Search NASA⌕ Search

SEARCH · Search NASA

Results for “rotating mirrors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Design, Fabrication, Optical Testing, and Performance of Diamond Machined Aspheric Mirrors for Ground-Based Near-IR Astronomy

Challenges in fabrication and testing have historically limited the choice of surfaces available for the design of reflective optical instruments. Spherical and conic mirrors are common, but, for future science instruments, more degrees of freedom are necessary to meet challenging performance and packaging requirements. These instruments will be composed of unusual aspheres located far off-axis with large spherical departure, and some designs will require asymmetric surface profiles. In particular, single-surface astigmatism correction in spectrographs necessitates a toroidal surface, which lacks an axis of rotational symmetry. We describe the design, fabrication, optical testing, and performance of three rotationally symmetric, off-axis, aspheric mirrors and one toroidal, off-axis, biconic camera mirror on aluminum substrates for the Infrared Multi-Object Spectrograph (IRMOS) instrument. IRMOS is a facility instrument for the Kitt Peak National Observatory's Mayall Telescope (3.8 m) and an engineering prototype for a possible design of the Next Generation Space Telescope/Multi-Object Spectrograph. The symmetric mirrors range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. They are various off-axis, convex and concave, prolate and oblate ellipsoids. The concave biconic mirror has a 94x76 mm aperture, Rx=377 mm, kx=0.0778, Ry=407 mm, and ky=0.1265 and is decentered. by -2 mm in x and 227 mm in y. The mirrors have an aspect ratio of approximately 4:1. The surface error fabrication tolerances are less than 63.3 nm RMS figure error and less than 10 nm RMS microroughness. The mirrors are attached to the instrument bench via a semi-kinematic, integral flexure mount. We describe mirror design, diamond machining, the results of figure testing using computer-generated holograms, and imaging and scattered light modeling and performance.

Ohl, Raymond G.↗

A 2D chiral microcavity based on apparent circular dichroism

Abstract Engineering asymmetric transmission between left-handed and right-handed circularly polarized light in planar Fabry–Pérot (FP) microcavities would enable a variety of chiral light-matter phenomena, with applications in spintronics, polaritonics, and chiral lasing. Such symmetry breaking, however, generally requires Faraday rotators or nanofabricated polarization-preserving mirrors. We present a simple solution requiring no nanofabrication to induce asymmetric transmission in FP microcavities, preserving low mode volumes by embedding organic thin films exhibiting apparent circular dichroism (ACD); an optical phenomenon based on 2D chirality. Importantly, ACD interactions are opposite for counter-propagating light. Consequently, we demonstrated asymmetric transmission of cavity modes over an order of magnitude larger than that of the isolated thin film. Through circular dichroism spectroscopy, Mueller matrix ellipsometry, and simulation using theoretical scattering matrix methods, we characterize the spatial, spectral, and angular chiroptical responses of this 2D chiral microcavity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Survey of ultraviolet shuttle glow

The University of Colorado Get Away Special (GAS) project utilizes the efforts of its students to place experiments on the shuttle. The objective of one experiment, the shuttle glow study, is to conduct a general survey of emissions in the ultraviolet near vehicle surfaces. An approximate wavelength range of 1900 to 3000 A will be scanned to observe predominant features. Special emphasis will be placed on studying the band structure of NO near 2000 A and the Mg+ line at 2800 A. The spectrometer, of Ebert-Faste 1/8-meter design, will perform the experiment during spacecraft night. It will be oriented such that the optical axis points to the cargo bay zenith. In order to direct the field-of-view of the instrument onto the shuttle vertical stabilizer (tail), a mirror assembly is employed. The mirror system has been designed to rotate through 7.5 degrees of arc using 10 positions resulting in a spatial resolution of 30 x 3 cm, with the larger dimension corresponding to the horizontal direction. Such a configuration can be attained from the forwardmost position in the cargo bay. Each spatial position will be subjected to a full spectral scan with a resolution on the order of 10 A.

Spear, K. A.↗

Rotary encoding device

A device for position encoding of a rotating shaft in which a polygonal mirror having a number of facets is mounted to the shaft and a light beam is directed towards the facets is presented. The facets of the polygonal mirror reflect the light beam such that a light spot is created on a linear array detector. An analog-to-digital converter is connected to the linear array detector for reading the position of the spot on the linear array detector. A microprocessor with memory is connected to the analog-to-digital converter to hold and manipulate the data provided by the analog-to-digital converter on the position of the spot and to compute the position of the shaft based upon the data from the analog-to-digital converter.

Leviton, Douglas B.↗

A widely adaptable habitat construction system utilizing space resources

This study suggests that the cost of providing accommodations for various manned activities in space may be reduced by the extensive use of resources that are commonly found throughout the solar system. Several concepts are proposed for converting these resources into simple products with many uses. Concrete is already being considered as a possible moonbase material. Manufacturing equipment should be as small and simple as possible, which leads to the idea of molding it into miniature modules that can be produced and assembled in large numbers to create any conceivable shape. Automated equipment could build up complex structures by laying down layer after layer in a process resembling stereolithography. These tiny concrete blocks handle compression loads and provide a barrier to harmful radiation. They are joined by a web of tension members that could be made of wire or fiber-reinforced plastic. The finished structure becomes air-tight with the addition of a flexible liner. Wire can be made from the iron modules found in lunar soil. In addition to its structural role, a relatively simple apparatus can bend and weld it into countless products like chairs and shelving that would otherwise need to be supplied from Earth. Wire woven into a loose blanket could be an effective micrometeoroid shield, tiny wire compression beams could be assembled into larger beams which in turn form larger beams to create very large space-frame structures. A technology developed with lunar materials could be applied to the moons of Mars or the asteroids. To illustrate its usefulness several designs for free-flying habitats are presented. They begin with a minimal self-contained living unit called the Cubicle. It may be multiplied into clusters called Condos. These are shown in a rotating tether configuration that provides a substitute for gravity. The miniature block proposal is compared with an alternate design based on larger triangular components and a tetrahedral geometry. The overall concept may be expanded to envision city-sized self-sufficient environments where humans could confortably live their entire lives. One such proposal is the Hive. It is configured around a unique sunlight collection system that could provide all its energy needs and that could be scaled up to compensate for the reduced solar intensity at greater distances from the sun. Its outer perimeter consists of a cylindrical section mated to two conical end walls that taper inwards toward a small aperture at the center of rotation. Light collected by two huge mirrors of unusual design enters the aperture and is redirected to the inside of the cylinder. The conical end walls are shielded from direct sunlight and are designed to radiate heat into space. They are lined with air ducts that passively recirculate the atmosphere while extracting moisture by condensation. Although there is no immediate demand for spacecraft on this scale, their consideration can influence even the earliest stages of the development process.

Wykes, Harry B.↗

A Scanning Hartmann Focus Test for the EUVI Telescopes aboard STEREO

The Solar TErrestrial RElations Observatory (STEREO), the third mission in NASA's Solar Terrestrial Probes program, was launched in 2006 on a two year mission to study solar phenomena. STEREO consists of two nearly identical satellites, each carrying an Extreme Ultraviolet Imager (EUVI) telescope as part of the Sun Earth Connection Coronal and Heliospheric Investigation instrument suite. EUVI is a normal incidence, 98mm diameter, Ritchey-Chretien telescope designed to obtain wide field of view images of the Sun at short wavelengths (17.1-30.4nm) using a CCD detector. The telescope entrance aperture is divided into four quadrants by a mask near the secondary mirror spider veins. A mechanism that rotates another mask allows only one of these sub-apertures to accept light over an exposure. The EUVI contains no focus mechanism. Mechanical models predict a difference in telescope focus between ambient integration conditions and on-orbit operation. We describe an independent check of the ambient, ultraviolet, absolute focus setting of the EUVI telescopes after they were integrated with their respective spacecraft. A scanning Hartmann-like test design resulted from constraints implied by the EUVI aperture select mechanism. This inexpensive test was simultaneously coordinated with other NASA integration and test activities in a high-vibration, clean room environment. The total focus test error was required to be better than +/-0.05 mm. We describe the alignment and test procedure, sources of statistical and systematic error, and then the focus determination results using various algorithms. The results are consistent with other tests of focus alignment and indicate that the EUVI telescopes meet the ambient focus offset requirements. STEREO is functioning well on-orbit and the EUVI telescopes meet their on-orbit image quality requirements.

Ohl, Ray↗

Rotary encoding device with polygonal reflector and centroid detection

A device for positioning encoding of a rotating shaft in which a polygonal mirror having a number of facets is mounted to the shaft and a light beam is directed towards the facets. The facets of the polygonal mirror reflect the light beam such that a light spot is created on a linear array detector. An analog-to-digital converter is connected to the linear array detector for reading the position of the spot on the spots on the linear array detector. A microprocessor with memory is connected to the analog-to-digital converter to hold and manipulate the data provided by the analog-to-digital converter on the position of the spot and to compute the position of the shaft based upon the data from the analog-to-digital converter.

Leviton, Douglas B.↗

Characterizing the Hertz-VPM Polarimeter

We present preliminary results from engineering tests conducted at Northwestern U. and the Submillimeter Telescope Observatory (SMTO) on Mt. Graham, AZ. The VPM provides a new method for modulating incoming polarization signals, using small linear translations instead of rotational motion. Our dual grid-mirror design has several advantages over the currently favored technology, the half-wave plate. The VPM appears to successfully modulate submillimeter polarization, with high efficiencies and low instrumental polarization. We briefly discuss feasibility of use for air- and space-born applications.

Krejny↗

Modification and Development of a Control Mechanism for the Scanning Microwave Limb Sounder

The scanning microwave limb sounder (SMLS) is the latest instrument to probe the Earth's atmosphere to come out of the Microwave Limb Sounder (MLS) team. Once deployed to the upper stratosphere, it will use microwave detection to measure geo-atmospheric variables such as temperature, pressure, and chemical composition. In addition to previous missions that used vertical limb scans to observe altitudinal variations, the SMLS will rotate laterally allowing it to establish two-dimensional variable dependencies with a single run. A program was originated by a previous intern that will automatically control the movement of the two rotational axes along with a switching mirror and chopper once the instrument is in flight. However, it lacked the code essential to control system's ability to function fully and reliably. By modifying and rewriting parts of the code I sought to have a finished ready-for-flight control system that would be easy to navigate. Three of the major alterations I made including instituting a gyroscope, implementing a restart button, and instigating the automatic creation of a file log with each run to record the position and orientation of the SMLS.

Scanning Microwave Limb Sounder (SMLS)↗

Dual-Telescope Multi-Channel Thermal-Infrared Radiometer for Outer Planet Fly-By Missions

The design of a versatile dual-telescope thermal-infrared radiometer spanning the spectral wavelength range 8-200 microns, in five spectral pass bands, for outer planet fly-by missions is described. The dual- telescope design switches between a narrow-field-of-view and a wide-field-of-view to provide optimal spatial resolution images within a range of spacecraft encounters to the target. The switchable dual-field- of-view system uses an optical configuration based on the axial rotation of a source-select mirror along the optical axis. The optical design, spectral performance, radiometric accuracy, and retrieval estimates of the instrument are discussed. This is followed by an assessment of the surface coverage performance at various spatial resolutions by using the planned NASA Europa Mission 13-F7 fly-by trajectories as a case study.

Aslam, Shahid↗

Second-order nonlinear optical and linear ultraviolet-visible absorption properties of the type-II multiferroic candidates RbFe( A O 4 ) 2 ( A = Mo, Se, S)

Motivated by the search for type-II multiferroics, in this work, we present a comprehensive optical study of a complex oxide family of type-II multiferroic candidates: RbFe(MoO 4 ) 2 , RbFe(SeO 4 ) 2 , and RbFe(SO 4 ) 2 .We employ rotationalanisotropy second harmonic generation spectroscopy (RA SHG), a technique sensitive to point symmetries, to address discrepancies in literature-assigned point/space groups and to identify the correct crystal structures. At room temperature we find that our RA SHG patterns rotate away from the crystal axes in RbFe(AO 4 ) 2 ( A = Se, S), which identifies the lack of mirror symmetry and in-plane two-fold rotational symmetry. Also, the SHG efficiency of RbFe(SeO 4 ) 2 is two orders of magnitude stronger than RbFe(AO 4 )2 ( A = Mo, S), which suggests broken inversion symmetry. Additionally, we present temperature-dependent linear optical characterizations near the band edge of this family of materials using ultraviolet-visible absorption spectroscopy. Included is experimental evidence of the band gap energy and band gap transition type for this family. Subband gap absorption is also presented, which reveals prominent optical transitions, some with an unusual central energy temperature dependence. Furthermore, we find that by substituting the A site in RbFe(AO 4 ) 2 ( A = Mo, Se, S), the aforementioned transitions are spectrally tunable. Finally, we discuss the potential origin and impact of these tunable transitions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ballooning stability of anisotropic, rotating plasmas

The linearized equation of motion is given in a Lagrangian representation for a rotating plasma with anisotropic pressure. A WKB theory is developed for large-n ballooning modes in an axisymmetric configuration with field-aligned and rigid toroidal flows. In the presence of field-aligned flows, it is shown that a resonance occurs which is strongly suggestive of a generalized mirror instability. In the presence of toroidal rotation, a possible stabilizing effect is identified for P(normal) greater than P(parallel). Finally, as a special case of the theory, the necessary and sufficient conditions for stability in a static, anisotropic plasma are obtained.

Wang, X.-H.↗

Multispectral glancing incidence X-ray telescope

A multispectral glancing incidence X-ray telescope is illustrated capable of broadband, high-resolution imaging of solar and stellar X-ray and extreme ultraviolet radiation sources which includes a primary optical system preferably of the Wolter I type having a primary mirror system (20, 22). The primary optical system further includes an optical axis (24) having a primary focus (F1) at which the incoming radiation is focused by the primary mirrors. A plurality of ellipsoidal mirrors (30a, 30b, 30cand 30d) are carried at an inclination to the optical axis behind the primary focus (F1). A rotating carrier (32) is provided on which the ellipsoidal mirrors are carried so that a desired one of the ellipsoidal mirrors may be selectively positioned in front of the incoming radiation beam (26). In the preferred embodiment, each of the ellipsoidal mirrors has an identical concave surface carrying a layered synthetic microstructure coating tailored to reflect a desired wavelength of 1.5 .ANG. or longer. Each of the identical ellipsoidal mirrors has a second focus (F2) at which a detector (16) is carried. Thus the different wavelength image is focused upon the detector irregardless of which mirror is positioned in front of the radiation beam. In this manner, a plurality of low wavelengths in a wavelength band generally less than 30 angstroms can be imaged with a high resolution.

Hoover, Richard B.↗

On-orbit Characterization of RVS for MODIS Thermal Emissive Bands

Response versus scan angle (RVS) is a key calibration parameter for remote sensing radiometers that make observations using a scanning optical system, such as a scan mirror in MODIS and GLI or a rotating telescope in SeaWiFS and VIIRS, since the calibration is typically performed at a fixed viewing angle while the Earth scene observations are made over a range of viewing angles. Terra MODIS has been in operation for more than four years since its launch in December 1999. It has 36 spectral bands covering spectral range from visible (VIS) to long-wave infrared (LWIR). It is a cross-track scanning radiometer using a two-sided paddle wheel scan mirror, making observations over a wide field of view (FOV) of +/-55 deg from the instrument nadir. This paper describes on-orbit characterization of MODIS RVS for its thermal emissive bands (TEB), using the Earth view data collected during Terra spacecraft deep space maneuvers (DSM). Comparisons with pre-launch analysis and early on-orbit measurements are also provided.

Xiong, X.↗

Coriolis-force-induced trajectory and endpoint deviations in the reaching movements of labyrinthine-defective subjects

When reaching movements are made during passive constant velocity body rotation, inertial Coriolis accelerations are generated that displace both movement paths and endpoints in their direction. These findings directly contradict equilibrium point theories of movement control. However, it has been argued that these movement errors relate to subjects sensing their body rotation through continuing vestibular activity and making corrective movements. In the present study, we evaluated the reaching movements of five labyrinthine-defective subjects (lacking both semicircular canal and otolith function) who cannot sense passive body rotation in the dark and five age-matched, normal control subjects. Each pointed 40 times in complete darkness to the location of a just extinguished visual target before, during, and after constant velocity rotation at 10 rpm in the center of a fully enclosed slow rotation room. All subjects, including the normal controls, always felt completely stationary when making their movements. During rotation, both groups initially showed large deviations of their movement paths and endpoints in the direction of the transient Coriolis forces generated by their movements. With additional per-rotation movements, both groups showed complete adaptation of movement curvature (restoration of straight-line reaches) during rotation. The labyrinthine-defective subjects, however, failed to regain fully accurate movement endpoints after 40 reaches, unlike the control subjects who did so within 11 reaches. Postrotation, both groups' movements initially had mirror image curvatures to their initial per-rotation reaches; the endpoint aftereffects were significantly different from prerotation baseline for the control subjects but not for the labyrinthine-defective subjects reflecting the smaller amount of endpoint adaptation they achieved during rotation. The labyrinthine-defective subjects' movements had significantly lower peak velocity, higher peak elevation, lower terminal velocity, and a more vertical touchdown than those of the control subjects. Thus the way their reaches terminated denied them the somatosensory contact cues necessary for full endpoint adaptation. These findings fully contradict equilibrium point theories of movement control. They emphasize the importance of contact cues in adaptive movement control and indicate that movement errors generated by Coriolis perturbations of limb movements reveal characteristics of motor planning and adaptation in both healthy and clinical populations.

NASA Discipline Neuroscience↗

Band-to-Band Misregistration of the Images of MODIS Onboard Calibrators and Its Impact on Calibration

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments aboard Terra and Aqua satellites are radiometrically calibrated on-orbit with a set of onboard calibrators (OBCs), including a solar diffuser, a blackbody, and a space view port through which the detectors can view the dark space. As a whisk-broom scanning spectroradiometer, thirty-six MODIS spectral bands are assembled in the along-scan direction on four focal plane assemblies (FPAs). These bands capture images of the same target sequentially with the motion of a scan mirror. Then the images are coregistered onboard by delaying the appropriate band-dependent amount of time, depending on the band locations on the FPA. While this coregistration mechanismis functioning well for the far-field remote targets such as earth view scenes or the moon, noticeable band-to-band misregistration in the along-scan direction has been observed for near field targets, particularly in OBCs. In this paper, the misregistration phenomenon is presented and analyzed. It is concluded that the root cause of the misregistration is that the rotating element of the instrument, the scan mirror, is displaced from the focus of the telescope primary mirror. The amount of the misregistrationis proportional to the band location on the FPA and is inversely proportional to the distance between the target and the scan mirror. The impact of this misregistration on the calibration of MODIS bands is discussed. In particular, the calculation of the detector gain coefficient m1of bands 8-16 (412 nm 870 nm) is improved by up to 1.5% for Aqua MODIS.

Wang, Zhipeng↗

Characterization of X-Ray Diffraction System with a Microfocus X-Ray Source and a Polycapillary Optic

We present here an optimized microfocus x-ray source and polycapillary optic system designed for diffraction of small protein crystals. The x-ray beam is formed by a 5.5mm focal length capillary collimator coupled with a 40 micron x-ray source operating at 46Watts. Measurements of the x-ray flux, the divergence and the spectral characteristics of the beam are presented, This optimized system provides a seven fold greater flux than our recently reported configuration [M. Gubarev, et al., J. of Applied Crystallography (2000) 33, in press]. We now make a comparison with a 5kWatts rotating anode generator (Rigaku) coupled with confocal multilayer focusing mirrors (Osmic, CMF12- 38Cu6). The microfocus x-ray source and polycapillary collimator system delivers 60% of the x-ray flux from the rotating anode system. Additional ways to improve our microfocus x-ray system, and thus increase the x-ray flux will be discussed.

Gubarev, Mikhail↗

Polarization Flipping of Even-Order Harmonics in Monolayer Transition-Metal Dichalcogenides

We present a systematic study of the crystal-orientation dependence of high-harmonic generation in monolayer transition-metal dichalcogenides, WS 2 and MoSe 2 , subjected to intense linearly polarized midinfrared laser fields. The measured spectra consist of both odd- and even-order harmonics, with a high-energy cutoff extending beyond the 15th order for a laser-field strength around ~1 V/nm. In WS 2 , we find that the polarization direction of the odd-order harmonics smoothly follows that of the laser field irrespective of the crystal orientation, whereas the direction of the even-order harmonics is fixed by the crystal mirror planes. Furthermore, the polarization of the even-order harmonics shows a flip in the course of crystal rotation when the laser field lies between two of the crystal mirror planes. By numerically solving the semiconductor Bloch equations for a gapped-graphene model, we qualitatively reproduce these experimental features and find the polarization flipping to be associated with a significant contribution from interband polarization. In contrast, high-harmonic signals from MoSe 2 exhibit deviations from the laser-field following of odd-order harmonics and crystal-mirror-plane following of even-order harmonics. We attribute these differences to the competing roles of the intraband and interband contributions, including the deflection of the electron-hole trajectories by nonparabolic crystal bands.

36 MATERIALS SCIENCE↗