Richmond Disasters: Tracking and Assessing Stormwater Flooding in Richmond, Virginia to Improve Water Quality Monitoring and Resources Management
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In August 2009, an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE) technology was delivered to the International Space Station (ISS). The kit, called the Colorimetric Water Quality Monitoring Kit (CWQMK), was launched as a Station Development Test Objective (SDTO) experiment to evaluate the suitability of CSPE technology for routine use monitoring water quality on the ISS. CSPE is a sorption-spectrophotometric technique that combines colorimetric reagents, solid-phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water samples. In CSPE, a known volume of sample is metered through a membrane disk that has been impregnated with an analyte-specific colorimetric reagent and any additives required to optimize the formation of the analyte-reagent complex. As the sample flows through the membrane disk, the target analyte is selectively extracted, concentrated, and complexed. Formation of the analyte-reagent complex causes a detectable change in the color of the membrane disk that is proportional to the amount of analyte present in the sample. The analyte is then quantified by measuring the color of the membrane disk surface using a hand-held diffuse reflectance spectrophotometer (DRS). The CWQMK provides the capability to measure the ionic silver (Ag +) and molecular iodine (I2) in water samples on-orbit. These analytes were selected for the evaluation of CSPE technology because they are the biocides used in the potable water storage and distribution systems on the ISS. Biocides are added to the potable water systems on spacecraft to inhibit microbial growth. On the United States (US) segment of the ISS molecular iodine serves as the biocide, while the Russian space agency utilizes silver as a biocide in their systems. In both cases, the biocides must be maintained at a level sufficient to control bacterial growth, but low enough to avoid any negative effects on crew health. For example, the presence of high levels of iodine in water can cause taste and odor issues that result in decreased water consumption by the crew. There are also concerns about potential impacts on thyroid function following exposure to high levels of iodine. With silver, there is a risk of developing argyria, an irreversible blue-gray discoloration of the skin, associated with long term consumption of water containing high concentrations of silver. The need to ensure that safe, effective levels of biocide are maintained in the potable water systems on the ISS provides a perfect platform for evaluating the suitability of CSPE technology for in-flight water quality monitoring. This paper provides an overview of CSPE technology and details on the silver and iodine methods used in the CWQMK. It also reports results obtained during in-flight analyses performed with the CWQMK and briefly discusses other potential applications for CSPE technology in both the spacecraft and terrestrial environments.
Water quality monitoring possibilities from LANDSAT were demonstrated both for direct readings of reflectances from the water and indirect monitoring of changes in use of land surrounding Swift Creek Reservoir in a joint project with the Virginia State Water Control Board and NASA. Film products were shown to have insufficient resolution and all work was done by digitally processing computer compatible tapes. Land cover maps of the 18,000 hectare Swift Creek Reservoir watershed, prepared for two dates in 1974, are shown. A significant decrease in the pine cover was observed in a 740 hectare construction site within the watershed. A measure of the accuracy of classification was obtained by comparing the LANDSAT results with visual classification at five sites on a U-2 photograph. Such changes in land cover can alert personnel to watch for potential changes in water quality.
Data from satellite instruments provide estimates of gas and particle levels relevant to human health, even pollutants invisible to the human eye. However, the successful interpretation of satellite data requires an understanding of how satellites relate to other data sources, as well as factors affecting their application to health challenges. Drawing from the expertise and experience of the 2016–2020 NASA HAQAST (Health and Air Quality Applied Sciences Team), we present a review of satellite data for air quality and health applications. We include a discussion of satellite data for epidemiological studies and health impact assessments, as well as the use of satellite data to evaluate air quality trends, support air quality regulation, characterize smoke from wildfires, and quantify emission sources. The primary advantage of satellite data compared to in situ measurements, e.g., from air quality monitoring stations, is their spatial coverage. Satellite data can reveal where pollution levels are highest around the world, how levels have changed over daily to decadal periods, and where pollutants are transported from urban to global scales. To date, air quality and health applications have primarily utilized satellite observations and satellite-derived products relevant to near-surface particulate matter <2.5 μm in diameter (PM(sub 2.5)) and nitrogen dioxide (NO2). Health and air quality communities have grown increasingly engaged in the use of satellite data, and this trend is expected to continue. From health researchers to air quality managers, and from global applications to community impacts, satellite data are transforming the way air pollution exposure is evaluated.
Satellite images and low altitude aerial photographs often show vivid discolorations in water bodies. Extensive laboratory analysis shows that water reflectance, which causes brightness on aerial images, positively correlates to the water quality parameter of turbidity, which on a particular day correlates to suspended solids. Work with low altitude photography on three overcast days and with ERTS images on five clear days provides positive correlation of image brightness to the high turbidity and solids which are present in Lake Superior near Duluth over 50% of the time. Proper use of aerial images would have shown that an $8,000,000 drinking water intake constructed in the midst of this unpotable, turbid water should have been located 6 miles north in clear, usable water. Noise effects such as skylight reflection, atmospheric effects, and depth penetration also must be understood for operational use of remote sensing for water quality monitoring and are considered in the paper.
In an era marked by escalating environmental concerns, understanding the Earth's atmosphere and its complex interactions is paramount. The Tropospheric Emission Monitoring of POllution (TEMPO) instrument is a cutting-edge venture by NASA that stands at the forefront of Earth observation technology and exemplifies NASA's commitment to unraveling the intricacies of the air we breathe. TEMPO was launched with the primary objective of monitoring air quality. This story map explores the innovative technology behind the TEMPO instrument, its mission objectives, tools and services provided by the Atmospheric Science Data Center (ASDC) for data access and the potential impact of TEMPO data findings on our health and Earth's environmental future.
Laboratory prototype water quality monitoring system provides automatic system for online monitoring of chemical, physical, and bacteriological properties of recovered water and for signaling malfunction in water recovery system. Monitor incorporates whenever possible commercially available sensors suitably modified.
The MODIS and MISR aerosol products were designed nearly two decades ago for the purpose of climate applications. Since launch of Terra in 1999, these two sensors have provided global, quantitative information about column-integrated aerosol properties, including aerosol optical depth (AOD) and relative aerosol type parameters (such as Angstrom exponent). Although primarily designed for climate, the air quality (AQ) community quickly recognized that passive satellite products could be used for particulate air quality monitoring and forecasting. However, AOD and particulate matter (PM) concentrations have different units, and represent aerosol conditions in different layers of the atmosphere. Also, due to low visible contrast over brighter surface conditions, satellite-derived aerosol retrievals tend to have larger uncertainty in urban or populated regions. Nonetheless, the AQ community has made significant progress in relating column-integrated AOD at ambient relative humidity (RH) to surface PM concentrations at dried RH. Knowledge of aerosol optical and microphysical properties, ambient meteorological conditions, and especially vertical profile, are critical for physically relating AOD and PM. To make urban-scale maps of PM, we also must account for spatial variability. Since surface PM may vary on a finer spatial scale than the resolution of standard MODIS (10 km) and MISR (17km) products, we test higher-resolution versions of MODIS (3km) and MISR (1km research mode) retrievals. The recent (July 2011) DISCOVER-AQ campaign in the mid-Atlantic offers a comprehensive network of sun photometers (DRAGON) and other data that we use for validating the higher resolution satellite data. In the future, we expect that the wealth of aircraft and ground-based measurements, collected during DISCOVER-AQ, will help us quantitatively link remote sensed and ground-based measurements in the urban region.
Quality control monitoring system for satellite telemetry data information systems
The U.S. Army Corps of Engineers (USACE) and National Oceanic and Atmospheric Administration (NOAA) National Marine Fisheries Service (NMFS) will be supervising a harbor deepening project in Port Everglades, Florida. The project raises concerns about potential impacts on the nearby Florida reef tract through increased turbidity and sediment from the dredging. To better understand these potential impacts, the NASA DEVELOP team created an interactive Google Earth Engine tool to help establish a historical baseline of water quality parameters and assist monitoring these parameters more frequently than traditional sampling. This Seaport & Harbor Area Resource Quality (SHARQ) tool incorporates remotely sensed data from Sentinel-2 Multispectral Instrument, Landsat 5 Thematic Mapper, Landsat 7 Enhanced Thematic Mapper+, Landsat 8 Operational Land Imager, and Aqua Moderate Resolution Imaging Spectroradiometer. It allows users to view true color images and calculate water quality parameters, like turbidity and chlorophyll-a, for any given study area and time period from 1984 onward. The SHARQ tool also generate time series charts, allowing users to interpret changes in water quality over a given time range. The accuracy of the remotely sensed water quality parameter algorithms was determined using in situ data to calculate percent difference and root mean square error values (RMSE), which ranged from 0.32 to 0.58 error between sites. Using the SHARQ tool’s time series analysis feature, a baseline average turbidity metric of ~6.8 FNUs provides a historical baseline average for turbidity between September 2000 and 2020 and can assist in future decision-making for determining thresholds for turbidity.
LANDSAT-1 imagery has been used for water quality and land use monitoring in and around the Swift Creek and Lake Chesdin Reservoirs in Virginia. This has proved useful by (1) helping determine valid reservoir sampling stations, (2) monitoring areas not accessible by land or water, (3) giving the State a viable means of measuring Secchi depth readings in these inaccessible areas, (4) giving an overview of trends in changing sedimentation loadings over a given time period and classifying these waters into various categories, (5) enabling the State to inventory all major lakes and reservoirs and computing their acreage, (6) monitoring land use changes in any specific area, (7) evaluating possible long-term environmental effects of nearby developments, and (8) monitoring and predicting population shifts with possible impact on water quality problems. The main problems in the long-term use of such imagery appear to be cost and lack of consistency due to cloud cover limitations.
Presentation on NNSS environmental compliance work, specifically air quality and radionuclide monitoring in the environment. Presentation to be given at NFO's Tribal Update Meeting April 11, 2023. Presentation is due to DRI on March 28.
Designated as an impaired body of water by both state and federal water quality standards, Hilo Bay, Hawaiʻi is highly susceptible to brown water, a condition where the water becomes murky and is associated with excess levels of bacteria, contaminants, and nutrients. A breakwater in Hilo Bay, which was established to protect Hilo town from tsunamis, interferes with water circulation and prolongs the presence of brown water in the bay. The State of Hawaiʻi issues brown water advisories (BWAs) following flash flood warnings, sewage spills, and other events to indicate a public health concern for those who use Hilo Bay for recreation, cultural purposes, and fishing. Due to the elevated public health risk and ecosystem disturbance that brown water poses to Hilo Bay, we partnered with the Hawaiʻi County Office of Sustainability, Climate, Equity, and Resilience (OSCER) to examine the feasibility of using Earth observations (EO) to monitor water quality in the Hilo Bay region. We leveraged data from Sentinel-2 Multispectral Instrument (MSI), Landsat 8 Operational Land Imager (OLI), Landsat 9 OLI-2, and Aqua and Terra Moderate Resolution Imagine Spectroradiometer (MODIS) instruments to identify and assess spatial and temporal patterns of two main water quality parameters, turbidity and chlorophyll-a, during BWAs. We used the Optical Reef and Coastal Area Assessment (ORCAA) tool in Google Earth Engine to process EO data and generate water quality maps and time series. Our study found that increased turbidity levels can be identified by EO data during BWAs. In addition, our map products indicated the presence of several turbidity plumes along the coast, with the highest concentration of turbidity found within Hilo Bay. While chlorophyll-a levels were relatively flat within our study region during BWAs, we found that regional chlorophyll-a patterns could be derived from MODIS chlorophyll-a data in NASA Worldview. Our study’s multi-sensor approach provided valuable insights for how water quality in the Hilo Bay region can be monitored in the future.
Air quality monitors using low-cost optical PM 2.5 sensors can track the dispersion of wildfire smoke; but quantitative hazard assessment requires a smoke-specific adjustment factor (AF). This study determined AFs for three professional-grade devices and four monitors with low-cost sensors based on measurements inside a well-ventilated lab impacted by the 2018 Camp Fire in California (USA). Using the Thermo TEOM-FDMS as reference, AFs of professional monitors were 0.85 for Grimm mini wide-range aerosol spectrometer, 0.25 for TSI DustTrak, and 0.53 for Thermo pDR1500; AFs for low-cost monitors were 0.59 for AirVisual Pro, 0.48 for PurpleAir Indoor, 0.46 for Air Quality Egg, and 0.60 for eLichens Indoor Air Quality Pro Station. We also compared public data from 53 PurpleAir PA-II monitors to 12 nearby regulatory monitoring stations impacted by Camp Fire smoke and devices near stations impacted by the Carr and Mendocino Complex Fires in California and the Pole Creek Fire in Utah. Camp Fire AFs varied by day and location, with median (interquartile) of 0.48 (0.44–0.53). Adjusted PA-II 4-h average data were generally within ±20% of PM 2.5 reported by the monitoring stations. Adjustment improved the accuracy of Air Quality Index (AQI) hazard level reporting, e.g., from 14% to 84% correct in Sacramento during the Camp Fire.