Search NASA⌕ Search

SEARCH · Search NASA

Results for “relativistic electrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Electro-optic sampling beam position monitor for relativistic electron beams

Here, an electro-optic sampling beam position monitor for installation at the SLAC National Accelerator Laboratory FACET-II facility is described. Simulations of the detector signal were performed using realistic electron beam current profiles, demonstrating that this single-shot, non-destructive, compact detector is capable of resolving the relative transverse offset and longitudinal separation of an ultra-relativistic, two-bunch electron beam to order 1 μm and 10 fs, respectively. A design study was performed to optimize the detector’s response to the ultra-relativistic two-bunch electron beam utilized in plasma wakefield accelerator experiments. In addition, the expected sensitivity to beam tilt is studied for typical electron beams used in free electron lasers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulation of a Rapid Dropout Event for Highly Relativistic Electrons with the RBE Model

A flux dropout is a sudden and sizable decrease in the energetic electron population of the outer radiation belt on the time scale of a few hours. We simulated a flux dropout of highly relativistic 2.5 MeV electrons using the Radiation Belt Environment model, incorporating the pitch angle diffusion coefficients caused by electromagnetic ion cyclotron (EMIC) waves for the geomagnetic storm events of 23-26 October 2002. This simulation showed a remarkable decrease in the 2.5 MeV electron flux during main phase of the storm, compared to those without EMIC waves. This decrease was independent of magnetopause shadowing or drift loss to the magnetopause. We suggest that the flux decrease was likely to be primarily due to pitch angle scattering to the loss cone by EMIC waves. Furthermore, the 2.5 MeV electron flux calculated with EMIC waves correspond very well with that observed from Solar Anomalous and Magnetospheric Particle EXplorer spacecraft. EMIC wave scattering is therefore likely one of the key mechanisms to understand flux dropouts. We modeled EMIC wave intensities by the Kp index. However, the calculated dropout is a several hours earlier than the observed one. We propose that Kp is not the best parameter to predict EMIC waves.

Kang, S-B.↗

Mesospheric Odd Nitrogen Enhancements During Relativistic Electron Precipitation Events

The behavior of mesospheric odd nitrogen species during and following relativistic and diffuse auroral precipitation events is simulated, Below 75 km nitric oxide is enhanced in proportion to the ion pair production function associated with the electron precipitation and the length of the event. Nitrogen dioxide and nitric acid are also enhanced. At 65 km the percentage of odd nitrogen for N is 0.1%, HNO3 is 1.6%, NO2 is 15%, and NO is 83.3%. Between 75 and 85 km NO is depleted during particle events due to the faster destruction of NO by N relative to the production of NO by N reacting with O2. Recovery of NO depends on transport from the lower thermosphere, where NO is produced in abundant amounts during particle events.

Aikin, A. C.↗

Gyroharmonic maser instability for weakly relativistic electrons with a loss-cone distribution

The weakly relativisitic dielectric tensor for a system of electrons comprised of cold and energetic populations, embedded in a neutralizing background, is reformulated in terms of an infinite series representation in powers of lamba = alpha ck(perpendicular)/omega (c), where alpha-squared is a parameter proportional to the average thermal energy of the energetic electrons, k(perpendicular) is the perpendicular component of the wave vector k, and omega (c) is the electron gyrofrequency. The energetic electrons are assumed to have a loss-cone feature in the perpendicular momentum space. The present formalism can be used in the problem of cyclotron maser as well as more general gyroharmonic maser (i.e., multiharmonics) emissions resulting from weakly relativistic loss-cone electrons. This is because, unlike the previous theories in which certain approximations such as the single-harmonic approximations are made, the present formalism retains contributions from the entire harmonics.

Yoon, Peter H.↗

Self-Consistent Relativistic Electron Scattering using the Sherlock Scattering Model for X-ray Diagnostics

We present on a new, self-consistent, arbitrary-temperature Romberg integration scheme for modeling electron scattering in materials in a LANL Lagrangian Shock Hydro (LSH) code. Electron beam-target interactions are fundamental to a wide range of scientific and technological applications. When high-energy electron beams hit their target, they may scatter, deposit energy, or ionize the source. These processes govern the behavior and outcomes in nanotechnology manufacturing, electron microscopy, and modern X-ray diagnostics. Simulating these interactions is essential for interpreting experimental results, predicting material responses, and designing efficient tools and experiments. At Los Alamos, this is done using a LSH code, which is a multi-dimension, multi-material, massively parallel, multi-physics code used to simulate applications from asteroid impacts to electron beam interactions. By effectively and efficiently modeling the way that electrons scatter from the beam we can bolster these simulations and more accurately predict experimental outcomes. The model currently implemented in the LSH of interest is based on work by Papp and does not self-consistently preserve momentum in the slightly relativistic regime; here we adopt a model proposed by Braams and Karney and implement a Romberg integration scheme to compute the diffusion tensor. In this paper we will provide background on the Braams-Karney diffusion tensor as well as the Romberg integration scheme we employed to numerically solve for it. We will show that our integration scheme is accurate in solving for the set of scalar potentials used to re-express the diffusion tensor in differential form, and in solving for the diffusion coefficients in the larger LSH code. By using this diffusion tensor rather than the existing Papp one, and numerically integrating it with a Romberg method, we produce much more accurate, self-consistent results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pushing the limits of the periodic table — A review on atomic relativistic electronic structure theory and calculations for the superheavy elements

We review the progress in atomic structure theory with a focus on superheavy elements and their predicted ground state configurations important for an element’s placement in the periodic table. To understand the electronic structure and correlations in the regime of large atomic numbers, it is essential to correctly solve the Dirac equation in strong Coulomb fields, and to take into account quantum electrodynamic effects. We specifically focus on the fundamental difficulties encountered when dealing with the many-particle Dirac equation. We further discuss the possibility for future many-electron atomic structure calculations going beyond the critical nuclear charge $Z_{crit}≈170$, where levels such as the $1s$ shell dive into the negative energy continuum ($E_{nκ} < –m_{e}c^2$). The nature of the resulting Gamow states within a rigged Hilbert space formalism is highlighted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Steering an intense relativistic electron beam in a linear induction accelerator

The best electron beam transport through a linear induction accelerator (LIA) is achieved when the beam is well centered on the magnetic axis of the focusing solenoids. Since the beam may be injected offset from, or at an angle to, the centerline, dipole magnets are usually provided as a means to steer the beam and center it. Steering may be accomplished by trial and error, but this is very time consuming, especially for accelerators with a low repetition rate for beam position measurements and dipole adjustments. With this in mind, this article presents a steering method requiring a minimal number of measurements and adjustments to position the beam at any desired location, including positioning on the centerline.

47 OTHER INSTRUMENTATION↗

The effects of pre-plasma scale length on the relativistic electron beam directionality

The effects of pre-plasmas on the electron beam directionality was experimentally and numerically investigated. Single material and layered targets made of Ti and/or CH were used to simultaneously measure high-energy (≥3 MeV) electrons along two directions, pre-pulse energy and pre-plasma density. The electron directionality is quantified by using a new parameter, the electron energy ratio of the total kinetic energies along the two directions. Measurements and radiation–hydrodynamic (RH) simulations show that a large (≥3.5 μm) plasma scale length at the critical surface enhances electrons along the laser axis, and such pre-plasma conditions could only be achieved with the CH targets. Particle-in-cell simulations were performed on the RH generated pre-plasmas from Ti and CH targets, and the results show that the CH target provided conditions for higher forward momentum gains by electrons. First, the CH target allowed longer distances for electrons to interact with laser. Second, the intense laser pulse modified the critical surface, but the resulting surface differed. The CH target resulted in a smooth surface where a retro-reflection was observed while the Ti target resulted in a rippled surface that scattered the reflected light. As results, the CH electrons gained higher forward momentum via a direct-laser-acceleration in the counter propagating laser fields. So the results presented in this article show a way of controlling the high-energy electron directionality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Focusing of relativistic electron beams with permanent magnetic solenoid

Achieving strong focusing of MeV electron beams is a critical requirement for advanced beam applications such as compact laboratory x-ray sources, high gradient accelerators, and ultrafast electron scattering instrumentation. To address these needs, a compact radially magnetized permanent magnetic solenoid (PMS) has been designed, fabricated, and tested. The solenoid provides a compact and inexpensive solution for delivering high axial magnetic fields (1 T) to focus MeV electron beams. Field characterization of the solenoid demonstrates good agreement with analytical models, validating the PMS design. The electron beam test employs a high-brightness photoinjector to study the focusing properties of the PMS. The results indicate a focal length of less than 10 cm and a significant reduction in beam size with small spherical aberrations. Two application cases are evaluated: angular magnification in ultrafast electron diffraction setups and strong focusing for Compton scattering or other microfocus uses.

Electron diffraction↗

Nonparaxial propagation of an intense relativistic electron beam through dense media

An envelope equation is used to explore the propagation of a focused electron beam through dense conductive media like partially ionized high-pressure gas, metal vapor plumes from beam-target interactions, or low-density solid-phase targets. Envelope equations have been a most useful tool for predicting experimental results of beam propagation in gas, and they are refined for the general problem of propagation through a dense medium. The envelope equation is modified to account for the large beam divergence resulting from multiple scattering. The envelope code results are in qualitative agreement with published experimental data. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗