Search NASA⌕ Search

SEARCH · Search NASA

Results for “regression test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SU-F-J-218: Predicting Radiation-Induced Xerostomia by Dosimetrically Accounting for Daily Setup Uncertainty During Head and Neck IMRT

Purpose: To determine if the accumulated parotid dosimetry using planning CT to daily CBCT deformation and dose re-calculation can predict for radiation-induced xerostomia. Methods: To track and dosimetrically account for the effects of anatomical changes on the parotid glands, we propagated physicians’ contours from planning CT to daily CBCT using a deformable registration with iterative CBCT intensity correction. A surface mesh for each OAR was created with the deformation applied to the mesh to obtain the deformed parotid volumes. Daily dose was computed on the deformed CT and accumulated to the last fraction. For both the accumulated and the planned parotid dosimetry, we tested the prediction power of different dosimetric parameters including D90, D50, D10, mean, standard deviation, min/max dose to the combined parotids and patient age to severe xerostomia (NCI-CTCAE grade≥2 at 6 mo follow-up). We also tested the dosimetry to parotid sub-volumes. Three classification algorithms, random tree, support vector machine, and logistic regression were tested to predict severe xerostomia using a leave-one-out validation approach. Results: We tested our prediction model on 35 HN IMRT cases. Parameters from the accumulated dosimetry model demonstrated an 89% accuracy for predicting severe xerostomia. Compared to the planning dosimetry, the accumulated dose consistently demonstrated higher prediction power with all three classification algorithms, including 11%, 5% and 30% higher accuracy, sensitivity and specificity, respectively. Geometric division of the combined parotid glands into superior-inferior regions demonstrated ∼5% increased accuracy than the whole volume. The most influential ranked features include age, mean accumulated dose of the submandibular glands and the accumulated D90 of the superior parotid glands. Conclusion: We demonstrated that the accumulated parotid dosimetry using CT-CBCT registration and dose re-calculation more accurately predicts for severe xerostomia and that the superior portion of the parotid glands may be particularly important in predicting for severe xerostomia. This work was supported in part by NIH/NCI under grant R42CA137886 and in part by Toshiba big data research project funds.

60 APPLIED LIFE SCIENCES↗

Fire tests and analyses of a rail cask-sized calorimeter.

Three large open pool fire experiments involving a calorimeter the size of a spent fuel rail cask were conducted at Sandia National Laboratories Lurance Canyon Burn Site. These experiments were performed to study the heat transfer between a very large fire and a large cask-like object. In all of the tests, the calorimeter was located at the center of a 7.93-meter diameter fuel pan, elevated 1 meter above the fuel pool. The relative pool size and positioning of the calorimeter conformed to the required positioning of a package undergoing certification fire testing. Approximately 2000 gallons of JP-8 aviation fuel were used in each test. The first two tests had relatively light winds and lasted 40 minutes, while the third had stronger winds and consumed the fuel in 25 minutes. Wind speed and direction, calorimeter temperature, fire envelop temperature, vertical gas plume speed, and radiant heat flux near the calorimeter were measured at several locations in all tests. Fuel regression rate data was also acquired. The experimental setup and certain fire characteristics that were observed during the test are described in this paper. Results from three-dimensional fire simulations performed with the Cask Analysis Fire Environment (CAFE) fire code are also presented. Comparisons of the thermal response of the calorimeter as measured in each test to the results obtained from the CAFE simulations are presented and discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-1 Thermocouple Data Analysis

This report documents an effort to analyze measured and simulated data obtained in the Advanced Gas Reactor (AGR) fuel irradiation test program conducted in the INL's Advanced Test Reactor (ATR) to support the Next Generation Nuclear Plant (NGNP) R&D program. The work follows up on a previous study (Pham and Einerson, 2010), in which statistical analysis methods were applied for AGR-1 thermocouple data qualification. The present work exercises the idea that, while recognizing uncertainties inherent in physics and thermal simulations of the AGR-1 test, results of the numerical simulations can be used in combination with the statistical analysis methods to further improve qualification of measured data. Additionally, the combined analysis of measured and simulation data can generate insights about simulation model uncertainty that can be useful for model improvement. This report also describes an experimental control procedure to maintain fuel target temperature in the future AGR tests using regression relationships that include simulation results. The report is organized into four chapters. Chapter 1 introduces the AGR Fuel Development and Qualification program, AGR-1 test configuration and test procedure, overview of AGR-1 measured data, and overview of physics and thermal simulation, including modeling assumptions and uncertainties. A brief summary of statistical analysis methods developed in (Pham and Einerson 2010) for AGR-1 measured data qualification within NGNP Data Management and Analysis System (NDMAS) is also included for completeness. Chapters 2-3 describe and discuss cases, in which the combined use of experimental and simulation data is realized. A set of issues associated with measurement and modeling uncertainties resulted from the combined analysis are identified. This includes demonstration that such a combined analysis led to important insights for reducing uncertainty in presentation of AGR-1 measured data (Chapter 2) and interpretation of simulation results (Chapter 3). The statistics-based simulation-aided experimental control procedure described for the future AGR tests is developed and demonstrated in Chapter 4. The procedure for controlling the target fuel temperature (capsule peak or average) is based on regression functions of thermocouple readings and other relevant parameters and accounting for possible changes in both physical and thermal conditions and in instrument performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lowering post‐construction yield assessment uncertainty through better wind plant power curves

Abstract Many operational analyses of wind power plants require a statistical relationship, which can be called the wind plant power curve, to be developed between wind plant energy production and concurrent atmospheric variables. Currently, a univariate linear regression at monthly resolution is the industry standard for post‐construction yield assessments. Here, we evaluate the benefits in augmenting this conventional approach by testing alternative regressions performed with multiple inputs, at a finer time resolution, and using nonlinear machine‐learning algorithms. We utilize the National Renewable Energy Laboratory's open‐source software package OpenOA to assess wind plant power curves for 10 wind plants. When a univariate generalized additive model at daily or hourly resolution is used, regression uncertainty is reduced, in absolute terms, by up to 1.0 % and 1.2 % (corresponding to a −59 % and −80 % relative change), respectively, compared to a univariate linear regression at monthly resolution; also, a more accurate assessment of the mean long‐term wind plant production is achieved. Additional input variables also reduce the regression uncertainty: when temperature is added as an input to the conventional monthly linear regression, the operational analysis uncertainty connected to regression is reduced, in absolute terms, by up to 0.5 % (−43 % relative change) for wind power plants with strong seasonal variability. Adding input variables to the machine‐learning model at daily resolution can further reduce regression uncertainty, with up to a −10 % relative change. Based on these results, we conclude that a multivariate nonlinear regression at daily or hourly resolution should be recommended for assessing wind plant power curves.

17 WIND ENERGY↗

Sorption and desorption characteristics of a packed bed of clay-CaCl{sub 2} desiccant particles

Desiccants can be used in conjunction with solar energy to provide a viable alternative to traditional air conditioning techniques. A desiccant consisting of clay and calcium chloride was developed and tested using multiple sorption and desorption cycles. During sorption, inlet air temperatures from 23 to 36 C with corresponding relative humidities of 42-66% were tested. Additionally, superficial air velocities from 0.17 to 0.85 m/s were tested. During desorption, inlet air temperatures from 50 to 57 C and superficial air velocities of approximately 0.30 and 0.60 m/s were tested. A regression equation was determined for the mass of water sorbed by the clay-CaCl2 desiccant with a R{sup 2} value of 0.917. The desorption data was regressed to an exponential function and significant k-values were determined. An equation for pressure drop through the desiccant was determined and compared to existing models. The desiccant was found to perform well during the repeated test cycles though small masses of desiccant were lost due to surface disintegration of the desiccant spheres. (author)

14 SOLAR ENERGY↗

Feature Selection and Inferential Procedures for Video Data [Slides]

With the rise of electronic and high-dimensional data, new and innovative feature detection and statistical methods are required to perform accurate and meaningful statistical analysis of these datasets that provide unique statistical challenges. In the area of feature detection, much of the recent feature detection research in the computer vision community has focused on deep learning methods, which require large amounts of labeled training data. However, in many application areas, training data is very limited and often difficult to obtain. We develop methods for fast, unsupervised, precise feature detection for video data based on optical flows, edge detection, and clustering methods. We also use pretrained neural networks and interpretable linear models to extract features using very limited training data. In the area of statistics, while high-dimensional data analysis has been a main focus of recent statistical methodological research, much focus has been on populations of high-dimensional vectors, rather than populations of high-dimensional tensors, which are three-dimensional arrays that can be used to model dependent images, such as images taken of the same person or ripped video frames. Our feature detection method is a non-model-based method that fusses information from dense optical flow, raw image pixels, and frame differences to generate detections. Our hypothesis testing methods are based on the assumption that dependent images are concatenated into a tensor that follows a tensor normal distribution, and from this assumption, we derive likelihood-ratio, score, and regression-based tests for one- and multiple-sample testing problems. Our methods will be illustrated on simulated and real datasets. We conclude this report with comments on the relationship between feature detection and hypothesis testing methods.

97 MATHEMATICS AND COMPUTING↗

Comparative Study of Inguinal Hernia Repair Rates After Radical Prostatectomy or External Beam Radiotherapy

Purpose: We tested the hypothesis that patients treated for localized prostate cancer with radical prostatectomy (RP) have a higher risk of requiring an inguinal hernia (IH) repair than their counterparts treated with external beam radiotherapy (EBRT). Methods and Materials: Within the Quebec Health Plan database, we identified 6,422 men treated with RP and 4,685 men treated with EBRT for localized prostate cancer between 1990 and 2000, in addition to 6,933 control patients who underwent a prostate biopsy. From among that population, we identified patients who underwent a unilateral or bilateral hernia repair after either RP or EBRT. Kaplan-Meier plots showed IH repair-free survival rates. Univariable and multivariable Cox regression models tested the predictors of IH repair after RP or EBRT. Covariates consisted of age, year of surgery, and Charlson Comorbidity Index. Results: IH repair-free survival rates at 1, 2, 5, and 10 years were 96.8, 94.3, 90.5, and 86.2% vs. 98.9, 98.0, 95.4, and 92.2%, respectively, in RP vs. EBRT patients (log-rank test, p < 0.001). IH repair-free survival rates in the biopsy population were 98.3, 97.1, 94.9, and 90.2% at the same four time points. In multivariable Cox regression models, RP predisposed to a 2.3-fold higher risk of IH repair than EBRT (p < 0.001). Besides therapy type, patient age (p < 0.001) represented the only other independent predictor of IH repair. Conclusions: RP predisposes to a higher rate of IH repair relative to EBRT. This observation should be considered at informed consent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-678: Response Calibration Using Electron Depth-Dose Data for MRI-Based 3D Polymer Gel Dosimetry

Purpose: To evaluate a calibration method using the depth-dose data of an electron beam for MRI-based polymer gel dosimetry. Methods: MAGAT was manufactured in-house to fill two 400mL-cylindrical phantoms and nine 22mL-glass vials. Phantom-A was irradiated along the cylinder axis with a 9MeV electron beam of 6 cm x 6 cm field size (FS). Phantom-B was irradiated with a 6MV photon beam of 3 cm x 3 cm FS by a 360-degree arc technique. Eight vials were irradiated in a water-bath to various doses with a 20 cm x 20 cm FS 6MV photon beam. All irradiated phantoms and one un-irradiated vial were scanned with a 3T MRI scanner to obtain the spin-spin relaxation rate (R2) distributions. By comparing the measured R2-to-depth data with the known depth-dose data for Phantom-A, R2-to-dose calibration data were obtained (e-beam method). Another calibration data were obtained from the 9 vials data (9-vial method). We tested two regression equations, i.e., third-order polynomial and tangent functions, and two dose normalization methods, i.e., one-point and two-point methods. Then, these two calibration methods were used to obtain the 3D dose distribution of Phantom-B and evaluated by comparing the measured data with the dose distribution from a treatment planning system. The comparison was made with gamma passing rate (2%/2mm criteria). Results: We did not observe a clear advantage of the e-beam method over the 9-vial method for the 3D dose comparison with the test case. Nevertheless, we found that the e-beam method required a smaller dose scaling for the dose comparison. Furthermore, the tangent function showed better data fitting than the polynomial function with smaller uncertainty of the estimated coefficients. Conclusions: Considering the overall superior performance, we recommend the e-beam method with the tangent function as the regression equation and one-point dose normalization for the MRI-based polymer gel dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Elevation of Plasma TGF-{beta}1 During Radiation Therapy Predicts Radiation-Induced Lung Toxicity in Patients With Non-Small-Cell Lung Cancer: A Combined Analysis From Beijing and Michigan

Purpose: To test whether radiation-induced elevations of transforming growth factor-{beta}1 (TGF-{beta}1) during radiation therapy (RT) correlate with radiation-induced lung toxicity (RILT) in patients with non-small-cell lung cancer (NSCLC) and to evaluate the ability of mean lung dose (MLD) to improve the predictive power. Methods and Materials: Eligible patients included those with Stage I-III NSCLC treated with RT with or without chemotherapy. Platelet-poor plasma was obtained pre-RT and at 4-5 weeks (40-50 Gy) during RT. TGF-{beta}1 was measured using an enzyme-linked immunosorbent assay. The primary endpoint was {>=} Grade 2 RILT. Mann-Whitney U test, logistic regression, and chi-square were used for statistical analysis. Results: A total of 165 patients were enrolled in this study. The median radiation dose was 60 Gy, and the median MLD was 15.3 Gy. Twenty-nine patients (17.6%) experienced RILT. The incidence of RILT was 46.2% in patients with a TGF-{beta}1 ratio > 1 vs. 7.9% in patients with a TGF-{beta}1 ratio {<=} 1 (p < 0.001), and it was 42.9% if MLD > 20 Gy vs. 17.4% if MLD {<=} 20 Gy (p = 0.024). The incidence was 4.3% in patients with a TGF-{beta}1 ratio {<=} 1 and MLD {<=} 20 Gy, 47.4% in those with a TGF-{beta}1 ratio >1 or MLD > 20 Gy, and 66.7% in those with a TGF-{beta}1 ratio >1 and MLD > 20 Gy (p < 0.001). Conclusions: Radiation-induced elevation of plasma TGF-{beta}1 level during RT is predictive of RILT. The combination of TGF- {beta}1 and MLD may help stratify the patients for their risk of RILT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temporal Patterns of Fatigue Predict Pathologic Response in Patients Treated With Preoperative Chemoradiation Therapy for Rectal Cancer

Purpose: To investigate whether symptom burden before and during preoperative chemoradiation therapy (CRT) for rectal cancer predicts for pathologic tumor response. Methods and Materials: Fifty-four patients with T3/T4/N+ rectal cancers were treated on a Phase II trial using preoperative capecitabine and concomitant boost radiotherapy. Symptom burden was prospectively assessed before (baseline) and weekly during CRT by patient self-reported questionnaires, the MD Anderson Symptom Inventory (MDASI), and Brief Fatigue Inventory (BFI). Survival probabilities were estimated using the Kaplan-Meier method. Symptom scores according to tumor downstaging (TDS) were compared using Student's t tests. Logistic regression was used to determine whether symptom burden levels predicted for TDS. Lowess curves were plotted for symptom burden across time. Results: Among 51 patients evaluated for pathologic response, 26 patients (51%) had TDS. Fatigue, pain, and drowsiness were the most common symptoms. All symptoms increased progressively during treatment. Patients with TDS had lower MDASI fatigue scores at baseline and at completion (Week 5) of CRT (p = 0.03 for both) and lower levels of BFI 'usual fatigue' at baseline. Conclusion: Lower levels of fatigue at baseline and completion of CRT were significant predictors of pathologic tumor response gauged by TDS, suggesting that symptom burden may be a surrogate for tumor burden. The relationship between symptom burden and circulating cytokines merits evaluation to characterize the molecular basis of this phenomenon.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benefit of Radiation Boost After Whole-Breast Radiotherapy

Purpose: To determine whether a boost to the tumor bed after breast-conserving surgery (BCS) and radiotherapy (RT) to the whole breast affects local control and disease-free survival. Methods and Materials: A total of 1,138 patients with pT1 to pT2 breast cancer underwent adjuvant RT at the University of Florence. We analyzed only patients with a minimum follow-up of 1 year (range, 1-20 years), with negative surgical margins. The median age of the patient population was 52.0 years (+-7.9 years). The breast cancer relapse incidence probability was estimated by the Kaplan-Meier method, and differences between patient subgroups were compared by the log rank test. Cox regression models were used to evaluate the risk of breast cancer relapse. Results: On univariate survival analysis, boost to the tumor bed reduced breast cancer recurrence (p < 0.0001). Age and tamoxifen also significantly reduced breast cancer relapse (p = 0.01 and p = 0.014, respectively). On multivariate analysis, the boost and the medium age (45-60 years) were found to be inversely related to breast cancer relapse (hazard ratio [HR], 0.27; 95% confidence interval [95% CI], 0.14-0.52, and HR 0.61; 95% CI, 0.37-0.99, respectively). The effect of the boost was more evident in younger patients (HR, 0.15 and 95% CI, 0.03-0.66 for patients <45 years of age; and HR, 0.31 and 95% CI, 0.13-0.71 for patients 45-60 years) on multivariate analyses stratified by age, although it was not a significant predictor in women older than 60 years. Conclusion: Our results suggest that boost to the tumor bed reduces breast cancer relapse and is more effective in younger patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

No Clinically Significant Changes in Pulmonary Function Following Stereotactic Body Radiation Therapy for Early- Stage Peripheral Non-Small Cell Lung Cancer: An Analysis of RTOG 0236

Purpose: To investigate pulmonary function test (PFT) results and arterial blood gas changes (complete PFT) following stereotactic body radiation therapy (SBRT) and to see whether baseline PFT correlates with lung toxicity and overall survival in medically inoperable patients receiving SBRT for early stage, peripheral, non-small cell lung cancer (NSCLC). Methods and Materials: During the 2-year follow-up, PFT data were collected for patients with T1-T2N0M0 peripheral NSCLC who received effectively 18 Gy × 3 in a phase 2 North American multicenter study (Radiation Therapy Oncology Group [RTOG] protocol 0236). Pulmonary toxicity was graded by using the RTOG SBRT pulmonary toxicity scale. Paired Wilcoxon signed rank test, logistic regression model, and Kaplan-Meier method were used for statistical analysis. Results: At 2 years, mean percentage predicted forced expiratory volume in the first second and diffusing capacity for carbon monoxide declines were 5.8% and 6.3%, respectively, with minimal changes in arterial blood gases and no significant decline in oxygen saturation. Baseline PFT was not predictive of any pulmonary toxicity following SBRT. Whole-lung V5 (the percentage of normal lung tissue receiving 5 Gy), V10, V20, and mean dose to the whole lung were almost identical between patients who developed pneumonitis and patients who were pneumonitis-free. Poor baseline PFT did not predict decreased overall survival. Patients with poor baseline PFT as the reason for medical inoperability had higher median and overall survival rates than patients with normal baseline PFT values but with cardiac morbidity. Conclusions: Poor baseline PFT did not appear to predict pulmonary toxicity or decreased overall survival after SBRT in this medically inoperable population. Poor baseline PFT alone should not be used to exclude patients with early stage lung cancer from treatment with SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postmastectomy Radiation Therapy Is Associated With Improved Survival in Node-Positive Male Breast Cancer: A Population Analysis

Purpose: Because of its rarity, there are no randomized trials investigating postmastectomy radiation therapy (PMRT) in male breast cancer. This study retrospectively examines the impact of PMRT in male breast cancer patients in the National Cancer Institute's Surveillance, Epidemiology, and End Results (SEER) database. Methods and Materials: The SEER database 8.3.2 was queried for men ages 20+ with a diagnosis of localized or regional nonmetastatic invasive ductal/lobular carcinoma from 1998 to 2013. Included patients were treated by modified radical mastectomy (MRM), with or without adjuvant external beam radiation. Univariate and multivariate analyses evaluated predictors for PMRT use after MRM. Kaplan-Meier overall survival (OS) curves of the entire cohort and a case-matched cohort were calculated and compared by the log-rank test. Cox regression was used for multivariate survival analyses. Results: A total of 1933 patients were included in the unmatched cohort. There was no difference in 5-year OS between those who received PMRT and those who did not (78% vs 77%, respectively, P=.371); however, in the case-matched analysis, PMRT was associated with improved OS at 5 years (83% vs 54%, P<.001). On subset analysis of the unmatched cohort, PMRT was associated with improved OS in men with 1 to 3 positive nodes (5-year OS 79% vs 72% P=.05) and those with 4+ positive nodes (5-year OS 73% vs 53% P<.001). On multivariate analysis of the unmatched cohort, independent predictors for improved OS were use of PMRT: HR=0.551 (0.412-0.737) and estrogen receptor–positive disease: HR=0.577 (0.339-0.983). Predictors for a survival detriment were higher grade 3/4: HR=1.825 (1.105-3.015), larger tumor T2: HR=1.783 (1.357-2.342), T3/T4: HR=2.683 (1.809-3.978), higher N-stage: N1 HR=1.574 (1.184-2.091), N2/N3: HR=2.328 (1.684-3.218), black race: HR=1.689 (1.222-2.336), and older age 81+: HR=4.164 (1.497-11.582). Conclusions: There may be a survival benefit with the addition of PMRT for male breast cancer with node-positive disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Designing clay-polymer nanocomposite sorbents for water treatment: A review and meta-analysis of the past decade

Clay-polymer nanocomposites (CPNs) have been studied for two decades as sorbents for water pollutants, but their applicability remains limited. Our aim in this review is to present the latest progress in CPN research using a meta-analysis approach and identify key steps necessary to bridge the gap between basic research and CPN application. Based on results extracted from 99 research articles on CPNs and 8 review articles on other widely studies sorbents, CPNs had higher adsorption capacities for several inorganic and organic pollutant classes (including heavy metals, oxyanions, and dyes, n = 308 observations). We applied principal component analysis, analysis of variance, and multiple linear regressions to test how CPN and pollutant properties correlated with Langmuir adsorption model coefficients. While adsorption was, surprisingly, not influenced by mineral properties, it was influenced by CPN fabrication method, polymer functional groups, and pollutant properties. For example, among the pollutant classes, heavy metals had the highest adsorption capacity but the lowest adsorption affinity. Conversely, dyes had high adsorption affinities, as reflected by the linear correlation between adsorption affinity and pollutant molecular weight. Scaling from ‘basic research’ to ‘technological application’ requires testing CPN performance in real water, application in columns, comparison to commercial sorbents, regeneration, and cost evaluation. However, our survey indicates that of the 158 observations, only 20 compared the CPN's performance to that of a commercial sorbent. We anticipate that this review will promote the design of smart and functional CPNs, which can then evolve into an effective water treatment technology.

42 ENGINEERING↗

SU-E-T-30: Absorbed Doses Determined by Texture Analysis of Gafchromic EBT3 Films Using Scanning Electron Microscopy: A Feasibility Study

Purpose: The texture analysis method is useful to estimate structural features of images as color, size, and shape. The study aims to determine a dose-response curve by texture analysis of Gafchromic EBT3 film images using scanning electron microscopy (SEM). Methods: The uncoated Gafchromic EBT3 films were prepared to directly scan over the active surface layer of EBT3 film using SEM. The EBT3 films were exposed at a dose range of 0 to 10 Gy using a 6 MV photon beam. The exposed film samples were SEM-scanned at 100X, 1000X, and 3000X magnifications. The four texture features (Homogeneity, Correlation, Contrast, and Energy) were calculated based on the gray level co-occurrence matrix (GLCM) derived from the SEM images at each dose. To validate a correlation between delivered doses and texture features, an R-squared value in linear regression was tested. Results: The results showed that the Correlation index was more suitable as dose indices than the other three texture features due to higher linearity and sensitivity of the dose response curves. Further the Correlation index of 3000X magnified SEM images with 9 pixel offsets had an R-squared value of 0.964. The differences between the delivered doses and the doses measured by this method were 0.9, 1.2, 0.2, and 0.2 Gy at 5, 10, 15, and 20 Gy, respectively. Conclusion: It seems to be feasible to convert micro-scale structural features of {sub χ}t{sub χχχ}he EBT3 films to absorbed doses using the texture analysis method.

60 APPLIED LIFE SCIENCES↗

Developing and Evaluating Metrics for Demand Flexibility in Buildings: Comparing Simulations and Field Data

Building demand flexibility (DF) has attracted significant attention in recent years among researchers, technology developers and control companies, aggregators, utilities, and many others. There are numerous challenges with today’s electricity systems such as managing peak demand capacity and integrating variable renewables into the grid. Flexible building loads can provide various grid services to help reduce electricity costs, smooth out renewables intermittency and balance supply and demand. Recognizing this, the US DOE is leading the Grid-interactive Efficient Buildings (GEB) initiative which includes research to evaluate the potential, availability and timing of flexible loads. In this paper we present load shed metrics for three building types – medium office, large office and retail store – and compare prototype simulation results with measured data from 12 actual buildings that participated in hot summertime utility demand response (DR) events. The DR strategies included varying zone temperature and reducing light levels. The magnitude of a key DF metric, “demand decrease intensity” (or “shed intensity”) (W/ft2), between the simulation results and field data are similar (14-32% differences) for both mean and median values, though the field data show much larger variation among DR events. The coefficient p-values from linear regression model tests showed that outside air temperature is a significant variable for the whole building shed intensity when the resetting zone temperature strategy is deployed. These findings support the concept of using prototype building simulation to estimate building DF and expanding future simulation research to additional building types and climate zones.

Liu, Jingjing↗