Search NASA⌕ Search

SEARCH · Search NASA

Results for “preamplifiers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Voyager telecommunications - The broadcast from Jupiter

The means by which the data collected by the Voyager 1 mission to Jupiter were returned to earth are presented. Radio links between the earth and the spacecraft are used for the transmission of both imaging and nonimaging telemetry from the spacecraft and commands from the earth and for radiometric observations of the spacecraft and its environment. Features which have lead to vast improvements in the capability of the Voyager telecommunications system over that of previous space probes include the use of X-band rather than S-band telemetry, a dual power X-band traveling wave tube amplifier, a 3.7 m spacecraft antenna and a single channel telemetry system with concatenated coding. Communications equipment at the three ground complexes of the Deep Space Network for telemetry reception includes 64 m steerable antennas, cryogenic maser preamplifiers and a phase-lock loop receiver. Voyager 1 has met or exceeded all of its telecommunications requirements, providing a 98% data return and a total of 2 x 10 to the 11th data bits during the Jupiter encounter.

Edelson, R. E.↗

Microprocessor-based cardiotachometer

Instrument operates reliably even with stress-test electrocardiogram (ECG) signals subject to noise, baseline wandering, and amplitude change. It records heart rate from preamplified, single-lead ECG input signal and produces digital and analog heart-rate outputs which are fed elsewhere. Analog hardware processes ECG input signal, producing 10-ms pulse for each heartbeat. Microprocessor analyzes resulting pulse train, identifying irregular heartbeats and maintaining stable output during lead switching. Easily modified computer program provides analysis.

Crosier, W. G.↗

Cloud Top Scanning radiometer (CTS)

A scanning radiometer to be used for measuring cloud radiances in each of three spectral regions is described. Significant features incorporated in the Cloud Top Scanner design are: (1) flexibility and growth potential through use of easily replaceable modular detectors and filters; (2) full aperture, multilevel inflight calibration; (3) inherent channel registration through employment of a single shared field stop; and (4) radiometric sensitivity margin in a compact optical design through use of Honeywell developed (Hg,Cd)Te detectors and preamplifiers.

Source record↗

Sub mm laser local oscillators: Design criteria and results

Diagnostic results are given of the spectral features and the power conversion efficiency of submillimeter (SMM) laser local oscillators. Several criteria are obtained for the design of frequency stable and efficient smm lasers for local oscillator applications. Finally, a design is described and results on the power output and power and frequency stability are given. The mode pattern is very close to a Gaussian profile so that efficient coupling to a quasioptical mixer is possible. The laser provides sufficient output power at a large number of lines to drive the mixer into the low conversion loss regime. Radiometric integration times of several minutes with a spectral resolution of 1 MHz will be possible. With present state-of-the-art Schottky mixers and low noise preamplifiers a radiometric temperature resolution of a few K can be expected over a spectral range from 500to 900 GHz.

Koepf, G. A.↗

A 4-W 56-dB gain microstrip amplifier at 15 GHz utilizing GaAs FET's and IMPATT diodes

Performance results and design considerations are presented for an all solid-state Ku-band power amplifier which is feasible for use in PM communication systems for airborne or spacecraft transmitter applications. A six-stage GaAs FET preamplifier and a driver and balanced power amplifier utilizing GaAs IMPATT diodes operating in the injection locked oscillator mode are discussed. For high power and efficiency Schottky-Read IMPATT's with low-high-low doping profiles are employed. For improved reliability the IMPATT's incorporate a TiW barrier metallization to retard degradation of the IMPATT's. Results of accelerated life testing of the IMPATT devices are also presented.

Sokolov, V.↗

Measurement of minority-carrier drift mobility in solar cells using a modulated electron beam

A determination of diffusivity on solar cells is here reported which utilizes a one dimensional treatment of diffusion under sinusoidal excitation. An intensity-modulated beam of a scanning electron microscope was used as a source of excitation. The beam was injected into the rear of the cell, and the modulated component of the induced terminal current was recovered phase sensitively. A Faraday cup to measure the modulated component of beam current was mounted next to the sample, and connected to the same electronics. A step up transformer and preamplifier were mounted on the sample holder. Beam currents on the order of 400-pA were used in order to minimize effects of high injection. The beam voltage was 34-kV, and the cell bias was kept at 0-V.

Othmer, S.↗

Performance of room temperature mercuric iodide /HgI2/ detectors in the ultralow-energy X-ray region

Experiments have been done to study the performance of mercuric iodide (HgI2) detectors in the ultralow-energy X-ray region. Energy resolution values of 245 eV (FWHM) for the Mg K-alpha X-ray line at 1.25 keV and 225 eV (FWHM) for the electronic noise linewidth have been obtained for an HgI2 detector with painted carbon contacts using a pulsed-light feedback preamplifier; the whole system was operated at room temperature. The resolution values in the ultralow-energy region are still limited by electronic noise of the system. In an attempt to minimize X-ray attenuation in the front contact, detectors were prepared with thin evaporated Pd contacts. These detectors show a pronounced low-energy tailing of the photopeak below a few keV, in contrast to the spectra obtained by detectors with carbon contact. An attempt has been made to explain the tailing effect starting with models wich have been proposed to describe similar effects in Ge detectors.

Dabrowski, A. J.↗

Simple cryogenic temperature regulator - The Zener diode

For obtaining optimum performance from cooled infrared detectors used in astronomy, it is often necessary to operate the preamplifier transistor (usually a JFET) at a higher temperature than that provided by the cryogen. Various means of elevating the temperature of the FET above the temperature of its environment are considered. A description is presented of a method which uses a 10 V Zener diode (actually an avalanche diode) as a self-stabilizing heater element. The diode is mounted in good thermal contact with the FET, and both are isolated from the work surface by a link of poor conductivity. The diode is driven by a stable, constant voltage power supply.

Storey, J. W. V.↗

Focal-plane optimization for detector noise limited performance in cryogenic Fourier transform spectrometer /FTS/ sensors

A study was performed to determine the optimum focal plane configuration including optics, filters and detector-preamplifier selection. The configuration was optimized particularly with respect to minimizing the noise level, but fabrication considerations for a cryogenic environment were also taken into account. The noise terms from source, background, detector electronics and charged particle radiation were quantitatively evaluated. It appears that noise equivalent spectral radiance less than 10 to the -11th W/sq cm per sr per kayser can be achieved between 2.5 and 20 microns.

Mcguirk, M.↗

Design, production, and testing of field effect transistors

Cryogenic MOSFETS (CRYOFETS), specifically designed for low temperature preamplifier application with infrared extrinsic detectors were produced and comparatively tested with p-channel MOSFETs under matched conditions. The CRYOFETs exhibit lower voltage thresholds, high source-follower gains at lower bias voltage, and lower dc offset source voltage. The noise of the CRYOFET is found to be 2 to 4 times greater than the MOSFET with a correspondingly lower figure of merit (which is established for source-follower amplifiers). The device power dissipation at a gain of 0.98 is some two orders of magnitude lower than for the MOSFET. Further, CRYOFETs are free of low temperature I vs V character hysteresis and balky conduction turn-on effects and operate effectively in the 2.4 to 20 K range. These devices have promise for use on long term duration sensor missions and for on-focal-plane signal processing at low temperatures.

Sclar, N.↗

Integrating 128-element linear imager for the 1 to 5 microns region

Useful charge integration has been achieved in high quality photovoltaic InSb diodes when combined with a FET multiplexing (MUX) scheme. An experimental detector assembly with a linear array of 128 InSb diodes coupled to a FEX MUX has been developed. The first stage J-FET preamp, pixel reset switch, MUX, and the InSb array are contained in a hybrid microcircuit of compact dimensions. A low noise preamplifier topology which capitalizes on the low video line capacitance inherent with hybrid fabrication techniques is also utilized. Measurements indicate a signal-to-noise ratio of over 1000:1 and response uniformity of + or - 2 percent. Sample images show subtle detail which supports the estimated radiometric sensitivity of 0.01 K.

Bailey, G. C.↗

History, status and future applications of spaceborne cryogenic systems

Cryogenic cooling is employed for an increasing number of space instruments. Cryogenic cooling is needed to provide the required detector response, reduce preamplifier noise, and/or reduce background radiation. Cryogenic cooling is required by instruments employed for applications missions, gamma-ray and X-ray astronomy, cosmic ray measurements, space surveillance, IR astronomy, relativity measurements, superconductivity devices, and basic research experiments. The cooling is provided with the aid of radiant coolers, stored solid cryogen coolers, stored liquid-helium coolers, mechanical coolers, He-3 coolers, adiabatic demagnetization, refrigeration, and higher temperature adsorption and magnetic systems. Radiant coolers will continue to find widespread application for low cooling-load/high-temperature situation. It is pointed out that a long-lifetime closed-cycle, mechanical cooler is one of the most critical space technological needs.

Sherman, A.↗

The ISPM unified radio and plasma wave experiment

Hardware for the International Solar Polar Mission (ISPM) Unified Radio and Plasma (URAP) wave experiment is presented. The URAP determines direction and polarization of distant radio sources for remote sensing of the heliosphere, and studies local wave phenomena which determine the transport coefficients of the ambient plasma. Electric and magnetic field antennas and preamplifiers; the electromagnetic compatibility plan and grounding; radio astronomy and plasma frequency receivers; a fast Fourier transformation data processing unit waveform analyzer; dc voltage measurements; a fast envelope sampler for the solar wind, and plasmas near Jupiter; a sounder; and a power converter are described.

Stone, R. G.↗

MLS/Airplane system design. RF component design

Results of analysis and design conducted as part of multiyear Microwave Landing System (MLS) study are reported. Design of airborne radio frequency RF MLS components was performed. MLS omnidirectional antennas are developed using microstrip technology. A remote, low-noise, radio frequency (RF) preamplifier is designed for airborne MLS installations.

Walen, D. B.↗

Advanced components for spaceborne infrared astronomy

The need for improved cryogenic components to be used in future spaceborne infrared astronomy missions was identified. Improved low noise cryogenic amplifiers operated with infrared detectors, and better cryogenic actuators and motors with extremely low power dissipation are needed. The feasibility of achieving technological breakthroughs in both of these areas was studied. An improved silicon junction field effect transistor (JFET) could be developed if: (1) high purity silicon; (2) optimum dopants; and (3) very high doping levels are used. The feasibility of a simple stepper motor equipped with superconducting coils is demonstrated by construction of such a device based on a standard commercial motor. It is found that useful levels of torque at immeasurably low power levels were achieved. It is concluded that with modest development and optimization efforts, significant performance gains is possible for both cryogenic preamplifiers and superconducting motors and actuators.

Davidson, A. W.↗

A transceiver module of the Mu radar

The transceiver (TR) module of a middle and upper atmospheric radar is described. The TR module used in the radar is mainly composed of two units: a mixer (MIX unit) and a power amplifier (PA unit). The former generates the RF wave for transmission and converts the received echo to the IF signal. A 41.5-MHz local signal fed to mixers passes through a digitally controlled 8-bit phase shifter which can change its value up to 1,000 times in a second, so that the MU radar has the ability to steer its antenna direction quickly and flexibly. The MIX unit also contains a buffer amplifier and a gate for the transmitting signal and preamplifier for the received one whose noise figure is less than 5 dB. The PA unit amplifies the RF signal supplied from the MIX unit up to 63.7 dBm (2350 W), and feeds it to the crossed Yagi antenna.

Kato, S.↗

Long wavelength photoconductive detectors for airborne and orbital infrared astronomy

Seven gallium doped germanium (Ge:Ga) photoconductive infrared detectors were fabricated and mounted in integrating cavities. In addition, a cold preamplifier package consisting of J230 junction field effect transistors (JFETs) was produced. Tests of the system under low photon background conditions indicated that sensitivity was limited by the Johnson noise of the load resistor. The detectors were mounted in the Ames cooled grating spectrometer, and flown on the Kuiper Airborne Observatory. Good quality astronomical data were obtained during the flight of 7 July 1983.

Houck, J. R.↗