Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Development of a High-Pressure Gaseous Burner for Calibrating Optical Diagnostic Techniques

In this work-in-progress report, we show the development of a unique high-pressure burner facility (up to 60 atm) that provides steady, reproducible premixed flames with high precision, while having the capability to use multiple fuel/oxidizer combinations. The highpressure facility has four optical access ports for applying different laser diagnostic techniques and will provide a standard reference flame for the development of a spectroscopic database in high-pressure/temperature conditions. Spontaneous Raman scattering (SRS) was the first diagnostic applied, and was used to successfully probe premixed hydrogen-air flames generated in the facility using a novel multi-jet micro-premixed array burner element. The SRS spectral data include contributions from H2, N2, O2, and H2O and were collected over a wide range of equivalence ratios ranging from 0.16 to 4.9 at an initial pressure of 10-atm via a spatially resolved point SRS measurement with a high-performance optical system. Temperatures in fuel-lean to stoichiometric conditions were determined from the ratio of the Stokes to anti-Stokes scattering of the Q-branch of N2, and those in fuel-rich conditions via the rotational temperature of H2. The SRS derived temperatures using both techniques were consistent and indicated that the flame temperature was approximately 500 K below that predicted by adiabatic equilibrium, indicating a large amount of heat-loss at the measurement zone. The integrated vibrational SRS signals show that SRS provides quantitative number density data in high-pressure H2-air flames.

Kojima, Jun↗

Unsteady Pressure Sensitive Paint Camera Calibration Improvements

New challenges have arisen in processing a significantly increased volume of data collected during recent large-scale demonstrations of unsteady pressure-sensitive paint. Techniques designed for several thousands of images collected in a lab do not necessarily scale to tens of millions collected in a large-scale test. New techniques are needed to meet the tighter requirements on robustness and accuracy that accompany larger wind tunnel models, higher camera resolution, and more run conditions per test. This paper outlines several such techniques and improvements in regard to the camera calibration process.

Camera calibration↗

Unsteady Pressure Sensitive Paint Camera Calibration Improvements

New challenges have arisen in processing a significantly increased volume of data collected during recent large-scale demonstrations of unsteady pressure-sensitive paint. Techniques designed for several thousands of images collected in a lab do not necessarily scale to tens of millions collected in a large-scale test. New techniques are needed to meet the tighter requirements on robustness and accuracy that accompany larger wind tunnel models, higher camera resolution, and more run conditions per test. This paper outlines several such techniques and improvements in regard to the camera calibration process.

Camera calibration↗

A miniature 48-channel pressure sensor module capable of in situ calibration

A new high data rate pressure sensor module with in situ calibration capability has been developed by the Langley Research Center to help reduce energy consumption in wind-tunnel facilities without loss of measurement accuracy. The sensor module allows for nearly a two order of magnitude increase in data rates over conventional electromechanically scanned pressure sampling techniques. This module consists of 16 solid state pressure sensor chips and signal multiplexing electronics integrally mounted to a four position pressure selector switch. One of the four positions of the pressure selector switch allows the in situ calibration of the 16 pressure sensors; the three other positions allow 48 channels (three sets of 16) pressure inputs to be measured by sensors. The small size of the sensor module will allow mounting within many wind-tunnel models, thus eliminating long tube lengths and their corresponding slow pressure response.

Gross, C.↗

Creating Calibration Curves to Determine Shock Pressure in Clinopyroxene

Impact cratering is an important geological process that occurs on every rocky body in the solar system. It alters the texture and mineralogy of rocks via shock metamorphism. The peak shock pressures experienced by a rock are traditionally evaluated using qualitative optical methods however, quantitative methods do exist. One such method was developed by Uchizono et al., who used X-ray Diffraction (XRD) to measure lattice strain (ε) in several artificially shocked olivine grains using XRD peak broadening as a function of tan θ, where θ is the diffraction angle. They plotted the ε values against the known peak shock pressures experienced by the olivine grains. Using this calibration curve, the precise shock pressure experienced by a grain of olivine can be determined using its measured ε value. Another method was developed by McCausland et al. and Izawa et al., who used in situ XRD to measure strain-related mosaicity (SRM) of olivine in several ordinary chondrites and enstatite in enstatite chondrites, respectively. They plotted these results against the shock stage estimates for these meteorites. Using these plots, meteorites can be assigned to shock stage bins by measuring the SRM of olivine and/or enstatite. Both methods are useful for evaluating shock metamorphism, however, they have limitations. Uchizono et al.’s calibration curve has been successfully applied to martian meteorites, however it can only be applied to olivine-bearing rocks. McCausland et al.’s and Izawa et al.’s SRM method is uncalibrated and is limited to binning meteorites by shock stage. This work aims to expand on both methods by creating calibration curves for clinopyroxene (CPX): one for ε, similar to Uchizono et al.’s calibration curve for olivine, and one for SRM. This will extend the application of shock calibration methods to a greater variety of rock types. Preliminary results are presented herein.

Jenkins, Laura E.↗

Calibration of seven-hole pressure probes for use in fluid flows with large angularity

Described here is the calibration of a non-nulling, conical, seven-hole pressure probe over a large range of flow onset angles. The calibration procedure is based on the use of differential pressures to determine the three components of velocity. The method allows determination of the flow angle to within 0.5 deg and velocity magnitude to approximately 1.0 percent. Also included is an examination of the factors which limit the use of the probe, a description of the measurement chain, an error analysis, and a typical experimental result. In addition, a new general analytical model of pressure probe behavior is described and the validity of the model is demonstrated by comparing it with experimentally measured calibration data for a three-hole yaw meter and a seven-hole probe.

Zilliac, Gregory G.↗

Piston manometer as an absolute standard for vacuum-gauge calibration.

Determination of the total pressure in a calibration volume by measuring the force on a thin circular disk, of accurately known area, that is freely suspended in a hole in the container wall, so that the disk is substantially flush with the wall. The disk almost fills the hole, so that there is a narrow annular gap. A continuous flow of calibrating gas, injected into the container in order to maintain a desired pressure, passes through the annular gap to a diffusion pump. The ratio of pressures on the two faces of the disk is of the order of 100:1, so that downstream pressure need be known only nominally in order to deduce the upstream surface. Force on the disk is measured by a balance that is calibrated in situ with dead weights. In one arrangement, pressures in the range from 10 to 500 microtorr were measured with an estimated probable error of (1 microtorr + 1%).

Warshawsky, I.↗

Establishing gold and platinum standards to 1 terapascal using shockless compression

New techniques are advancing the frontier of high-pressure physics beyond 1 terapascal, leading to new discoveries and offering stringent tests for condensed-matter theory and advanced numerical methods. However, the ability to absolutely determine the pressure state remains challenging, and well-calibrated pressure-density reference materials are required. We conducted shockless dynamic compression experiments at the National Ignition Facility and the Z machine to obtain quasi-absolute, high-precision, pressure-density equation-of-state data for gold and platinum. We derived two experimentally constrained pressure standards to terapascal conditions. Establishing accurate experimental determinations of extreme pressure will facilitate better connections between experiments and theory, paving the way toward improving our understanding of material response to these extreme conditions.

36 MATERIALS SCIENCE↗

Testing methods and techniques: Environmental testing: A compilation

Various devices and techniques are described for testing hardware and components in four special environments: low temperature, high temperature, high pressure, and vibration. Items ranging from an automatic calibrator for pressure transducers to a fixture for testing the susceptibility of materials to ignition by electric spark are included.

Source record↗

Calibrating Droplet Generator for Pressurized Testing Vessel

Device helps to aline laser for droplet-sizing interferometer. Monodispersing Droplet Generator creates uniformly sized droplets. Laser source and receiver of interferometer alined and focused on droplets. MDG mounted in high-pressure flange on tank. Line extensions pass through flange to outside. Flange allows MDG to operate at high injector back pressures used for tests.

Defever, G. J.↗

The Ames 12-Foot Pressure Tunnel: Tunnel Empty Flow Calibration Results and Discussion

An empty test section flow calibration of the refurbished NASA Ames 12-Foot Pressure Tunnel was recently completed. Distributions of total pressure, dynamic pressure, Mach number, flow angularity temperature, and turbulence are presented along with results obtained prior to facility demolition. Axial static pressure distributions along tunnel centerline are also compared. Test section model support geometric configurations will be presented along with a discussion of the issues involved with different model mounting schemes.

Peter T Zell↗