Search NASA⌕ Search

SEARCH · Search NASA

Results for “power converter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The Electromagnetic Compatibility (EMC) Design Challenge for Scientific Spacecraft Powered by a Stirling Power Converter

A 55 We free-piston Stirling Technology Demonstration Convertor (TDC) has been tested as part of an evaluation to determine its feasibility as a means for significantly reducing the amount of radioactive material required compared to Radioisotope Thermoelectric Generators (RTGs) to support long-term space science missions. Measurements were made to quantify the low frequency magnetic and electric fields radiated from the Stirling's 80 Hertz (Hz) linear alternator and control electronics in order to determine the magnitude of reduction that will be required to protect sensitive field sensors aboard some science missions. One identified "Solar Probe" mission requires a 100 dB reduction in the low frequency magnetic field over typical military standard design limits, to protect its plasma wave sensor. This paper discusses the electromagnetic interference (EMI) control options relative to the physical design impacts for this power system, composed of 3 basic electrical elements. They are (1) the Stirling Power Convertor with its linear alternator, (2) the power switching and control electronics to convert the 90 V, 80 Hz alternator output to DC for the use of the spacecraft, and (3) the interconnecting wiring including any instrumentation to monitor and control items 1 and 2.

Sargent, Noel B.↗

Gas-to-hydraulic power converter

A gas piston driven hydraulic piston pump is described in which the gas cycle is of high efficiency by injecting the gas in slugs at the beginning of each power stroke. The hydraulic piston is disposed to operate inside the as piston, and the two pistons, both slidably but nonrotatably mounted, are coupled together with a rotating but non-sliding motion transfer ring extending into antifriction grooves in the sidewalls of the two pistons. To make the hydraulic piston move at a constant speed during constant hydraulic horsepower demand and thus exert a constant pressure on the hydraulic fluid, these grooves are machined with variable pitches and one is the opposite of the other, i.e., the gas piston groove increases in pitch during its power stroke while the hydraulic piston groove decreases. Any number of piston assembly sets may be used to obtain desired hydraulic horsepower.

Galloway, C. W.↗

Quantifying Dynamic On-State Resistance of GaN HEMTs for Power Converter Design via a Survey of Low and High Voltage Devices

Designing and optimizing high switching frequency, ultra-efficient converters requires detailed knowledge of the behavior and parasitic parameters for both active and passive components. Recently, wide bandgap transistors have enabled simultaneous increases in both switching frequency and efficiency due to higher maximum operating junction temperature limits, lower dc on-state resistances, and reduced parasitic inductances and capacitances. Yet, the early acceptance of gallium-nitride (GaN) switches was plagued by detrimental dynamic on-state resistance effects. This complex phenomenon for GaN devices is characterized by deviations in on-state resistance from dc operating characteristics based on design choices such as the magnitude and duration of both voltage and current stress, switching mode, and junction temperature. While device manufacturers have made improvements compared to early generation devices, experimental evidence from a survey of commercial GaN transistors highlight measurable change in on-state resistance still exists due to variations in voltage stress during hard-switching operation. After sharing insights for obtaining low noise measurements, an analysis method along with two metrics are proposed to characterize dynamic on-state resistance measurements for power electronics designers. Furthermore, quantifying the performance of GaN devices with standardized metrics facilitates a fair comparison between different GaN device technologies during converter development, enables manufacturing qualification for GaN switches, and provides a benchmark to catalyze improvement for the next generation of GaN device development.

14 SOLAR ENERGY↗

High-power converters for space applications

Phase 1 was a concept definition effort to extend space-type dc/dc converter technology to the megawatt level with a weight of less than 0.1 kg/kW (220 lb./MW). Two system designs were evaluated in Phase 1. Each design operates from a 5 kV stacked fuel cell source and provides a voltage step-up to 100 kV at 10 A for charging capacitors (100 pps at a duty cycle of 17 min on, 17 min off). Both designs use an MCT-based, full-bridge inverter, gaseous hydrogen cooling, and crowbar fault protection. The GE-CRD system uses an advanced high-voltage transformer/rectifier filter is series with a resonant tank circuit, driven by an inverter operating at 20 to 50 kHz. Output voltage is controlled through frequency and phase shift control. Fast transient response and stability is ensured via optimal control. Super-resonant operation employing MCTs provides the advantages of lossless snubbing, no turn-on switching loss, use of medium-speed diodes, and intrinsic current limiting under load-fault conditions. Estimated weight of the GE-CRD system is 88 kg (1.5 cu ft.). Efficiency of 94.4 percent and total system loss is 55.711 kW operating at 1 MW load power. The Maxwell system is based on a resonance transformer approach using a cascade of five LC resonant sections at 100 kHz. The 5 kV bus is converted to a square wave, stepped-up to a 100 kV sine wave by the LC sections, rectified, and filtered. Output voltage is controlled with a special series regulator circuit. Estimated weight of the Maxwell system is 83.8 kg (4.0 cu ft.). Efficiency is 87.2 percent and total system loss is 146.411 kW operating at 1 MW load power.

Park, J. N.↗

Multiagent-Based Dynamic Voltage Support of Power Converters During Fault Ride-Through

Reference point of applicability (RPA) is a predefined point in a distribution network that performance requirements shall apply. As RPA is not directly controlled by a dedicated distributed energy resource (DER), it requires an aggregate response of multiple DERs over a complex meshed network. Here, this article presents a multiagent-based distributed dynamic voltage support (DDVS) method for coordinated aggregate response of multiple DER units to support RPA voltage profile during and after fault ride-through. DDVS implements a multiagent-based leader target tracking scheme with velocity matching and flock centering features to avoid uncoordinated current injections of cooperative DERs. The DDVS is an event-based approach based on RPA requirements. Two-dimensional voltage support objective is handled: 1) coordinated positive sequence current injection for voltage magnitude boosting and 2) coordinated negative sequence current injection for unbalance voltage mitigation. The results demonstrate that the proposed DDVS algorithm addresses emerging coordinated DVS requirement of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Niowave Flow Testing of the High Power Converter - FY 21

Design work for a 100 kW converter to produce a neutron flux via electron impact on a flowing stream of liquid metal lead-bismuth (LBE) was conducted in FY20. In FY21, the focus shifted to a 20 kW converter which was designed in collaboration with Niowave engineers. A flow visualization model is needed to validate model results for the 20 kW converter and ensure adequate coolant flow over containment structures. This work highlights the mockup that was made with quartz side plates by LANL.

42 ENGINEERING↗

Niowave Design and Analysis of a High Power Converter - FY 21

LANL provided support to Niowave Inc. on the design and analysis of the Mk. 4 and Mk. 5, 20 kW converter. The Mk. 4 converter design consisted of lead bismuth eutectic (LBE) flowing over a divider plate to create a waterfall. Niowave, with feedback from LANL, improved on the Mk.4 divider plate and “horn” region of the converter to create the Mk. 5 version of the converter.

42 ENGINEERING↗

Time domain modelling and stability analysis of an integral pulse frequency modulated dc to dc power converter

Using state variable representation a nonlinear, discrete-time system is derived that models the converter exactly. This system is linearized about its steady state solution, and converter stability, transient response and audio susceptibility are studied. The steady state solution of the converter is stable if and only if all the roots of the linearized system are absolutely less than unity. Excellent agreement with laboratory test data has been observed.

Iwens, R. P.↗

A nonsaturating dc-to-dc parallel power converter

Device is conventional circuit modified with pair of diode rectifiers coupled to switching transistors via feedback winding. Transient-causing collector-current overlap between transistors is eliminated. Technique may be used with nonsaturating parallel-transistor converters operating from voltage source which remains fixed or varies over small range.

Lavigna, T.↗