls have been performed. The design issues include portability, weight and emission/fuel efficiency of induction motor, permanent magnet and battery. A strategic design scheme to manage power requirements using advanced control systems is presented. It exploits fuzzy logic, technology and rule based decision support scheme. The benefits of our study will enhance the economic and technical feasibility of technological needs to provide low emission/fuel efficient urban mass transit bus. The design team includes undergraduate researchers in our department. Sample results using NASA HTEV simulation tool are presented.

Abban, Joseph↗

Assessing the Added Value of Miniature X-Ray in the Setting of Portable Ultrasound in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in low-Earth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

J G Steller↗

Assessing the Added Value of Miniature X-Ray in the Setting of US in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in lowEarth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

Jon Steller↗

Portable headset microphone checker

Simple and reliable test system gives go/no-go indication of output level of headset microphones. Portable system has its own internal battery power supply and can be used in field or in laboratory with wide variety of headset types.

Davenport, J.↗

Time-domain sensitivity enhancement in pulsed Pb-TDL gas monitors

A Pb-salt tunable diode laser (TDL) has found many applications in the field of atmospheric gas analysis. Its continuous tunablility and fine spectral purity in the mid infrared region are outstanding from other lasers. The only shortcoming is that it requires cryogenic operating temperatures, though, it is improved year by year towards the room temperature operation. A repeated pulse operation of Pb salt diode lasers is possible with a thermoelectric cooling device, which allows an instrument a portable geometry disusing a heavy, bulky and power consuming mechanical refrigerator. A derivative spectrometry was exploiting the quick tunability of Pb salt diode lasers, though they are continuous wave (cw) operated with refrigerator or liquid nitrogen so far. A new system for derivative spectrometry with a pulsed diode laser will extend its field of applications because of reduced weights and size of measuring instruments. A preliminary results is shown that demonstrates the feasibility of an attempt to implement the derivative spectrmetry with repeatedly pulse driven diode lasers. Atmospheric methane was measured with 8 ppm/m sensitivity. Further results of parametric optimization for the best signal to noise ratios under any given device characteristics as well as for available real devices is given.

Koga, R.↗

Ampere-Hour Meter For Rechargeable Battery

Low-power analog/digital electronic circuit meters discharge of storage battery in ampere-hours. By metering discharge, one obtains indication of state of charge of battery and avoids unnecessary recharging, maintaining capacity of battery and prolonging life. Because of its small size and low power consumption, useful in such applications as portable video cameras, communication equipment on boats, portable audio equipment, and portable medical equipment.

Tripp, John S.↗

Thin-Film Resistive Heater

Thin-film electrically resistive heater applies high, controlled flux of heat to surface of object. Heater mounted directly on surface of object. It is small, simple to operate, and less expensive than laser and arc heating facilities. Because only other equipment needed appropriate power supply, thin-film heater essentially portable device useful in wide range of eventual applications in research and in field.

Scotti, Stephen J.↗

New Lithium-ion Polymer Battery for the Extravehicular Mobility Unit Suit

The Extravehicular Mobility Unit (EMU) suit currently has a silver-zinc battery that is 20.5 V and 45 Ah capacity. The EMU's portable life support system (PLSS) will draw power from the battery during the entire period of an EVA. Due to the disadvantages of using the silver-zinc battery in terms of cost and performance, a new high energy density battery is being developed for future use, The new battery (Lithium-ion battery or LIB) will consist of Li-ion polymer cells that will provide power to the EMU suit. The battery design consists of five 8 Ah cells in parallel to form a single module of 40 Ah and five such modules will be placed in series to give a 20.5 V, 40 Ah battery. Charging will be accomplished on the Shuttle or Station using the new LIB charger or the existing ALPS (Air Lock Power Supply) charger. The LIB delivers a maximum of 3.8 A on the average, for seven continuous hours, at voltages ranging from 20.5 V to 16.0 V and it should be capable of supporting transient pulses during start up and once every hour to support PLSS fan and pump operation. Figure 1 shows the placement of the battery in the backpack area of the EMU suit. The battery and cells will undergo testing under different conditions to understand its performance and safety characteristics.

Jeevarajan, J. A.↗

Reach Envelope and Field of Vision Quantification in Mark III Space Suit Using Delaunay Triangulation

The Science Crew Operations and Utility Testbed (SCOUT) project is focused on the development of a rover vehicle that can be utilized by two crewmembers during extra vehicular activities (EVAs) on the moon and Mars. The current SCOUT vehicle can transport two suited astronauts riding in open cockpit seats. Among the aspects currently being developed is the cockpit design and layout. This process includes the identification of possible locations for a socket to which a crewmember could connect a portable life support system (PLSS) for recharging power, air, and cooling while seated in the vehicle. The spaces in which controls and connectors may be situated within the vehicle are constrained by the reach and vision capabilities of the suited crewmembers. Accordingly, quantification of the volumes within which suited crewmembers can both see and reach relative to the vehicle represents important information during the design process.

Abercromby, Andrew F. J.↗

Thermoelectric Energy Conversion: Future Directions and Technology Development Needs

This viewgraph presentation reviews the process of thermoelectric energy conversion along with key technology needs and challenges. The topics include: 1) The Case for Thermoelectrics; 2) Advances in Thermoelectrics: Investment Needed; 3) Current U.S. Investment (FY07); 4) Increasing Thermoelectric Materials Conversion Efficiency Key Science Needs and Challenges; 5) Developing Advanced TE Components & Systems Key Technology Needs and Challenges; 6) Thermoelectrics; 7) 200W Class Lightweight Portable Thermoelectric Generator; 8) Hybrid Absorption Cooling/TE Power Cogeneration System; 9) Major Opportunities in Energy Industry; 10) Automobile Waste Heat Recovery; 11) Thermoelectrics at JPL; 12) Recent Advances at JPL in Thermoelectric Converter Component Technologies; 13) Thermoelectrics Background on Power Generation and Cooling Operational Modes; 14) Thermoelectric Power Generation; and 15) Thermoelectric Cooling.

theromelectric↗

Chemochromic Hydrogen Leak Detectors

At NASA, hydrogen safety is a key concern for space shuttle processing. Leaks of any level must be quickly recognized and addressed due to hydrogen s lower explosion limit. Chemo - chromic devices have been developed to detect hydrogen gas in several embodiments. Because hydrogen is odorless and colorless and poses an explosion hazard, there is an emerging need for sensors to quickly and accurately detect low levels of leaking hydrogen in fuel cells and other advanced energy- generating systems in which hydrogen is used as fuel. The device incorporates a chemo - chromic pigment into a base polymer. The article can reversibly or irreversibly change color upon exposure to hydrogen. The irreversible pigment changes color from a light beige to a dark gray. The sensitivity of the pigment can be tailored to its application by altering its exposure to gas through the incorporation of one or more additives or polymer matrix. Furthermore, through the incorporation of insulating additives, the chemochromic sensor can operate at cryogenic temperatures as low as 78 K. A chemochromic detector of this type can be manufactured into any feasible polymer part including injection molded plastic parts, fiber-spun textiles, or extruded tapes. The detectors are simple, inexpensive, portable, and do not require an external power source. The chemochromic detectors were installed and removed easily at the KSC launch pad without need for special expertise. These detectors may require an external monitor such as the human eye, camera, or electronic detector; however, they could be left in place, unmonitored, and examined later for color change to determine whether there had been exposure to hydrogen. In one type of envisioned application, chemochromic detectors would be fabricated as outer layers (e.g., casings or coatings) on high-pressure hydrogen storage tanks and other components of hydrogen-handling systems to provide visible indications of hydrogen leaks caused by fatigue failures or other failures in those systems. In another type of envisioned application, chemochromic detectors of this type could be optoelectronically instrumented for monitoring to provide measured digital indications of color changes indicative of the presence of hydrogen.

Roberson, Luke↗

Packing the PLSS

NASA Engineers design spacesuits for ultimate protection and functionality in the extreme environment of space. The spacesuit is often referred to as a "personal spacecraft" because it provides the astronaut with everything he or she needs to survive and work in space outside of the vehicle or habitat. The systems within the spacesuit include the pressure garment system (PGS), the Portable Life Support System (PLSS), and the power, avionics, and software (PAS) system. These elements are necessary to protect crewmembers and allow them to work effectively in the pressure and temperature extremes of space environments. Development of the spacesuit system is necessary to support future human extravehicular exploration activities to Lunar, Martian, microgravity, and possibly other space destinations. Although all the systems that makeup the space suit are important, the PLSS is one of the most complex. The PLSS provides the life support needed by the astronaut and consists of the oxygen (O2) subsystem, ventilation subsystem, and thermal control subsystem. Within each subsystem, there are many different components, a few of which are explained as follows. The oxygen tanks hold the oxygen that the crewmember uses to breath and pressurizes the suit. The primary oxygen tank is responsible during normal operations and the secondary oxygen tank kicks on in the case of an emergency. The Rapid Cycle Amine (RCA) canister is used to remove the carbon dioxide (CO2) and extra humidity in the crewmember's ventilation/breathing gas. The fan moves the oxygen around the suit. Suit Water Membrane Evaporator (SWME) is used within the thermal control loop to cool the water that is used to maintain a comfortable temperature for both the crew member and the other equipment inside the suit. Another component is the battery, which supplies the power needed to operate all these and the many other pieces. The battery is one of the biggest and heavies components within the PLSS. These are just a few of the components that encompass the PLSS. Each component has a weight and a certain volume that the NASA Engineers must take into account when building the PLSS, because the weight and volumes affect the crewmembers center of gravity (CG). [See the Notes Section for the link to an Apollo video that demonstrates the issues some of the crewmembers had picking up tools and dealing with center of gravity/tools on the surface of the Moon.] In this activity, students will simulate engineering design techniques that NASA Engineers and Designers are currently implementing to configuring the components within the PLSS. Through testing, students will consider the comfort, mobility, and center of gravity for their test subjects and how that changes after adjusting the placement of their simulated PLSS components.

Jennings, Mallory↗

Ultrasonic Apparatus for Pulverizing Brittle Material

The figure depicts an apparatus that pulverizes brittle material by means of a combination of ultrasonic and sonic vibration, hammering, and abrasion. The basic design of the apparatus could be specialized to be a portable version for use by a geologist in collecting powdered rock samples for analysis in the field or in a laboratory. Alternatively, a larger benchtop version could be designed for milling and mixing of precursor powders for such purposes as synthesis of ceramic and other polycrystalline materials or preparing powder samples for x-ray diffraction or x-ray fluorescence measurements to determine crystalline structures and compositions. Among the most attractive characteristics of this apparatus are its light weight and the ability to function without need for a large preload or a large power supply: It has been estimated that a portable version could have a mass <0.5 kg, would consume less than 1 W h of energy in milling a 1-cm3 volume of rock, and could operate at a preload <10 N. The basic design and principle of operation of this apparatus are similar to those of other apparatuses described in a series of prior NASA Tech Briefs articles, the two most relevant being Ultrasonic/ Sonic Drill/Corers With Integrated Sensors (NPO-20856), Vol. 25, No. 1 (January 2001), page 38 and Ultrasonic/ Sonic Mechanisms for Deep Drilling and Coring (NPO-30291), Vol. 27, No. 9 (September 2003), page 65. As before, vibrations are excited by means of a piezoelectric actuator, an ultrasonic horn, and a mass that is free to move axially over a limited range. As before, the ultrasonic harmonic motion of the horn drives the free-mass in a combination of ultrasonic harmonic and lower-frequency hammering motion. In this case, the free-mass is confined within a hollow cylinder that serves as a crushing chamber, and the free-mass serves as a crushing or milling tool. The hammering of the free-mass against a material sample at the lower end of the chamber grinds the sample into powder in a relatively short time. The restriction of the free-mass to axial motion only makes the grinding very efficient. The free-mass can be fabricated to have teeth on its lower face to enhance the grinding effect. Optionally, there can be a hole at the bottom of the chamber covered with a sieve to tailor the size distribution of the powder leaving the crushing chamber.

Sherrit, Stewart↗

Solar cell measurements in the field

Portable test instrument makes rapid current, voltage, and power measurements of photovoltaic solar cell arrays in field as well as in laboratory.

Ross, R. G., Jr.↗

Miniaturized physiological data telemetry system

Portable digital physiological data telemetry system uses less power, is more compact, and provides better data integrity than two previous systems designed to similar specifications. It has 13 data channels and two-way voice communication.

Portnoy, W. M.↗

Automated, Ultra-Sterile Solid Sample Handling and Analysis on a Chip

There are no existing ultra-sterile lab-on-a-chip systems that can accept solid samples and perform complete chemical analyses without human intervention. The proposed solution is to demonstrate completely automated lab-on-a-chip manipulation of powdered solid samples, followed by on-chip liquid extraction and chemical analysis. This technology utilizes a newly invented glass micro-device for solid manipulation, which mates with existing lab-on-a-chip instrumentation. Devices are fabricated in a Class 10 cleanroom at the JPL MicroDevices Lab, and are plasma-cleaned before and after assembly. Solid samples enter the device through a drilled hole in the top. Existing micro-pumping technology is used to transfer milligrams of powdered sample into an extraction chamber where it is mixed with liquids to extract organic material. Subsequent chemical analysis is performed using portable microchip capillary electrophoresis systems (CE). These instruments have been used for ultra-highly sensitive (parts-per-trillion, pptr) analysis of organic compounds including amines, amino acids, aldehydes, ketones, carboxylic acids, and thiols. Fully autonomous amino acid analyses in liquids were demonstrated; however, to date there have been no reports of completely automated analysis of solid samples on chip. This approach utilizes an existing portable instrument that houses optics, high-voltage power supplies, and solenoids for fully autonomous microfluidic sample processing and CE analysis with laser-induced fluorescence (LIF) detection. Furthermore, the entire system can be sterilized and placed in a cleanroom environment for analyzing samples returned from extraterrestrial targets, if desired. This is an entirely new capability never demonstrated before. The ability to manipulate solid samples, coupled with lab-on-a-chip analysis technology, will enable ultraclean and ultrasensitive end-to-end analysis of samples that is orders of magnitude more sensitive than the ppb goal given in the Science Instruments.

Mora, Maria F.↗

Low-cost, Risk-Reduction Testing of Class D Spacecraft Photovoltaic Systems

The end-to-end verification of a spacecraft photovoltaic power generation system requires light! A low-cost, portable, and end-to-end photovoltaic-system test appropriate for NASAs new generation of Class D missions is presented. High risk, low-cost, and quick-turn satellites rarely have the resources to execute the traditional approaches from higher-class (A-C) missions. The Class D approach, as demonstrated on the Lunar Atmospheric and Dust Environment Explorer (LADEE), utilizes a portable, metal-halide, theatre lamp for an end-to-end photovoltaic system test. While not as precise and comprehensive as the traditional Large Area Pulsed Solar Simulator (LAPSS) test, the LADEE method leverages minimal resources into an ongoing assessment program that can be applied through numerous stages of the mission. The project takes a true Class D approach in assessing the technical value of a costly, high-fidelity performance test versus a simpler approach with less programmatic risk. The resources required are a fraction of that for a LAPSS test, and is easy to repeat due to its portability. Further, the test equipment can be handed down to future projects without building an on-site facility.At the vanguard of Class D missions, the LADEE team frequently wrestled with and challenged the status quo. The philosophy of risk avoidance at all cost, typical to Class A-C missions, simply could not be executed. This innovative and simple testing solution is contextualized to NASA Class D programs and a specific risk encountered during development of the LADEE Electrical Power System (EPS). Selection of the appropriate lamp and safety concerns are discussed, with examples of test results. Combined with the vendors panel-level data and periodic inspection, the method ensures system integrity from Integration and Test (IT) through launch. Following launch, mission operations tools are utilized to assess system performance based on a scant amount of available data.

photovoltaic↗

Performance Analysis and Portability of the PLUM Load Balancing System

The ability to dynamically adapt an unstructured mesh is a powerful tool for solving computational problems with evolving physical features; however, an efficient parallel implementation is rather difficult. To address this problem, we have developed PLUM, an automatic portable framework for performing adaptive numerical computations in a message-passing environment. PLUM requires that all data be globally redistributed after each mesh adaption to achieve load balance. We present an algorithm for minimizing this remapping overhead by guaranteeing an optimal processor reassignment. We also show that the data redistribution cost can be significantly reduced by applying our heuristic processor reassignment algorithm to the default mapping of the parallel partitioner. Portability is examined by comparing performance on a SP2, an Origin2000, and a T3E. Results show that PLUM can be successfully ported to different platforms without any code modifications.

Oliker, Leonid↗