Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocols”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Implementation of two-party protocols in the noisy-storage model

The noisy-storage model allows the implementation of secure two-party protocols under the sole assumption that no large-scale reliable quantum storage is available to the cheating party. No quantum storage is thereby required for the honest parties. Examples of such protocols include bit commitment, oblivious transfer, and secure identification. Here, we provide a guideline for the practical implementation of such protocols. In particular, we analyze security in a practical setting where the honest parties themselves are unable to perform perfect operations and need to deal with practical problems such as errors during transmission and detector inefficiencies. We provide explicit security parameters for two different experimental setups using weak coherent, and parametric down-conversion sources. In addition, we analyze a modification of the protocols based on decoy states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Perspectives for laboratory implementation of the Duan-Lukin-Cirac-Zoller protocol for quantum repeaters

We analyze the efficiency and scalability of the Duan-Lukin-Cirac-Zoller (DLCZ) protocol for quantum repeaters focusing on the behavior of the experimentally accessible measures of entanglement for the system, taking into account crucial imperfections of the stored entangled states. We calculate then the degradation of the final state of the quantum-repeater linear chain for increasing sizes of the chain, and characterize it by a lower bound on its concurrence and the ability to violate the Clausner-Horne-Shimony-Holt inequality. The states are calculated up to an arbitrary number of stored excitations, as this number is not fundamentally bound for experiments involving large atomic ensembles. The measurement by avalanche photodetectors is modeled by ''ON/OFF'' positive operator-valued measure operators. As a result, we are able to consistently test the approximation of the real fields by fields with a finite number of excitations, determining the minimum number of excitations required to achieve a desired precision in the prediction of the various measured quantities. This analysis finally determines the minimum purity of the initial state that is required to succeed in the protocol as the size of the chain increases. We also provide a more accurate estimate for the average time required to succeed in each step of the protocol. The minimum purity analysis and the new time estimates are then combined to trace the perspectives for implementation of the DLCZ protocol in present-day laboratory setups.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

N - V –Diamond Magnetic Microscopy Using a Double Quantum 4-Ramsey Protocol

We introduce a double quantum (DQ) 4-Ramsey measurement protocol that enables wide-field magnetic imaging using nitrogen-vacancy (N-V) centers in diamond, with enhanced homogeneity of the magnetic sensitivity relative to conventional single quantum (SQ) techniques. The DQ 4-Ramsey protocol employs microwave-phase alternation across four consecutive Ramsey (4-Ramsey) measurements to isolate the desired DQ magnetic signal from any residual SQ signal induced by microwave pulse errors. In a demonstration experiment employing a 1-μm-thick N-V layer in a macroscopic diamond chip, the DQ 4-Ramsey protocol provides a volume-normalized dc magnetic sensitivity of η V = 34nTHz –1/2 μm 3/2 across a 125 μm × 125 μm field of view, with about 5× less spatial variation in sensitivity across the field of view compared to a SQ measurement. Furthermore, the improved robustness and magnetic sensitivity homogeneity of the DQ 4-Ramsey protocol enables imaging of dynamic broadband magnetic sources such as integrated circuits and electrically active cells.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dosimetry protocol for the forthcoming clinical trials in synchrotron stereotactic radiation therapy (SSRT)

Purpose: An adequate dosimetry protocol for synchrotron radiation and the specific features of the ID17 Biomedical Beamline at the European Synchrotron Radiation Facility are essential for the preparation of the forthcoming clinical trials in the synchrotron stereotactic radiation therapy (SSRT). The main aim of this work is the definition of a suitable protocol based on standards of dose absorbed to water. It must allow measuring the absolute dose with an uncertainty within the recommended limits for patient treatment of 2%-5%. Methods: Absolute dosimetry is performed with a thimble ionization chamber (PTW semiflex 31002) whose center is positioned at 2 g cm{sup -2} equivalent depth in water. Since the available synchrotron beam at the ESRF Biomedical Beamline has a maximum height of 3 mm, a scanning method was employed to mimic a uniform exposition of the ionization chamber. The scanning method has been shown to be equivalent to a broad beam irradiation. Different correction factors have been assessed by using Monte Carlo simulations. Results: The absolute dose absorbed to water at 80 keV was measured in reference conditions with a 2% global uncertainty, within the recommended limits. The dose rate was determined to be in the range between 14 and 18 Gy/min, that is to say, a factor two to three times higher than the 6 Gy/min achievable in RapidArc or VMAT machines. The dose absorbed to water was also measured in a RW3 solid water phantom. This phantom is suitable for quality assurance purposes since less than 2% average difference with respect to the water phantom measurements was found. In addition, output factors were assessed for different field sizes. Conclusions: A dosimetry protocol adequate for the specific features of the SSRT technique has been developed. This protocol allows measuring the absolute dose absorbed to water with an accuracy of 2%. It is therefore satisfactory for patient treatment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-113: The Influence of Optimizing Pediatric CT Simulator Protocols On the Treatment Dose Calculation in Radiotherapy

Purpose: To investigate the possibility of applying optimized scanning protocols for pediatric CT simulation by quantifying the dosimetric inaccuracy introduced by using a fixed HU to density conversion. Methods: The images of a CIRS electron density reference phantom (Model 062) were acquired by a Siemens CT simulator (Sensation Open) using the following settings of tube voltage and beam current: 120 kV/190mA (the reference protocol used to calibrate CT for our treatment planning system (TPS)); Fixed 190mA combined with all available kV: 80, 100, and 140; fixed 120 kV and various current from 37 to 444 mA (scanner extremes) with interval of 30 mA. To avoid the HU uncertainty of point sampling in the various inserts of known electron densities, the mean CT numbers of the central cylindrical volume were calculated using DICOMan software. The doses per 100 MU to the reference point (SAD=100cm, Depth=10cm, Field=10X10cm, 6MV photon beam) in a virtual cubic phantom (30X30X30cm) were calculated using Eclipse TPS (calculation model: AcurosXB-11031) by assigning the CT numbers to HU of typical materials acquired by various protocols. Results: For the inserts of densities less than muscle, CT number fluctuations of all protocols were within the tolerance of 10 HU as accepted by AAPM-TG66. For more condensed materials, fixed kV yielded stable HU with any mA combination where largest disparities were found in 1750mg/cc insert: HU{sub reference}=1801(106.6cGy), HU{sub minimum}=1799 (106.6cGy, error{sub dose}=0.00%), HU{sub maximum}=1815 (106.8cGy, error{sub dose}=0.19%). Yet greater disagreements were observed with increasing density when kV was modified: HU{sub minimum}=1646 (104.5cGy, error{sub dose}=- 1.97%), HU{sub maximum}=2487 (116.4cGy, error{sub dose}=9.19%) in 1750mg/cc insert. Conclusion: Without affecting treatment dose calculation, personalized mA optimization of CT simulator can be conducted by fixing kV for a better cost-effectiveness of imaging dose and quality especially for children. Unless recalibrated, kV should be constant for all anatomical sites if diagnostic CT scanner is used as a simulator. This work was partially supported by Capital Medical Development Scientific Research Fund of China.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-C-12A-07: Characterization of Longitudinal Reproducibility of Quantitative Diffusion Imaging Data Acquired with Four Different Protocols Using a Phantom

Purpose: To characterize and compare the longitudinal reproducibility of diffusion imaging data acquired with four different protocols using a phantom. Methods: The Diffusive Quantitative Imaging Phantom (DQIP) was constructed using fifteen cylindrical compartments within a larger compartment, filled with deionized water doped with CuSO4 and NaCl. The smaller compartments contained arrays of hexagonal or cylindrical glass capillaries of varying inner diameters, for differing restraint of water diffusion. The sensitivity of diffusion imaging metrics to signal-to-noise ratio (SNR) was probed by doping compartments with differing ratios of deuterium oxide to H2O. A cork phantom enclosure was constructed to increase thermal stability during scanning and a cork holder was made to reproduce scanner positioning. Four different protocols of DWI (diffusion weighted imaging) and DTI (Diffusion tensor imaging) imaging were assembled on a GE Excite HDx 3.0T MRI scanner to collect imaging data over 9-10 days. Data was processed with in-house software created in Matlab to obtain fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values. Results: All DTI and DWI sequences showed good longitudinal stability of mean FA and ADC values per compartment, exhibiting low standard deviation ∼9%. A t-test was performed to compare mean FA values from the DTI clinical protocol to those of the DTI special protocol, indicating significantly different values in the majority of compartments. ANOVA performed on ADC values for all DTI and DWI sequences also showed significantly different values in a majority of compartments. Conclusion: This work has the potential for quantifying systemic variations between diffusion imaging sequences from different platforms. Characterization of DWI and DTI performance were done over four sequences with predictable results. This data suggests that the DQIP phantom may be a reliable method of monitoring day-to-day and scan-to-scan variation in diffusion imaging sequences from different platforms. Schott Glass North America and The Phantom Laboratory have donated materials and personnel time to this project.

60 APPLIED LIFE SCIENCES↗

TH-C-12A-07: Implementation of a Pulsed Low Dose Date Radiotherapy (PLRT) Protocol for Recurrent Cancers Using Advanced Beam Delivery

Purpose: Recent in vitro and in vivo experimental findings provided strong evidence that pulsed low-dose-rate radiotherapy (PLDR) produced equivalent tumor control as conventional radiotherapy with significantly reduced normal tissue toxicities. This work aimed to implement a PLDR clinical protocol for the management of recurrent cancers utilizing IMRT and VMAT. Methods: Our PLDR protocol requires that the daily 2Gy dose be delivered in 0.2Gy×10 pulses with a 3min interval between the pulses. To take advantage of low-dose hyper-radiosensitivity the mean dose to the target is set at 0.2Gy and the maximum dose is limited to 0.4Gy per pulse. Practical planning strategies were developed for IMRT and VMAT: (1) set 10 ports for IMRT and 10 arcs for VMAT with each angle/arc as a pulse; (2) set the mean dose (0.2Gy) and maximum dose (0.4Gy) to the target per pulse as hard constraints (no constraints to OARs); (3) select optimal port/arc angles to avoid OARs; and (4) use reference structures in or around target/OARs to reduce maximum dose to the target/OARs. IMRT, VMAT and 3DCRT plans were generated for 60 H and N, breast, lung, pancreas and prostate patients and compared. Results: All PLDR treatment plans using IMRT and VMAT met the dosimetry requirements of the PLDR protocol (mean target dose: 0.20Gy±0.01Gy; maximum target dose < 0.4Gy). In comparison with 3DCRT, IMRT and VMAT exhibited improved target dose conformity and OAR dose sparing. A single arc can minimize the difference in the target dose due to multi-angle incidence although the delivery time is longer than 3DCRT and IMRT. Conclusion: IMRT and VMAT are better modalities for PLDR treatment of recurrent cancers with superior target dose conformity and critical structure sparing. The planning strategies/guidelines developed in this work are practical for IMRT/VMAT treatment planning to meet the dosimetry requirements of the PLDR protocol.

60 APPLIED LIFE SCIENCES↗

WE-E-304-02: Implementing SBRT Protocols: A NRG CIRO Perspective

SBRT is having a dramatic impact on radiation therapy of early-stage, locally advanced cancers. A number of national protocols have been and are being developed to assess the clinical efficacy of SBRT for various anatomical sites, such as lung and spine. Physics credentialing for participating and implementation of trial protocols involve a broad spectrum of requirements from image guidance, motion management, to planning technology and dosimetric constrains. For radiation facilities that do not have extensive experiences in SBRT treatment and protocol credentialing, these complex processes of credentialing and implementation could be very challenging and, sometimes, may lead to ineffective even unsuccessful execution of these processes. In this proposal, we will provide comprehensive review of some current SBRT protocols, explain the requirements and their underline rationales, illustrate representative failed and successful experiences, related to SBRT credentialing, and discuss strategies for effective SBRT credentialing and implementation. Learning Objectives: Understand requirements and challenges of SBRT credentailing and implentation Discuss processes and strategies of effective SBRT credentailing Discuss practical considerations, potential pitfalls and solutions of SBRT implentation.

60 APPLIED LIFE SCIENCES↗

WE-E-304-00: Implementing SBRT Protocols

SBRT is having a dramatic impact on radiation therapy of early-stage, locally advanced cancers. A number of national protocols have been and are being developed to assess the clinical efficacy of SBRT for various anatomical sites, such as lung and spine. Physics credentialing for participating and implementation of trial protocols involve a broad spectrum of requirements from image guidance, motion management, to planning technology and dosimetric constrains. For radiation facilities that do not have extensive experiences in SBRT treatment and protocol credentialing, these complex processes of credentialing and implementation could be very challenging and, sometimes, may lead to ineffective even unsuccessful execution of these processes. In this proposal, we will provide comprehensive review of some current SBRT protocols, explain the requirements and their underline rationales, illustrate representative failed and successful experiences, related to SBRT credentialing, and discuss strategies for effective SBRT credentialing and implementation. Learning Objectives: Understand requirements and challenges of SBRT credentailing and implentation Discuss processes and strategies of effective SBRT credentailing Discuss practical considerations, potential pitfalls and solutions of SBRT implentation.

60 APPLIED LIFE SCIENCES↗

TU-D-201-03: Results of a Survey On the Implementation of the TG-51 Protocol and Associated Addendum On Reference Dosimetry of External Beams

Purpose: The working group on the review and extension of the TG-51 protocol (WGTG51) collected data from American Association of Physicists in Medicine (AAPM) members with respect to their current TG-51 and associated addendum usage in the interest of considering future protocol addenda and guidance on reference dosimetry best practices. This study reports an overview of this survey on dosimetry of external beams. Methods: Fourteen survey questions were developed by WGTG51 and released in November 2015. The questions collected information on reference dosimetry, beam quality specification, and ancillary calibration equipment. Results: Of the 190 submissions completed worldwide (U.S. 70%), 83% were AAPM members. Of the respondents, 33.5% implemented the TG-51 addendum, with the maximum calibration difference for any photon beam, with respect to the original TG-51 protocol, being <1% for 97.4% of responses. One major finding is that 81.8% of respondents used the same cylindrical ionization chamber for photon and electron dosimetry, implying that many clinics are foregoing the use of parallel-plate chambers. Other evidence suggests equivalent dosimetric results can be obtained with both cylindrical and parallel-plate chambers in electron beams. This, combined with users comfort with cylindrical chambers for electrons will likely impact recommendations put forward in an upcoming electron beam addendum to the TG-51 protocol. Data collected on ancillary equipment showed 58.2% (45.0%) of the thermometers (barometers) in use for beam calibration had NIST traceable calibration certificates, but 48.4% (42.7%) were never recalibrated. Conclusion: This survey provides a snapshot of TG-51 external beam reference dosimetry practice in radiotherapy centers. Findings demonstrate the rapid take-up of the TG-51 photon beam addendum and raise issues for the WGTG51 to focus on going forward, including guidelines on ancillary equipment and the choice of chamber for electron beam dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-H-207A-09: An Automated Technique for Estimating Patient-Specific Regional Imparted Energy and Dose From TCM CT Exams Across 13 Protocols

Purpose: To develop an automated technique for estimating patient-specific regional imparted energy and dose from tube current modulated (TCM) computed tomography (CT) exams across a diverse set of head and body protocols. Methods: A library of 58 adult computational anthropomorphic extended cardiac-torso (XCAT) phantoms were used to model a patient population. A validated Monte Carlo program was used to simulate TCM CT exams on the entire library of phantoms for three head and 10 body protocols. The net imparted energy to the phantoms, normalized by dose length product (DLP), and the net tissue mass in each of the scan regions were computed. A knowledgebase containing relationships between normalized imparted energy and scanned mass was established. An automated computer algorithm was written to estimate the scanned mass from actual clinical CT exams. The scanned mass estimate, DLP of the exam, and knowledgebase were used to estimate the imparted energy to the patient. The algorithm was tested on 20 chest and 20 abdominopelvic TCM CT exams. Results: The normalized imparted energy increased with increasing kV for all protocols. However, the normalized imparted energy was relatively unaffected by the strength of the TCM. The average imparted energy was 681 ± 376 mJ for abdominopelvic exams and 274 ± 141 mJ for chest exams. Overall, the method was successful in providing patientspecific estimates of imparted energy for 98% of the cases tested. Conclusion: Imparted energy normalized by DLP increased with increasing tube potential. However, the strength of the TCM did not have a significant effect on the net amount of energy deposited to tissue. The automated program can be implemented into the clinical workflow to provide estimates of regional imparted energy and dose across a diverse set of clinical protocols.

60 APPLIED LIFE SCIENCES↗

TH-E-209-00: Radiation Dose Monitoring and Protocol Management

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

TH-E-209-02: Dose Monitoring and Protocol Optimization: The Pediatric Perspective

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

FACE-MDS Phase 2: Meteorological Data and Protocols

This dataset contains meteorological data, site parameterization data, and protocols for simulation of the five Free Air CO2 Enrichment (FACE) experiments and one Open Top Chamber (OTC) experiment that were the study sites of the FACE Model Data Synthesis (FACE-MDS) project. This dataset should contain everything necessary to simulate these six CO2 enrichment experiments -- Duke, Kennedy Space Center, NDFF, ORNL, PHACE, and Rhinelander -- following the FACE-MDS simulation protocol. Data cover 1998-2008 (1998-01-01 to 2008-12-31). File naming convention can be found in the file 'facemds-file-table-metdata.xml' and information about variable naming convention can be found in the file 'facemds-standard-name-table-metvars.xml'. Where possible, Assistance for the Land-surface Modelling Activities (ALMA) v3 convention for meteorological variables naming ontology was followed. Additional info can be found in the user guide, protocol documents, and readmes in this dataset. The original naming convention mentioned in the protocol was replaced with the one described in 'facemds-standard-name-table-modvars.xml' in the accompanying dataset (doi:10.15485/1480327). The dataset contains 21 data files that are available in comma-separate (*.csv), plain text (*.txt), and NetCDF (*.nc) format. Nine companion files and additional metadata are provided: three data dictionaries and a file-level metadata file in comma separate (.csv) format and a user guide in PDF (*.pdf) format. This dataset was updated on 2026-06-02 to add a version of the data files in comma separate (.csv) format, a user guide, data dictionary files, and a file-level metadata file. No previously released data values were changed.

54 ENVIRONMENTAL SCIENCES↗

Quality Assurance Protocol for AFCI Advanced Structural Materials Testing

The objective of this letter is to inform you of recent progress on the development of advanced structural materials in support of advanced fast reactors and AFCI. As you know, the alloy development effort has been initiated in recent months with the procurement of adequate quantities of the NF616 and HT-UPS alloys. As the test alloys become available in the coming days, mechanical testing, evaluation of optimizing treatments, and screening of environmental effects will be possible at a larger scale. It is therefore important to establish proper quality assurance protocols for this testing effort in a timely manner to ensure high technical quality throughout testing. A properly implemented quality assurance effort will also enable preliminary data taken in this effort to be qualified as NQA-1 during any subsequent licensing discussions for an advanced design or actual prototype. The objective of this report is to describe the quality assurance protocols that will be used for this effort. An essential first step in evaluating quality protocols is assessing the end use of the data. Currently, the advanced structural materials effort is part of a long-range, basic research and development effort and not, as yet, involved in licensing discussions for a specific reactor design. After consultation with Mark Vance (an ORNL QA expert) and based on the recently-issued AFCI QA requirements, the application of NQA-1 quality requirements will follow the guidance provided in Part IV, Subpart 4.2 of the NQA-1 standard (Guidance on Graded Application of QA for Nuclear-Related Research and Development). This guidance mandates the application of sound scientific methodology and a robust peer review process in all phases, allowing for the data to be qualified for use even if the programmatic mission changes to include licensing discussions of a specific design or prototype. ORNL has previously implemented a QA program dedicated to GNEP activities and based on an appropriately graded application of NQA-1 requirements at the site. The current program is being revised to incorporate changes imposed through the recently revised AFCI Technical Integration Office QA requirements. Testing conducted under the AFCI QA program for the advanced structural materials effort shall incorporate the following quality assurance expectations: (1) personnel are adequately trained to perform assigned work; (2) activities are controlled to ensure consistency of results; (3) records necessary to substantiate how the work was performed are maintained (dedicated laboratory notebooks will be used); (4) the pedigree and traceability of the various tested materials are maintained throughout the described processes using consistent sample numbering and adequate record keeping; (5) equipment with the potential to affect the quality of the planned work is calibrated and maintained in accordance with applicable operating requirements. In addition, all reporting or related dissemination by ORNL personnel of the results of the work described in this subcontract shall be conducted in accordance with the requirements described or referenced in the ORNL Standards Based Management System subject area entitled Scientific and Technical Information. Reporting or publications at other institutions will be conducted in accordance with the requirements of that institution. Successful implementation of these protocols will provide a sound basis for future decisions and research. In addition, these steps will also help ensure that results can also be applied to licensing discussions at a future date.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Joint Architecture Standard (JAS) Reliable Data Delivery Protocol (RDDP) specification.

The Joint Architecture Standard (JAS) program at Sandia National Laboratories requires the use of a reliable data delivery protocol over SpaceWire. The National Aeronautics and Space Administration at the Goddard Spaceflight Center in Greenbelt, Maryland, developed and specified a reliable protocol for its Geostationary Operational Environment Satellite known as GOES-R Reliable Data Delivery Protocol (GRDDP). The JAS program implemented and tested GRDDP and then suggested a number of modifications to the original specification to meet its program specific requirements. This document details the full RDDP specification as modified for JAS. The JAS Reliable Data Delivery Protocol uses the lower-level SpaceWire data link layer to provide reliable packet delivery services to one or more higher-level host application processes. This document specifies the functional requirements for JRDDP but does not specify the interfaces to the lower- or higher-level processes, which may be implementation-dependent.

99 GENERAL AND MISCELLANEOUS↗

PROTOCOL FOR EXAMINATION OF THE INNER CAN CLOSURE WELD REGION FOR 3013 DE CONTAINERS

The protocol for the examination of the inner can closure weld region (ICCWR) for 3013 DE containers is presented within this report. The protocol includes sectioning of the inner can lid section, documenting the surface condition, measuring corrosion parameters, and storing of samples. This protocol may change as the investigation develops since findings may necessitate additional steps be taken. Details of the previous analyses, which formed the basis for this protocol, are also presented.

42 ENGINEERING↗

Documentation of operational protocol for the use of MAMA software

Image analysis of Scanning Electron Microscope (SEM) micrographs is a complex process that can vary significantly between analysts. The factors causing the variation are numerous, and the purpose of Task 2b is to develop and test a set of protocols designed to minimize variation in image analysis between different analysts and laboratories, specifically using the MAMA software package, Version 2.1. The protocols were designed to be “minimally invasive”, so that expert SEM operators will not be overly constrained in the way they analyze particle samples. The protocols will be tested using a round-robin approach where results from expert SEM users at Los Alamos National Laboratory, Lawrence Livermore National Laboratory, Pacific Northwest National Laboratory, Savannah River National Laboratory, and the National Institute of Standards and Testing will be compared. The variation of the results will be used to quantify uncertainty in the particle image analysis process. The round-robin exercise will proceed with 3 levels of rigor, each with their own set of protocols, as described below in Tasks 2b.1, 2b.2, and 2b.3. The uncertainty will be developed using NIST standard reference material SRM 1984 “Thermal Spray Powder – Particle Size Distribution, Tungsten Carbide/Cobalt (Acicular)” [Reference 1]. Full details are available in the Certificate of Analysis, posted on the NIST website (http://www.nist.gov/srm/).

97 MATHEMATICS AND COMPUTING↗