Search NASA⌕ Search

SEARCH · Search NASA

Results for “position measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Expanding the range of the resolvable strain from distributed fiber optic sensors using a local adaptive reference approach

Optical frequency domain reflectometry (OFDR) is a spectral measurement technique in which shifts in the local Rayleigh backscatter spectra can be used to perform distributed temperature or strain measurements relative to a reference measurement using ordinary single-mode optical fibers. Here, we demonstrate a data processing methodology for improving the resolvable range of temperature and strain by adaptively varying the reference measurement position by position, based on the time evolution of the local optical intensities and the correlation between the reference and active measurements. These methods nearly double the resolvable range of temperature and strain compared with that achieved using the traditional static reference approach.

47 OTHER INSTRUMENTATION↗

Atmospheric neutral points outside of the principal plane

It is noted that the positions in the sky where the skylight is unpolarized, that is, the neutral points, are in most cases located in the vertical plane through the sun (the principal plane). Points have been observed outside the principal plane (Soret, 1888) when the plane intersected a lake or sea. Here, the neutral points were located at an azimuth of about 15 deg from the sun and near the almucantar through the sun. In order to investigate the effects of water surface and aerosols in the neutral point positions, the positions are computed for models of the earth-atmosphere system that simulate the observational conditions. The computed and measured positions are found to agree well. While previous observations provided only qualitative information on the degree of polarization, it is noted that the computations provide details concerning the polarization parameters.

Fraser, R. S.↗

Theoretical method for calculating relative joint geometry of assembled robot arms

Equations are developed to extract the relative joint parameters of an assembled robot arm. Specifically, the Denavit-Hartenberg parameters, which completely characterize the relative joint geometry, are calculated. These parameters are needed to control the hand of the robot arm by resolved rate. As an example, the parameter extraction equations are used with perfect simulated data (no measurement noise) obtained from a mathematical model of a six-degree-of-freedom robot arm. For an actual application, measurement data needed to estimate the relative joint parameters can be generated by moving a robot arm to different positions, measuring the location of the hand (or other extension) in base coordinates, and recording the corresponding joint angles.

Barker, L. K.↗

Bicycle ergometer instrumentation to determine muscle and bone forces during exercise

It is hypothesized that bone loss experienced by astronauts in zero gravity conditions may be curtailed by appropriate exercise. According to Wolf's law, bone regenerates when muscles produce stresses by pulling on the bone during daily activity and/or exercise on Earth. to use this theory to prevent or decrease bone loss, one needs to quantify musculoskeletal loads and relate them to bone density changes. In the context of the space program, it is desirable to determine musculoskeletal loads during exercise (using the bicycle ergometer in this case) so that one may make similar measurements on Earth and in space. In this manner, load measurements on Earth may be used as reference to generate similar loads during exercise in space. The work reported in this document entails a musculoskeletal load measurement system that, when complete, will provide forces at muscle insertion points and other contact points, on bone. This data will be used by Dr. Beth A. Todd, who is also a SSF working with Dr. Shackelford, as input to a finite element model of bone sections to determine stress distributions. A bicycle ergometer has been instrumented to measure parameters needed to determine musculoskeletal forces during exercise. A primary feature of the system is its compactness. It uses small/light sensors without line-of-sight requirements. The system developed includes sensors, signal processing, a data acquisition system, and software to collect the data. The sensors used include optical encoders to measure position and orientation of the pedal (foot), accelerometers to determine kinematic parameters of the shank and thigh, load cells to measure pedal forces on the sagittal plane, and EMG probes to measure muscle activity. The signals are processed using anti-aliasing filters and amplifiers. The sensors' output is digitized using 30 channels of a board mounted inside a 486 class PC. A program sets the data acquisition parameters and collects data during a time period specified by the user. The data is put directly into a file on the hard disk in binary form. The 30 channels are sampled at 200 KHz, and each 30 channel scan is done at a rate of 1000 Hz. The instrumented ergometer has been flown in the KC-135 zero-gravity (zero-g) flight to collect information needed to determine musculoskeletal forces under these conditions. Similar information has been collected in 1-g conditions for comparision with the results from the zero-g case. At this time, the sets of data from both experiments are being processed. An existing methodology will be used to determine the kinematic parameters of the shank and thigh using accelerometer and encoder data. This methodology was developed during the fellow's previous NASA/ASEE fellowship and thanks to a Director's Grant. In the future, a methodology to determine the musculoskeletal forces using Newton's Law of Motion and optimization techniques will be developed to determine forces exerted by particular muscles.

Figueroa, Fernando↗

Beam Measurements of the Tianlai Dish Radio Telescope using an Unmanned Aerial Vehicle

Precision measurement of the beam pattern of an antenna is very important for many applications. While traditionally such measurement is often made in a microwave anechoic chamber or at a test range, measurement using an unmanned aerial vehicle offers a number of advantages: the measurement can be made for the assembled antenna on site, thus reflecting the actual characteristics of the antenna of interest, and more importantly, it can be performed for larger antennas which cannot be steered or easily measured using the anechoic chamber and test range. Here we report our beam measurement experiment with UAV for a 6 meter dish used in the Tianlai array, which is a radio astronomy experiment. Due to the dish's small collecting area, calibration with an astronomical source only allows for determining the antenna beam pattern over a very limited angular range. We describe in detail the setup of the experiment, the components of the signal transmitting system, the design of the flight path and the procedure for data processing. We find the UAV measurement of the beam pattern agrees very well with the astronomical source measurement in the main lobe, but the UAV measurement can be extended to the fourth side lobe. The measured position and width of each lobe also shows good agreement with electromagnetic field simulation. This UAV-based approach of beam pattern measurement is flexible and inexpensive, and the technique may also be applied to other experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stereo Photogrammetry Measurements of the Position and Attitude of a Nozzle-Plume/Shock-Wave Interaction Model in the NASA Ames 9- by 7-Ft Supersonic Wind Tunnel

Stereo photogrammetry was used to measure the position and attitude of a slender body of revolution during nozzle-plume/shock-wave interaction tests in the NASA Ames 9- by 7-Ft Supersonic Wind Tunnel. The model support system was designed to allow the model to be placed at many locations in the test section relative to a pressure rail on one sidewall. It included a streamwise traverse as well as a thin blade that offset the model axis from the sting axis. With these features the support system was more flexible than usual resulting in higher-than-usual uncertainty in the position and attitude of the model. Also contributing to this uncertainty were the absence of a balance, so corrections for sting deflections could not be applied, and the wings-vertical orientation of the model, which precluded using a gravity-based accelerometer to measure pitch angle. Therefore, stereo photogrammetry was chosen to provide independent measures of the model position and orientation. This paper describes the photogrammetry system and presents selected results from the test.

supersonic↗

COD measurements at various positions along a crack

Load versus crack-opening-displacement (COD) was measured at various positions along the border of a fatigue crack as it grew from a small surface crack on the edge of an aluminum specimen into a through-the-thickness crack. Displacements were measured with a laser-based interferometric system with a gage length of 70 microns and a resolution of 0.01 micron. These load-COD curves can be used to determine opening loads and thereby investigate the effect of closure on the growth of small cracks. In general, the opening loads decrease as the crack grows.

Sharpe, W. N., Jr.↗

A constant altitude flight survey method for mapping atmospheric ambient pressures and systematic radar errors

The flight test technique described uses controlled survey runs to determine horizontal atmospheric pressure variations and systematic altitude errors that result from space positioning measurements. The survey data can be used not only for improved air data calibrations, but also for studies of atmospheric structure and space positioning accuracy performance. The examples presented cover a wide range of radar tracking conditions for both subsonic and supersonic flight to an altitude of 42,000 ft.

Larson, T. J.↗

A constant altitude flight survey method for mapping atmospheric ambient pressures and systematic radar errors

The flight test technique described uses controlled survey runs to determine horizontal atmospheric pressure variations and systematic altitude errors that result from space positioning measurements. The survey data can be used not only for improved air data calibrations, but also for studies of atmospheric structure and space positioning accuracy performance. The examples presented cover a wide range of radar tracking conditions for both subsonic and supersonic flight to an altitude of 42,000 ft.

Larson, T. J.↗

NASA Tech Briefs, October 2005

Topics covered include: Insect-Inspired Optical-Flow Navigation Sensors; Chemical Sensors Based on Optical Ring Resonators; A Broad-Band Phase-Contrast Wave-Front Sensor; Progress in Insect-Inspired Optical Navigation Sensors; Portable Airborne Laser System Measures Forest-Canopy Height; Deployable Wide-Aperture Array Antennas; Faster Evolution of More Multifunctional Logic Circuits; Video-Camera-Based Position-Measuring System; N-Type delta Doping of High-Purity Silicon Imaging Arrays; Avionics System Architecture Tool; Updated Chemical Kinetics and Sensitivity Analysis Code; Predicting Flutter and Forced Response in Turbomachinery; Upgrades of Two Computer Codes for Analysis of Turbomachinery; Program Facilitates CMMI Appraisals; Grid Visualization Tool; Program Computes Sound Pressures at Rocket Launches; Solar-System Ephemeris Toolbox; Data-Acquisition Software for PSP/TSP Wind-Tunnel Cameras; Corrosion-Prevention Capabilities of a Water-Borne, Silicone-Based, Primerless Coating; Sol-Gel Process for Making Pt-Ru Fuel-Cell Catalysts; Making Activated Carbon for Storing Gas; System Regulates the Water Contents of Fuel-Cell Streams; Five-Axis, Three-Magnetic-Bearing Dynamic Spin Rig; Modifications of Fabrication of Vibratory Microgyroscopes; Chamber for Growing and Observing Fungi; Electroporation System for Sterilizing Water; Thermoelectric Air/Soil Energy-Harvesting Device; Flexible Metal-Fabric Radiators; Actuated Hybrid Mirror Telescope; Optical Design of an Optical Communications Terminal; Algorithm for Identifying Erroneous Rain-Gauge Readings; Condition Assessment and End-of-Life Prediction System for Electric Machines and Their Loads; Lightweight Thermal Insulation for a Liquid-Oxygen Tank; Stellar Gyroscope for Determining Attitude of a Spacecraft; and Lifting Mechanism for the Mars Explorer Rover.

Source record↗

The Ring Current ENA Instrument on the NASA STORIE Mission

NASA has recently selected the Storm Time O+ Ring current Imaging Evolution (STORIE) mission to study the evolution of Earth’s ring current and the role of composition and dynamics during geomagnetic storms. STORIE addresses this inner magnetospheric science through the use of a Ring current Energetic Neutral Atom (RENA) instrument hosted on the International Space Station (ISS). This novel vantage point for ENA imaging has a number of scientific and implementation advantages. RENA is a high sensitivity remote sensing ENA imager and composition instrument with a field of view of 90 x 2 degrees, and an angular resolution of 2 x 2 degrees. The instrument aperture points zenith and its long dimension is oriented perpendicular to the ISS ram direction. As a result, RENA acts as a “push broom” imager building up a complete sky scan of the ring current in a single 90-minute ISS orbit. The instrument employs electrostatic optics along with a foil-MCP TOF x PHA x Delay-Line position measurement technique to resolve H and O energy spectra in the energy range 10-500 KeV for each look direction. Furthermore, it employs triple+ time and position coincidence to effectively reduce background noise from geocoronal and black sky UV as well as penetrating radiation. The abundant mass, power, and telemetry, resources of the ISS allow for large instrument aperture, very high sensitivity, complex data product and simplified operations, altogether contributing towards a high signal to noise (S/N) measurement.

Space Science↗

Performance Comparison of Circular and Spherical Error Probable Estimators

This report compares the performance of three Circular Error Probable (CEP) estimators: the Grubbs-Patnaik estimator, a new, non-iterative, radial-integration estimator, and a median estimator. It also compares the performance of two Spherical Error Probable (SEP) estimators. The performance of each estimator is assessed in terms of bias, uncertainty, robustness, and computational complexity. Robustness is evaluated with respect to outliers, variations in the underlying statistical distribution characterizing munition impact positions, and impact-position measurement errors. The performance assessments indicate the radial-integration and Grubbs-Patnaik estimators perform nearly identically providing the statistical distribution of impact-position coordinates is jointly normal with zero means. In that case, both estimators outperform the median estimator by about 2% relative to the true CEP in terms of estimator uncertainty. The bias performance of the radial-integration and median estimators is close to zero for jointly normal impacts, however, the Grubbs-Patnaik estimator can be significantly biased for jointly normal impacts with non-zero means. When the statistical distribution characterizing impact positions is known, but not jointly normal, the radial-integration estimator is superior. In this case, the median estimator also outperforms the Grubbs-Patnaik estimator but is not quite as good as the radial-integration estimator. If the statistical distribution characterizing impacts is unknown and not jointly normal, or if distribution parameters are difficult or impractical to estimate, or if test data is corrupted with outliers, then the median estimator dramatically outperforms the other estimators, especially in terms of estimation bias. Unexpectedly, measurement noise did not significantly degrade the performance of any of the estimators, except for cases with signal to noise ratios less than five. Although the Grubbs-Patnaik estimator has remained the gold standard for CEP estimation for over half a century, the performance assessments indicate the new, non-iterative, radial-integration estimator and the median estimator offer significant advantages and, in most practical real-world conditions, are superior estimators. These estimators are also useful for SEP estimation whereas the Grubbs-Patnaik estimator does not extend to three dimensions.

97 MATHEMATICS AND COMPUTING↗

Scanning System Acquires Data At Designated Coordinates

Firmware in computer-controlled electromechanical scanning apparatus enables acquisition of data "on the fly" - as scanning head passes through designated positions on plane. Scanning motion steady, no sacrifice of positional accuracy. Control system has "Interrupt" structure commanding central processing unit to enter data-acquisition routine when x-y table reaches designated measurement positions. Adaptable to systems required to take data, or perform machining operations at designated positions.

Chern, E. James↗

The Longitudinal Properties of a Solar Energetic Particle Event Investigated Using Modern Solar Imaging

We use combined high-cadence, high-resolution, and multi-point imaging by the Solar-Terrestrial Relations Observatory (STEREO) and the Solar and Heliospheric Observatory to investigate the hour-long eruption of a fast and wide coronal mass ejection (CME) on 2011 March 21 when the twin STEREO spacecraft were located beyond the solar limbs. We analyze the relation between the eruption of the CME, the evolution of an Extreme Ultraviolet (EUV) wave, and the onset of a solar energetic particle (SEP) event measured in situ by the STEREO and near-Earth orbiting spacecraft. Combined ultraviolet and white-light images of the lower corona reveal that in an initial CME lateral "expansion phase," the EUV disturbance tracks the laterally expanding flanks of the CME, both moving parallel to the solar surface with speeds of approx 450 km/s. When the lateral expansion of the ejecta ceases, the EUV disturbance carries on propagating parallel to the solar surface but devolves rapidly into a less coherent structure. Multi-point tracking of the CME leading edge and the effects of the launched compression waves (e.g., pushed streamers) give anti-sunward speeds that initially exceed 900 km/s at all measured position angles. We combine our analysis of ultraviolet and white-light images with a comprehensive study of the velocity dispersion of energetic particles measured in situ by particle detectors located at STEREO-A (STA) and first Lagrange point (L1), to demonstrate that the delayed solar particle release times at STA and L1 are consistent with the time required (30-40 minutes) for the CME to perturb the corona over a wide range of longitudes. This study finds an association between the longitudinal extent of the perturbed corona (in EUV and white light) and the longitudinal extent of the SEP event in the heliosphere.

acceleration of particles↗

Ground noise measurements during landing, take-off, and flyby operations of a four-engine turbopropeller STOL airplane

Noise measurements were obtained for a four-engine turbopropeller STOL airplane during a Federal Aviation Administration flight evaluation program at the National Aviation Facilities Experimental Center. These noise measurements involved landing-approach, takeoff-climbout, and flyby operations of the airplane. A total of 13 measuring positions were used to define the noise characteristics around a simulated STOL port. The results are presented in the form of both physical and subjective measurements. An appendix is included to present tabulated values of various subjective reaction units which may be significant for the planning and operation of STOL ports. The main source of noise produced by this vehicle was found to be the propeller, and noise levels decrease generally in accordance with the inverse-distance law for distances up to about 457 meters. For similar slant ranges, somewhat lower noise levels were experienced during flyby than during takeoff or landing.

Hilton, D. A.↗

Positive ion observations in the middle magnetosphere of Jupiter

The positive ion data gathered by the Voyager Plasma Science experiment in the middle magnetosphere of Jupiter are considered. It is pointed out that the experiment measures positive ions with energies per charge between 10 and 5950 V. The observations are analyzed to derive the mass and charge densities, velocity components, and temperatures of the low-energy plasma population. The reduced data set is discussed in terms of the outstanding questions concerning this plasma population and its dynamics. It is found that on the dayside there exists a transonic to highly supersonic positive ion population which tends to move azimuthally but does not rigidly corotate with the planet.

Mcnutt, R. L., Jr.↗

Characterization of Ablation Product Radiation Signatures of PICA and FiberForm

Emission spectroscopy measurements in the post-shock layer in front of low density ablative material samples of different shapes were obtained in the NASA Langley HYMETS arcjet facility. A horizontal line of measurement positions was imaged on the entrance slit of the spectrometer allowing detection of the entire stagnation line in front of the samples. The stagnation line measurements were used to compare the post-shock layer emission signatures in front of PICA and FiberForm. The emission signatures of H, NH, and OH are characteristic for pyrolysis gases and consequently were only observed in front of the PICA samples. CN and C were found in front of both materials and are mainly due to interactions of the carbon fibers with the plasma. In all tests with instrumented samples, the emission of Mn, Cr, and Ni was observed when the thermocouple temperatures reached or exceeded ~1,500 K, strongly indicating erosion of the molten thermocouple tips. Temperatures in the post-shock layer were estimated from comparing the CN band emission to spectral simulation. The resulting rotational and vibrational temperatures were on the order of 7,000 to 9,000 K and close to each other indicating a plasma condition close to equilibrium. In addition to the stagnation line configurations, off-axis lines of observation were investigated to gather information about spalled particles in the flow. From a comparison of measured continuum emission with simulated Planck radiation, average particle temperatures along the measured line of observation were determined for two cases. Particle temperatures between 3,500 and 2,000 K were found. A comprehensive investigation of the entire amount of data set is ongoing.

Winter, Michael↗