Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SOMAFOAM: An OpenFOAM based solver for continuum simulations of low-temperature plasmas

Here, we report the development of SOMAFOAM, a finite volume framework for performing continuum simulations of low-temperature plasmas. The primary goal of this work is to discuss the features of SOMAFOAM along with representative results provided as examples for a range of operating conditions and geometries. This includes plasma and plasma–dielectric systems operating in direct current, radio frequency, and microwave regimes from pressures as low as 100 mTorr to atmospheric pressure. The code has several useful features including the ability to run massively parallel simulations using arbitrary geometries, structured/unstructured meshes, choice of models such as drift–diffusion/full-momentum at runtime, and species-dependent timesteps to name a few. The verification/validation studies presented include comparison with previously published continuum simulations (low-pressure direct current and radio frequency plasma), with experiments (Gaseous Electronics Conference Reference Cell and microwave microplasma ignited in a split ring resonator), and previously published kinetic simulations (low-pressure radio frequency plasma). Other examples provided include a direct current atmospheric pressure microplasma bounded by dielectric sidewalls and a helium–nitrogen plasma ignited using a needle electrode facing a dielectric. The performance of the code is also discussed with serial and distributed memory parallel runs demonstrated up to 512 cores. The design and implementation of the code in a modular object-oriented framework allows for easy extension and seamless coupling with other codes and can be expected to play an important role in both academia and industry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Corrigendum to ‘Evidence for shock heating and constraints on Martian surface temperatures revealed by 40 Ar/ 39 Ar thermochronometry of Martian meteorites’ [Geochim. Cosmochim. Acta (2010) 6900–6920]

Here, the authors regret they have discovered errors in Eq. (3) and in a spreadsheet used to calculate cosmogenic exposure ages shown in Table 1. Eq. (3) is missing a term. The spreadsheet errors concerned an incorrect cell reference and application of Eq. (3). Correction of these errors results in ~15–20% changes to the exposure ages of all samples, minor (generally <0.2%) changes to the radioisotopic ages of some samples (those that entailed a correction for chlorine-derived 38Ar calculated based on the exposure age; see Section 3.3), and statistically insignificant changes to the inferred trapped components identified through isochron analyses. These modifications have no impact on the modeling, discussions, or conclusions in the paper, nor do the changes to radioisotopic ages exceed the 1 sigma uncertainties.

58 GEOSCIENCES↗

The “Fresnel Equations” for Diffuse radiation on Inclined photovoltaic Surfaces (FEDIS)

Here the well-known Fresnel equations solve for the reflection and transmission of light for precise incident angles. The transmission of diffuse radiation incident on a planar or domed surface is often needed for real-world applications. Due to the complexity of the Fresnel equations, the analytical solution of the integration has hitherto been unobtainable over the last centuries. Therefore, this problem was numerically solved by integrating the angular transmittances in space often leading to substantial computing burden and bias in the results. To efficiently estimate the solar energy resource for a glass-covered photovoltaic (PV) module, we derive an analytical solution of diffuse transmission based on the rigorous integration of an alternate form of the Fresnel equations. The approach leads to a simple yet accurate relative transmittance model that reconciles the solar energy sensed by pyranometers and PV panels. With limited and clearly stated approximations, the complex mathematical derivation resulted in an elegant solution. An experiment using 1-year of data at the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) shows that the new model dramatically decreases the disparity between the solar radiation measurements by a Kipp and Zonen CM Pyranometer 22 (CMP22) and an IMT reference cell on a 1-axis tracking system. The solution in this paper can be widely used in scientific and engineering research, development, and applications wherever the Fresnel equations are used.

14 SOLAR ENERGY↗

Thermodynamic analysis of a MEMS based differential scanning calorimeter model

Thin film based differential scanning calorimeter (DSC) was developed and utilized for the study of phase-transition kinetics in protein samples. In this paper, we proposed a MEMS based DSC model. The distance between the sample and reference cell was optimized based on the thermal analysis result. The influence of the response time to the shape of the DSC thermograms and the transition temperature was also studied systematically. Meanwhile, Lumry-Eyring model was used to investigate the relationship between the scanning rate and the transition temperature. The modeling result was verified by the lysozyme denaturation tests. This study provided a pathway for the optimization of MEMS based DSC array and the correction of the DSC thermograms.

47 OTHER INSTRUMENTATION↗

Modelling of a CCP-RF Discharge Used For The Simulation Of Titan's Chemistry

This paper reports the modelling of CCP-RF discharges (13.56 MHz) in pure nitrogen, produced within a cylindrical parallel-plate reactor, similar to a GEC reference cell surrounded by a lateral grounded grid, at 0.1-2 mbar pressures and 10-50 W coupled powers. This study is a first step in simulating Titan's chemistry at laboratory scale, using the PAMPRE experiment. Modelling results are compared with experimental measurements of the average electron density, and the self-bias potential at the polarized electrode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

One-dimensional vertical dust strings in a glass box

The oscillation spectrum of a one-dimensional vertical dust string formed inside a glass box on top of the lower electrode in a gaseous electronics conference (GEC) reference cell was studied. A mechanism for creating a single vertical dust string is described. It is shown that the oscillation amplitudes, resonance frequencies, damping coefficients, and oscillation phases of the dust particles separate into two distinct groups. One group exhibits low damping coefficients, increasing amplitudes, and decreasing resonance frequencies for dust particles closer to the lower electrode. The other group shows high damping coefficients but anomalous resonance frequencies and amplitudes. At low oscillation frequencies, the two groups are also separated by a {pi} phase difference. One possible cause for the difference in behavior between the two groups is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pattern Effects of Soil on Photovoltaic Surfaces

The texture or patterning of soil on PV surfaces may influence light capture at various angles of incidence (AOI). Accumulated soil can be considered a microshading element, which changes with respect to AOI. Laboratory deposition of simulated soil was used to prepare test coupons for simultaneous AOI and soiling loss experiments. A mixed solvent deposition technique was used to consistently deposit patterned test soils onto glass slides. Transmission decreased as soil loading and AOI increased. Dense aggregates significantly decreased transmission. But, highly dispersed particles are less prone to secondary scattering, improving overall light collection. In order to test AOI losses on relevant systems, uniform simulated soil coatings were applied to split reference cells to further examine this effect. Finally, the measured optical transmission and area coverage correlated closely to the observed $I_{{rm SC}}$. Angular losses were significant at angles as low as 25°.

14 SOLAR ENERGY↗

Algorithm for Building a Spectrum for NREL's One-Sun Multi-Source Simulator: Preprint

Historically, the tools used at NREL to compensate for the difference between a reference spectrum and a simulator spectrum have been well-matched reference cells and the application of a calculated spectral mismatch correction factor, M. This paper describes the algorithm for adjusting the spectrum of a 9-channel fiber-optic-based solar simulator with a uniform beam size of 9 cm square at 1-sun.The combination of this algorithm and the One-Sun Multi-Source Simulator (OSMSS) hardware reduces NREL's current vs. voltage measurement time for a typical three-junction device from man-days to man-minutes. These time savings may be significantly greater for devices with more junctions.

14 SOLAR ENERGY↗

Enhanced Photovoltaic Soiling in an Urban Environment

Natural soiling, or the deposition of ambient particulate matter (PM) onto the surface of solar glass, causes losses in PV production around the world. Much work in the PV community has focused on soiling in dusty desert environments. However, PV systems in urban environments are exposed to different contaminants and thus soil differently. We present an analysis of PV soiling in such an urban environment considering the impacts of meteorological parameters. We present 1 year of results from a soiling station in an urban location in Colorado. Bare glass samples were exposed outdoors for 11 days alongside the station; results from microscopy and light transmittance measurements show how moisture and dew affect the morphology and optics of contamination on glass. The coupon results suggest that natural (rain) cleanings may not be sufficient to clean solar panels in urban environments. Ion chromatography of soiling on the reference cell surfaces suggest that dry brush cleanings may not sufficiently clean chemicals deposited on solar panel surfaces in urban environments.

14 SOLAR ENERGY↗

Terrestrial photovoltaic measurements, 2

The following major topics are discussed; (1) Terrestrial solar irradiance; (2) Solar simulation and reference cell calibration; and (3) Cell and array measurement procedures. Numerous related subtopics are also discussed within each major topic area.

Source record↗

Instrument remotely measures wind velocities

Doppler-shift spectrometer makes remote satellite measurements of atmospheric wind velocity and temperature at specified altitudes. As in correlation spectrometer, spectrum of gas in reference cell and spectrum of same gas in atmosphere are correlated both in emission and absorption.

Margolis, J. S.↗

Solar power satellite cost estimate

The solar power configuration costed is the 5 GW silicon solar cell reference system. The subsystems identified by work breakdown structure elements to the lowest level for which cost information was generated. This breakdown divides into five sections: the satellite, construction, transportation, the ground receiving station and maintenance. For each work breakdown structure element, a definition, design description and cost estimate were included. An effort was made to include for each element a reference that more thoroughly describes the element and the method of costing used. All costs are in 1977 dollars.

Harron, R. J.↗

Optogalvanic wavelength calibration for laser monitoring of reactive atmospheric species

Laser-based techniques have been successfully employed for monitoring atmospheric species of importance to stratospheric ozone chemistry or tropospheric air quality control. When spectroscopic methods using tunable lasers are used, a simultaneously recorded reference spectrum is required for wavelength calibration. For stable species this is readily achieved by incorporating into the sensing instrument a reference cell containing the species to be monitored. However, when the species of interest is short-lived, this approach is unsuitable. It is proposed that wavelength calibration for short-lived species may be achieved by generating the species of interest in an electrical or RF discharge and using optogalvanic detection as a simple, sensitive, and reliable means of recording calibration spectra. The wide applicability of this method is emphasized. Ultraviolet, visible, or infrared lasers, either CW or pulsed, may be used in aircraft, balloon, or shuttle experiments for sensing atoms, molecules, radicals, or ions.

Webster, C. R.↗

Correlation spectrometer having high resolution and multiplexing capability

A correlation spectrometer permanently incorporates a reference cell and an electro-optical phase modulator (EOPM) in the light path between a sample cell and a detector. The effect of the EOPM is such that its frequency modulates all of the monochromatic component of the incoherent radiation passing through it. The EOPM is adjusted so that when it is ON all of the energy in the monochromatic components is thrown into sidebands differing from the original frequencies by integral multiples of the modulation frequency with the total amount of energy absorbed from the original radiation remaining constant. When there is no coincidence between the constituents in the two cells, the detector's output is the same when the EOPM is ON and when it is OFF. However, when there is coincidence the detector's output changes when the EOPM is switched between its two states. The change in the detector's output is related to the quantity of the constituents in the sample cell.

Margolis, J. S.↗

Sunlight Simulator for Photovoltaic Testing

Light with normalized spectral irradiance resembling that of airmass 1.5 sunlight striking surface of Earth produced by use of ultraviolet filter to modify output of set of flashlamps used as large-area pulsed solar simulator (LAPSS). Filtered LAPSS light allows more realistic measurements of output of photovoltaic devices when using silicon reference cell having different spectral response characteristic.

Mueller, R. L.↗

Measuring Gases With Laser-Induced Fluorescence

Temperature, density, and pressure at selected point in low-temperature, turbulent gaseous flow measured simultaneously by pulsed laser-induced fluorescence (LIF). Measurements made with spatial and temporal resolution. LIF measurements nonintrusive and constitute first alternative means of measuring turbulent fluctuations in temperature and density that compares with conventional hot-wire-anemometer data. Laser beams focused to small spots in wind tunnel and reference cell induce fluorescence in nitric oxide, small amount s mixed with main gas flow. Fluorescence radiation depends on main-gas temperature, pressure, and density and measured to deduce these quantities.

Mckenzie, Robert L.↗

Electrooptic phase modulation gas correlation spectroscopy - A laboratory demonstration

A new gas-correlation spectroscopy technique is described which uses electrooptic phase modulation (EOPM) of atmospheric emission spectra together with a reference cell to selectively detect radiatively active gases. Laboratory results demonstrate that the EOPM gas-correlation technique is a sensitive approach to species abundance measurements, and support the feasibility of an instrument for measurement of winds in the stratosphere and mesosphere using an EOPM. Through the measurement of wind-induced Doppler shifts in the spectra of atmospheric species, this instrument offers a means of monitoring the wind field in the 20-100 km altitude range from a satellite.

Rider, D. M.↗

AM0 efficiency measurements

Procedures for measuring the air mass zero (AM0) current versus voltage characteristics and calculating the efficiency are discussed. The various factors influencing the determination of the efficiency include the I-V measurement system, reference cell calibration, standard reporting conditions, area measurement, light source characteristics, temperature measurement and control, and the measurement procedures. Each of these sources contributes to the precision index and bias limit which is combined to obtain the total uncertainty in the efficiency. These factors are discussed as well as how to minimize differences in the reported AM0 efficiency of a given PV cell between various laboratories.

Emery, Keith↗