Search NASA⌕ Search

SEARCH · Search NASA

Results for “power system stability assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Dynamic land use implications of rapidly expanding and evolving wind power deployment

Abstract The expansion of wind power poses distinct and varied geographic challenges to a sustainable energy transition. However, current knowledge of its land use impacts and synergies is limited by reliance on static characterizations that overlook the role of turbine technology and plant design in mediating interactions with the environment. Here, we investigate how wind technology development and innovation have shaped landscape interactions with social and ecological systems within the United States and contribute to evolving land area requirements. This work assesses trends in key land use facets of wind power using a holistic set of metrics to establish an evidence base that researchers, technology designers, land use managers, and policymakers can use in envisioning how future wind-intensive energy systems may be jointly optimized for clean energy, social, and environmental objectives. Since 2000, we find dynamic land occupancy patterns and regional trends that are driven by advancing technology and geographic factors. Though most historical U.S. wind deployment has been confined to the temperate grassland biome in the nation’s interior, regional expansion has implicated diverse land use and cover types. A large percentage of the typical wind plant footprint (∼96% to > 99%) is not directly impacted by permanent physical infrastructure, allowing for multiple uses in the spaces between turbines. Surprisingly, turbines are commonly close to built structures. Moreover, rangeland and cropland have supported 93.4% of deployment, highlighting potential synergies with agricultural lands. Despite broadly decreasing capacity densities, offsetting technology improvements have stabilized power densities. Land use intensity, defined as the ratio of direct land usage to lifetime power generation of wind facilities, has also trended downwards. Although continued deployment on disturbed lands, and in close proximity to existing wind facilities and other infrastructure, could minimize the extent of impacts, ambitious decarbonization trajectories may predispose particular biomes to cumulative effects and risks from regional wind power saturation. Increased land-use and sustainability feedback in technology and plant design will be critical to sustainable management of wind power.

17 WIND ENERGY↗

Energy storage planning for enhanced resilience of power systems against wildfires and heatwaves

Extreme weather events pose significant risks to power grid stability due to their severe consequences and potential for widespread failures. Energy storage systems hold great potential for enhancing grid resilience against such events by providing reliable power during peak demand periods. However, accurately quantifying the size, location, and investment costs of new energy storage assets is a complex task, as energy storage planning decisions depend on the investment choices of other generation technologies and the integration of new transmission projects. Here, this paper presents a novel capacity expansion planning framework that simultaneously optimizes investments in energy storage, generation, and transmission, determining their optimal size, location, and type, while incorporating extreme weather events into long-term planning. More specifically, our stress-event-informed planning framework integrates the impact of heatwaves and wildfires into the planning process, identifying least-cost investment solutions that comply with policy goals and enhance grid resilience. The proposed framework employs machine-learning-based modeling to project heatwave-induced loads and performance-based risk assessment to evaluate wildfire-driven transmission line derates. Using industry-standard datasets to accurately represent the transmission topology of the Western Interconnection (WI) system, the proposed framework is applied to the WI 40-zone system, with investment decisions reported for the years 2030, 2035, and 2040. Simulation results reveal that with just a 10% increase in investment costs, resilience against extreme events can be significantly improved, with investment decisions heavily favoring energy storage, particularly 4-hour energy storage systems.

25 ENERGY STORAGE↗

Controller-Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System With Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). This CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Irradiation of ultrasonic sensors and adhesive couplants for application in light water reactor primary loop piping and components

The Electric Power Research Institute (EPRI) Nuclear Sector and US Department of Energy Light Water Reactor Sustainability Program are committed to engaging in research and development endeavors to address materials aging issues specific to long term operation of light water power reactors. To this effect, EPRI launched an industry initiative to develop nondestructive evaluation systems for online monitoring of existing cracks in light water reactor primary coolant loop piping and components. One of the goals of this initiative is to develop a sensor system (or systems) that can determine nondestructively if cracks are growing or arrested and, in the case of the former, to characterize their growth rates. A missing component of this initiative is an experimental assessment of how sensors and adhesive couplants will perform in service when exposed to chronic energetic neutron radiation, particularly at the primary coolant loop hot and cold leg dissimilar metal welds, which join the primary loop piping to the reactor pressure vessel and reside in the vicinity of the reactor core. The objective of this experimental study was to determine how ultrasonic transducers and adhesive couplants perform when exposed to irradiation in a test reactor to simulate and accelerate in-service exposure. Further, to achieve this objective, the signal stability of piezoelectric transducers and performance of adhesive couplants as a function of accumulated fast neutron fluence were characterized by collecting ultrasonic data in-situ during irradiation. Of particular interest were the ultrasonic signal quality and time decay of the amplitude of acoustic reflections as a function of fast neutron fluence. The results of the study showed that, of the 8 transducer/substrate sample assemblies tested, only 3 generated usable ultrasonic signals through the conclusion of the irradiation campaign. It was found that high temperature epoxy tends to ultrasonically couple the sensors to the substrates better than three types of refractory ceramic cements studied, as is supported by post irradiation examination. The results obtained through this experimental study will be utilized in the achievement of the overall goal of development of a sensor system to perform online monitoring of primary loop components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters: Preprint

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

PHIL Interface Design for Use With a Voltage-Regulated Amplifier

Power hardware-in-the-loop (PHIL) has emerged as a leading strategy to thoroughly assess the impact of proprietary inverter controls on a specific power system. The development of a PHIL test bed typically involves an inverter under test, a power amplifier, controllable DC supply, and a digital real-time simulator (DRTS) to simulate the power system under study. As a result of PHIL nonidealities, a form of digital compensation within the DRTS is used, which is commonly referred to as a PHIL interface. Many existing methods use legacy power amplifiers that do not contain internal voltage regulation. These existing interface methods are based around a voltage regulator within the DRTS and do not consider the interaction with the controls in newer amplifiers. In this study, a three-step approach of PHIL interface development for modern power amplifiers with built-in voltage regulation is introduced and is validated in hardware with a 30-kW grid-following inverter.

DRTS↗

Software Control Program For Transportable Microgrid State-of-charge Balancing And Frequency Stability Controls

A deterministic state-of-charge (SOC) balancing approach software control code is introduced as an integral secondary management to primary control layer of an islanded small microgrid or nanogrid system made up of multiple grid-forming inverter/battery/solar combination systems, where each set of batteries with each inverter are on independent DC buses (i.e. non-paralleled on the DC sides). A DERMS-level control approach, algorithm and automation controller program was developed to improve coordination and enable microgrid asset compliance and SOC balancing, enabling provision of a system-level power stability support architecture, load support, and asset scalability. The architecture is configured to treat each unit or micro/nano-grid as a node in a microgrid network, allowing for autonomous DERMS control regarding load and SOC balancing and power stability. As the network grows with the addition of units, greater coordination efforts may be required. The ideal small network microgrid ranges from 2-10 inverter/battery units before additional control parameters must be considered in the existing architecture. The control approach focuses on a deterministic state-of-charge analysis as the primary level control process followed by a secondary control loop using a forced frequency-watt droop strategy to conform off-the-shelf components into behaving under a leader-follower configuration. Adopting this control scheme has been shown to allow for a balanced, unit-coordinated microgrid network, enabling stable power flow. The deterministic state-of-charge approach is introduced as an integral primary control layer of an islanded small network microgrid. A standard strategy for SOC balancing is implementing a battery management system (BMS) to control SOC on the DC side. An alternative approach is to determine how to coordinate sending and receiving power on the AC side with multiple units. The latter approach assesses all the integrated units in the microgrid network. Once the individual units are identified, further system data is required to calculate each unit's total kWh, provided information about its capability to supply or consume kWh and availability. The secondary control layer in the multi-layered small network microgrid methodology uses the primary layer’s decision to initiate frequency setpoint changes, initializing the SOC balancing. The secondary control layer considers numerous system-dependent variables to enable a charging and discharging profile based on adjustable frequency setpoints. The combined architecture will result in stable, coordinated power flow enhancing an AC microgrid's functionalities.

Myers, KurtS [Idaho National Laboratory (INL), Ida↗

Dual-loop Solvent-based CCS for Net Negative CO 2 Emissions with Lower Cost

This final technical report details the successful design, construction, and operational validation of an innovative dual-loop CO 2 capture technology designed to achieve deep decarbonization (>99%) from Natural Gas Combined Cycle (NGCC) power plants that results in the electricity with carbon intensity of approximate 42 kg CO 2 -eq/MWh, less than the electricity produced by solar PV. The integrated process couples a primary aqueous solvent (in this project, a water lean solvent – WLS) absorption loop for bulk CO 2 removal with a secondary potassium hydroxide (KOH) polishing loop featuring electrochemical regeneration. This architecture leverages the higher exergy efficiency of the primary loop while utilizing the fastest kinetic of the secondary loop to capture dilute residual CO 2 , achieving an overall capture rate of 99.9% and co-producing pure hydrogen after moisture being condensed and dehydrated. Technical feasibility was established through a comprehensive 2,000-hour experimental campaign on a bench-scale fully-integrated unit (using 4” absorber and 4” stripper) with the feeding flue gas flowrate in the range of 8-20 cfm, confirming the attainment of Technology Readiness Level (TRL) 4. The project executed extensive parametric testing followed by 1,000 hours of continuous steady-state testing, demonstrating exceptional process stability with the electrochemical regenerator exhibiting less than a 10% reduction in electrical conductivity over the duration of the campaign. Operational characterization gathering on the bench unit revealed distinct energy profiles for the hybrid system: the primary loop required approximately 280 kJ mol -1 for bulk removal, while the polishing loop required approximately 1,600 kJ mol -1 specifically when reducing dilute CO 2 concentrations from ~740 ppm down to <50 ppm. (Please note those energy values/numbers can only be viewed as relative relationship and should not be extrapolated as absolute values required for CO 2 capture). Furthermore, dynamic testing validated the system’s flexibility for utility applications, demonstrating a rapid process response time of <30 minutes to changes in flue gas flowrate. Emission monitoring confirmed that the dual-loop architecture effectively mitigates solvent losses, utilizing a water wash to remove entrained aerosols to <1 ppm. The Techno-Economic Analysis (TEA) indicates a cost of capture of $\$$59.3/tonne and a Levelized Cost of Electricity (LCOE) of 71.7 $\$$/MWh at the overall capture efficiency of 99.8% of total carbon in the flue gas stream, with sensitivity analysis identifying an economic optimum when the primary loop captures 97% of the total CO 2 . A Life Cycle Assessment (LCA) confirms the technology’s potential for net-negative emissions, determining a Global Warming Potential (GWP) of 52 kg CO 2 -eq/MWh—significantly lower than the baseline—which further decreases to 42 kg CO 2 -eq/MWh when crediting the displacement of conventional hydrogen production.

03 NATURAL GAS↗

End-to-end Analytics for Grid Arch Design & All-hazard Assessment

Resiliency, reliability, and security of the next-generation smart grid depend upon leveraging advanced communication and computing technologies, integrating them with physical power systems, and developing real-time, fast, data-based applications to help in wide-area monitoring and control of the grid. Using a high sampling data rate from phasor measurement units (PMUs) to develop applications has opened the door to achieving the next-generation grid requirements. The North American Synchrophasor Initiative Network (NASPlnet) was developed in 2007-09 to create a standard and guide for PMU data exchanges. With the advancement in both networking and grid requirements, it is necessary to evaluate the performance of different NASPInet versions and their impact on applications. Therefore, we need a cyber-power cosimulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents a cyber-physical co-simulation testbed using NS3 to model the communication network, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application based on PMU data in an Institute of Electrical and Electronics Engineers 39-bus test system is presented using this co-simulation testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of an All-Aqueous Thermally Regenerative Redox Flow Battery to Support Fossil Fuel Assets

Low-temperature thermal energy, a largely untapped resource, holds significant promise for large-scale electrical power generation globally. Various stationary sources, including industrial entities and thermal power plants, emit considerable low-temperature heat that currently remains unutilized. This energy is often overlooked because its low temperature renders it unsuitable for efficient power generation using conventional methods. However, current research is exploring diverse technologies capable of converting low-temperature heat into grid-scale power, aiming to enhance grid efficiency, further decarbonization initiatives, and facilitate a shift toward more decentralized power systems. One such innovative technology is the thermally regenerative battery (TRB), noted for its high power and energy densities compared to similar technologies, positioning it as a potential game-changer in power generation. TRBs integrate two scalable and well-established unit operations: a redox flow battery and a distillation column. This integration suggests that once an effective TRB chemistry is established, the pathway to commercialization could be expedited. The copper-based thermally regenerative ammonia battery (Cu aq -TRAB) stands out as the first TRB that circumvents electrodeposition/dissolution reactions, stabilizing Cu(I) and Cu(II) within the electrolyte and maintaining stability of all electroactive species in an aqueous phase. This stabilization has led to improvements in coulombic efficiency, open circuit potential, and copper solubility, thereby enhancing power density, energy density, and overall energy efficiency. Preliminary tests were conducted to determine the effects of various electrolyte species on the performance metrics of the battery, both theoretically and experimentally. These tests revealed that the solubility of copper in the Cu aq -TRAB electrolyte was constrained by the Cu(I)-NH 3 complex. Adjusting the background electrolyte to 5 M NH4Br and the ligand concentration to 4 M NH 3 enabled the copper concentration to reach a maximum of 0.6 M. This modification led to an estimated theoretical maximum energy density of 9.5 Wh L -1 for the Cu aq -TRAB. Additionally, full cell testing indicated a tradeoff between peak power and energy density with varying copper and ammonia concentrations. Increasing the applied current density during discharge linearly raised the average power output, with a minimal reduction in energy density due to a balance between higher ohmic overpotential and reduced time for undesirable ammonia crossover. Furthermore, a comprehensive numerical sensitivity analysis of the complete Cu aq -TRAB system was performed. This analysis aimed to assess how the battery and the distillation column responded to changes in system input parameters, providing insights into optimal research directions for enhancing system performance. The analysis revealed that at room temperature, battery power was significantly more sensitive to ohmic losses than to mass transfer, with reaction rates having minimal impact. This trend continued even at higher temperatures. Also, the thermal energy required for ammonia separation was studied, showing that increased temperatures generally reduced energy requirements, except in low-pressure scenarios above 65 °C. An investigation into membrane performance in the Cu aq -TRAB was undertaken, given the significant impact of ammonia transport control and ohmic losses on system performance. Various membranes were evaluated to identify key performance metrics. Among the tested membranes, Selemion CMVN exhibited the highest performance, with a peak power density of 84 mW cm -2 and average values of 26 ± 6.8 mW cm -2 for power density and 2.9 Wh L -1 for energy density at an applied current density of 50 mA cm -2 . An economic assessment indicated a levelized cost of storage at $410 per MWh under optimal conditions, highlighting the commercial potential of the Cu aq -TRAB when utilizing cost-effective, readily available materials.

25 ENERGY STORAGE↗

Semiconductor: Supply Chain Deep Dive Assessment

In February 2021, President Biden signed Executive Order (EO) 14017, “America’s Supply Chains,” directing seven executive agencies to evaluate the resilience and security of the nation’s critical supply chains and to craft strategies for six industrial bases that underpin America’s economic and national security. See Sec. 3(b) of E.O. 14017. As part of the one-year response to EO 14017, the U.S. Department of Energy (DOE), through the national laboratories, conducted evaluations of the supply chains that encompass the Energy Sector Industrial Base, with a particular focus on technologies required to decarbonize the U.S. by 2050. This report focuses on one of these technologies, semiconductors, both conventional and wide bandgap (WBG) power electronics (PE). As noted in the 100-Day report, conventional semiconductors are a keystone technology that are essential for the operation of nearly every electronic device, including those that are critical to decarbonization, such as electric vehicles (EVs), industrial and building applications, and electricity generation and end use. In addition, power electronics have been applied to industrial equipment to improve energy efficiency and enhance controllability. Power electronics have also been used to improve the reliability of data centers and critical infrastructure, including the stabilization of the electric grid while subjected to disturbances. Increasingly, power electronics are being used to integrate renewable energy and battery storage systems, enabling new grid services and the development of microgrids. It is estimated that 30% of the electricity used in the U.S. passes through power electronic devices, and studies suggest that this number could reach 80% as power electronics are deployed in more markets. Nearly all forms of electrified transportation will depend on power electronics. Power electronic systems utilize high-capacity semiconductor devices at their core. The continued growth in power electronics depends on sustained innovation in the semiconductor industry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Designing Hydropower Flows to Balance Energy and Environmental Needs (HydroWIRES Topic A Final Project Report)

Hydropower is expected to play a new role in the US electricity grid as more variable renewable energy sources like wind and solar come online. Wind and solar generation increase fluctuations in electrical supply increasing the value of flexible generation sources that can quickly ramp generation up and down. The flexible generation hydropower can provide as well as the ancillary services (e.g., frequency and voltage regulation and reserves, black start capability) it provides for balancing and stabilizing the power grid are predicted to be of increased value in these future grid scenarios. Yet, the flexibility of hydropower may come with environmental costs due to up- and down-ramping of hydropower plants (i.e., quickly increasing or decreasing generation flows, respectively) which may strand fish, dewater or scour fish nests, alter habitat, or create unsafe recreational conditions that may be unacceptable to participants in the hydropower regulatory process. These types of environmental impacts are often mitigated through environmental flow requirements that specify minimum or maximum flow releases, or ramp-rates changes allowed at a hydropower facility. While it is not currently known to what degree electrical grid reliability could be affected by environmental flow requirements, gaining a better understanding of these interactions before the grid becomes more deeply decarbonized can help define what policy, regulation, or infrastructure may be needed to support the clean energy transition. As the future grid will rely on hydropower to provide both flexibility and robust environmental protections, the analyses and tools described in this report are centered on making mechanistic linkages between energy and the environment in hydropower systems. This understanding of energy-environment linkages can provide the foundational understanding needed to quantitatively assess the trade-offs between the increased generation flexibility that hydropower will be expected to provide and the environmental impacts of this flexibility. This report seeks to provide an objective foundation for building future science and tools that can be used by a broad spectrum of the hydropower community that is involved in licensing or environmental regulatory proceedings tasked with balancing energy and environmental objectives through flow management.

13 HYDRO ENERGY↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Avoidance of disruptions on KSTAR due to vertical displacement events via novel real-time stability assessment

Disruption avoidance via the DECAF approach has been achieved on KSTAR using a novel real-time vertical stability assessment and a multiactuator feedback control strategy. The development of disruption avoidance strategies with reactor-relevant reliability is an urgent activity, enabling future fusion power plants. The stability metric employed is based on a new formulation of a vertical force gradient balance metric evaluated across the poloidal cross section of the plasma, with parameters tuned using historical data. Evaluation of this metric on a validation set of 400 recent KSTAR shots indicates >82% of Vertical displacement events can be avoided via feedback control. Essential to its calculation is the two-dimensional toroidal current density distribution in the plasma. Measurement of this profile faster than fully-converged equilibrium reconstructions can deliver is found to improve forecaster performance and is achieved with a surrogate model that takes as input magnetic diagnostic measurements and outputs the current profile on a basis comprising the top principal components of historical current profiles (from past equilibrium reconstructions). This method solves the non-uniqueness problem typically faced when reconstructing current profiles directly from diagnostics, while improving computational time and accuracy. On average, profiles produced by this model reach coefficients of determination of >0.99 with respect to those from equilibrium reconstructions. The avoidance actuators employed include poloidal field coils and an electron cyclotron current drive system. The multiactuator approach, as shown in this first demonstration, allows disruption avoidance while minimizing impact to operational performance. This ability, along with its flexibility and speed, makes this new approach an attractive option for avoiding these types of disruptions in reactors.

Tobin, Matthew [Columbia Univ., New York, NY (Unit↗

High-Efficiency and Low-Carbon Energy Storage and Power Generation System for Electric Aviation

This report summarizes the work performed by University of California San Diego (UCSD) – Honeywell Aerospace (Honeywell) team for the U.S. Department of Energy/Advanced Research Projects Agency-Energy (DOE/ARPA-E) under Phase 1 (April 2021 – October 2023) project, Cooperative Agreement DE-AR0001347 entitled “High-Efficiency and Low-Carbon Energy Storage and Power Generation System for Electric Aviation”. The main objective of this project is to develop and demonstrate an energy storage and power generation (ESPG) system operating on bio liquid natural gas (LNG) for electric aviation applications. The ESPG system concept in this project is a fuel cell, battery, and gas turbine hybrid system that incorporates an innovative solid oxide fuel cell (SOFC) technology. This SOFC technology has two main novel elements: (i) a lightweight and compact stack architecture that consists of cells and cell modules in electrical parallel and series connections (the module design) and (ii) exceptionally high performance, direct methane thin-film cells on porous substrate made by sputtering deposition process. This fuel cell has the specific power and volumetric power density suitable for electric aviation applications. Based on the current status of the SOFC technology, the Phase 1 work focused on the following activities: (i) ESPG System Modeling – to design and optimize an aircraft SOFC-based ESPG system concept that met the performance, weight and cost targets; (ii) Cell Material Development and Scaleup – to demonstrate scalability of the sputtering process for manufacture of thin-film SOFC cells of practical sizes, confirm the exceptional performance of sputtered cells, improve cell stability and durability for operation with hydrogen and methane fuel, and develop a suitable electrically conducting porous substrate to replace the current non-conducting ceramic substrate; (iii) Stack Development – to design and manufacture stack components for the stack architecture, evaluate and select a suitable sealant, and build and operate multi-cell stacks to demonstrate stack operation, and (iv) Technology to Market – to develop business models and commercialization plans, conduct various market and technology analysis and estimate SOFC and ESPG system costs.

25 ENERGY STORAGE↗

T&D LIBRA: Simulation Framework for Transmission and Distribution Load and IBR Assessment

This paper introduces T&D LIBRA, a HELICS-based dynamic co-simulation framework designed for transmission and distribution (T&D) load and inverter-based resource assessment. This framework is designed to model interactions between single-phase induction motors (i.e., Motor-D), distributed energy resources (DERs) and the transmission network, emphasizing system stability during fault conditions. The primary objective of this research is to study the fault-induced delayed voltage recovery (FIDVR) behavior of the T&D networks using the co-simulation framework and to compare the results with conventional PSS/E only simulations. Simulations are validated using T&D co-simulations with a single distribution node and the IEEE 123-bus distribution test case. The co-simulation results demonstrate the value of using T&D co-simulations to capture motor stalling, DER tripping and other sources of voltage diversity on distribution networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement and modeling of proton-induced reactions on arsenic from 35 to 200 MeV

72 As is a promising positron emitter for diagnostic imaging that can be employed locally using a 72 Se generator. However, current reaction pathways to 72 Se have insufficient nuclear data for efficient production using regional 100–200 MeV high-intensity proton accelerators. In order to address this deficiency, stacked-target irradiations were performed at LBNL, LANL, and BNL to measure the production of the 72 Se/ 72 As positron emission tomography (PET) generator system via 75 As (p, x) between 35 and 200 MeV. This work provides the most well-characterized excitation function for 75 As ( p , 4 n ) 72 Se starting from threshold. Additional focus was given to report the first measurements of 75 As (p, x) 68 Ge and bolster an already robust production capability for the highly valuable 68 Ge/ 68 Ga PET generator. Thick target yield comparisons with prior established formation routes to both generators are made. In total, high-energy proton-induced cross sections are reported for 55 measured residual products from 75 As, nat Cu , and nat Ti targets, where the latter two materials were present as monitor foils. These results were compared with literature data as well as the default theoretical calculations of the nuclear model codes TALYS, COH, EMPIRE, and ALICE. Reaction modeling at these energies is typically unsatisfactory due to few prior published data and many interacting physics models. Therefore, a detailed assessment of the talys code was performed with simultaneous parameter adjustments applied according to a standardized procedure. Particular attention was paid to the formulation of the two-component exciton model in the transition between the compound and preequilibrium regions, with a linked investigation of level density models for nuclei off of stability and their impact on modeling predictive power. This paper merges experimental work and evaluation techniques for high-energy charged-particle isotope production in an extension to an earlier study of this kind.

43 PARTICLE ACCELERATORS↗