Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulsed field magnetization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

In situ amplification of spin echoes within a kinetic inductance parametric amplifier

The use of superconducting microresonators together with quantum-limited Josephson parametric amplifiers has enhanced the sensitivity of pulsed electron spin resonance (ESR) measurements by more than four orders of magnitude. So far, the microwave resonators and amplifiers have been designed as separate components due to the incompatibility of Josephson junction–based devices with magnetic fields. This has produced complex spectrometers and raised technical barriers toward adoption of the technique. Here, we circumvent this issue by coupling an ensemble of spins directly to a weakly nonlinear and magnetic field–resilient superconducting microwave resonator. We perform pulsed ESR measurements with a 1-pL mode volume containing 6 × 10 7 spins and amplify the resulting signals within the device. When considering only those spins that contribute to the detected signals, we find a sensitivity of 2.8 x 10 3 spins / $\sqrt{Hz}$ for a Hahn echo sequence at a temperature of 400 mK. In situ amplification is demonstrated at fields up to 254 mT, highlighting the technique’s potential for application under conventional ESR operating conditions.

42 ENGINEERING↗

Experimental determination of the thermal, turbulent, and rotational ion motion and magnetic field profiles in imploding plasmas

A tutorial is presented on advances in spectroscopic diagnostic methods developed for measuring key plasma properties in pulsed-power systems such as Z-pinches, magnetized-plasma compression devices, ion and electron diodes, and plasma switches. The parameters measured include the true ion temperature in Z-pinch implosions, which led to a discovery that much of the ion kinetic energy at stagnation is stored in hydrodynamic rather than in thermal motion. This observation contributed a new important insight into the understanding of the ion thermalization at stagnation and stimulated further investigations of turbulence at stagnation, discussed here too. The second part of this tutorial is devoted to the development of measurements for magnetic-field distributions in Z-pinches and in other pulsed-power systems, as well as their use in studying the plasma dynamics, resistivity, and pressure and energy balance. The latter study raises intriguing questions on the implosion process. In particular, in Z-pinches, the current during stagnation was found to largely flow at relatively large radii, outside the stagnation region. The magnetic-field measurements also enable investigations into the compression of a pre-magnetized cylindrical plasma that uncover striking phenomena related to the current flow, where the current was found to redistribute toward the outer regions during the implosion. Observation of the rotation of the magnetized plasma is also discussed. Lastly, experimental and theoretical investigations of a non-diffusive fast penetration of magnetic field into a low-density plasma, including its effect on the plasma dynamics, are described

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrically writing a magnetic heliknoton in a chiral magnet

A magnetic heliknoton is the three-dimensional counterpart to the two-dimensional magnetic skyrmion, and serves as a pivotal topological soliton for extending topological magnetism into three dimensions. However, its experimental realization remains elusive. Here we report the controlled nucleation of a magnetic heliknoton in the chiral magnet FeGe at zero magnetic field, achieved through nanoscale current-pulse excitation. By combining angle-dependent quantitative electron holography with micromagnetic simulations, we resolve the three-dimensional spin texture of the heliknoton. In particular, the heliknoton exhibits current-driven collinear motion without the Hall effect. Furthermore, our findings establish a readily accessible experimental platform for further exploration of three-dimensional topological solitons and highlight their potential for practical applications.

Magnetic properties and materials↗

Deflection of Plasma by High Magnetic Fields at Variable Pressures (Final Report)

The goal of the proposed work is to study the deflection of plasma by high magnetic fields using the high uniform magnetic field of the Magnetized Dusty Plasma Experiment (MDPX) located at the Magnetized Plasma Research Laboratory (MPRL) at Auburn University. The proposal team consists of faculty from the University of Alabama in Huntsville (UAH). One of the motivations for this work is to study the concept of a magnetic nozzle for pulsed fusion propulsion. Fusion propulsion can provide extremely high specific impulse, >30,000 sec, for fuel-efficient and thus mass-efficient trips to other planets. One such fusion propulsion design of interest in this research is the Pulsed Fission-Fusion (PuFF) concept. PuFF uses a Z-pinch device to create a fusion reaction at the back of the spacecraft inside the magnetic nozzle. As the resulting plasma explosion is isotropic, a large portion of the momentum will be directed toward the ship and needs to be redirected to efficiently produce thrust. The magnetic nozzle is thus necessary to redirect or deflect the plasma from an isotropic expansion into the directed thrust. Thus, the pulsed-fusion propulsion nozzle is herein referred to as a deflection magnetic nozzle, as opposed to the more traditional and well-studied accelerating magnetic nozzle. The purpose of this project was thus to study the behavior of a plasma in the MDPX fields to better understand the plasma-field interactions and how it could lead to deflection and a pulsed fusion magnetic nozzle.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Confinement of relativistic electrons in a magnetic mirror en route to a magnetized relativistic pair plasma

Creating a magnetized relativistic pair plasma in the laboratory would enable the exploration of unique plasma physics relevant to some of the most energetic events in the universe. As a step toward a laboratory pair plasma, we have demonstrated an effective confinement of multi-MeV electrons inside a pulsed-power-driven 13 T magnetic mirror field with a mirror ratio of 2.6. The confinement is diagnosed by measuring the axial and radial losses with magnetic spectrometers. The loss spectra are consistent with ≤2.5 MeV electrons confined in the mirror for ∼1 ns. With a source of 1012 electron-positron pairs at comparable energies, this magnetic mirror would confine a relativistic pair plasma with Lorentz factor γ∼6 and magnetization σ∼40.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quick-connect scanning tunneling microscope head with nested piezoelectric coarse walkers

To meet changing research demands, new scanning tunneling microscope (STM) features must constantly evolve. We describe the design, development, and performance of a modular plug-in STM, which is compact and stable. The STM head is equipped with a quick-connect socket that is matched to a universal connector plug, enabling it to be transferred between systems. This head can be introduced into a vacuum system via a load-lock and transferred to various sites equipped with the connector plug, permitting multi-site STM operation. Its design allows for reliable operation in a variety of experimental conditions, including a broad temperature range, ultra-high vacuum, high magnetic fields, and closed-cycle pulse-tube cooling. The STM’s compact size is achieved by a novel nested piezoelectric coarse walker design, which allows for large orthogonal travel in the X, Y, and Z directions, ideal for studying both bulk and thin film samples ranging in size from mm to μm. Its stability and noise tolerance are demonstrated by achieving atomic resolution under ambient conditions on a laboratory desktop with no vibrational or acoustic isolation. The operation of the nested coarse walkers is demonstrated by successful navigation to a μm-sized 2D sample.

Instruments & Instrumentation↗

Advanced magnetic X-ray spectro-microscopies to characterize mesoscopic magnetic materials

Here, this article provides a brief overview of advanced magnetic X-ray spectro-microscopies that are widely used in characterizing mesoscopic magnetic materials. Common to those techniques are various X-ray magnetic dichroism effects that are used as magnetic contrast mechanism. A particular interest is to use those techniques to image the underlying microscopic spin structures in magnetic materials with high spatial resolution and to ultimately resolve their full 3D mesoscale characteristics with elemental sensitivity, as well as their ultrafast dynamics upon excitations with field and current pulses. Recent research examples using various magnetic X-ray spectro-microscopies are presented to showcase their specific features with a focus on imaging novel topological spin textures, such as vortices, skyrmions and Hopfions, which are considered as potential building blocks towards low power, high-speed and high-density magnetic devices that could transform information technologies and potentially be used in biomedical applications. Future developments with magnetic X-ray spectro-microscopies harness the full coherence of next generation X-ray sources and could open the path towards single shot imaging with spatial and temporal resolutions down to fundamental magnetic length and time scales.

36 MATERIALS SCIENCE↗

Non-Equilibrium Effects in Quantum Magnets

While most often the state of a material will tend toward an equilibrium determined by its environment, there are many cases of scientific and technological interest where materials are manipulated to be or are found in non-equilibrium configurations. For example, data can be stored in hard drives by deliberately altering the magnetic orientation in a material to store information in non-equilibrium pattern. In this project, the main goals were studies of non-equilibrium properties of quantum magnets using neutron scattering as the primary experimental method. Neutron scattering allows characterization of magnetic correlation lengths sensitive to the presence of defects. It can also be used to distinguish equilibrium from non-equilibrium states via energy transfer rates. Typical bulk state magnetization relaxation times are too short to perform many neutron scattering measurements of interest. To enable the study of non-equilibrium conditions, materials with longer magnetic relaxation times were targeted. CoNb 2 O 6 was used in two experiments related to non-equilibrium physics. In the first, evidence for defects created via the Kibble-Zurek mechanism (KZM) was sought by quenching across a magnetic field-dependent phase transition. Somewhat unexpectedly, clear evidence for KZM-induced defects was absent. Additional measurements of CoNb 2 O 6 were made to better characterize its crystal field and other properties to provide a better theoretical understanding to enable more effective non-equilibrium physics measurements. In another project, LiHo 0.45 Y 0.55 F 4 was used to compare a quantum annealing protocol to a thermal annealing one since magnetic fields can be used to control the thermal fluctuations in LiHo 0.45 Y 0.55 F 4 . In addition, a new pulsed magnet power supply and new techniques were developed suitable for neutron scattering experimental environments to enable faster magnetic field changes for producing non-equilibrium conditions. The power supply developed for this project has wider technological applications in addition to faster magnetic field ramps.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Delivering Robust Proton-Only Sensing of Hyperpolarized [1,2- 13 C 2 ]-Pyruvate Using Broad-Spectral-Range Nuclear Magnetic Resonance Pulse Sequences

Hyperpolarized [1- 13 C]pyruvate is the leading hyperpolarized injectable contrast agent and is currently under evaluation in clinical trials for molecular imaging of metabolic diseases, including cardiovascular disease and cancer. One aspect limiting broad scalability of the technique is that hyperpolarized 13 C MRI requires specialized 13 C hardware and software that are not generally available on clinical MRI scanners, which employ proton-only detection. Here, we present an approach that uses pulse sequences to transfer 13 C hyperpolarization to methyl protons for detection of the 13 C– 13 C pyruvate singlet, employing proton-only excitation and detection only. The new pulse sequences are robust to the B 1 and B 0 magnetic field inhomogeneities. The work focuses on singlet-to-magnetization (S2M) and rotor-synchronized (R) pulses, both relying on trains of hard pulses with broad spectral width coverage designed to effectively transform hyperpolarized 13 C 2 -singlet hyperpolarization to 1 H polarization on the CH 3 group of [1,2- 13 C 2 ]pyruvate. Finally, this approach may enable a broader adoption of hyperpolarized MRI as a molecular imaging technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Specialized diamond materials for NMR applications

Polarizable diamond materials and methods for obtaining nuclear magnetic resonance spectra of samples external to the diamond materials are described. The diamond materials can include 12C, 13C, substitutional nitrogen, and nitrogen vacancy defects in a crystalline lattice, wherein the substitutional nitrogen concentration is between 10 ppm and 200 ppm, the nitrogen vacancy concentration is between 10 ppb and 10 ppm, and the 13C concentration is greater than 1.1% and not more than 25%. Methods for obtaining nuclear magnetic resonance spectra can include optically pumping a diamond material to generate electron spin hyperpolarization in nitrogen vacancy centers, transferring the electron spin hyperpolarization to nuclei of the sample, and generating a nuclear magnetic resonance spectrum by applying a magnetic field to the sample, exciting the sample with a radio frequency pulse, and detecting a nuclear magnetic resonance response from the sample.

Parker, Alfred↗

The Physics of Micro-Pinches

This project focused on using pulsed-power-driven techniques to study the coupling of high-energy-density (HED) magnetic fields to HED matter in the laboratory. Specifically, we studied a phenomenon known as "micro-pinching" to obtain HED conditions on a modest, university-scale pulsed-power driver: the 1-MA, 100-ns MAIZE linear transformer driver (LTD) facility at the University of Michigan. We used the "X-pinch" platform as a means of generating micro-pinch HED plasmas. An X-pinch is formed when two or more wires are crossed into the shape of an 'X' and a large electrical current is driven through the wires. This creates an intense electrical current density at the crossing point of the wires. Associated with this current density is an intense magnetic field and an intense magnetic field pressure. The magnetic field pressure compresses and heats the wire material into the HEDP regime. The use of an X-pinch platform ensures that the micro-pinch HED plasma will form in a well-controlled location, which helps with diagnostics alignment. This platform allowed us to explore the extreme plasma conditions and magnetic field pressures that can be generated with compact pulsed-power technology and intensely focused discharge currents. Understanding the limits of intensely focused discharge currents could have an enormous impact on HED science, especially when one considers the scaling of these platforms to the 30-MA Z facility at Sandia National Laboratories, where pressures well in excess of 1 Gbar could be achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coherent control of asymmetric spintronic terahertz emission from two-dimensional hybrid metal halides

Abstract Next-generation terahertz (THz) sources demand lightweight, low-cost, defect-tolerant, and robust components with synergistic, tunable capabilities. However, a paucity of materials systems simultaneously possessing these desirable attributes and functionalities has made device realization difficult. Here we report the observation of asymmetric spintronic-THz radiation in Two-Dimensional Hybrid Metal Halides (2D-HMH) interfaced with a ferromagnetic metal, produced by ultrafast spin current under femtosecond laser excitation. The generated THz radiation exhibits an asymmetric intensity toward forward and backward emission direction whose directionality can be mutually controlled by the direction of applied magnetic field and linear polarization of the laser pulse. Our work demonstrates the capability for the coherent control of THz emission from 2D-HMHs, enabling their promising applications on the ultrafast timescale as solution-processed material candidates for future THz emitters.

36 MATERIALS SCIENCE↗

SPACE CHARGE EFFECT IN LOW ENERGY MAGNETIZED ELECTRON BEAM

Magnetized electron cooling is one of the major approaches towards obtaining the required high luminosity in the proposed Electron-Ion Collider (EIC). In order to increase the cooling efficiency, a bunched electron beam with a high bunch charge and high repetition rate is required. At Jefferson Lab, we generated magnetized electron beams with high bunch charge using a new compact DC high voltage photogun biased at -300 kV with bialkali-antimonide photocathode and a commercial ultra-fast laser. This contribution discusses how magnetization affects space charge dominated beams as a function of magnetic field strength, gun high voltage, and laser pulse width, and spot size in comparison with simulations performed using General Particle Tracer.

Wijethunga, S.A.K.↗

Efficient Optical Control of Magnon Dynamics in van der Waals Ferromagnets

Optical control of magnons in two-dimensional (2D) materials promises new functionalities for spintronics and magnonics in atomically thin devices. Here, we report control of magnon dynamics, using laser polarization, in a ferromagnetic van der Waals (vdW) material, Fe 3.6 Co 1.4 GeTe 2 . The magnon amplitude, frequency, and lifetime are controlled and monitored by time-resolved pump-probe spectroscopy. We show substantial (over 25%) and continuous modulation of magnon dynamics as a function of incident laser polarization. Our results suggest that the modification of the effective demagnetization field and magnetic anisotropy by the pump laser pulses with different polarizations is due to anisotropic optical absorption. This implies that pump laser pulses modify the local spin environment, which enables the launch of magnons with tunable dynamics. Our first-principles calculations confirm the anisotropic optical absorption of different crystal orientations. Our findings suggest a new route for the development of opto-spintronic or opto-magnonic devices.

36 MATERIALS SCIENCE↗

On the initiation and evolution of dielectric breakdown in auto-magnetizing liner experiments

Auto-magnetizing (AutoMag) liners are cylindrical tubes composed of discrete metallic helices encapsulated in insulating material; when driven with a ~2 MA, ~100-ns prepulse on the 20 MA, 100-ns rise time Z accelerator, AutoMag targets produced >150 T internal axial magnetic fields. Once the current rise rate of the pulsed power driver reaches sufficient magnitude, the induced electric fields in the liner cause dielectric breakdown of the insulator material and, with sufficient current, the cylindrical target radially implodes. The dielectric breakdown process of the insulating material in AutoMag liners has been studied in experiments on the 500–900 kA, ~100-ns rise time Mykonos accelerator. Multi-frame gated imaging enabled the first time-resolved observations of photoemission from dynamically evolving plasma distributions during the breakdown process in AutoMag targets. Using magnetohydrodynamic simulations, we calculate the induced electric field distribution and provide a detailed comparison to the experimental data. We find that breakdown in AutoMag targets does not primarily depend on the induced electric field in the gaps between conductive helices as previously thought. Finally, to better control the dielectric breakdown time, a 12–32 mJ, 170 ps ultraviolet (λ = 266 nm) laser was implemented to irradiate the outer surface of AutoMag targets to promote breakdown in a controlled manner at a lower internal axial field. Here, the laser had an observable effect on the time of breakdown and subsequent plasma evolution, indicating that pulsed UV lasers can be used to control breakdown timing in AutoMag.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray detection of ultrashort spin current pulses in synthetic antiferromagnets

Here, we explore the ultrafast generation of spin currents in magnetic multilayer samples by applying fs laser pulses to one layer and measuring the magnetic response in the other layer by element-resolved x-ray spectroscopy. In Ni(5 nm)/Ru(2 nm)/Fe(4 nm), the Ni and Fe magnetization directions couple antiferromagnetically due to the Ruderman–Kittel–Kasuya–Yosida interaction but may be oriented parallel through an applied magnetic field. After exciting the top Ni layer with a fs laser pulse, we also find that the Fe layer underneath demagnetizes, with a 4.1±1.9% amplitude difference between parallel and antiparallel orientation of the Ni and Fe magnetizations. We attribute this difference to the influence of a spin current generated by the fs laser pulse that transfers angular momentum from the Ni into the Fe layer. Our results confirm that superdiffusive spin transport plays a role in determining the sub-ps demagnetization dynamics of synthetic antiferromagnetic layers, but also evidence large depolarization effects due to hot electron dynamics, which are independent of the relative alignment of the magnetization in Ni and Fe.

36 MATERIALS SCIENCE↗