Search NASA⌕ Search

SEARCH · Search NASA

Results for “saturation temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Preliminary Testing of a Continuous Cryopump for Primary Fusion Device Pumping and Direct Internal Recycling

Here, the concept of directly recirculating fusion machine exhaust gas, bypassing the tritium plant, to make fuel pellets was proposed in the 1990s and later termed direct internal recycling (DIR). In the DIR concept, the residual fusion fuel in the machine exhaust stream is separated from impurities locally and diverted directly to the fueling systems, bypassing isotopic separation and other processing equipment, and therefore significantly reducing the required size of the fuel processing plant, reducing plant inventory, and thus increasing the economic viability of fusion as an energy source. One concept for DIR consists of a series of cryogenic pumps to separate the impurities from the machine exhaust gas using different triple point temperatures and saturation curves of exhaust constituents. In this concept, the plasma exhaust is initially passed through an impurity trap operating at ~25–30 K to desublimate impurities such as hydrocarbons, argon, oxygen, and nitrogen. The resulting process stream will consist of DT fuel and helium. The process stream is then pumped by a continuous cryopump known as a “snail pump.” This pump is a steady-state continuous cryopump that desublimates all remaining exhaust gas constituents while allowing helium, a byproduct of the fusion reaction, to pass through. The helium is pumped to the tritium plant for processing while the desublimated material is continuously scraped off, heated up, and transported to the fueling system. This article will present the cryogenic DIR concept and outline the design and operation of the snail pump, along with results from preliminary testing. Tests to assess pumping and separation efficiency found that at D2 flows below 50.7 Pa ⋅ m3/s with 1% helium, the pump is capable of pumping and separating the gas with a resulting DIR fraction of >99%, with no helium entrained in the primary fuel exhaust stream. The main limitation is due to the thermal performance of the cryogenic circuits of the pump, which will be addressed in future testing.

Gebhart III, Trey E. [Oak Ridge National Laborator↗

First application of a digital mirror Langmuir probe for real-time plasma diagnosis

For the first time, a digital Mirror Langmuir probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I-V characteristics with a high frequency, high power digital amplifier and field-programmable gate array (FPGA) controller. Measurements taken by the MLP were validated by a low speed I-V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field (f̃ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it towards a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution such as edge plasma, scrape-off layer, and divertor probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An equation of state for oxygen and nitrogen

Recent measurements of the thermodynamic properties of oxygen and nitrogen have been used to develop a single equation of state for both fluids; with appropriate coefficients, the equation describes the pressure-density-temperature surface for each fluid within the estimated experimental uncertainty of the data. The formulation uses least squares curve fitting of the equation of state to the available experimental data (including pressure-density-temperature data, saturation data, and measured isochoric heat capacities). New vapor pressure equations and equations for the ideal gas heat capacities of oxygen and nitrogen are included for use in calculation of derived thermodynamic properties.

Jacobsen, R. T.↗

Magnetization and magnetic susceptibility of DyH3

The magnetization and differential magnetic susceptibility of powdered DyH3 samples are measured at a temperature of 4.2 K in applied magnetic fields ranging up to 9 Teslas. The differential magnetic susceptibility is also investigated in the zero applied field. Magnetization is plotted as a function of field strength, and differential susceptibility is described as a function of both field strength and temperature. A saturation magnetic moment of 5.12 Bohr magnetons per ion is derived from the magnetization data, and the zero-field susceptibility measurements are found to indicate antiferromagnetic ordering below 3.45 K. The susceptibility at 4.2 K is shown to have an inverse-square dependence on field strength for values of not less than 0.3 Tesla.

Flood, D. J.↗

Specific cooling capacity of liquid nitrogen

The assumed cooling process and the method used to calculate the specific cooling capacity of liquid nitrogen are described, and the simple equation fitted to the calculated specific cooling capacity data, together with the graphical form calculated values of the specific cooling capacity of nitrogen for stagnation temperatures from saturation to 350 K and stagnation pressures from 1 to 10 atmospheres, are given.

Kilgore, R. A.↗

Release of dissolved nitrogen from water during depressurization

Experiments were run to study depressurization of water containing various concentrations of dissolved nitrogen gas, the primary case being room temperature water saturated with nitrogen at 4 MPa. In a static depressurization experiment, water with very high nitrogen content was depressurized at rates from 0.09 to 0.50 MPa per second and photographed with high speed movies. The pictures showed that the bubble population at a given pressure increased strongly with decreasing depressurization rate. Flow experiments were performed in an axisymmetric converging-diverging nozzle and in a two-dimensional converging nozzle with glass sidewalls. Depressurization gradients were roughly 500 to 1200 MPa per second. Both nozzles exhibited choked flow behavior even at nitrogen concentration levels as low as 4 percent of saturated. The flow rates were independent of concentration level and could be computed as incompressible water flow based on the difference between stagnation and throat pressures; however, the throat pressures were significantly different between the two nozzles.

Simoneau, R. J.↗

Release of dissolved nitrogen from water during depressurization

Experiments were run to study depressurization of water containing various concentrations of dissolved nitrogen gas, the primary case being room-temperature water saturated with nitrogen at 4 MPa. In a static depressurization experiment, water with very high nitrogen content was depressurized at rates from 0.09 to 0.50 MPa per second and photographed with high-speed movies. The pictures showed that the bubble population at a given pressure increased strongly with decreasing depressurization rate. Bubbles rarely appeared before the pressure reached half the initial pool pressure. Flow experiments were performed in an axisymmetric converging-diverging nozzle and in a two-dimensional converging nozzle with glass sidewalls. Depressurization gradients were roughly 500 to 1200 MPa per second. Both nozzles exhibited choked flow behavior even at nitrogen concentration levels as low as 4 percent of saturated. The flow rates were independent of concentration level and could be computed as incompressible water flow based on the difference between stagnation and throat pressures; however, the throat pressures were significantly different between the two nozzles

Simoneau, R. J.↗

A model to determine open or closed cellular convection

The horizontal asymmetry of cellular convection is demonstrated to be detectable by consideration of the vertical asymmetry of the driving force. A two-dimensional numerical model for convection in an internally heated and cooled fluid is presented, based on equations for the conservation of temperature and vorticity. Attention is focused on the steady-state finite-amplitude solutions for fixed Rayleigh number, Prandtl number, and aspect ratio. Temperature in the model corresponds to potential temperature under dry conditions and the equivalent potential temperature under saturated conditions. Slowly varying convection driven by asymmetric boundary fluxes is expressed in terms of steady-state convection driven by an asymmetric internal heat source. It is shown that heating near the ground produces open convection patterns where most of the fluid is descending, while cooling near the top of the flow leads to closed cellular patterns with a preponderance of ascending fluid. Extension of the model to three dimensions is indicated.

Helfand, H. M.↗

Impact properties of rubber-modified epoxy resin-graphite-fiber composites

To improve the impact resistance of graphite-fiber composites, a commercial and an experimental epoxy resin were modified with liquid reactive rubber and a brominated epoxy resin. The commercial epoxy was a tetrafunctional resin, and the experimental epoxy was a trifunctional resin. The reactive rubber was a carboxyl-terminated butadiene-acrylonitrile copolymer. The rubber content was varied from 0 to 25 percent (wt). The brominated epoxy resin was used at Br levels of 4, 19, and 35 percent of the resin. Composites were prepared with woven graphite cloth reinforcement. The composites were evaluated by using flexural strength in the dry state and an elevated temperature after saturation with water. The impact properties were determined by measuring shear strength after falling-ball impact and instrumented impact. The rubber-modified, trifunctional resin exhibited better properties, when tested in hot-wet conditions in a heated oven at 366 K (after boiling the material for 2 h in demineralized water), than the tetrafunctional resin. Improved impact resistance was observed with the addition of the reactive rubber to the epoxy resin. Further improvement was observed with the addition of the brominated epoxy resin.

Gilwee, W. J.↗

Mechanical properties testing of candidate polymer matrix materials for use in high performance composites

The mechanical properties of four candidate neat resin systems for use in graphite/epoxy composites are characterized. This includes tensile and shear stiffnesses and strengths, coefficients of thermal and moisture expansion, and fracture toughness. Tests are conducted on specimens in the dry state and moisture-saturated, at temperatures of 23C, 82C and 121C. The neat resins tested are Hexcel HX-1504, Narmco 5245-C, American Cyanamid CYCOM 907, and Union Carbide ERX-4901A (MDA). Results are compared with those obtained for four other epoxy resins tested in a prior program, i.e., Hercules 3502, 2220-1, and 2220-3, and Ciba-Geigy Fibredux 914, as well as with available Hercules 3501-6 data. Scanning electron microscopic examination of fracture surfaces is performed to permit the correlation of observed failure modes with the environmental test conditions. A finite element micromechanics analysis is used to predict unidirectional composite response under various test conditions, using the measured neat resin properties as input data.

Zimmerman, R. S.↗

Cryogenic wind tunnels. II

The application of the cryogenic concept to various types of tunnels including Ludwieg tube tunnel, Evans clean tunnel, blowdown, induced-flow, and continuous-flow fan-driven tunnels is discussed. Benefits related to construction and operating costs are covered, along with benefits related to new testing capabilities. It is noted that cooling the test gas to very low temperatures increases Reynolds number by more than a factor of seven. From the energy standpoint, ambient-temperature fan-driven closed-return tunnels are considered to be the most efficient type of tunnel, while a large reduction in the required tunnel stagnation pressure can be achieved through cryogenic operation. Operating envelopes for three modes of operation for a cryogenic transonic pressure tunnel with a 2.5 by 2.5 test section are outlined. A computer program for calculating flow parameters and power requirements for wind tunnels with operating temperatures from saturation to above ambient is highlighted.

Kilgore, Robert A.↗

Ice Cloud Formation and Dehydration in the Tropical Tropopause Layer

Stratospheric water vapor is important not only for its greenhouse forcing, but also because it plays a significant role in stratospheric chemistry. several recent studies have focused on the potential for dehydration due to ice cloud formation in air rising slowly through the tropical tropopause layer. Holton and Gettelman showed that temperature variations associated with horizontal transport of air in the tropopause layer can drive ice cloud formation and dehydration, and Gettelman et al. recently examined the cloud formation and dehydration along kinematic trajectories using simple assumptions about the cloud properties. In this study, we use a Lagrangian, one-dimensional cloud model to further investigate cloud formation and dehydration as air is transported horizontally and vertically through the tropical tropopause layer. Time-height curtains of temperature are extracted from meteorological analyses. The model tracks the growth and sedimentation of individual cloud particles. The regional distribution of clouds simulated in the model is comparable to the subvisible cirrus distribution indicated by SAGE II. The simulated cloud properties depend strongly on the assumed ice supersaturation threshold for ice nucleation. with effective nuclei present (low supersaturation threshold), ice number densities are high (0.1--10 cm(circumflex)-3), and ice crystals do not grow large enough to fall very far, resulting in limited dehydration. With higher supersaturation thresholds, ice number densities are much lower (less than 0.01 cm(circumflex)-3), and ice crystals grow large enough to fall substantially; however, supersaturated air often crosses the tropopause without cloud formation. The clouds typically do not dehydrate the air along trajectories down to the temperature minimum saturation mixing ratio. Rather the water vapor mixing ratio crossing the tropopause along trajectories is typically 10-50% larger than the saturation mixing ratio.

Jensen, Eric↗

Ice Cloud Formation and Dehydration in the Tropical Tropopause Layer

Stratospheric water vapor is important not only for its greenhouse forcing, but also because it plays a significant role in stratospheric chemistry. Several recent studies have focused on the potential for dehydration due to ice cloud formation in air rising slowly through the tropical tropopause layer (TTL). Holton and Gettelman showed that temperature variations associated with horizontal transport of air in the TTL can drive ice cloud formation and dehydration, and Gettelman et al. recently examined the cloud formation and dehydration along kinematic trajectories using simple assumptions about the cloud properties. In this study, a Lagrangian, one-dimensional cloud model has been used to further investigate cloud formation and dehydration as air is transported horizontally and vertically through the TTL. Time-height curtains of temperature are extracted from meteorological analyses. The model tracks the growth, advection, and sedimentation of individual cloud particles. The regional distribution of clouds simulated in the model is comparable to the subvisible cirrus distribution indicated by SAGE II. The simulated cloud properties and cloud frequencies depend strongly on the assumed supersaturation threshold for ice nucleation. The clouds typically do not dehydrate the air along trajectories down to the temperature minimum saturation mixing ratio. Rather the water vapor mixing ratio crossing the tropopause along trajectories is 10-50% larger than the saturation mixing ratio. I will also discuss the impacts of Kelvin waves and gravity waves on cloud properties and dehydration efficiency. These simulations can be used to determine whether observed lower stratospheric water vapor mixing ratios can be explained by dehydration associated with in situ TTL cloud formation alone.

Jensen, Eric↗

High Electron Mobility SiGe/Si Transistor Structures on Sapphire Substrates

SiGe/Si n-type modulation doped field effect structures and transistors (n-MODFETs) have been fabricated on r-plane sapphire substrates. The structures were deposited using molecular beam epitaxy, and antimony dopants were incorporated via a delta doping process. Secondary ion mass spectroscopy (SIMS) indicates that the peak antimony, concentration was approximately 4 x 10(exp19) per cubic cm. The electron mobility was over 1,200 and 13,000 sq cm/V-sec at room temperature and 0.25 K, respectively. At these two temperatures, the electron carrier densities were 1.6 and 1.33 x 10(exp 12) per sq cm, thus demonstrating that carrier confinement was excellent. Shubnikov-de Haas oscillations were observed at 0.25 K, thus confirming the two-dimensional nature of the carriers. Transistors, with gate lengths varying from 1 micron to 5 microns, were fabricated using these structures and dc characterization was performed at room temperature. The saturated drain current region extended over a wide source-to-drain voltage (V(sub DS)) range, with (V(sub DS)) knee voltages of approximately 0.5 V and increased leakage starting at voltages slightly higher than 4 V.

Alterovitz, Samuel A.↗

High Electron Mobility SiGe/Si Transistor Structures on Sapphire Substrates

SiGe/Si n-type modulation doped field effect structures and transistors (n-MODFETs) have been fabricated on r-plane sapphire substrates. The structures were deposited using molecular beam epitaxy, and antimony dopants were incorporated via a delta doping process. Secondary ion mass spectroscopy (SIMS) indicates that the peak antimony concentration was approximately 4 x 10(exp 19) per cubic centimeter. At these two temperatures, the electron carrier densities were 1.6 and 1.33 x 10(exp 12) per square centimeter, thus demonstrating that carrier confinement was excellent. Shubnikov-de Haas oscillations were observed at 0.25 K, thus confirming the two-dimensional nature of the carriers. Transistors, with gate lengths varying from 1 micron to 5 microns, were fabricated using these structures and dc characterization was performed at room temperature. The saturated drain current region extended over a wide source-to-drain voltage (V (sub DS)) range, with V (sub DS) knee voltages of approximately 0.5 V and increased leakage starting at voltages slightly higher than 4 V.

Alterovitz, Samuel A.↗

Dynamics and Thermodynamics of Dense and Dilute Clusters of Drops

Collective drop behavior is encountered in sprays produced for a variety of applications. The existence of clusters of drops indicates that the interaction among the drops is important in determining the dynamics of the drops because the drop proximity changes the flow around the individual drops in a way that affects the drag on each drop. Additionally, if there is a phase change between the liquid drops and the gaseous surroundings (either evaporation or condensation), this will also influence the flow around the individual drops; and phase change is also affected by the drop proximity. What will be discussed are studies of collections of drops where the dynamics and thermodynamics of the drops are coupled. This means the modification of the drag force due to the drop number density, the evaporation rate and the slip velocity are all taken into account. In turn, the enhancement in the evaporation rate due to the slip velocity , and the hindering of evaporation due to the drop proximity are also part of the models.

thermodynamics↗

Outgassing Characterization of Common Trash Items for Disposal By Nanoracks Airlock on the International Space Station

The arrival of the Nanoracks Airlock to the International Space Station (ISS) has provided the ISS program the capability to dispose of common trash items. The concept of operations involved the crew bagging up those items into a trash bag and then utilizing the robotic arm and the airlock to jettison the trash bag. Because of the unknown thermal vacuum stability of some of the items, a molecular contamination concern was raised by the ISS program as the trash is exposed to vacuum upon the evacuation of air from the airlock and the robotic arm moving the airlock to its jettison location. In order to characterize the representative outgassing rates for ISS trash, thermal vacuum testing was performed at White Sands Test Facility. Trash was sorted into a “lower” outgassing bag and a “mixed” bag. The “mixed” trash bag contained more items that were suspected to be not vacuum stable. Load cells were chosen as the primary means for measuring mass loss. A sharp decay in the outgassing rate was observed in the first 30 minutes followed by a slower decay. As expected, the “mixed” bag lost more mass. While Quartz Crystal Microbalances (QCMs) are often utilized to measure long term outgassing rates and the sticking coefficients of contaminants at different operating temperatures for vacuum stable materials, these measurements proved difficult due to the amount and the inclusion of materials with suspect thermal vacuum stability. Because of high rates of material outgassing, the facility was unable to maintain the CQCM temperature setpoint of 80 K QCMs.. The QCMs operating at the warmer temperatures also saturated on occasion due to high levels of condensed matter. Though testing was able to confirm high risk of outgassing contamination for the program, true sticking coefficients could not be determined, available measurements are provided herein.

Alvin Y Huang↗

Thermomagnetic analysis of meteorites. III - C3 and C4 chondrites

Results are presented for thermomagnetic analysis in a controlled oxygen atmosphere of samples from thirteen C3 chondrites and two C4 chondrites. The examined meteorites are found to have rather diverse thermomagnetic properties, so they are placed into three groups on the basis of their thermomagnetic behavior and magnetic mineralogy: (1) those possibly containing magnetite before heating, but which display a large increase in saturation moment upon cooling to room temperature; (2) those containing magnetite as their major magnetic phase, but which show little change in saturation moment following the heating-cooling cycle; and (3) those which contain iron metal in addition to other magnetic phases. Upper limits are placed on the magnetite content of the five meteorites in group 1 by assuming that the initial saturation moment is due entirely to magnetite, and quantitative estimates of the magnetite content of the four meteorites in group 2 are determined from ambient-temperature saturation magnetization measurements. The data for the six meteorites in group 3 are discussed in terms of nickel content and troilite oxidation. It is concluded that since the magnetic and bulk mineralogies of carbonaceous chondrites are more varied and complex than indicated by whole-rock elemental analyses, the origin of such meteorites cannot be described by a simple model.

Herndon, J. M.↗