Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiometric instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The Effect of Incident Light Polarization on Vegetation Bidirectional Reflectance Factor

The Laboratory-based Bidirectional Reflectance Factor (BRF) polarization study of vegetation is presented in this paper. The BRF was measured using a short-arc Xenon lamp/monochromator assembly producing an incoherent, tunable light source with a well-defined spectral bandpass at visible and near-infrared wavelengths of interest at 470 nm and 870 nm and coherent light source at 1.656 microns. All vegetation samples were measured using P and S linearly polarized incident light over a range of incident and scatter angles. By comparing these results, we quantitatively examine how the BRF of the samples depends on the polarization of the incident light. The differences are significant, depend strongly on the incident and scatter angles, and can be as high as 120% at 67 deg incident and 470nm. The global nature of Earth's processes requires consistent long-term calibration of all instruments involved in data retrieval. The BRF defines the reflection characteristics of Earth surface. It provides the reflectance of a target in a specific direction as a function of illumination and viewing geometry. The BRF is a function of wavelength and reflects the structural and optical properties of the surface. Various space and airborne radiometric and imaging remote sensing instruments are used in the remote sensing characterization of vegetation canopies and soils, oceans, or especially large pollution sources. The satellite data is validated through comparison with airborne, ground-based and laboratory-based data in an effort to fully understand the vegetation canopy reflectance, The Sun's light is assumed to be unpolarized at the top of the atmosphere; however it becomes polarized to some degree due to atmospheric effects by the time it reaches the vegetation canopy. Although there are numerous atmospheric correction models, laboratory data is needed for model verification and improvement.

Georgiev, Georgi T.↗

Adjustments to the MODIS Terra Radiometric Calibration and Polarization Sensitivity in the 2010 Reprocessing

The Moderate-Resolution Imaging Spectroradiometer (MODIS) on NASA s Earth Observing System (EOS) satellite Terra provides global coverage of top-of-atmosphere (TOA) radiances that have been successfully used for terrestrial and atmospheric research. The MODIS Terra ocean color products, however, have been compromised by an inadequate radiometric calibration at the short wavelengths. The Ocean Biology Processing Group (OBPG) at NASA has derived radiometric corrections using ocean color products from the SeaWiFS sensor as truth fields. In the R2010.0 reprocessing, these corrections have been applied to the whole mission life span of 10 years. This paper presents the corrections to the radiometric gains and to the instrument polarization sensitivity, demonstrates the improvement to the Terra ocean color products, and discusses issues that need further investigation. Although the global averages of MODIS Terra ocean color products are now in excellent agreement with those of SeaWiFS and MODIS Aqua, and image quality has been significantly improved, the large corrections applied to the radiometric calibration and polarization sensitivity require additional caution when using the data.

Meister, Gerhard↗

Cross‐Instrument Comparison of MapCam and OVIRS on OSIRIS‐REx

Two of the instruments onboard the OSIRIS-REx spacecraft, the MapCam color imager and the OVIRS visible and 20 infrared spectrometer, observed the surface of asteroid (101955) Bennu in partially overlapping wavelengths. 21 Significant scientific advances have been enabled by using data from these two instruments in tandem, but a robust 22 statistical understanding of their relationship is needed for future analyses to cross-compare their data as accurately 23 and sensitively as possible. Here we present a cross-instrument comparison of data acquired by MapCam and 24 OVIRS, including methods and results for all global and site-specific observation campaigns in which both 25 instruments were active. In our analysis, we consider both the absolute radiometric offset and the relative 26 (normalized) variation between the two instruments; we find that both depend strongly on the photometric and 27 instrumental conditions during the observation. The two instruments have a large absolute offset (>15%) due to their 28 independent radiometric calibrations. However, they are very consistent (relative offset as low as 1%) when each 29 instrument’s response is normalized at a single wavelength, particularly at low phase angles where shadows on 30 Bennu’s rough surface are minimized. We recommend using the global datasets acquired at 12:30 pm local solar 31 time for cross-comparisons; data acquired at higher phase angles have larger uncertainties.

D R Golish↗

Calibration of the Microwave Limb Sounder on the Upper Atmosphere Research Satellite

The Microwave Limb Sounder (MLS) is a three-radiometer, passive, limb emission instrument onboard the Upper Atmosphere Research Satellite (UARS). Radiometric, spectral and field-of-view calibrations of the MLS instrument are described in this paper. In-orbit noise performance, gain stability, spectral baseline and dynamic range are described, as well as use of in-flight data for validation and refinement of prelaunch calibrations. Estimated systematic scaling uncertainties (3 sigma) on calibrated limb radiances from prelaunch calibrations are 2.6% in bands 1 through 3, 3.4% in band 4, and 6% in band 5. The observed systematic errors in band 6 are about 15%, consistent with prelaunch calibration uncertainties. Random uncertainties on individual limb radiance measurements are very close to the levels predicted from measured radiometer noise temperature, with negligible contribution from noise and drifts on the regular in-flight gain calibration measurements.

Jarnot, R. F.↗

Continuous Calibration Improvement in Solar Reflective Bands: Landsat 5 Through Landsat 8

Launched in February 2013, the Operational Land Imager (OLI) on-board Landsat 8 continues to perform exceedingly well and provides high science quality data globally. Several design enhancements have been made in the OLI instrument relative to prior Landsat instruments: pushbroom imaging which provides substantially improved Signal-to-Noise Ratio (SNR), spectral bandpasses refinement to avoid atmospheric absorption features, 12 bit data resolution to provide a larger dynamic range that limits the saturation level, a set of well-designed onboard calibrators to monitor the stability of the sensor. Some of these changes such as refinements in spectral bandpasses compared to earlier Landsats and well-designed on-board calibrator have a direct impact on the improved radiometric calibration performance of the instrument from both the stability of the response and the ability to track the changes. The on-board calibrator lamps and diffusers indicate that the instrument drift is generally less than 0.1% per year across the bands. The refined bandpasses of the OLI indicate that temporal uncertainty of better than 0.5% is possible when the instrument is trended over vicarious targets such as Pseudo Invariant Calibration Sites (PICS), a level of precision that was never achieved with the earlier Landsat instruments. The stability measurements indicated by on-board calibrators and PICS agree much better compared to the earlier Landsats, which is very encouraging and bodes well for the future Landsat missions too.

Nischal Mishra↗

Thermistor bolometer scanning radiometer - Applications and flight experience

Scanning radiometers aboard both high-altitude sun-synchronous polar orbit and low altitude equatorial orbit spacecraft have conducted measurements of the earth's long-wave radiation. Attention is presently given to the Earth Radiation Budget Satellite Experiment instruments, which are designed to measure earth radiance with an absolute radiometric error of less than 1 percent. The scanner instruments consists of three broadband radiometer channels employing thermistor bolometers as sensing elements; these radiometers repeatedly scan the earth from limb to limb every 4 sec, generating contiguous pixels on the earth's surface.

Kopia, Leonard P.↗

TPSAS-NF1676L-10737-DND

The Clouds and the Earth's Radiant Energy System (CERES) project provides the community a quality climate TOA and surface fluxes and cloud properties and are key elements in evaluating the ability of climate models to predict both past and future climate states. One important aspect of successful climate monitoring is satellite calibration. The CERES instantaneous broadband calibration radiance stability is 0.1% per year, whereas the accuracy of the longwave (LW) and shortwave (SW) is better than 0.5% and 1% respectively. CERES uses the 3-hourly GEO fluxes and clouds to provide diurnally averaged daily and monthly TOA flux means from the CERES measurements onboard the Terra (10:30 AM local equator crossing time) and Aqua (13:30 PM) sun-synchronous satellites. The GEO radiances are calibrated against MODIS as a reference to provide consistent GEO retrieved cloud properties and derived broadband fluxes. These fluxes are then carefully normalized against the well-calibrated CERES fluxes to ensure climate quality fluxes, free of GEO artifacts. With the upcoming release of Edition3 products, CERES has just recalibrated all the CERES instruments to ensure that both Terra and Aqua fluxes are on the same radiometric scale and the removal of all known instrument trends. CERES will also recalibrate all GEO satellites using the entire GEO time record. CERES employs collocated, coincident ray-matched GEO/MODIS radiances as its primary technique, calibrating GEO radiances beginning in the year 2000. The advantage of the ray-matching technique is that it provides a full dynamic range of radiances to check the linearity of the GEO visible instrument. CERES uses deep convective clouds and invariant desert sites to validate the primary technique. All three methods can assess the stability of the GEO visible instrument. Examples of the CERES GEO calibration techniques and validation efforts will be shown at the conference. Special emphasis will be given to the newly incorporated desert site methodology.

R. Bhatt↗

MODIS TEB Calibration Algorithm Improvements for Future L1B Collection

Terra and Aqua MODIS have provided continuous global observations for scientific applications for more than 20 and 18 years, respectively. The radiometric calibration of the MODIS thermal emissive bands (TEB) is based on a quadratic approximation of the instrument response. The calibration coefficients look-up tables (LUTs) are updated using the response of the MODIS on-board blackbody (BB)with the response background subtracted by space view. The quarterly on-board BB warm-up and cool-down activity temperature ranges from 270 K to 315 K, and the derived offset has a relatively large uncertainty. Electronic cross-talk, an artifact that affects both instrument calibration and Earth view (EV) radiance retrievals, is corrected based on lunar observations. Calibration assessments using EV observations (e.g. ocean, desert, Antarctic Dome Concordia, and deep convective clouds) provide useful information to evaluate the impact of the Terra safe mode (February 2016) and Aqua MODIS formatter reset (January 2018) events on both MODIS instruments. This study focuses on the TEB radiometric calibration algorithm improvements for future collections based on calibration assessments using EV measurements and analytical modeling. Measurement stability and consistency over specific Earth scenes with a wide temperature range, as well as their brightness temperature (BT) dependency, are used for bias estimations in the calibration coefficients. Calibration coefficients are derived and updated after adjusting the current fitting algorithm. Thereafter, using the test LUTs, their impact on the Level 1B (L1B) data for different EV scenes is analyzed.

MODIS↗

Using DSCOVR EPIC as a Transfer Radiometer to Scale Leo Imagers to the Same Calibration Reference

The NASA CERES project provides climate-quality observed TOA and computed surface fluxes to the climate community. The CERES instruments are on board the Terra, Aqua, Suomi-NPP, and NOAA-20 low earth orbiting (LEO) satellites, where they are used in tandem with the MODIS and VIIRS instruments to retrieve cloud properties required for converting CERES radiance observations into fluxes. The CERES project radiometrically scales the MODIS and VIIRS imager visible channel radiances to the Aqua-MODIS reference to retrieve consistent imager cloud properties between sensors. The NPP, NOAA-20, and the future NOAA-21 VIIRS imagers will be in the same sun-synchronous orbit but spaced equally apart, allowing for no simultaneous nadir overpasses (SNO) to inter-calibrate the VIIRS imagers to each other. Currently, the CERES project uses Aqua-MODIS to radiometrically scale between VIIRS imagers. Once the Terra and Aqua satellites start drifting toward the terminator, Aqua can no longer be utilized as the transfer radiometer between VIIRS sensors and there will be no SNOs in common between neither MODIS nor VIIRS imagers. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth. The Earth Polychromatic Imaging Camera (EPIC) instrument on the Earth-facing side of DSCOVR takes images ranging from the UV to the NIR of the sunlit side of the Earth. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that the EPIC instrument response is radiometrically stable. The stability of the EPIC instrument allows it to be used as a transfer radiometer between all MODIS and VIIRS imagers. The study will demonstrate the use of EPIC to radiometrically scale VIIRS and MODIS imagers to the same Aqua-MODIS calibration reference. The EPIC-based NPP and N20-VIIRS scaling factors will be compared with the Aqua-MODIS based NPP and N20-VIIRS scaling factors.

C. O. Haney↗

An intercomparison of longwave measurements by ERBE radiometers on the NOAA-9 and ERBS satellites

Two instrument modules of each satellite on which the Earth Radiation Budget Experiment (ERBE) is orbiting observe components of the earth radiation budget with three different scales of earth view. An intercomparison of longwave measurements by these instruments provides relative information concerning radiometric performance at satellite altitude, techniques of estimating upwelling exitances, and an end-to-end evaluation of the data processing system. Results indicate that the ERBE radiometers are mildly sensitive to varying thermal loads from the spacecraft and/or the earth-space environment. Radiometric variations at the satellite and methods of data interpretation contribute about equally to the uncertainty of radiant exitances from the earth.

House, Frederick B.↗

Calibration for the SAGE III/EOS instruments

The calibration plan for the SAGE III instruments for maintaining instrument performance during the Earth Observing System (EOS) mission lifetime is described. The SAGE III calibration plan consists of detailed preflight and inflight calibration on the instrument performance together with the correlative measurement program to validate the data products from the inverted satellite measurements. Since the measurement technique is primarily solar/lunar occultation, the instrument will be self-calibrating by using the sun as the calibration source during the routine operation of the instrument in flight. The instrument is designed to perform radiometric calibration of throughput, spectral, and spatial response in flight during routine operation. Spectral calibration can be performed in-flight from observation of the solar Fraunhofer lines within the spectral region from 290 to 1030 nm wavelength.

Chu, W. P.↗

Concept of ASTER calibration requirement

The document of ASTER Calibration Requirement specifies the following items related to spectral and radiometric characteristics of the ASTER instrument: (1) characteristics whose knowledge is specified, (2) requirement for knowledge of the characteristics, (3) methodology for characteristics evaluation, and (4) supplementary information and data related with characteristics evaluation. This document is applicable to the document of the ASTER Instrument Specification on Observational Performances, and will be a part of the ASTER Calibration Plan. ASTER Calibration Requirement is scheduled to establish the concept and framework by March 1992 when the 5th Calibration and Data Validation Panel Meeting is held, and to determine details including requirement values and evaluation methodologies by October 1992 around which the Calibration Peer Review may be held. The ASTER Calibration Plan is planned to finish by the same time.

Ono, A.↗

Terra and Aqua MODIS Thermal Emissive Bands Calibration and RVS Stability Assessments Using an In Situ Ocean Target

MODIS, whose openly-public data have been used for over two decades to monitor and address global issues, has 16 Thermal Emissive Bands (TEBs) with central wavelengths that range from 3.7 μm to 14.4 μm, and are calibrated on-orbit using observations from its on-board blackbody. In order to maintain MODIS’ rich, well-calibrated archive of multispectral imagery and data, Earth targets are regularly used to track its long-term stability, as well as the consistency between the two sensors onboard the Terra and Aqua satellites. Moreover, these scenes can be used to compare MODIS Earth view data over the complete scan-angle range and evaluate the on-orbit performance of the TEBs response-versus-scan-angle (RVS) over mission lifetime. This manuscript focuses on evaluating the MODIS TEBs Collection (C6.1) radiometric calibration stability for both instruments using an in situ ocean target as reference (hereafter referred to as in situ sea surface temperature (SST)). Furthermore, it will assess the calibration consistency between the MODIS sensors. Lastly, it will analyze the on-orbit RVS stability for Terra and Aqua MODIS. Only cloud-free, nighttime MODIS TEB retrievals were used for the study. A normalization methodology is applied to standardize the MODIS data to the in situ SST. Additionally, spectral corrections were derived between some of the Terra and Aqua MODIS TEBs by using a combination of the MODIS Atmospheric Profile product and MODerate resolution atmospheric TRANsmission (MODTRAN) simulations. Results indicate that most MODIS TEBs exhibit mission-long trends of ±0.50 K – with Terra band 30 presenting the largest downward drift due to residual electronic cross-talk effects. Moreover, the calibration consistency analysis over a warm ocean target demonstrated that the average Terra-to-Aqua MODIS bias for most bands is well within ±0.50 K (bands 27 and 30 show the largest - electronic crosstalk-related - biases). Lastly, the MODIS TEBs RVS trends display changes of ±0.50 K (except for bands 25 and 27 at the end-of-scan angles) for both instruments. Overall, the MODIS TEBs remain well-calibrated and their RVSs aptly-characterized.

MODIS↗

Extreme Ultraviolet Variability Experiment (EVE) Multiple EUV Grating Spectrographs (MEGS): Radiometric Calibrations and Results

The NASA Solar Dynamics Observatory (SDO), scheduled for launch in early 2010, incorporates a suite of instruments including the Extreme Ultraviolet Variability Experiment (EVE). EVE has multiple instruments including the Multiple Extreme ultraviolet Grating Spectrographs (MEGS) A, B, and P instruments, the Solar Aspect Monitor (SAM), and the Extreme ultraviolet SpectroPhotometer (ESP). The radiometric calibration of EVE, necessary to convert the instrument counts to physical units, was performed at the National Institute of Standards and Technology (NIST) Synchrotron Ultraviolet Radiation Facility (SURF III) located in Gaithersburg, Maryland. This paper presents the results and derived accuracy of this radiometric calibration for the MEGS A, B, P, and SAM instruments, while the calibration of the ESP instrument is addressed by Didkovsky et al. . In addition, solar measurements that were taken on 14 April 2008, during the NASA 36.240 sounding-rocket flight, are shown for the prototype EVE instruments.

Hock, R. A.↗

The Moderate Resolution Imaging Spectrometer-tilt (MODIS-T)

There will be several state-of-the-art spectrometers in operation on the NASA Polar Oribting Platform (NPOP-1) as part of the Earth Observing System. The Moderate Resolution Imaging Spectrometer (MODIS) will consist of two imaging spectroradiometric instruments, one nadir-viewing (MODIS-N) and the other tiltable (MODIS-T) for ocean observation and land bidirectional reflectance studies. The MODIS-T instrument is required to cover the wavelength range of 400 to 880 nm in approximately 15 steps, have less than 2.3 percent instrument-induced polarization, be calibrated to an absolute radiometric accuracy of at least 5 percent over the full dynamic range of the instrument, have a 1.1 kilometer square instantaneous field of view at nadir, and be capable of + or - 50-deg along-track tilt.

Magner, Thomas J.↗

PACE UV-VIS Polarimetric Remote Sensing of Atmosphere-Ocean Systems: Sensitivity to Variations in Brown Carbon

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission, scheduled for launch in 2024, will carry two instruments that measure ultraviolet (UV) radiance emerging from the top of the atmosphere: the Ocean Color Instrument (OCI) and the Spectro-Polarimeter for Planetary Exploration (SPEXone) instrument. OCI will provide single-view, hyperspectral radiometric data, whereas SPEXone will provide multi-angle, multispectral polarimetric data. Together, these instruments will be the most advanced in NASA’s history for the combined observation of ocean color and atmospheric aerosols in the UV, and they will therefore provide unprecedented research opportunities for the ocean color and atmospheric aerosol communities. In particular, UV observations are best suited to retrieve properties of Colored Dissolved Organic Matter (CDOM) in the ocean, and of Brown Carbon (BrC) aerosols in the atmosphere. However, both CDOM and BrC exhibit very similar absorption spectra in the UV and the visible (VIS) spectrum; hence, care must be taken in accurately modeling these spectra for analyses of OCI and SPEXone measurements. In this presentation, we summarize a simple but highly accurate three-parameter model for complex refractive index spectra of BrC in the UV and VIS. We apply this model to simulations of PACE-like total and polarized multiangle radiance in the UV, and demonstrate that the impact of BrC and CDOM variations can be similar in total radiance, but is easy to distinguish in polarized radiance.

PACE↗