Search NASA⌕ Search

SEARCH · Search NASA

Results for “position measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

GPS Measurements of Precipitable Water Vapor Can Improve Survey Calibration: A Demonstration from KPNO and the Mayall z -band Legacy Survey

Dual-band Global Positioning Satellite (GPS) measurements of precipitable water vapor (PWV) at the Kitt Peak National Observatory predict the overall per-image sensitivity of the Mayall z-band Legacy Survey (MzLS). The per-image variation in the brightness of individual stars is strongly correlated with the measured PWV and the color of the star. Synthetic stellar spectra through TAPAS transmission models successfully predict the observed PWV-induced photometric variation. We find that PWV absorption can be well approximated by a linear relationship with (airmass × PWV) 0.6 and present an update on the traditional treatment in the literature. The MzLS zero-point sensitivity in electrons s –1 varies with a normalized-mean absolute deviation of 61 mmag. PWV variation accounts 23 mmag of this zero-point variation. The MzLS per-image absolute sensitivity decreases by 40 mmag per effective mm of PWV. The overall gray offset portion of this variation is corrected by the calibration to a reference catalog. But the relative calibration error between blue (r – z < 0.5 mag) versus red (1.2 mag < r – z) stars increases by 0.3–2 mmag per effective mm of PWV. We argue that GPS systems provide more precise PWV measurements than using differential measurements of stars of different colors and recommend that observatories install dual-band GPS as a low-maintenance, low-cost, auxiliary calibration system. We extend our results of the need for well-calibrated PWV measurements by presenting the calculations of the PWV photometric impact on three science cases of interest: stellar photometry, supernova cosmology, and quasar identification and variability.

79 ASTRONOMY AND ASTROPHYSICS↗

Demonstration of sub-micron UCN position resolution using room-temperature CMOS sensor

High spatial resolution of ultracold neutron (UCN) measurement is of growing interest to UCN experiments such as UCN spectrometers, UCN polarimeters, quantum physics of UCNs, and quantum gravity. Here we utilize physics informed deep learning to enhance the experimental position resolution and to demonstrate sub-micron spatial resolutions for UCN position measurements obtained using a room-temperature CMOS sensor, extending our previous work that demonstrated a position uncertainty of 1.5 microns. We explore the use of the open-source software Allpix Squared to generate experiment-like synthetic hit images with ground-truth position labels. We use physics-informed deep learning by training a fully connected neural network (FCNN) to learn a mapping from input hit images to output hit position. The automated analysis for sub-micron position resolution in UCN detection combined with the fast data rates of current and next generation UCN sources will enable improved precision for future UCN research and applications.

10B nanometer thin film↗

Thickness and uniformity mapping of thin foils using resistive silicon detectors

Alpha energy loss is a common tool used for measuring target thicknesses. However, these measurements are often made without position information, which either forfeits knowledge of material uniformity and local thickness or requires a prohibitive number of measurements per target to partially recover this information. In consideration of this, a method for measuring position-dependent thicknesses is described in this work; by using the position-sensitivity of the dual-axis duo-lateral (DADL) silicon detector, thicknesses across the entire face of the material can be measured to sub-mm precision with a single measurement. Several examples are presented using a number of targets with varying characteristics, which altogether demonstrate the precision, accuracy, and versatility of this technique.

Foil uniformity↗

Solvation governs cation transference in glyme-based lithium battery electrolytes

The efficacy of electrochemical systems is governed by the cation transference number, which represents the fraction of current carried by the working ion. Energy is wasted when field-induced motion also drives anions and solvent molecules, decreasing the transference number to near-zero. We present a systematic study of cation transference in a series of electrolytes: tetraglyme (TG), octaglyme (OG), and poly(ethylene oxide) (PEO) mixed with lithium bis(trifluoromethanesulfonyl)imide. In all three electrolytes, starting from the dilute salt concentration limit, the experimentally measured cation transference number decreases with increasing concentration, reaching a minimum between -0.1 and -0.2, before rising back to positive values. Explicit measurements of field-induced species' velocities by electrophoretic nuclear magnetic resonance indicate that negative cation transference numbers in TG and OG electrolytes are dictated by solvation interactions with minimal contribution from anion-cation interactions. Simulation-based solvation structures indicate that OG serves as a bridge between TG and PEO. Multi-charge positive clusters, which are negligible in TG, become increasingly important at higher chain lengths (OG and PEO). As migrating cations drag their solvation shells, this solvation-induced motion is amplified in glyme electrolytes because of covalent interactions between solvating glyme molecules and free glyme molecules.

Im, Julia↗

Estimated capital costs of fish exclusion technologies for hydropower facilities

Hydropower is a reliable source of renewable energy, and its future expansion is likely to be in the form of either smaller new stream development (NSD) projects or powering existing non-powered dams. Thresholds for entrainment risk to fish and the requirements for fish exclusion at hydropower facilities often differ depending on the species involved, the characteristics of the facility, and the goals of stakeholders, but little quantitative information is present within the literature regarding the specific costs of fish exclusion measures. Cost data associated with protection, mitigation, and enhancement (PM&E) measures related to positive barrier screening were identified using keyword searches of an existing environmental mitigation cost data set and manual extraction from regulatory licensing documents available in the Federal Energy Regulatory Commission (FERC) eLibrary. This approach yielded a total of 50 p.m.&E mitigation measures with estimated capital construction costs pertaining to positive barrier screens and represented <10% of the 171 total FERC project dockets available in the data set. These data were highly skewed toward conventional relicensing projects, as <7% were associated with NSD projects. Results indicate highly variable costs are associated with fish screening, with flow-normalized costs one to two orders of magnitude higher for screening with the highest exclusion capability (≤0.09 in. spacing) compared with coarser screening (1–2 in.). These data provide an initial baseline for estimating exclusion costs for hydropower development and may help developers consider options for more fish-friendly generation technologies, though gaps remain relating to a lack of data, particularly for NSD projects.

13 HYDRO ENERGY↗

Electron beam characterization via quantum coherent electric field imaging

We demonstrate an all-optical, minimally invasive electron beam (𝑒−beam) characterization using Rydberg electrometry. An 𝑒-beam passes through a localized detector volume containing thermal Rb atoms that are optically excited in a quantum superposition of ground and Rydberg states. The 𝑒-beam's electric field perturbs atomic coherence and modifies resonance fluorescence in a narrow spectral region near the two-photon optical transition. Imaging Rb fluorescence provides a map of the electric field from the 𝑒-beam via Rydberg state Stark shifts and allows us to reconstruct the 𝑒-beam width, centroid position, and current. For an 𝑒-beam of 20 keV and electron currents of 20–40 µ⁢A, we measured the centroid position with an accuracy of ≤ 8 µ⁢m and width to within 100 µ⁢m, limited by the experimental sensitivity of electric field reconstruction of ∼0.02 V/cm. This method is suitable for a wide range of electron energies and currents, and can be adopted for nuclear and high-energy experiments for minimally invasive real-time diagnostics and profiling of charged particle beams.

Behary, Rob [College of William and Mary, Williams↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated tracking of prefabricated components for areal-time evaluator to optimize and automateinstallation

Trade associations for prefabricated construction estimate that about 50% of prefabricated wall projects have alignment problems that lead to defects and rework. Additionally, component installation times average between 30 and 60 minutes per component. To address these issues, a real-time evaluator (RTE) system was introduced to decrease cost and automate prefabricated component installation by reducing the installation time, decreasing rework, and enhancing energy performance through higher installation quality. The RTE uses commonly available hardware and software to perform autonomous tracking to measure the real-time location and orientation of components as they are crane-lifted and installed. The hardware, software, and algorithms that allow the autonomous tracking of components are detailed. An algorithm to automate the initial search for a component with three attached retroreflectors is proposed. Algorithms to automate the measurement of component position and orientation are also proposed. Simple lab-scale proof-of-concept experiments were conducted to assess the algorithms for automation of component searching, measurement of real-time movement, and measurement of component orientation. With additional development, the system can be used as a tool to generate the commands for autonomous crane operation or single-task construction robots.

Hayes, Nolan↗

Uncertainty amplification due to density/refractive index gradients in background-oriented schlieren experiments

Here, we theoretically analyze the effect of density/refractive index gradients on the measurement precision of background-oriented schlieren (BOS) experiments by deriving the Cramer–Rao lower bound (CRLB) for the 2D centroid estimation process. A model is derived for the diffraction limited image of a dot viewed through a medium containing density gradients that includes the effect of the experimental parameters such as the magnification and f-number. It is shown using the model that nonlinearities in the density gradient field lead to blurring of the dot image. This blurring amplifies the effect of image noise on the centroid estimation process, leading to an increase in the CRLB and a decrease in the measurement precision. The ratio of position uncertainties of a dot in the reference and gradient images is shown to be a function of the ratio of the dot diameters and dot intensities. We termed this parameter the amplification ratio (A F ), and a methodology for reporting position uncertainties in tracking-based BOS measurements is proposed. The theoretical predictions of the dot position estimation variance from the CRLB are compared to ray tracing simulations, and agreement is obtained. The uncertainty amplification is also demonstrated on experimental BOS images of flow induced by a spark discharge, where it is seen that regions of high amplification ratio correspond to regions of density gradients. This analysis elucidates the dependence of the position uncertainty on density and refractive index gradient-induced distortion parameters, provides a methodology for accounting its effect on uncertainty quantification and provides a framework for optimizing experiment design.

42 ENGINEERING↗

Liquid Core Detection and Strand Condition Monitoring in a Continuous Caster Using Optical Fiber

Real-time monitoring of the liquid core position during the continuous casting of steel has been demonstrated using low-cost distributed optical-fiber-based strain sensors. These sensors were installed on the containment roll support structures in the segments of a production continuous caster to detect the position of the solid–liquid interface and monitor the strand condition during the continuous casting. Distributed Fiber Bragg Grating sensors (FBGs) were used in this work to monitor strain at six roll positions in the caster. The sensor performance was first validated by comparing optical strain measurements with conventional strain gauge measurements in the lab. Next, optical strain measurements were performed on an isolated caster segment in a segment maintenance facility using hydraulic jacks to simulate the presence of a liquid core under the roll. Finally, the sensors were evaluated during caster operation. The sensors successfully detected the load increase associated with the presence of a liquid core under each instrumented roll location. Incidents of bulging and roll eccentricity were also detected using frequency analysis of the optical strain signal. The liquid core position measurements were compared using predictions from computer models (digital twins) in use at the production site. The measurements were in good agreement with the model predictions, with a few exceptions. Under certain transient caster operating conditions, such as spraying practice changes and SEN exchanges, the model predictions deviated slightly from the liquid core position determined from strain measurements.

47 OTHER INSTRUMENTATION↗

Design and commissioning of resistive foil bolometer diagnostics on the ST40 tokamak

Following successful campaigns on the compact high field spherical tokamak ST40, resistive gold foil bolometers have now been installed to measure the radiated power profile. Positioned on the midplane, two bolometer cameras offer perspectives of the horizontal and vertical planes, while the third camera, situated above the midplane, provides a vertical view of the top divertor plates, including the X-point and the strike points. Further, these cameras use a commercial off-the-shelf data acquisition platform with modules specifically designed for bolometers in a Wheatstone bridge configuration, providing both phase sensitive detection and in situ calibration. This paper presents an overview of the design and functionality of all three cameras and the commissioning of the horizontal plane camera. The commissioning of the horizontal camera shows data from a range of plasma pulses, presenting a positive correlation between the relative profiles measured from the bolometer camera and an absolute extreme ultraviolet diode camera viewing along similar lines of sight.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sampling synchronization through GPS signals

A method uses a distributed data acquisition system with multiple, physically unconnected, data acquisition units, that can be in wireless communication with a remote host, to timestamp measurement data with sub-microsecond time base accuracy of sampling clock relative to an absolute timeframe. A current absolute time is derived from messages received from a satellite radio beacon positioning system (GPS). Measurement data is sampled by each unit at a specified sampling rate. Using hardware logic, batches of sampled data are associated with corresponding timestamps representing the absolute time at which the data was sampled. Data and timestamps may be transmitted to the host. A time offset bias is compensated by comparing timestamps against a nominal time based on start time and nominal sampling rate. The sampling clock rate may be disciplined using time pulses from the GPS receiver. An initial start of data sampling by all units can also be synchronized.

Zhuge, James Q.↗

High-power non-perturbative laser delivery diagnostics at the final focus of 100-TW-class laser pulses

Controlling the delivery of multi-terawatt and petawatt laser pulses to final focus, both in position and angle, is critical to many laser applications such as optical guiding, laser–plasma acceleration, and laser-produced secondary radiation. We present an online, non-destructive laser diagnostic, capable of measuring the transverse position and pointing angle at focus. The diagnostic is based on a unique double-surface-coated wedged-mirror design for the final steering optic in the laser line, producing a witness beam highly correlated with the main beam. By propagating low-power kilohertz pulses to focus, we observed spectra of focus position and pointing angle fluctuations dominated by frequencies below 70 Hz. The setup was also used to characterize the excellent position and pointing angle correlation of the 1 Hz high-power laser pulses to this low-power kilohertz pulse train, opening a promising path to fast non-perturbative feedback concepts even on few-hertz-class high-power laser systems.

47 OTHER INSTRUMENTATION↗

Spatiotemporal measurements of striations in a glow discharge’s positive column using laser-collisional induced fluorescence

Here we have observed the behavior of striations caused by ionization waves propagating in low-pressure helium DC discharges using the non-invasive laser-collision induced fluorescence (LCIF) diagnostic. To achieve this, we developed an analytic fit of collisional radiative model (CRM) predictions to interpret the LCIF data and recover quantitative two-dimensional spatial maps of the electron density, n e , and the ratios of LCIF emission states that can be correlated with T e with the use of accurate distribution functions at localized positions within striated helium discharges at 500 mTorr, 750 mTorr, and 1 Torr. To our knowledge, these are the first spatiotemporal, laser-based, experimental measurements of n e in DC striations. The n e and 447:588 ratio distributions align closely with striation theory. Constriction of the positive column appears to occur with decreased gas pressure, as shown by the radial n e distribution. We identify a transition from a slow ionization wave to a fast ionization wave between 750 mTorr and 1 Torr. These experiments validate our analytic fit of n e , allowing the implementation of an LCIF diagnostic in helium without the need to develop a CRM.

42 ENGINEERING↗

Snow ALbedo eVOlution (SALVO) Campaign Oblique Photos from April - June, 2024 in Utqiagivk, AK

While albedo line measurements were being made, oblique photos were taken from eye level (~1.8 m) of the position of each albedo measurement (i.e., at 5-meter intervals along the line). The photo numbers were recorded in a notebook and in the ASD notes documents (see the spectral albedo archive). The photos were subsequently renamed for archiving according to the following file naming convention: ‘salvo_[site]_line_oblique_[YYYYMMDD]_[pos]_[rep].JPG’, where [site] is the overall measurement site (‘arm’, ‘beo’, or ‘ice’); YYYYMMDD is the date of the measurement in AKDT (local time); [pos] is the position along the line in meters; and [rep] is the repetition number if repeat photographs were made. Oblique photos are available for almost every albedo measurement.

54 ENVIRONMENTAL SCIENCES↗

IPC-Fusion (Infrastructure Perception and Control (IPC): Multisensor Data Fusion Software) [SWR-25-153]

As part of the National Laboratory of the Rockies' (NLR’s) Infrastructure Perception and Control Laboratory, the IPC-Fusion toolkit provides a probabilistic, scalable, multi-sensor fusion framework that integrates (late-stage fusion) heterogeneous object detection data from traffic sensors to enable robust, real-time tracking of roadway occupants. The algorithmic design of the toolkit is motivated by the need for creating a digital twin of traffic at the edge in a scalable and affordable manner. The software operates by combining object-level measurements (such as position and velocity) from a suite of sensors (such as radar, lidar, camera) using Kalman filtering and probabilistic data association techniques to overcome individual sensor limitations and achieve superior tracking performance in complex traffic zones. The framework addresses key challenges including heterogeneous measurement uncertainties, asynchronous data streams, varying spatiotemporal data resolutions, robust data association, and adaptive object lifecycle management. Validated on real-world traffic intersection data including vehicles and pedestrians, IPC-Fusion demonstrates enhanced tracking reliability across scenarios involving occlusions, sensor failures, and varying traffic densities, supporting the broader IPC initiative's goal of transforming transportation infrastructure through advanced perception capabilities for intelligent transportation systems, traffic safety applications, and autonomous vehicle support.

Sandhu, Rimple [National Laboratory of the Rockies↗

Is the Kok effect a respiratory phenomenon? Metabolic insight using 13 C labeling in Helianthus annuus leaves

The Kok effect is a well-known phenomenon in which the quantum yield of photosynthesis changes abruptly at low light. This effect has often been interpreted as a shift in leaf respiratory metabolism and thus used widely to measure day respiration. However, there is still no formal evidence that the Kok effect has a respiratory origin. Here, both gas exchange and isotopic labeling were carried out on sunflower leaves, using glucose that was 13 C-enriched at specific C-atom positions. Position-specific decarboxylation measurements and NMR analysis of metabolites were used to trace the fate of C-atoms in metabolism. Decarboxylation rates were significant at low light (including above the Kok break point) and increased with decreasing irradiance below 100 µmol photons m –2 s –1 . The variation in several metabolite pools such as malate, fumarate or citrate, and flux calculations suggest the involvement of several decarboxylating pathways in the Kok effect, including the malic enzyme. Our results show that day respiratory CO 2 evolution plays an important role in the Kok effect. Furthermore, the increase in the apparent quantum yield of photosynthesis below the Kok break point is also probably related to malate metabolism, which participates in maintaining photosynthetic linear electron flow.

54 ENVIRONMENTAL SCIENCES↗

WHOLESCALE: Coordinates of wells at San Emidio, Nevada

This dataset includes position coordinates and elevation information for wells at the WHOLESCALE San Emidio project location. Well positions in the attached file are characterized by UTM coordinates (Easting, Northing) in meters, and WHOLESCALE coordinates (Easting, Northing) relative in meters from a chosen reference point. The elevation of the top and bottom of open intervals within each well (representing locations of perforated or open-hole sections) are measured in meters (positive) above WGS84 geoid (mean sea level). The WHOLESCALE acronym stands for Water & Hole Observations Leverage Effective Stress Calculations and Lessen Expenses. The goal of the WHOLESCALE project is to simulate the spatial distribution and temporal evolution of stress in the geothermal system at San Emidio in Nevada, United States.

15 GEOTHERMAL ENERGY↗