Search NASA⌕ Search

SEARCH · Search NASA

Results for “progress monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Automated assessment of noninvasive filling pressure using color Doppler M-mode echocardiography

Assessment of left ventricular filling pressure usually requires invasive hemodynamic monitoring to follow the progression of disease or the response to therapy. Previous investigations have shown accurate estimation of wedge pressure using noninvasive Doppler information obtained from the ratio of the wave propagation slope from color M-mode (CMM) images and the peak early diastolic filling velocity from transmitral Doppler images. This study reports an automated algorithm that derives an estimate of wedge pressure based on the spatiotemporal velocity distribution available from digital CMM Doppler images of LV filling.

Non-NASA Center↗

High-Cycle Fatigue Behavior of SiC-based Ceramic Matrix Composites (CMCs) at High Temperatures

High-cycle fatigue (HCF) behavior of a melt-infiltrated, pre-preg SiC/SiC ceramic matrix composite (CMC) was investigated using dogbone tensile specimens without and with simulated cooling holes at 1500 and 2400 °F. The CMC material used for this study was fabricated by GE Aviation and had a ply configuration of [0/90/0]3. HCF tests were conducted with an R-ratio of 0.6 and a cyclic frequency of 30 Hz. Runout in HCF was defined as 30 million cycles. Monotonic tensile tests were conducted at room temperature (RT) on as-received CMC specimens and on runout HCF specimens to determine residual tensile strengths. Digital image correlation (DIC) and acoustic emission (AE) techniques were used to monitor the initiation and progression of damage in RT tensile tests on specimens with and without holes. Microscopy was performed on the polished edge of specimens without cooling holes and on the polished face of specimens with cooling holes that were tested in HCF and achieved runout. Comparisons were made with baseline specimens. Fractography was performed to examine the fracture surfaces of samples that failed under different loading conditions.

Ceramic Matrix Composites↗

Method Development for Experimental Characterization of Dynamic Strength of Aluminum Structures

Space Flight Hardware (SFH) experiences intense vibratory loading during flight, which only lasts a few minutes. When determining the appropriate size of these components to withstand such loading without becoming damaged, standard design practice is to assume that the peak dynamic loads are applied statically. In doing so, the resulting stress is compared against a material strength parameter obtained from a quasi-static experiment. Since the near-peak stresses are only experienced over a small fraction of time in reality, this approach leads to design conservatism that unnecessarily increases structural mass as well as the associated inefficiency and financial cost. In an effort to modernize engineering design standards to appropriately consider the higher practical strength of dynamically loaded structures, this overarching research project seeks to develop an experimental test procedure for quantifying the dynamic strength of metallic alloys as a function of excitation frequency. In the ideal case, the characterization test would include an in-situ method for monitoring the onset and progression of plastic deformation of the test specimen undergoing vibratory loading. These new tests are designed to be high intensity (forcing amplitude), short term (60 seconds at full amplitude), and cyclic in nature (sinusoidal excitation via attached stinger to an otherwise cantilevered beam). In addition, the initial alloy under investigation is 6061 aluminum, due to its wide use and applicability for SFH. Thus far, the primary candidate under development with live-capacity is to track hysteresis behavior of the beam from power dissipation trends, calculated via force (from transducer on excitation stinger) and velocity (measurements from Laser Doppler Vibrometer) data and work to distinguish between elastic and plastic features. As a key component of this ongoing method development, any pseudo-live indication of plasticity could be corroborated against the outcome of a pre-post assessment of damage via macroscopic evaluation of beam geometry (i.e. assessing any permanent change in the beam’s tip deflection). Support for experimental design decisions as well as dynamic strength data from tests with excitation frequencies of 10, 40, and 55 Hz will be discussed. This work contributes to the foundation for a new type of vibration-based characterization experiments and generates initial data on the functional strength of 6061 aluminum under the conditions considered.

vibrations, plastic deformation, aluminum, testing↗

Monitoring the Hazards of Silicic Volcanoes with Remote Sensing

This report details the final progress on the Solid Earth and Natural Hazards project: Monitoring of Hazards of Silicic Volcanoes with Remote Sensing (SENH99-0000-0159). The original award went to Arizona State University (ASU) with Dr. Jonathan Fink as the P.I. and Dr. Michael Ramsey as the Co-I. In May 2000, Dr. Ramsey left ASU to take a tenure-track faculty position at the University of Pittsburgh. The principle investigators and NASA Headquarters agreed to split the grant award at the HQ level and therefore avoid the double overhead charges that would arise from a university subcontract. The objectives of the science were divided, and coordinated yearly progress reports have been submitted from each University. This report details the final progress on work carried out at Arizona State. A report by Dr. Ramsey at the University of Pittsburgh has already been submitted. The work from both institutions is closely related and this report will reflect that connection.

Fink, Jonathan↗

Modeling of stress/strain behavior of fiber-reinforced ceramic matrix composites including stress redistribution

A computational simulation procedure is presented for nonlinear analyses which incorporates microstress redistribution due to progressive fracture in ceramic matrix composites. This procedure facilitates an accurate simulation of the stress-strain behavior of ceramic matrix composites up to failure. The nonlinearity in the material behavior is accounted for at the constituent (fiber/matrix/interphase) level. This computational procedure is a part of recent upgrades to CEMCAN (Ceramic Matrix Composite Analyzer) computer code. The fiber substructuring technique in CEMCAN is used to monitor the damage initiation and progression as the load increases. The room-temperature tensile stress-strain curves for SiC fiber reinforced reaction-bonded silicon nitride (RBSN) matrix unidirectional and angle-ply laminates are simulated and compared with experimentally observed stress-strain behavior. Comparison between the predicted stress/strain behavior and experimental stress/strain curves is good. Collectively the results demonstrate that CEMCAN computer code provides the user with an effective computational tool to simulate the behavior of ceramic matrix composites.

Mital, Subodh K.↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J. Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart Pensinger↗

Detecting Thermal Barrier Coating Delamination Using Visible and Near-Infrared Luminescence from Erbium-Doped Sublayers

Nondestructive diagnostic tools are needed to monitor early stages of delamination progression in thermal barrier coatings (TBCs) because the risk of delamination induced coating failure will compromise engine performance and safety. Previous work has demonstrated that for TBCs composed of yttria-stabilized zirconia (YSZ), luminescence from a buried europium-doped sublayer can be utilized to identify the location of TBC delamination from the substantially higher luminescence intensity observed from the delaminated regions of the TBC. Luminescence measurements from buried europium-doped layers depend on sufficient transmittance of the 532 nm excitation and 606 nm emission wavelengths through the attenuating undoped YSZ overlayer to produce easily detected luminescence. In the present work, improved delamination indication is demonstrated using erbium-doped YSZ sublayers. For visible-wavelength luminescence, the erbium-doped sublayer offers the advantage of a very strong excitation peak at 517 nm that can be conveniently excited a 514 nm Ar ion laser. More importantly, the erbium-doped sublayer also produces near-infrared luminescence at 1550 nm that is effectively excited by a 980 nm laser diode. Both the 980 nm excitation and the 1550 nm emission are transmitted through the TBC with much less attenuation than visible wavelengths and therefore show great promise for delamination monitoring through thicker or more highly scattering TBCs. The application of this approach for both electron beam physical vapor deposited (EB-PVD) and plasma-sprayed TBCs is discussed.

Eldridge, J. I.↗

Development of the Miniature Total Organic Carbon Analyzer

Monitoring the Total Organic Carbon (TOC) in spacecraft potable water will be of major importance in long-duration human space exploration. In-flight analysis of potable water produced from a regenerative water processor provides immediate feedback on the quality of reclaimed water for crew health as well as water processing system health monitoring. This paper updates the progress in development of the next generation Total Organic Carbon Analyzer (TOCA) designed for the unique requirements of an exploration-class mission. The current objective is to design, build, certify, deliver, and operate a TOCA technology demonstration on the International Space Station (ISS). The next generation analyzer system technology was previously developed and selected among a feasibility study of other options. The new system provides primary advantages of reduced mass and volume through reduced system complexity and reduced need for consumables; therefore, the flight project is named MiniTOCA. The project has recently completed design of the tech demo instrument and assembled and tested a flight-like engineering development unit. The engineering unit has undergone performance testing and environmental testing which provides confidence for the project to move forward with flight unit production and certification activities. Test results are summarized in this paper. The flight unit is targeted for delivery to ISS in late 2025.

TOC↗

Development of the Miniature Total Organic Carbon Analyzer

Monitoring the Total Organic Carbon (TOC) in spacecraft potable water will be of major importance in long-duration human space exploration. In-flight analysis of potable water produced from a regenerative water processor provides immediate feedback on the quality of reclaimed water for crew health as well as water processing system health monitoring. This paper updates the progress in development of the next generation Total Organic Carbon Analyzer (TOCA) designed for the unique requirements of an exploration-class mission. The current objective is to design, build, certify, deliver, and operate a TOCA technology demonstration on the International Space Station (ISS). The next generation analyzer system technology was previously developed and selected among a feasibility study of other options. The new system provides primary advantages of reduced mass and volume through reduced system complexity and reduced need for consumables; therefore, the flight project is named MiniTOCA. The project has recently completed design of the tech demo instrument and assembled and tested a flight-like engineering development unit. The engineering unit has undergone performance testing and environmental testing which provides confidence for the project to move forward with flight unit production and certification activities. Test results are summarized in this paper. The flight unit is targeted for delivery to ISS in late 2025.

TOC↗

Lamb Wave Response of Fatigued Composite Samples

Composite materials are being more widely used today by aerospace, automotive, sports equipment, and a number of other commercial industries because of their advantages over conventional metals. Composites have a high strength-to-weight ratio and can be constructed to meet specific design needs. Composite structures are already in use in secondary parts of the Douglas MD-11 and are planned to be used in the new MD-12X. Plans also exist for their use in primary and secondary structures on the Boeing 777. Douglas proposed MD-XX may also incorporate composite materials into primary structures such as the wings and tail. Use of composites in these structures offers weight savings, corrosion resistance, and improved aerodynamics. Additionally, composites have been used to repair cracks in many B-1Bs where traditional repair techniques were not very effective. Plans have also been made to reinforce all of the remaining B-1s with composite materials. Verification of the structural integrity of composite components is needed to insure safe operation of these aerospace vehicles. One aspect of the use of these composites is their response to fatigue. To track this progression of fatigue in aerospace structures, a convenient method to nondestructively monitor this damage needs to be developed. Traditional NDE techniques used on metals are not easily adaptable to composites due to the inhomogeneous and anisotropic nature of these materials. Finding an effective means of nondestructively monitoring fatigue damage is extremely important to the safety and reliability of such structures. Lamb waves offer one method of evaluating these composite materials. As a material is fatigued, the modulus degrades. Since the Lamb wave velocity can be related to the modulus of the material, an effective tool can be developed to monitor fatigue damage in composites by measuring the velocity of these waves. In this work, preliminary studies have been conducted which monitor fatigue damage in composite samples using strain gage measurements as well as Lamb wave velocity measurements. A description of the test samples is followed by the results of two different measurements of Lamb wave velocity. The first technique is a contact measurement done at a single frequency, while the second involves an immersion study of Lamb waves in which dispersion curves are obtained. The results of the Lamb wave monitoring of fatigue damage is compared to the damage progression measured by strain gages. The final section discusses the results and conclusions.

Seale, Michael↗

The Mesa Arizona Pupil Tracking System

A computer-based Pupil Tracking/Teacher Monitoring System was designed for Mesa Public Schools, Mesa, Arizona. The established objectives of the system were to: (1) facilitate the economical collection and storage of student performance data necessary to objectively evaluate the relative effectiveness of teachers, instructional methods, materials, and applied concepts; and (2) identify, on a daily basis, those students requiring special attention in specific subject areas. The system encompasses computer hardware/software and integrated curricula progression/administration devices. It provides daily evaluation and monitoring of performance as students progress at class or individualized rates. In the process, it notifies the student and collects information necessary to validate or invalidate subject presentation devices, methods, materials, and measurement devices in terms of direct benefit to the students. The system utilizes a small-scale computer (e.g., IBM 1130) to assure low-cost replicability, and may be used for many subjects of instruction.

Wright, D. L.↗

Flight 1 technical report for experiment 74-37 contained polycrystalline solidification in low-G

A .005 M solution of fluorescein in cyclohexanol was directionally solidified in a standard 10 x 10 x 45mm UV silica cuvette, using a bottom thermoelectric chilling device. Progress of the experiment was monitored by time lapse photography. During flight (SPAR I) the camera malfunctioned and only one quarter of the expected data were collected. Comparison of flight and ground specimens indicated that: (1) The dark green layer observed ahead of the solid-liquid interface which is most likely the solute-enriched zone, appears to be wider in the flight specimen; (2) Parasitic nucleation ahead of the solid-liquid interface in the flight sample led to an irregularly shaped interface, smaller grain size, equiaxed grain morphology and a larger average macroscopic growth rate; (3) The formation of equiaxed grains ahead of the solid-liquid interface in the flight specimen may be attributed to ordered islands within the liquid, which survived remelting because of the low degree of superheating (approximately equal to 1.5 C), did not settle because of reduced gravity and acted as nuclei during cooling.

Papaziak, J. M.↗

Flight 1 technical report for experiment 74-36: Thermal migration of bubbles and their interaction with solidification interfaces

Specimens of gas saturated carbon tetrabromide were directionally solidified in a transparent furnace using a gradient freeze technique. The original temperature gradient was 5 C/cm and the cooling rate was 40 C/h. Progress of the experiment was monitored photographically. Gas bubbles were generated at the advancing solidification front in each of the three specimens. The gas bubbles were observed to increase in size, coalesce, and eventually be grown into the solid specimen under low gravity conditions. No bubble detachment from the interface was observed. Identical specimens processed in the laboratory showed bubble nucleation, bubble growth, and eventual bubble detachment due to buoyancy forces. Examination of the specimens showed a significantly greater void content in the low gravity processed samples. The grain size was observed to be finer in the low gravity processed samples.

Papazian, J. M.↗

Migration and generation of contaminants from launch through recovery: LDEF case history

It is possible to recreate the contamination history of the Long Duration Exposure Facility (LDEF) through an analysis of its contaminants and selective samples that were collected from surfaces with better documented exposure histories. This data was then used to compare estimates based on monitoring methods that were selected for the purpose of tracking LDEF's exposure to contaminants. The LDEF experienced much more contamination than would have been assumed based on the monitors. Work is still in progress but much of what was learned so far is already being used in the selection of materials and in the design of systems for space. Now experiments are being prepared for flight to resolve questions created by the discoveries on the LDEF. A summary of what was learned about LDEF contaminants over the first year since recovery and deintegration is presented. Over 35 specific conclusions in 5 contamination related categories are listed.

Crutcher, E. R.↗

Advanced flight experiment automation development

NASA's space science program suffers under operational constraints that severely limit scientific reactivity. We describe a possible extension to an existing system that enables space science to be conducted in a more reactive manner through advanced automation techniques that have recently been used in the Space Transportation System (STS)-based Spacelab. This automation allows sophisticated autonomous control of the experiment by monitoring and dynamically controlling the progress of the experiment protocol. This new approach permits intelligent conduct of experimental research investigations whether or not the crew is available or contact with the ground is possible. We describe an intelligent software assistant that can manage the conduct of the experiment autonomously, by providing responsive telepresence science, or by assisting the astronaut operator with scientific advice. The crew could be unavailable for short periods when the experiment has low priority, or for longer periods on partially tended Space Station. We suggest this system could be developed as a ground prototype using commercial hardware, versions of which have been flight qualified, in order to provide a natural transition path towards flight use. In order to make this demonstration most valuable, we propose not to select a particular Life Sciences experiment, but to include an experiment simulator representative of major scientific domains.

Groleau, Nicolas↗