Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample integrity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Soils' dirty little secret: Depth–based comparisons can be inadequate for quantifying changes in soil organic carbon and other mineral soil properties

Quantifying changes in soil organic carbon (SOC) stocks and other soil properties is essential for understanding how soils will respond to land management practices and global change. Although they are widely used, comparisons of SOC stocks at fixed depth (FD) intervals are subject to errors when changes in bulk density or soil organic matter occur. The equivalent soil mass (ESM) method has been recommended in lieu of FD for assessing changes in SOC stocks in mineral soils, but ESM remains underutilized for SOC stocks and has rarely been used for other soil properties. In this paper, we draw attention to the limitations of the FD method and demonstrate the advantages of the ESM approach. We provide illustrations to show that the FD approach is susceptible to errors not only for quantifying SOC stocks but also for soil mass-based properties such as SOC mass percent, C:N mass ratio, and δ 13 C. Here we describe the ESM approach and show how it mitigates the FD method limitations. Using bulk density change simulations applied to an empirical dataset from bioenergy cropping systems, we show that the ESM method provides consistently lower errors than FD when quantifying changes in SOC stocks and other soil properties. To simplify the use of ESM, we detail how the method can be integrated into sampling schemes, and we provide an example R computer script that can perform ESM calculations on large datasets. We encourage future studies, whether temporal or comparative, to utilize sampling methods that are amenable to the ESM approach. Overall, we agree with previous recommendations that ESM should be the standard method for evaluating SOC stock changes in mineral soils, but we further suggest that ESM may also be preferred for comparisons of other soil properties including mass percentages, elemental mass ratios, and stable isotope composition.

59 BASIC BIOLOGICAL SCIENCES↗

Performance of a CO 2 sorbent for indoor air cleaning applications: Effects of environmental conditions, sorbent aging, and adsorption of co-occurring formaldehyde

Indoor air cleaning systems that incorporate CO 2 sorbent materials enable HVAC load shifting and efficiency improvements. This study developed a bench-scale experimental system to evaluate the performance of a sorbent under controlled operation conditions. A thermostatic holder containing 3.15 g sorbent was connected to a manifold that delivered CO 2 -enriched air at a known temperature and relative humidity (RH). The air stream was also enriched with 0.8-2.1 ppm formaldehyde. The CO 2 concentration was monitored in real-time upstream and downstream of the sorbent, and integrated formaldehyde samples were collected at different times using DNPH-coated silica cartridges. Sorbent regeneration was carried out by circulating clean air in countercurrent. Almost 200 loading/regeneration cycles were performed in the span of 17 months, from which 104 were carried out at reference test conditions defined by loading with air at 25°C, 38% RH, and 1000 ppm CO 2 , and regenerating with air at 80°C, 3% RH and 400 ppm CO 2 . The working capacity decreased slightly from 43-44 mg CO 2 per g sorbent to 39-40 mg per g over the 17 months. The capacity increased with lower loading temperature (in the range 15-35°C) and higher regeneration temperature, between 40 and 80°C. The CO 2 capacity was not sensitive to the moisture content in the range 6-9 g/m 3 , and decreased slightly when dry air was used. Loading isothermal breakthrough curves were fitted to three simple adsorption models, verifying that pseudo-first-order kinetics appropriately describes the adsorption process. The model predicted that equilibrium capacities decreased with increasing temperature from 15 to 35°C, while adsorption rate constants slightly increased. The formaldehyde adsorption efficiency was 80%-99% in different cycles, corresponding to an average capacity of 86 ± 36 µg/g. Formaldehyde was not quantitatively released during regeneration, but its accumulation on the sorbent did not affect CO 2 adsorption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

JGI-Trichoderma v1.0

There is a series of Python and bash scripts to parse genomics datasets used to evaluate the coevolution of gene families and the feature importance of gene families using an SVM classifier. - Cover analysis: takes a list of single-copy genes in a set of genomes, aligns and builds the gene trees to determine if two gene families have a signature of covariation with one another. It parses the files to run phykit cover script described here: https://jlsteenwyk.com/PhyKIT/usage/index.html - SVM-classifier: This Python script is an SVM-based genomic classifier designed for biological data analysis. It combines machine learning with feature selection to identify important genomic markers and classify biological samples. Core Functionality: The script uses Support Vector Machines from scikit-learn to classify genomic data, incorporating SelectKBest for automated feature selection and leave-one-out cross-validation for performance assessment. It operates in multiple modes: feature ranking, optimal combination discovery, and sample prediction. Primary Applications: Genomic sample classification and biomarker discovery Feature importance analysis in high-dimensional biological datasets Prediction of sample categories based on genomic profiles Research applications requiring robust classification of biological data Key Advantages: High-dimensional handling: SVMs excel with genomic data's typical high feature-to-sample ratios Integrated feature selection: Reduces noise and computational overhead while identifying key markers Probability estimation: Provides confidence scores essential for biological interpretation Validation robustness: Leave-one-out cross-validation ensures reliable performance metrics Operational flexibility: Multiple analysis modes support different research phases from exploration to prediction

Stecca Steindorff, Andrei [Lawrence Berkeley Natio↗

Parallel measurement of transcriptomes and proteomes from same single cells using nanodroplet splitting

Single-cell multiomics provides comprehensive insights into gene regulatory networks, cellular diversity, and temporal dynamics. While tools for co-profiling single-cell genomes, transcriptomes, and epigenomes are available, accessing proteomes in parallel is more challenging. We developed nanoSPLITS (nanodroplet SPlitting for Linked-multimodal Investigations of Trace Samples), an integrated platform that enables global profiling of the transcriptome and proteome from same single cells using RNA sequencing and mass spectrometry-based proteomics, respectively. nanoSPLITS can precisely quantify over 5000 genes, 2000 proteins, and 140 phosphopeptides per single cell and identify candidate cell markers from these modalities. By exploring Cdk1-mediated cell cycle arrest, we demonstrate how nanoSPLITS single-cell multiomics can provide comprehensive cellular characterization with insights into covarying protein/gene clusters, unique phosphorylation events, and mitotic pathways.

59 BASIC BIOLOGICAL SCIENCES↗

Materials in Extremes [Slides]

Goals: Realization of advanced predictive models that capture aspects of processing structure-properties-performance (PSPP) in ways that build on scale bridging, data science, and transformational physics insights from experiments; Based on a robust and seamless integration of sample manufacturing, characterization (pre- and post-mortem), theory and simulation, and novel experiments; Ultimately we want to be able to reliably predict performance, and control the functionality of materials in extreme environments.

36 MATERIALS SCIENCE↗

A new approach to mass spectrometer measurements of thermospheric density

The gas sampling problem in satellite and high velocity probes was investigated by applying the theory of a drifting Maxwellian gas. A lens system using a free stream ion source was developed and experimentally evaluated over the pressure range of 0.00001 to 0.01 N/m sq (approx. 10 to the minus 7th power to 0.0001 torr). The source has high beam transparency, which minimizes gas-surface collisions within, or near, the ionization volume. It is shown that for high ion energy (60 eV), the extracted ion beam has an on-axis energy spread of less than 4 eV, and that 90 percent of the ions are within 2.5 deg of the beam axis. It is concluded that the molecular beam mass spectrometer concept, developed for gas density measurements in the upper atmosphere, substantially reduces gas-surface scattering and gas-surface reactions in the sample, and preserves the integrity of the gas sample during the analysis process. Studies show that both the Scout and Delta launch vehicles have adequate volume, control, velocity, and data acquisition capability necessary to obtain thermospheric number density in real time.

Melfi, L. T., Jr.↗

Programs for computing abscissas and weights for classical and nonclassical Gaussian quadrature formulas

Computer programs for computing Gaussian quadrature abscissas and weights are described. For the classical case the programs use Laguerre iteration to compute abscissas as zeros of orthogonal polynomials. The polynomials are evaluated from known recursion coefficients. The nonclassical case is handled similarly except that the recursion coefficients are computed by numerical integration. A sample problem, with input and output, is presented to illustrate the use of the programs. It computes the quadrature abscissas and weights associated with the weight function over the interval (0,1) for quadrature orders from 16 to 96 in increments of 8.

Desmarais, R. N.↗

The measurement of carbon monoxide and methane in the national capital air quality control region. III - Correlation interferometer results

Two types of experiments were performed with a correlation interferometer on-board a Bell Jet Ranger 206 Helicopter. The first consisted of simultaneous ground- and air-truth measurements as the instrumented helicopter passed over the Cheverly site. The second consisted of several measurement flights in and around the national capital air quality control region (Washington, D.C.). The correlation interferometer data, the infrared Fourier spectrometer data, and the integrated altitude sampling data showed agreement within the errors of the individual measurements. High values for CO were found from the D.C. flight data to be reproducible and concentrated in areas of stop-and-go traffic. It is concluded, that pollutants at low altitudes are detectable from an air-borne platform by remote correlation interferometry and that the correlation interferometer measurements agree with ground- and air-truth data.

Goldstein, H. W.↗

Use of near infrared/red radiance ratios for estimating vegetation biomass and physiological status

The application of photographic infrared/red (ir/red) reflectance or radiance ratios for the estimation of vegetation biomass and physiological status were investigated by analyzing in situ spectral reflectance data from experimental grass plots. Canopy biological samples were taken for total wet biomass, total dry biomass, leaf water content, dry green biomass, dry brown biomass, and total chlorophyll content at each sampling date. Integrated red and photographic infrared radiances were regressed against the various canopy or plot variables to determine the relative significance between the red, photographic infrared, and the ir/red ratio and the canopy variables. The ir/red ratio is sensitive to the photosynthetically active or green biomass, the rate of primary production, and actually measures the interaction between the green biomass and the rate of primary production within a given species type. The ir/red ratio resulted in improved regression significance over the red or the ir/radiances taken separately. Only slight differences were found between ir/red ratio, the ir-red difference, the vegetation index, and the transformed vegetation index. The asymptotic spectral radiance properties of the ir, red, ir/red ratio, and the various transformations were evaluated.

Tucker, C. J.↗

Relationship of land use to water quality in the Chesapeake Bay region

Both the proportions of the various land use categories present on each watershed and the specific management practices in use in each category affect the quality of runoff waters, and the water quality of the Bay. Several permanent and portable stations on various Maryland Rivers collect volume-integrated water samples. All samples are analyzed for a series of nutrient, particulate, bacterial, herbicide, and heavy metal parameters. Each basin is mapped with respect to land use by the analysis of low-elevation aerial photos. Analyses are verified and adjusted by ground truth surveys. Data are processed and stored in the Smithsonian Institution data bank. Land use categories being investigated include forests/old fields, pastureland, row crops, residential areas, upland swamps, and tidal marshes.

Correll, D. L.↗

Water-Vapor Sample Holder for Mass Spectrometers

Water-vapor sample holder for mass spectrometer contains water vapor for calibration. It is sealed by aluminum disk. Calibration sample and integrated circuit modules are tested sequentially in same manner.

Haack, R. F.↗

Spatial inventory integrating raster databases and point sample data

A timber inventory of the Eldorado National Forest, located in east-central California, provides an example of the use of a Geographic Information System (GIS) to stratify large areas of land for sampling and the collection of statistical data. The raster-based GIS format of the VICAR/IBIS software system allows simple and rapid tabulation of areas, and facilitates the selection of random locations for ground sampling. Algorithms that simplify the complex spatial pattern of raster-based information, and convert raster format data to strings of coordinate vectors, provide a link to conventional vector-based geographic information systems.

Strahler, A. H.↗

Optical Integrating Sphere for Vacuum Ultraviolet

Optical integrating sphere with integral sliding sample holder saves time by allowing radiometric measurements made on each of four samples without breaking vacuum. Designed to operate with interior evacuated so dye samples illuminated with short-wavelength ultraviolet strongly absorbed by air; need not be evacuated when using longer wavelengths. Device mounts on monochromator and evacuated through port that admits light from monochromator.

Butner, C. L.↗

Optimal sampling and sensitivity limits of integrating detector arrays in a space environment

The performance of integrating detectors with either destructive read-out or nondestructive direct read-out in a space environment subject to charge-particle and radiation hits was investigated by determining the optimal integration time for maximizing the performance in the presence of a given hit rate. The performance relative to that expected for background-limited performance was evaluated using a combination of analytic techniques and Monte Carlo simulations. Results are used to estimate the performance degradation, due to cosmic rays, of the long-wavelength spectrometer of the Space Infrared Telescope Facility. It was found that its performance may be a factor of 1-5 worse than the background limited performance.

Herter, T.↗

Aerosol measurements in the stratocumulus project

Cloud Condensation Nuclei (CCN) and Condensation Nuclei (CN) were measured from the National Center for Atmospheric Research (NCAR) Electra throughout the marine stratocumulus project. The total particle concentration was measured with a condensation nucleus counter. The CCN were measured with the Desert Research Institute (DRI) instantaneous CCN spectrometer. This instrument simultaneously measures the concentration of aerosol active at up to 100 different critical supersaturations (Sc). This is accomplished by exposing the sample to a fixed supersaturation field and using the size of the droplets produced in this cloud chamber to deduce the Sc of the nuclei upon which they have grown. Droplet size is associated with Sc through a calibration which is accomplished by passing soluble aerosols of known size and composition through the cloud chamber. This procedure results in a calibration curve of Sc vs. droplet size. This then allows the channel number to be directly associated with Sc. Thus, number concentration vs. Sc is obtained and this is a CCN spectrum. Since the instrument operates continuously, the measurements at all Sc's are available simultaneously. Samples are drawn directly from the ambient air and data is displayed in nearly real time. Samples were integrated over times of about 10 seconds so that substantial spatial resolution is available. Calibrations were performed once or twice a day and were found to be consistent. Preliminary results are shown.

Hudson, James G.↗

Exposure ages of carbonaceous chondrites, 1

The recent exposure histories of carbonaceous chondrites have been investigated using cosmogenic radionuclides. Our results may indicate a clustering of exposure ages of C1 and C2 chondrites into two peaks, 0.2 My and 0.6 My, perhaps implying two collisional events of Earth-crossing parent bodies. Among carbonaceous chondrites are some having short exposure ages which Mazor et al. hypothesized cluster into a small number of families. This hypothesis is based on spallogenic Ne-21 exposure ages, which in some instances are difficult to determine owing to the large amounts of trapped noble gases in carbonaceous chondrites. Also, since Ne-21 is stable, it integrates a sample's entire exposure history, so meteorites with complex exposure histories are difficult to understand using exclusively Ne-21. Cosmogenic radionuclides provide an alternative means of determining the recent cosmic ray exposure duration. To test the hypothesis of Mazor et al. we have begun a systematic investigation of exposure histories of Antarctic and non-Antarctic carbonaceous chondrites especially C2s.

Nishiizumi, K.↗

Reliability-Based Control Design for Uncertain Systems

This paper presents a robust control design methodology for systems with probabilistic parametric uncertainty. Control design is carried out by solving a reliability-based multi-objective optimization problem where the probability of violating design requirements is minimized. Simultaneously, failure domains are optimally enlarged to enable global improvements in the closed-loop performance. To enable an efficient numerical implementation, a hybrid approach for estimating reliability metrics is developed. This approach, which integrates deterministic sampling and asymptotic approximations, greatly reduces the numerical burden associated with complex probabilistic computations without compromising the accuracy of the results. Examples using output-feedback and full-state feedback with state estimation are used to demonstrate the ideas proposed.

Crespo, Luis G.↗

Atomic Oxygen Exposure of Polyimide Foam for International Space Station Solar Array Wing Blanket Box

Onorbit photos of the International Space Station (ISS) solar array blanket box foam pad assembly indicate degradation of the Kapton film covering the foam, leading to atomic oxygen (AO) exposure of the foam. The purpose of this test was to determine the magnitude of particulate generation caused by low-Earth orbital environment exposure of the foam and also by compression of the foam during solar array wing retraction. The polyimide foam used in the ISS solar array wing blanket box assembly is susceptible to significant AO erosion. The foam sample in this test lost one-third of its mass after exposure to the equivalent of 22 mo onorbit. Some particulate was generated by exposure to simulated orbital conditions and the simulated solar array retraction (compression test). However, onorbit, these particles would also be eroded by AO. The captured particles were generally <1 mm, and the particles shaken free of the sample had a maximum size of 4 mm. The foam sample maintained integrity after a compression load of 2.5 psi.

Finckenor, M. M.↗