Search NASA⌕ Search

SEARCH · Search NASA

Results for “relative humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Validation of clear-sky fluxes for tropical oceans from the Earth Radiation Budget Experiment

The existence and magnitude of a systematic bias in the clear-sky longwave fluxes from the Earth Radiation Budget Experiment (ERBE) is investigated. The bias is apparently introduced because the ERBE method for scene identification does not account for large zonal gradients in longwave absorption by water vapor. The ERBE fluxes are compared to fluxes calculated with a radiative transfer model from ship radiosonde measurements. The comparison is based upon an analysis of 5 yr of coincident satellite and radiosonde observations for equatorial ocean regions. The differences between the ERBE and model fluxes are examined as functions of sea surface temperature (SST) and relative humidity. The authors use height-mean relative humidity bar-RH as an index of atmospheric moisture. The average offset between and model ERBE fluxes ranges between +2 and +6 W/sq m for SSTs above 295 K, and the gradients with respect to SST are nearly identical. However, the difference between the model and ERBE depends significantly on the tropospheric relative humidity. ERBE fluxes exceed model fluxes for bar-RH above 70%, and the maximum offset of +9 to +12 W/sq m is consistent with previous estimates. There are also indications that the clear-sky fluxes for bar-RH below 25% may be underestimated by about 10-15 W/sq m. Since extreme values of height-mean humidity are relatively infrequent, the net bias introduced in the ERBE monthly mean clear-sky fluxes is generally less than the systematic error in estimates introduced in the ERBE monthly mean clear-sky fluxes is generally less than the systematic error in estimates of the instantaneous fluxes. These findings support earlier work on the coupling between SST and the atmospheric greenhouse effect, in particular the existence of a super greenhouse effect for oceans warmer than 300 K. Recent reports of much larger systematic differences are not supported by this analysis. The results indicate that comparison of general circulation model (GCM) and ERBE clear-sky longwave fluxes will depend explicitly on atmospheric humidity.

Collins, W. D.↗

Hygroscopic Properties of Magnetic Recording Tape

Relative humidity has been recognized as an important environmental factor in many head-tape interface phenomena such as headwear, friction, staining, and tape shed. Accordingly, the relative humidity is usually specified in many applications of tape use, especially when tape recorders are enclosed in hermetically sealed cases. Normally, the relative humidity is believed regulated by humidification of the fill gas to the specification relative humidity. This study demonstrates that the internal relative humidity in a sealed case is completely controlled by the time-dpendence of the hygroscopic properties of the pack of magnetic recording tape. Differences are found in the hygroscopic properties of the same brand of tape, which apparently result from aging, and which may have an effect on the long-term humidity-regulating behavior in a sealed case, and on the occurrence of head-tape interface phenomena from the long-term use of the tape. Results are presented on the basic hygroscopic properties of magnetic tape, its humidity-regulating behavior in a sealed case, and a theoretical commentary on the relative humidity dependence of head-wear by tape, is included.

Cuddihy, E. F.↗

CROCUS Weather Data at Northeastern Illinois University Rooftop

This dataset is from the Department of Energy Office of Science funded project, Community Research on Urban and Climate Science (CROCUS) (https://crocus-urban.org/). Vaisala WXT sensor is an all-in-one weather instrument that provides 6 of the most important weather parameters: barometric pressure, temperature, relative humidity, rainfall, wind speed and direction. Temperature, pressure, relative humidity, and rainfall are sampled at 1 second frequency, while wind speed/direction is measured at ten per second (10Hz) frequency. These measurements are useful for looking at characterizing local weather, identifying unique weather events, and studying local turbulence, especially given the high temporal resolution of the wind measurements.Datasets are stored in the netCDF data format, and we we encourage users to make use the associated toolkits available from Unidata (https://www.unidata.ucar.edu/software/netcdf/), Project Pythia (https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html), and our “Instrument Cookbooks” (https://crocus-urban.github.io/instrument-cookbooks) for more information on how to process the metadata-rich datasets.

54 ENVIRONMENTAL SCIENCES↗

Water Vapor Measurements by Howard University Raman Lidar during the WAVES 2006 Campaign

Retrieval of water vapor mixing ratio using the Howard University Raman Lidar is presented with emphasis on three aspects: i) performance of the lidar against collocated radiosondes and Raman lidar, ii) investigation of the atmospheric state variables when poor agreement between lidar and radiosondes values occurred and iii) a comparison with satellite-based measurements. The measurements were acquired during the Water Vapor Validation Experiment Sondes/Satellites 2006 field campaign. Ensemble averaging of water vapor mixing ratio data from ten night-time comparisons with Vaisala RS92 radiosondes shows on average an agreement within 10 % up to approx. 8 km. A similar analysis of lidar-to-lidar data of over 700 profiles revealed an agreement to within 20 % over the first 7 km (10 % below 4 km). A grid analysis, defined in the temperature - relative humidity space, was developed to characterize the lidar - radiosonde agreement and quantitatively localizes regions of strong and weak correlations as a function of altitude, temperature or relative humidity. Three main regions of weak correlation emerge: i) regions of low relative humidity and low temperature, ii) moderate relative humidity at low temperatures and iii) low relative humidity at moderate temperatures. Comparison of Atmospheric InfraRed Sounder and Tropospheric Emission Sounder satellites retrievals of moisture with that of Howard University Raman Lidar showed a general agreement in the trend but the formers miss a lot of the details in atmospheric structure due to their low resolution. A relative difference of about 20 % is usually found between lidar and satellites measurements.

Adam, M.↗

Back Trajectories during SAIL

This data set contains air mass back trajectories generated during the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign using the Hybrid Single-Particle Lagrangian Integrated Trajectory model (HYSPLIT, Stein et al. 2015, Rolph et al. 2017). For each hour from January 1, 2021 to June 30, 2023, a 96-hour back trajectory was initiated at the SAIL sampling site, starting 100 m above ground level. The calculations used the GDAS meteorological data set with model vertical velocity. The files within this dataset show location and meteorological parameters of the back trajectory analysis. There are 21 columns within each data file. The first 2 columns pertain to back trajectory parameters: the trajectory number (which is always 1) and the meteorological grid number. The next 9 columns pertain to spatiotemporal information: the year, month, day, hour (0-23), and minute of the trajectory, the previous time of the trajectory (in negative hours), and the airmass location (latitude, longitude, and height in m AGL). The rest of the parameters within each file pertains to surface and meteorological characteristics of the airmass: pressure (in hPa), potential temperature (in K), temperature (in K), precipitation rate (in mm/hr), mixing depth (in m), relative humidity (in % relative to liquid water), specific humidity (in g/kg), H2O mixing ratio (in g/kg), underlying terrain height (in meters above sea level), and incoming radiation (in W/m^2).

back trajectory↗

EPCAPE-PT-LANL Measurements: Humidified Cavity Attenuated Phase Shift Spectroscopy

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Humidified Cavity Attenuated Phase Shift Particulate Matter Single Scattering Albedo (H-CAPS-PMSSA, Aerodyne Inc) Data Notes: The scattering truncation correction was not applied to Bsca. The Bext needs no correction. Files: data_10sec_CAPS.csv, data_10min_CAPS.csv Header: - Bext_wet_CAPS_450nm[1/Mm]: Wet aerosol extinction coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Bsca_wet_CAPS_450nm[1/Mm]: Wet aerosol scattering coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Temp_wet_CAPS[K]: Temperature inside the wet CAPS measurement chamber, in Kelvin. - Bext_dry_CAPS_450nm[1/Mm]: Dry aerosol extinction coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Bsca_dry_CAPS_450nm[1/Mm]: Dry aerosol scattering coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Temp_dry_CAPS[K]: Temperature inside the dry CAPS measurement chamber, in Kelvin. - Wet_RH_preCAPS[%]: Relative humidity before entering the wet CAPS, in percent. - Wet_RH_postCAPS[%]: Relative humidity after exiting the wet CAPS, in percent. - Humidifier_RH_CAPS[%]: Relative humidity inside the humidifier used with the CAPS, in percent. - dualCAPS_inlet_RH[%]: Relative humidity at the inlet of the dual (wet/dry) CAPS setup, in percent. - Wet_Temp_preCAPS[C]: Temperature before entering the wet CAPS, in degrees Celsius. - Wet_Temp_postCAPS[C]: Temperature after exiting the wet CAPS, in degrees Celsius. - Humidifier_Temp[C]: Temperature inside the humidifier used with the CAPS, in degrees Celsius. - dualCAPS_inlet_Temp[C]: Temperature at the inlet of the dual (wet/dry) CAPS setup, in degrees Celsius. - Zero_dry_CAPS: 1 is a calibration check for the dry CAPS to ensure zero reading under filter air conditions. - Zero_wet_CAPS: 1 is a calibration check for the wet CAPS to ensure zero reading under filter air conditions. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement.

54 ENVIRONMENTAL SCIENCES↗

Statistical Analysis of Factors Riving Surface Ozone Variability over Continental South Africa

Statistical relationships between surface ozone (O3) concentration, precursor species and meteorological conditions in continental South Africa were examined from data obtained from measurement stations in north-eastern South Africa. Three multivariate statistical methods were applied in the investigation, i.e. multiple linear regression (MLR), principal component analysis (PCA) and –regression (PCR), and generalised additive model (GAM) analysis. The daily maximum 8-h moving average O3 concentrations were considered in these statistical models (dependent variable). MLR models indicated that meteorology and precursor species concentrations are able to explain ~50% of the variability in daily maximum O3 levels. MLR analysis revealed that atmospheric carbon monoxide (CO), temperature and relative humidity were the strongest factors affecting the daily O3 variability. In summer, daily O3 variances were mostly associated with relative humidity, while winter O3 levels were mostly linked to temperature and CO. PCA indicated that CO, temperature and relative humidity were not strongly collinear. GAM also identified CO, temperature and relative humidity as the strongest factors affecting the daily variation of O3. Partial residual plots found that temperature, radiation and nitrogen oxides most likely have a non-linear relationship with O3,while the relationship with relative humidity and CO is probably linear. An inter-comparison between O3 levels modelled with the three statistical models compared to measured O3 concentrations showed that the GAM model offered a slight improvement over the MLR model. These findings emphasise the critical role of regional-scale O3 precursors coupled with meteorological conditions in daily variances of O3 levels in continental South Africa.

multiple linear regression (MLR)↗

Friction and Wear Properties of As-deposited and Carbon Ion-implanted Diamond Films

Recent work on the friction and wear properties of as-deposited and carbon ion-implanted diamond films was reviewed. Diamond films were produced by the microwave plasma chemical vapor deposition (CVD) technique. Diamond films with various grain sizes and surface roughnesses were implanted with carbon ions at 60 ke V ion energy, resulting in a dose of 1.2310(exp 17) carbon ions/cm(exp 2). Various analytical techniques, including Raman spectroscopy, proton recoil analysis, Rutherford backscattering, transmission and scanning electron microscopy, x-ray photoelectron spectroscopy, and x-ray diffraction, were utilized to characterize the diamond films. Sliding friction experiments were conducted with a polished natural diamond pin in contact with diamond films in the three environments: humid air (40 percent relative humidity), dry nitrogen (less than 1 percent relative humidity), and ultrahigh vacuum (10(exp -7) Pa). The CVD diamond films indeed have friction and were properties similar to those of natural diamond in the three environments. The as-deposited, fine-grain diamond films can be effectively used as self-lubricating, wear-resistant coatings that have low coefficients of friction (0.02 to 0.04) and low wear rates (10(exp -7) to 10(exp -8)mm(exp 3)/N-m) in both humid air and dry nitrogen. However, they have high coefficients of friction (1.5 to 1.7) and a high wear rate (10(exp -4)mm(exp 3/N-m) in ultrahigh vacuum. The carbon ion implanation produced a thin surficial layer (less than 0.1 micron thick) of amorphous, nondiamond carbon on the diamond films. In humid air and dry nitrogen, the ion-implanted, fine- and coarse-grain diamond films have a low coefficient of friction (around 0.1) and a low wear rate (10(exp -7)mm(exp 3/N-m). Even in ultrahigh vacuum, the presence of the nondiamond carbon layer reduced the coefficient of friction of fine-grain diamond films to 0.1 or lower and the wear rate to 10(exp -6)mm(exp 3)/N-m. Thus, the carbon ion-implanted, fine-grain diamond films can be effectively used as wear-resistant, self-lubricating coatings not only in air and dry nitrogen, but also in ultrahigh vacuum. The wear mechanism of diamond films is that of small fragments chipping off the surface. The size of wear particles is related to the extent of wear rates.

Miyoshi, Kazuhisa↗

Interannual Variations in Tropical Upper-Tropospheric Humidity: Understanding Tropical Convective and Dynamical Processes

Uncertainty remains as to what extent variability in mid to upper tropospheric moisture, especially over the tropics, behaves as constant relative humidity during interannual climate variations associated with ENSO. Systematic variations in HIRS 6.7 micron and MLS 205 GHz suggest that dry subtropical regions evolving during warm SST events depress relative humidity, but the interpretation of these events is still uncertain. Additional specific concerns have to do with regional signatures of convective processes: How does the origin of dry air in the eastern subtropical N. Pacific differ in ENSO warm versus cold years? The dynamics of Rossby wave forcing by convective heating, subtropical jet stream dynamics, and dynamics driven subsidence all come into play here. How variations in precipitating ice hydrometeors from tropical anvils relate to variations in UTH is also a subject of debate? Do variations in precipitating ice, cloud cover and water vapor behavior show any support for the Iris-hypothesis mechanism? Here we examine historical records of SSM/T-2 data to gain a better physical understanding of the effects of deep convective moisture sources and dynamically-induced vertical circulations on UTH. These high frequency microwave measurements (183.3 GHz) take advantage of far less sensitivity to cloud hydrometeors than the 6.7 micron data to yield a record of upper tropospheric relative humidity. Furthermore, signatures of precipitating ice from these channels facilitate comparisons to TRMM hydrometeors detected by radar. In analyzing these observations, we isolate water vapor and temperature change components that affect brightness temperatures and the inferred relative humidity. Trajectory modeling is also used to understand interannual humidity anomalies in terms of outflow fbm convective regions and history of diabatically-driven sinking which modifies relative humidity.

Robertson, Franklin R.↗

Mesoscale analysis of VAS 6.7 micron image data for several case studies

Several case studies are examined in an attempt to relate Visible infrared spin scan radiometers Atmospheric Sounder (VAS) water vapor channel radiance data to atmospheric moisture. Since the 6.7 micrometer channel detects radiation emitted by atmospheric water vapor from a rather thick layer, a scheme is developed which weighted rawinsonde observations of relative humidity in a similar manner. A comparison of the two fields (weighted relative humidity values from gridded rawinsonde observations and the VAS water vapor image) indicates that even when mesoscale data are used, the technique only presented a smooth representation of the radiance field. This weighting function is dependent on both the temperature and moisture distribution of the atmosphere. Cross sections of relative humidity from the mesoscale rawinsondes are produced which sliced the water vapor imagery in particularly interesting regions (areas of high and low blackbody temperatures). Comparisons are then made between the cross sections and the variations in the VAS radiance data along the cross section line. Bright regions in the water vapor imagery (cold blackbody temperatures) are often associated with thin layers of high relative humidity or thick layers of only moderately moist air. The reverse also applies, i.e., dark regions (warm blackbody temperatures) in the imagery corresponded well with very dry regions in the cross sections.

Jedlovec, G. J.↗

Mesoscale analysis of 6.7 micron image data from the VISSR Atmospheric Sounder (VAS) for several case studies

Several case studies are examined in an attempt to relate Visible infrared spin scan radiometers Atmospheric Sounder (VAS) water vapor channel radiance data to atmospheric moisture. Since the 6.7 micrometer channel detects radiation emitted by atmospheric water vapor from a rather thick layer, a scheme is developed which weighted rawinsonde observations of relative humidity in a similar manner. A comparison of the two fields (weighted relative humidity values from gridded rawinsonde observations and the VAS water vapor image) indicates that even when mesoscale data are used, the technique only presented a smooth representation of the radiance field. This weighting function is dependent on both the temperature and moisture distribution of the atmosphere. Cross sections of relative humidity from the mesoscale rawinsondes are produced which sliced the water vapor imagery in particularly interesting regions (areas of high and low blackbody temperatures). Comparisons are then made between the cross sections and the variations in the VAS radiance data along the cross section line. Bright regions in the water vapor imagery (cold blackbody temperatures) are often associated with thin layers of high relative humidity or thick layers of only moderately moist air. The reverse also applies, i.e., dark regions (warm blackbody temperatures) in the imagery corresponded well with very dry regions in the cross sections.

Jedlovec, G. J.↗

The effect of barrier films and exposure on the aging of vacuum insulation panels with fumed silica cores

Vacuum insulation panels have very low thermal conductivities compared to conventional insulation materials. The reduction of the core pressure significantly lowers gas phase conduction and overall thermal conductivity. As a consequence, increases in gas pressure can significantly increase thermal conductivity of the VIP. In addition, the thermal conductivity of the core is sensitive to moisture content. For vacuum insulation panels with fumed silica cores, work shows that the measured thermal conductivity increases by 0.5 x 10-3 W/mK per mass percent increase in water content [1]. This is significant since the thermal conductivity of vacuum insulation panels with fumed silica cores is in the range of 0.004 W/mK. This work investigates the long-term behavior of vacuum insulation panels comprised of fumed silica cores with polymer (ethylene vinyl alcohol) and metalized (aluminized) barrier films exposed to different exposure conditions: ambient conditions; exterior conditions in a mixed humid climate; and 24oC and 80 percent relative humidity. Results show that the increase in thermal conductivity is more pronounced for vacuum insulation panels made using polymer barrier films compared to the same panel protected by a metalized film. The increase is more pronounced when exposed to high relative humidity, 80 percent. After almost two years exposure, the decrease in thermal conductivity for vacuum insulation panels protected by a metalized barrier films are between 4 and 11 percent depending on exposure condition. The smallest decrease is for ambient conditions where the largest decrease is for exposure to 80 percent relative humidity. Similar behavior was observed for panels protected using polymer films, except the decrease in thermal conductivity was significantly higher, between approximately 20 and 60 percent, in the same order as for panels protected by metalized films. Measurements are ongoing with an attempt to develop a better relationship between these types of tests and vacuum insulation panel service life.

Aldykiewicz Jr, Antonio↗

A Large Ensemble Global Dataset for Climate Impact Assessments

We present a self-consistent, large ensemble, high-resolution global dataset of long-term future climate, which accounts for the uncertainty in climate system response to anthropogenic emissions of greenhouse gases and in geographical patterns of climate change. The dataset is developed by applying an integrated spatial disaggregation (SD) - bias-correction (BC) method to climate projections from the MIT Integrated Global System Model (IGSM). Four emission scenarios are considered that represent energy and environmental policies and commitments of potential future pathways, namely, Reference, Paris Forever, Paris 2 °C and Paris 1.5 °C. The dataset contains nine key meteorological variables on a monthly scale from 2021 to 2100 at a spatial resolution of 0.5°x 0.5°, including precipitation, air temperature (mean, minimum and maximum), near-surface wind speed, shortwave and longwave radiation, specific humidity, and relative humidity. We demonstrate the dataset’s ability to represent climate-change responses across various regions of the globe. This dataset can be used to support regional-scale climate-related impact assessments of risk across different applications that include hydropower, water resources, ecosystem, agriculture, and sustainable development.

54 ENVIRONMENTAL SCIENCES↗

Unconventional desalination: The use of cyclone separators in HDH desalination to achieve zero liquid discharge

Research in water desalination technologies is constantly growing to meet global demands for freshwater. Though acting to meet these demands, the rapid growth and spread of desalination technologies poses environmental issues due to the increasing brine concentrates that are ultimately discharged back to nature. This article presents a cyclone separator to transform a humidification-dehumidification (HDH) cycle to a dual-product cycle to produce freshwater and solid salt crystals for highly saline streams. A desalination cycle equipped with a cyclone separator is used to treat water with 3.5%–81% salinity. The separation efficiency is well above 99% and can produce potable water from hyper saline feed in a once-through process. Further, the cyclone separator performance was tested under different conditions including humidity ratios, relative humidities, and feed stream's salinities. The cyclone separator is self-cleaning and overcomes salt scaling. This behavior is a direct function of the walls' temperature and the carrier air dew point. Self-cleaning capability allows the cyclone separator to treat feed water of extreme salinities (up to 810,000ppm) down to freshwater salinity with zero liquid discharge. The cyclone separator was utilized in a novel HDH desalination technology to treat different salinities. The product was freshwater of salinity <500ppm.

42 ENGINEERING↗

Confocal Raman Microscopy as an In Situ Probe of Volume Change in Hydration-Sensitive Polymer Membranes

An approach is described for measuring hydration-induced volume change within ion conductive polymer membranes and thin films by adapting the technique of confocal Raman microscopy. With careful consideration of factors that affect excitation and scattering within the confocal probe volume region, material swelling and deswelling were estimated from the intensities of polymer matrix spectral features. A high numerical aperture oil-immersion objective was used to achieve tight focusing within samples and the efficient collection of Raman scattered light. The approach is demonstrated for a fluorinated cation-exchange ionomer (Nafion) and the hydrocarbon anion-exchange ionomer Sustainion. Samples were monitored while under a nitrogen atmosphere that was cycled between dry and humid (∼50% relative humidity, RH) states. The volume changes estimated from the Raman spectra were in close agreement with those derived from conventional measurements. The reported work advances understanding needed to adapt confocal Raman microscopy for quantitative in situ and operando studies of ionomers within electrochemical devices, such as polymer electrolyte membrane fuel cells and electrolyzers, and lays a foundation for broader applications in the study of hydration-induced polymer swelling and the associated molecular level water and polymer framework structural changes.

Absorption↗

Evaluating Autoxidation Radical Scavengers and Additives to Enhance Aminopolymer Sorbent Stability

Solid amine sorbents have shown promise in the removal of ultradilute CO 2 from the atmosphere. Despite being a promising candidate material type for this application, these sorbents are prone to degradation during long-term exposure to environmental components such as CO 2 , O 2 , and H 2 O, with amine oxidation being a particularly challenging problem. In this study, we investigate the potency of different radical scavengers and additives in mitigating the degradation of a model poly- (ethylenimine) (PEI)/Al 2 O 3 sorbent under direct air capture (DAC)-relevant conditions. The results reveal that a 4,4′-bis(α,α- dimethylbenzyl)diphenylamine (BDDPA)-incorporated PEI/Al 2 O 3 sorbent showed the most resistance toward oxidative degradation at varying exposure times and BDDPA loadings under CO 2 -free air (21% O 2 /balance N 2 ) at 120 °C. Interestingly, under humid (∼43% relative humidity (RH) at 26 °C) and dry 0.04% CO 2 -air, the BDDPA/PEI/Al 2 O 3 sorbent showed enhanced sorbent stability both at 70 and 120 °C after 4.5 h of exposure. Under humid CO 2 -free air, at 120 °C, the antioxidant performance slightly declined (in comparison to the dry CO 2 -free air condition) but displayed a much higher stability than the pristine sorbent. Overall, the ability of BDDPA to inhibit sorbent degradation under dry and humid, CO 2 -free and CO 2 -containing (0.04%) air at intermediate (70 °C) and elevated (120 °C) temperatures is promising in prolonging sorbent stability and underscores the importance of performing accelerated oxidation studies in the presence of all species that are expected to be present in DAC processes to identify suitable stabilization treatments for sorbent materials.

36 MATERIALS SCIENCE↗

Can N95 Respirators Be Reused after Disinfection? How Many Times?

The coronavirus disease 2019 (COVID-19) pandemic has led to a major shortage of N95 respirators, which are essential for protecting healthcare professionals and the general public who may come into contact with the virus. Thus, it is essential to determine how we can reuse respirators and other personal protective equipment in these urgent times. We investigated multiple commonly used disinfection schemes on media with particle filtration efficiency of 95%. Heating was recently found to inactivate the virus in solution within 5 min at 70 °C and is among the most scalable, user-friendly methods for viral disinfection. We found that heat (≤85 °C) under various humidities (≤100% relative humidity, RH) was the most promising, nondestructive method for the preservation of filtration properties in meltblown fabrics as well as N95-grade respirators. At 85 °C, 30% RH, we were able to perform 50 cycles of heat treatment without significant changes in the filtration efficiency. At low humidity or dry conditions, temperatures up to 100 °C were not found to alter the filtration efficiency significantly within 20 cycles of treatment. Ultraviolet (UV) irradiation was a secondary choice, which was able to withstand 10 cycles of treatment and showed small degradation by 20 cycles. However, UV can potentially impact the material strength and subsequent sealing of respirators. Finally, treatments involving liquids and vapors require caution, as steam, alcohol, and household bleach all may lead to degradation of the filtration efficiency, leaving the user vulnerable to the viral aerosols.

60 APPLIED LIFE SCIENCES↗

Navigating the Noise: Bringing Clarity to ML Parameterization Design With O $\boldsymbol{\mathcal{O}}$(100) Ensembles

Abstract Machine‐learning (ML) parameterizations of subgrid processes (here of turbulence, convection, and radiation) may one day replace conventional parameterizations by emulating high‐resolution physics without the cost of explicit simulation. However, uncertainty about the relationship between offline and online performance (i.e., when integrated with a large‐scale general circulation model) hinders their development. Much of this uncertainty stems from limited sampling of the noisy, emergent effects of upstream ML design decisions on downstream online hybrid simulation. Our work rectifies the sampling issue via the construction of a semi‐automated, end‐to‐end pipeline for size ensembles of hybrid simulations, revealing important nuances in how systematic reductions in offline error manifest in changes to online error and online stability. For example, removing dropout and switching from a Mean Squared Error to a Mean Absolute Error loss both reduce offline error, but they have opposite effects on online error and online stability. Other design decisions, like incorporating memory, converting moisture input from specific humidity to relative humidity, using batch normalization, and training on multiple climates do not come with any such compromises. Finally, we show that ensemble sizes of may be necessary to reliably detect causally relevant differences online. By enabling rapid online experimentation at scale, we can empirically settle debates regarding subgrid ML parameterization design that would have otherwise remained unresolved in the noise.

Lin, Jerry [Department of Earth System Sciences Un↗