Search NASA⌕ Search

SEARCH · Search NASA

Results for “safety testing protocols”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SU-E-I-20: Comprehensive Quality Assurance Test of Second Generation Toshiba Aquilion Large Bore CT Simulator Based On AAPM TG-66 Recommendations

Purpose: AAPM radiation therapy committee task group No. 66 (TG-66) published a report which described a general approach to CT simulator QA. The report outlines the testing procedures and specifications for the evaluation of patient dose, radiation safety, electromechanical components, and image quality for a CT simulator. The purpose of this study is to thoroughly evaluate the performance of a second generation Toshiba Aquilion Large Bore CT simulator with 90 cm bore size (Toshiba, Nasu, JP) based on the TG-66 criteria. The testing procedures and results from this study provide baselines for a routine QA program. Methods: Different measurements and analysis were performed including CTDIvol measurements, alignment and orientation of gantry lasers, orientation of the tabletop with respect to the imaging plane, table movement and indexing accuracy, Scanogram location accuracy, high contrast spatial resolution, low contrast resolution, field uniformity, CT number accuracy, mA linearity and mA reproducibility using a number of different phantoms and measuring devices, such as CTDI phantom, ACR image quality phantom, TG-66 laser QA phantom, pencil ion chamber (Fluke Victoreen) and electrometer (RTI Solidose 400). Results: The CTDI measurements were within 20% of the console displayed values. The alignment and orientation for both gantry laser and tabletop, as well as the table movement and indexing and scanogram location accuracy were within 2mm as specified in TG66. The spatial resolution, low contrast resolution, field uniformity and CT number accuracy were all within ACR’s recommended limits. The mA linearity and reproducibility were both well below the TG66 threshold. Conclusion: The 90 cm bore size second generation Toshiba Aquilion Large Bore CT simulator that comes with 70 cm true FOV can consistently meet various clinical needs. The results demonstrated that this simulator complies with the TG-66 protocol in all aspects including electromechanical component, radiation safety component, and image quality component. Employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

FINAL REPORT - Development of High Pressure Hydrogen Storage Tank for Storage and Gaseous Truck Delivery

The “Development of High Pressure Hydrogen Storage Tanks for Storage and Gaseous Truck Delivery” project [DE-FG36-08GO18062] was initiated on 01 July 2008. Hexagon Lincoln (then Lincoln Composites) received grant funding from the U.S. Department of Energy to support the design and development of an improved bulk hauling and storage solution for hydrogen in terms of cost, safety, weight and volumetric efficiency. The development of this capability required parallel development and qualification of large all-composites pressure vessels, a custom ISO container to transport and store said tanks, and performance of trade studies to identify optimal operating pressure for the system. Qualification of the 250 bar TITAN® module was completed in 2009 with supervision from the American Bureau of Shipping [ABS], and the equipment has been used internationally for bulk transportation of fuel gases since 2010. Phase 1 of the project was successfully completed in 2012 with the issuance of USDOT SP 14951, the special permit authorizing the manufacture, marking, sale and use of TITAN® Mobile Pipeline® equipment in the United States. The introduction of tube trailers with light weight composite tankage has meant that 2 to 3 times as much gaseous fuel can be transported with each trip. This increased hauling efficiency offers dramatically reduced operating costs and has enabled a profitable business model for over-the-road compressed natural gas delivery. The economic drivers of this business opportunity vary from country to country and region to region, but in many places gas distribution companies have realized profitable operations. Additional testing was performed in 2015 to characterize hydrogen-specific operating protocols for use of TITAN® systems in CHG service at 250 bar. This program demonstrated that existing compression and decompression methodologies can efficiently and safely fill and unload lightweight bulk hauling systems. Hexagon Lincoln and U.S. DOE agreed to continue into Phase 2 of the project without pursuing the development of higher pressure capabilities as originally planned. At 250 bar, development of equipment for hydrogen transport is supported by strong activity in the adjacent natural gas transportation sector. Trade studies performed since 2011 indicate optimization of hauling efficiency and system cost for hydrogen transport at about 350 bar (5076 psi). However, due to reduced efficiency of compression of natural gas above 250 bar, 350 bar operation is not an attractive option for natural gas transportation. The CHG market is not developed at this time, and it is difficult to forecast the arrival of significant revenues. On the investment side, the cost to fully qualify a large tank module at 350 bar is estimated at $3MM to $5MM. There is insufficient CHG market definition to support a stand-alone business case for this investment without near term revenue in the adjacent CNG transportation market. Therefore development of a 350 bar TITAN® system was deferred and not pursued under this project. Hexagon Lincoln continues to support the development of tankage and equipment for operation at 350 bar and above; with 700 bar vehicle tanks and 950 bar tanks for ground storage applications. Phase 2 activities were focused on reducing system cost, increasing system capacity, increasing system safety and characterization of polymer material performance specific to hydrogen pressure vessel usage. With the successful launch of TITAN® modules and trailers in natural gas transportation, over 600 units have been produced through the end of 2016, resulting in improved purchasing power for raw materials and manufactured components. This has allowed Hexagon Lincoln to approach the current project goals for system cost. At $590/kg of compressed hydrogen delivered, the system cost of the baseline TITAN® module is below the project’s 2015 target of $730/kg H2 delivered, and very close to the project’s 2020 target of $575/kg H2 delivered. [Based on product pricing in 1Q2017.] Emphasis was placed on configuration of larger capacity systems within the vehicle weights and dimensions allowed on federal and state highways in the United States and other countries. These activities resulted in the design and development of integrated tube trailer systems that have increased delivery capacities by 45%. The hydrogen delivery capacity of our largest system is 845 kg, exceeding the project’s 2015 target of 700 kg H2 delivered. Emerging technologies offering improvement of the safety systems used on the equipment were investigated, with particular focus on improving the reliability and cost of the emergency venting system for fire protection. Finally, investment in our materials laboratory improved detection and characterization of hydrogen-induced damage in polymer materials, supporting the development of operational protocols to avoid damage to pressure vessel liners and valve components.

08 HYDROGEN↗

A Distributed Simulation-to-Flight Framework to Support Investigating Trust/Trustworthiness in Multi-Agent Systems

As autonomous systems continue to grow both in use and complexity, the necessity for robust and extensible simulation-to-flight frameworks is paramount for establishing an effective architecture for autonomous systems. Hardware test flights are time-consuming and cost prohibitive during early system design and development. Simulation environments can be useful tools to accelerate algorithm development and testing. However, transitions from simulation to flight (sim-to-flight) can be challenging, unless systems are designed with this transition in mind and with the necessary capabilities built into the architecture and framework. One of the objectives of Autonomy Teaming and TRAjectories for Complex Trusted Operational Reliability (ATTRACTOR) was to design and develop a distributed mixed-reality simulation environment to begin establishing a basis for certification of autonomous systems via research into trust and trustworthiness. ATTRACTOR’s objective was to construct computational concepts of trustworthiness and justifiable trust in multi-agent autonomous teams, to inform future certification of safety-critical and time-critical autonomous systems in aviation. In this paper, we present an autonomous systems architecture and development framework paired with a persistent distributed modeling and simulation (ModSim) environment for test and evaluation of autonomous systems. They were designed under ATTRACTOR in order to measure and establish trustworthiness and trust in single-and multi-agent human-machine systems whether these machines are fixed-wing general aviation, rotary-wing Unmanned Aerial Vehicles (UAVs), ground rovers, or even spacecraft. The Autonomous Entity Operational Network (AEON) framework enables autonomous system development with an easily extensible collection of libraries and plug-n-play nodes facilitated by the Data Distribution Service (DDS) communication protocol standard. The Baseline Environment for Autonomous Modeling (BEAM) simulation environment is a distributed mixed-reality Unity™-based environment built around the same DDS communication paradigm allowing for easy integration with AEON-based autonomous applications, enabling sim-to-flight with minimal configuration changes. Using AEON and BEAM, source code that runs in simulation ports directly to hardware and has successfully flown in the National Airspace System (NAS) at NASA LaRC many times over the lifetime of ATTRACTOR.

Benjamin N Kelley↗

Microgravity Flame Spread in Exploration Atmospheres: Pressure, Oxygen, and Velocity Effects on Opposed and Concurrent Flame Spread

Microgravity tests of flammability and flame spread were performed in a low-speed flow tunnel to simulate spacecraft ventilation flows. Three thin fuels were tested for flammability (Ultem 1000 (General Electric Company), 10 mil film, Nomex (Dupont) HT90-40, and Mylar G (Dupont) and one fuel for flame spread testing (Kimwipes (Kimberly-Clark Worldwide, Inc.). The 1g Upward Limiting Oxygen Index (ULOI) and 1g Maximum Oxygen Concentration (MOC) are found to be greater than those in 0g, by up to 4% oxygen mole fraction, meaning that the fuels burned in 0g at lower oxygen concentrations than they did using the NASA Standard 6001 Test 1 protocol. Flame spread tests with Kimwipes were used to develop correlations that capture the effects of flow velocity, oxygen concentration, and pressure on flame spread rate. These correlations were used to determine that over virtually the entire range of spacecraft atmospheres and flow conditions, the opposed spread is faster, especially for normoxic atmospheres. The correlations were also compared with 1g MOC for various materials as a function of pressure and oxygen. The lines of constant opposed flow agreed best with the 1g MOC trends, which indicates that Test 1 limits are essentially dictated by the critical heat flux for ignition. Further evaluation of these and other materials is continuing to better understand the 0g flammability of materials and its effect on the oxygen margin of safety.

Olson, Sandra L.↗

GenomeTrakr proficiency testing for foodborne pathogen surveillance: an exercise from 2015

Pathogen monitoring is becoming more precise as sequencing technologies become more affordable and accessible worldwide. This transition is especially apparent in the field of food safety, which has demonstrated how whole-genome sequencing (WGS) can be used on a global scale to protect public health. GenomeTrakr coordinates the WGS performed by public-health agencies and other partners by providing a public database with real-time cluster analysis for foodborne pathogen surveillance. Because WGS is being used to support enforcement decisions, it is essential to have confidence in the quality of the data being used and the downstream data analyses that guide these decisions. Routine proficiency tests, such as the one described here, have an important role in ensuring the validity of both data and procedures. In 2015, the GenomeTrakr proficiency test distributed eight isolates of common foodborne pathogens to participating laboratories, who were required to follow a specific protocol for performing WGS. Resulting sequence data were evaluated for several metrics, including proper labelling, sequence quality and new single nucleotide polymorphisms (SNPs). Illumina MiSeq sequence data collected for the same set of strains across 21 different laboratories exhibited high reproducibility, while revealing a narrow range of technical and biological variance. The numbers of SNPs reported for sequencing runs of the same isolates across multiple laboratories support the robustness of our cluster analysis pipeline in that each individual isolate cultured and resequenced multiple times in multiple places are all easily identifiable as originating from the same source.

59 BASIC BIOLOGICAL SCIENCES↗

Tribal Revegetation Project Final Project Report: 92-Acre Area, Area 5 Radioactive Waste Management Complex, Nevada National Security Site, Nevada

Nuwu (Southern Paiute), Newe (Western Shoshone), and Nuumu (Owens Valley Paiute) are linguistically related, Numic-speaking peoples who are part of the broader Uto-Aztecan language group. Numic peoples view the land as a holistic, living, sentient being with feelings and purpose. The land is personified with human characteristics and it needs to be experienced to be understood through “learning by doing.” Numic peoples do not support ground disturbing activities within their ancestral lands, including activities tied to the storage of low-level radioactive waste or classified materials on the NNSS, which they view as culturally inappropriate. These deep-rooted ancestral connections are the impetus for reinforcing Numic responsibility for healing disturbed areas by integrating respect and patience with consistent Tribal interaction. Tribal Ecological Knowledge (TEK) is the science of describing Tribal approaches for understanding natural resources. Numic TEK is embedded in traditional teachings learned incrementally over time though experience and it evolves through lessons learned and responses to environmental changes over millennia. Therefore, TEK can broaden and enhance Western scientific knowledge associated with revegetation, especially in highly disturbed areas. The project blended TEK with Western scientific ecological methods to create a vegetative cover within test plots on the 92-Acre Area located at the Radioactive Waste Management Complex (RWMC) located in Area 5 on the Nevada National Security Site (NNSS). The vegetated test plots were systematically created for the Department of Energy (DOE) in tandem with the existing Federal Facilities Agreement and Consent Order (FFACO) with the Nevada Department of Environmental Protection (NDEP). Three previous contractor-lead attempts at revegetation, one targeting full cover revegetation and two targeting test plot revegetation, did not achieve the anticipated results at this location. When presented to the 16 American Indian Tribal nations and affiliated groups with cultural and historical ties to the NNSS, the group appointed a Tribal Revegetation Committee (TRC) that included six expert Tribal knowledge holders to collaborate with an ethnoecologist/cultural anthropologist and two biologists. Project design, planning, seed and outplant selection, spiritual land preparation, and methodology were guided by the TRC and an ethnoecologist/cultural anthropologist from Portland State University (PSU) and biologists from Desert Research Institute (DRI). Using TEK, the TRC recommended a specific seed mixture that contained nine native plant species and three species of outplants. The revegetation effort included preparing and planting thirty 10 m × 10 m (32.8 ft × 32.8 ft) seeded plots, twelve of which also included outplants; and eight 10 m × 100 m (32.8 ft × 328 ft) plots that only received outplants, all atop a waste cell cover. The TRC and the project team creatively adapted TEK with Western scientific methods so that the planned revegetation efforts could occur within the safety and security parameters of the RWMC. Test plots were subjected to one of five soil treatments with varying combinations of straw or mulch applications, soil amendment, and/or outplant planting and one of two watering treatments (watered or unwatered). Planting was divided into two events: one in the fall season and another during the subsequent spring season based on TEK and a corresponding recommendation from the TRC. Monitoring and spiritual management was conducted by the TRC to evaluate plant progress on a monthly basis (in conjunction with the biologist and anthropologist) during each respective growing season for a period of three years after planting. This approach allowed Tribal members the opportunity to conduct traditional blessings and other culturally appropriate activities to restore balance to the land in accordance with Tribal protocols. Following TEK-guided methods, successful plant establishment from seed stock and outplants was observed in many plots. Overall, plots planted in the spring, as recommended by the TRC, showed higher rates of outplant survival and native seedling emergence than those planted in the fall. This finding is significant because it is contrary to the original guidance and previous approaches provided for planting in this region. The TRC believes the frequent co-occurrence of native seedlings near surviving outplants indicates an important symbiotic relationship understood by Tribal communities and overlooked by others. Watered outplants displayed much higher survivability than unwatered plants, even after watering was reduced after the plants were established. Soil amendments and mulch created higher densities of native plants from seed. Many native seedlings showed significant delays in germination, which is considered a normal adaptation to desert climates. Some native plants did not germinate until the third growing year, whereas others germinated during the first growing year, which demonstrates the complexity of the desert environment. Evidence of native insects, reptiles, mammals, and birds, as well as native plants that were not part of the planted species, were noted and considered culturally significant. Despite the presence of non-native plants, native outplants continued to thrive and the incidence of native plant germination from seed increased over time. These successful revegetation results where previous efforts were unsuccessful reinforce the importance of integrating regionally appropriate, TEK-guided methodology with Western science to achieve positive results and the necessity of integrating Tribal involvement in all stages of the revegetation effort. Expanded approaches coupled with Tribal knowledge and tools from Western science addressed a complex problem tied to revegetating atop a low-level radioactive waste cell. The level of Tribal participation serves as a progressive model for building collaborative relationships and addressing ecological challenges on the NNSS.

54 ENVIRONMENTAL SCIENCES↗

Female Astronauts Exhibit Greater Reductions in Aerobic Peak Power Following Long-Duration Space Flight than Males

BACKGROUND: Long-duration exposure to microgravity during space flight causes cardiovascular deconditioning, ultimately reducing aerobic fitness. While sex-based differences play an integral role in health on Earth, there is a paucity of data to inform space flight-induced health and performance implications for female astronauts, which may be critical to ensure health, safety, and mission success. Therefore, this retrospective investigation characterized aerobic capacity in female and male astronauts to inform whether sex differences exist from pre to postflight. METHODS: A NASA historical database (n=47 crew; 11 female, 36 male) of International Space Station (ISS) crewmembers was used to characterize sex differences in aerobic capacity changes from pre to postflight to update the NASA Aerobic and Muscle Risk Evidence Report. Aerobic capacity (VO2pk; ml/kg/min) and peak power (W) were assessed using a graded cycling exercise protocol that included a 3-min warmup at 50 W, with stepwise increases in resistance (25 W/min) until volitional fatigue. Group differences in baseline demographics and the percent change in aerobic capacity from preflight (~90 days before launch) to postflight (~3 days after return) were compared using independent t-tests. Significance was set at P<0.05 (Mean ±SD). RESULTS: At preflight, females were younger (44.5±6.6 vs 48.6±5.6 yrs; p=0.041), weighed less (68.8±10.0 vs 81.0±8.8 kg; p< 0.001), with lower VO2pk (32.8±5.9 vs 37.8±6.0 ml/kg/min; p=0.021) and aerobic peak power (229±42 vs 299±52 W; p< 0.001) than males, but had similar heart rate at VO2pk (176.0±7.3 vs 173.0±10.8 beats/min; p=0.406). ISS flight durations (F: 205.0±58.3 vs M: 176.0±40.5 days; p=0.061) and reductions in VO2pk from pre to postflight were comparable between sexes (F: -11.8±10.7%; M: -8.8%±7.9%; p=0.32). However, females had a greater reduction in aerobic peak power than males (−13.3%±8.9% vs −4.9%±8.8%; p < 0.01). CONCLUSIONS: These data indicate that some indicators of fitness (i.e., aerobic peak power) are more impacted in female astronauts compared to males after long-duration space flight missions. Future investigations with larger sample sizes are necessary to identify the physiological basis of sex-based differences and develop effective countermeasure approaches for both sexes.

Nicole C Strock↗

Nominal Device Support for ATCA Shelf Manager

The ATCA standard specifies a mandatory Shelf Manager (ShM) unit which is a key element for the system operation. It includes the Intelligent Platform Management Controller (IPMC) which monitors the system health, retrieves inventory information and controls the Field Replaceable Units (FRUs). These elements enable the intelligent health monitoring, providing high-availability and safety operation, ensuring the correct system operation. For critical systems like ones of tokamak ITER these features are mandatory to support the long pulse operation. The Nominal Device Support (NDS) was designed and developed for the ITER CODAC Core System (CCS), which will be the responsible for plant Instrumentation and Control (I and C), supervising and monitoring on ITER. It generalizes the Enhanced Physics and Industrial Control System (EPICS) device support interface for Data Acquisition (DAQ) and timing devices. However the support for health management features and ATCA ShM are not yet provided. This paper presents the implementation and test of a NDS for the ATCA ShM, using the ITER Fast Plant System Controller (FPSC) prototype environment. This prototype is fully compatible with the ITER CCS and uses the EPICS Channel Access (CA) protocol as the interface with the Plant Operation Network (PON). The implemented solution running in an EPICS Input / Output Controller (IOC) provides Process Variables (PV) to the PON network with the system information. These PVs can be used for control and monitoring by all CA clients, such as EPICS user interface clients and alarm systems. The results are presented, demonstrating the fully integration and the usability of this solution. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancing Risk Analysis for Nanoscale Materials: Report from an International Workshop on the Role of Alternative Testing Strategies for Advancement: Advancing Risk Analysis for Nanoscale Materials

The Society for Risk Analysis (SRA) has a history of bringing thought leadership to topics of emerging risk. In September 2014, the SRA Emerging Nanoscale Materials Specialty Group convened an international workshop to examine the use of alternative testing strategies (ATS) for manufactured nanomaterials (NM) from a risk analysis perspective. Experts in NM environmental health and safety, human health, ecotoxicology, regulatory compliance, risk analysis, and ATS evaluated and discussed the state of the science for in vitro and other alternatives to traditional toxicology testing for NM. Based on this review, experts recommended immediate and near-term actions that would advance ATS use in NM risk assessment. Three focal areas-human health, ecological health, and exposure considerations-shaped deliberations about information needs, priorities, and the next steps required to increase confidence in and use of ATS in NM risk assessment. The deliberations revealed that ATS are now being used for screening, and that, in the near term, ATS could be developed for use in read-across or categorization decision making within certain regulatory frameworks. Participants recognized that leadership is required from within the scientific community to address basic challenges, including standardizing materials, protocols, techniques and reporting, and designing experiments relevant to real-world conditions, as well as coordination and sharing of large-scale collaborations and data. Experts agreed that it will be critical to include experimental parameters that can support the development of adverse outcome pathways. Numerous other insightful ideas for investment in ATS emerged throughout the discussions and are further highlighted in this article.

36 MATERIALS SCIENCE↗

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS↗

Multilayer Electrodes with Metalized Polymer Current Collector for High-Energy Lithium-Ion Batteries with Extreme-Fast-Charging Capability

The pursuit of batteries capable of extreme fast charging (XFC), that also satisfy high energy and safety criteria, poses a significant challenge to current lithium-ion battery technologies. Additionally, the increasing demand for aluminum (Al) and copper (Cu) in electrification, and vehicle light weighting is driving these metals towards near-critical status in the medium term. This study introduced metalized polymer films by depositing an Al or Cu thin layer onto two sides of a polyethylene terephthalate (PET) film – named mPET/Al and mPET/Cu, as lightweight, cost-effective alternatives to traditional metal current collectors in LIBs. We have utilized current collectors that significantly reduce weight (by 73%), thickness (by 33%), and cost (by 85%) compared to traditional metal foil counterparts. We conducted an extensive evaluation of their mechanical and electrical properties, including in-plane and through-plane resistivities, affirming their suitability for the roll-to-roll battery manufacturing process. Additionally, a novel XFC testing protocol was employed to thoroughly assess the cells' (both half and full-cell) performance across various C-rates and under long-term tests. These advancements have the potential to enhance energy density to 280 Wh/kg at the electrode level under 10-minute charging at 6C. Through testing, including a novel XFC protocol across various C-rates and long-term cycling (up to 1000 cycles) in different cell configurations, we have demonstrated the superior performance of these metalized polymer films. Notably, mPET/Cu and mPET/Al foils exhibited comparable capacities to conventional cells under XFC, with the mPET cells showing a 27% improvement in energy density at 6C and maintaining significant energy density after 1000 cycles. This study underscored the potential of mPET foils to revolutionize the roll-to-roll battery manufacturing process and significantly advance the performance metrics of LIBs in EV applications. Moreover, our results suggest that there is potential to enhance the performance of mPET foils, especially mPET/Al, by optimizing the manufacturing process to achieve higher conductivity.

99 GENERAL AND MISCELLANEOUS↗

Towards a CAN IDS Based on a Neural Network Data Field Predictor

Modern vehicles contain a few controller area networks (CANs), which allow scores of on-board electronic control units (ECUs) to communicate messages critical to vehicle functions and driver safety. CAN provides a lightweight and reliable broadcast protocol but is bereft of security features. As evidenced by many recent research works, CAN exploits are possible both remotely and with direct access, fueling a growing CAN intrusion detection system (IDS) body of research. A challenge for pioneering vehicle-agnostic IDSs is that passenger vehicles' CAN message encodings are proprietary, defined and held secret by original equipment manufacturers (OEMs). Targeting detection of next-generation attacks, in which messages are sent from the expected ECU at the expected time but with malicious content, researchers are now seeking to leverage "CAN data models'', which predict future CAN messages and use prediction error to identify anomalous, hopefully malicious CAN messages. Yet, current works model CAN signals post-translation, i.e., after applying OEM-donated or reverse-engineered translations from raw data. We present initial IDS results testing deep neural networks used to predict CAN data at the bit level, targeting IDS capabilities that avoiding reverse engineering proprietary encodings. Our results suggest the method is promising for data with signals exhibiting dependence on previous or concurrent inputs.

Pawelec, Krzysztof↗

Automating CapCom Using Mobile Agents and Robotic Assistants

We have developed and tested an advanced EVA communications and computing system to increase astronaut self-reliance and safety, reducing dependence on continuous monitoring and advising from mission control on Earth. This system, called Mobile Agents (MA), is voice controlled and provides information verbally to the astronauts through programs called personal agents. The system partly automates the role of CapCom in Apollo-including monitoring and managing EVA navigation, scheduling, equipment deployment, telemetry, health tracking, and scientific data collection. EVA data are stored automatically in a shared database in the habitat/vehicle and mirrored to a site accessible by a remote science team. The program has been developed iteratively in the context of use, including six years of ethnographic observation of field geology. Our approach is to develop automation that supports the human work practices, allowing people to do what they do well, and to work in ways they are most familiar. Field experiments in Utah have enabled empirically discovering requirements and testing alternative technologies and protocols. This paper reports on the 2004 system configuration, experiments, and results, in which an EVA robotic assistant (ERA) followed geologists approximately 150 m through a winding, narrow canyon. On voice command, the ERA took photographs and panoramas and was directed to move and wait in various locations to serve as a relay on the wireless network. The MA system is applicable to many space work situations that involve creating and navigating from maps (including configuring equipment for local topology), interacting with piloted and unpiloted rovers, adapting to environmental conditions, and remote team collaboration involving people and robots.

Clancey, William J.↗

Metalized Polymer Current Collector for High-Energy Lithium-Ion Batteries with Extreme Fast-Charging Capability

Electric vehicles are pivotal in the global shift toward decarbonizing road transport, with lithium-ion batteries at the heart of this technological evolution. However, the pursuit of batteries capable of extremely fast charging that also satisfy high energy and safety criteria, poses a significant challenge to current lithium-ion batteries technologies. Additionally, the increasing demand for aluminum (Al) and copper (Cu) in electrification, solar energy technologies, and vehicle light-eighting is driving these metals toward near-critical status in the medium term. This study introduces metalized polythylene terephthalate (mPET) polymer films by depositing an Al or Cu thin layer onto two sides of a polyethylene terephthalate film—named mPET/Al and mPET/Cu, as lightweight, cost-effective alternatives to traditional metal current collectors in lithium-ion batteries. We have fabricated current collectors that significantly reduce weight (by 73%), thickness (by 33%), and cost (by 85%) compared with traditional metal foil counterparts. These advancements have the potential to enhance energy density to 280 Wh kg -1 at the electrode level under 10-min charging at 6 C. Through testing, including a novel extremely fast charging protocol across various C-rates and long-term cycling (up to 1000 cycles) in different cell configurations, the superior performance of these metalized polymer films has been demonstrated. Notably, mPET/Cu and mPET/Al films exhibited comparable capacities to conventional cells under extremely fast charging, with the mPET cells showing a 27% improvement in energy density at 6 C and maintaining significant energy density after 1000 cycles. This study underscores the potential of mPET films to revolutionize the roll-to-roll battery manufacturing process and significantly advance the performance metrics of lithium-ion batteries in electric vehicles applications.

25 ENERGY STORAGE↗

Changes in Oculomotor Behavior and PVT Reaction Time During One Night of Sleep Deprivation

INTRODUCTION: The Psychomotor Vigilance Test (PVT) is a widely used objective measure of sustained attention, alertness, and fatigue. Previous studies consistently show that prolonged wakefulness and disrupted sleep patterns lead to increased lapses of attention and slower reaction times. These findings have critical implications for various professions, including healthcare, aviation, transportation safety, and spaceflight. In this study, we employed linear mixed models (LMM) to investigate hourly-measured 5-minute PVT reaction times during one night of total sleep deprivation. Our goal was to characterize the contribution of homeostatic sleep pressure (time awake) and circadian phase (salivary melatonin levels) on the dynamics of PVT reaction time. MATERIALS & METHODS: Data from twelve human participants were used in the analysis. Participants were healthy non-smokers, aged 18 and 40, with normal sleep habits defined as Pittsburg Sleep Quality Index scores < 5, and Morningness – Eveningness Questionnaire scores > 42 and < 58, respectively. Participants followed a constant-routine protocol and arrived at the NASA sleep laboratory approximately 1 to 2 hours after their habitual waking time. Tympanic temperature was measured every 30 min to provide a real-time estimate of circadian phase. Participants were required to stay awake throughout the laboratory experiment, which continued until their tympanic temperature had returned to baseline levels. This approach ensured that we could capture each participant's circadian trough and recovery, typically occurring between 24 and 26 hours after waking. The PVT and saliva melatonin were measured every hour, starting approximately from 3 hours after awakening. More information about the measurement protocol can be found in the publication by Stone et al. We used PVT reaction times between 100 and 10000 ms to calculate Reciprocal Reaction Times (RRTs). LMM models were employed to assess the contribution of time awake and saliva melatonin levels on changes in RRTs. Two models were created: the first model treated time awake as a fixed effect and the second model considered both the salivary melatonin level and time awake as fixed effects. Participants were included as a random effect in both models. We compared the models using an Analysis of Variance (ANOVA). The models were computed using the 'lmer' function from the 'lme4' package in R, and LMM p-values were determined using Satterthwaite's method. RESULTS: We found that time awake had a statistically significant effect on PVT RRTs during one night of sleep deprivation [χ2 = 2132.4, df = 1, p < 0.001]. In addition, the model including both saliva melatonin levels and time awake was statistically significantly better than one that uses just time awake [χ2 = 17.4, df = 1, p < 0.001]. DISCUSSION & CONCLUSION: As expected, these preliminary results suggest that the time awake and circadian phase each contribute to performance reductions as measured by the PVT. Future analyses will explore the contributions of other factors to the model.

sleep deprivation↗

Can Cell to Cell Thermal Runaway Propagation be Prevented in a Li-ion Battery Module?

Increasing cell spacing decreased adjacent cell damage center dotElectrically connected adjacent cells drained more than physically adjacent cells center dotRadiant barrier prevents propagation when fully installed between BP cells center dotBP cells vent rapidly and expel contents at 100% SOC -Slower vent with flame/smoke at 50% -Thermal runaway event typically occurs at 160 degC center dotLG cells vent but do not expel contents -Thermal runaway event typically occurs at 200 degC center dotSKC LFP modules did not propagate; fuses on negative terminal of cell may provide a benefit in reducing cell to cell damage propagation. New requirement in NASA-Battery Safety Requirements document: JSC 20793 Rev C 5.1.5.1 Requirements - Thermal Runaway Propagation a. For battery designs greater than a 80-Wh energy employing high specific energy cells (greater than 80 watt-hours/kg, for example, lithium-ion chemistries) with catastrophic failure modes, the battery shall be evaluated to ascertain the severity of a worst-case single-cell thermal runaway event and the propensity of the design to demonstrate cell-to-cell propagation in the intended application and environment. NASA has traditionally addressed the threat of thermal runaway incidents in its battery deployments through comprehensive prevention protocols. This prevention-centered approach has included extensive screening for manufacturing defects, as well as robust battery management controls that prevent abuse-induced runaway even in the face of multiple system failures. This focused strategy has made the likelihood of occurrence of such an event highly improbable. b. The evaluation shall include all necessary analysis and test to quantify the severity (consequence) of the event in the intended application and environment as well as to identify design modifications to the battery or the system that could appreciably reduce that severity. In addition to prevention protocols, programs developing battery designs with catastrophic failure modes should take the steps necessary to assess the severity of a possible thermal runaway event. Programs should assess whether there are reasonable design changes that could appreciably affect the severity of the outcome. Evaluation should include environmental effects to surrounding hardware (i.e., temperature, pressure, shock), contamination effects due to any expelled contaminates, and venting propulsive effects when venting overboard.

Jeevarajan, Judith↗

Defining an Abrasion Index for Lunar Surface Systems as a Function of Dust Interaction Modes and Variable Concentration Zones

Unexpected issues were encountered during the Apollo era of lunar exploration due to detrimental abrasion of materials upon exposure to the fine-grained, irregular shaped dust on the surface of the Moon. For critical design features involving contact with the lunar surface and for astronaut safety concerns, operational concepts and dust tolerance must be considered in the early phases of mission planning. To systematically define material selection criteria, dust interaction can be characterized by two-body or three-body abrasion testing, and subcategorically by physical interactions of compression, rolling, sliding and bending representing specific applications within the system. Two-body abrasion occurs when a single particle or asperity slides across a given surface removing or displacing material. Three-body abrasion occurs when multiple particles interact with a solid surface, or in between two surfaces, allowing the abrasives to freely rotate and interact with the material(s), leading to removal or displacement of mass. Different modes of interaction are described in this paper along with corresponding types of tests that can be utilized to evaluate each configuration. In addition to differential modes of abrasion, variable concentrations of dust in different zones can also be considered for a given system design and operational protocol. These zones include: (1) outside the habitat where extensive dust exposure occurs, (2) in a transitional zone such as an airlock or suitport, and (3) inside the habitat or spacesuit with a low particle count. These zones can be used to help define dust interaction frequencies, and corresponding risks to the systems and/or crew can be addressed by appropriate mitigation strategies. An abrasion index is introduced that includes the level of risk, R, the hardness of the mineralogy, H, the severity of the abrasion mode, S, and the frequency of particle interactions, F.

Kobrick, Ryan L.↗

Calibration and Validation of a Finite ELement Model of THor-K Anthropomorphic Test Device for Aerospace Safety Applications

The THOR anthropomorphic test device (ATD) has been developed and continuously improved by the National Highway Traffic Safety Administration to provide automotive manufacturers an advanced tool that can be used to assess the injury risk of vehicle occupants in crash tests. Recently, a series of modifications were completed to improve the biofidelity of THOR ATD [1]. The updated THOR Modification Kit (THOR-K) ATD was employed at Wright-Patterson Air Base in 22 impact tests in three configurations: vertical, lateral, and spinal [2]. Although a computational finite element (FE) model of the THOR had been previously developed [3], updates to the model were needed to incorporate the recent changes in the modification kit. The main goal of this study was to develop and validate a FE model of the THOR-K ATD. The CAD drawings of the THOR-K ATD were reviewed and FE models were developed for the updated parts. For example, the head-skin geometry was found to change significantly, so its model was re-meshed (Fig. 1a). A protocol was developed to calibrate each component identified as key to the kinematic and kinetic response of the THOR-K head/neck ATD FE model (Fig. 1b). The available ATD tests were divided in two groups: a) calibration tests where the unknown material parameters of deformable parts (e.g., head skin, pelvis foam) were optimized to match the data and b) validation tests where the model response was only compared with test data by calculating their score using CORrelation and Analysis (CORA) rating system. Finally, the whole ATD model was validated under horizontal-, vertical-, and lateral-loading conditions against data recorded in the Wright Patterson tests [2]. Overall, the final THOR-K ATD model developed in this study is shown to respond similarly to the ATD in all validation tests. This good performance indicates that the optimization performed during calibration by using the CORA score as objective function is not test specific. Therefore confidence is provided in the ATD model for uses in predicting response in test conditions not performed in this study such those observed in the spacecraft landing. Comparison studies with ATD and human models may also be performed to contribute to future changes in THOR ATD design in an effort to improve its biofidelity, which has been traditionally based on post-mortem human subject testing and designer experience.

Putnam, J. B.↗