Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Application of Different X-ray Techniques to Improve In-Service Carbon Fiber Reinforced Rope Inspection

Carbon fiber reinforced polymer ropes are gaining in significance in the fields of civil engineering and hoisting applications. Thus, methods of non-destructive testing (NDT) need to be developed and evaluated with respect to new challenges and types of defects. Particularly important is the development of in-service testing solutions which allow the integration in global online monitoring systems. Conventional methods like electrical resistivity or strain measurements using optical fibers are already in use. This study investigates the possibility of using various X-ray techniques to increase the reliability and significance of NDT and their applicability to in-service testing. Conventional film radiography is the most common technique; however, even after image enhancement of the digitized film, this technique lacks contrast sensitivity and dynamic range compared to digital detector array (DDA) radiography. The DDA radiography is a highly sensitive method; yet, the limitation is that it delivers 2D images of 3D objects. By the use of co-planar translational laminography the detectability of planar defects is superior to 2D methods due to multiple projection angles. Apart from this, it can be used on-site due to a rather simple setup and robust equipment. In this work two photon counting detectors (PCD) with different sensor materials (Si and CdTe) were used. The results show that the resolution and defect recognition is lower in case of DDA radiography and laminography using PCDs compared to high-resolution computed tomography. However, the DDA radiography and laminography are sensitive enough to both fiber breakage and delaminations and can be significantly advantageous in terms of measurement time and adaptability for on-site monitoring.

42 ENGINEERING↗

Ionization Dynamics versus Laser Intensity in Laser-Driven Multiply Charged Ions

A sensitive method is put forward to determine the intensity of ultrastrong and short laser pulses via multiply charged ions. For guiding this experimentally challenging task, the laser-induced dynamics of these ions is calculated using both the classical relativistic and quantum Dirac equations. The resulting ionization yields and angular distributions are then evaluated to most sensitively deduce the applied maximal laser pulse intensity.

43 PARTICLE ACCELERATORS↗

Preparation and Characterization of Au-ZrO2-SiO2 Nanocomposite Spheres and Their Application in Enrichment and Detection of Organophosphorus Agents

Au-ZrO{sub 2}-SiO{sub 2} nanocomposite spheres were synthesized and used as selective sorbents for the solid-phase extraction (SPE) of orananophosphorous agents. A non-enzymatic electrochemical sensor based on an Au-ZrO{sub 2}-SiO{sub 2} modified electrode was developed for selective detection of orananophosphorous pesticides (OPs). The Au-ZrO{sub 2}-SiO{sub 2} nanocomposite spheres were synthesized by hydrolysis and condensation of zirconia n-butoxide (TBOZ) on the surface of SiO{sub 2} spheres and then introduction of gold nanoparticles on the surface. Transmission electron microscope and X-ray photoelectron spectroscopy were performed to characterize the formation of the nanocomposite sphere. Fast extraction of OP was achieved by Au-ZrO{sub 2}-SiO{sub 2} modified electrode within 5 min via the specific affinity between zirconia and phosphoric group. The assay yields a broad concentration range of paraoxon-ethyl from 1.0 to 500 ng/mL{sup -1} with a detection limit 0.5 ng/mL{sup -1}. This selective and sensitive method holds great promise for the enrichment and detection of OPs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Systematic Assessment of Retrieval Methods for Canopy Far-Red Solar-Induced Chlorophyll Fluorescence Using High-Frequency Automated Field Spectroscopy

Remote sensing of solar-induced chlorophyll fluorescence (SIF) offers potential to infer photosynthesis across scales and biomes. Many retrieval methods have been developed to estimate top-of-canopy SIF using ground-based spectroscopy. However, inconsistencies among methods may confound interpretation of SIF dynamics, eco-physiological/environmental drivers, and its relationship with photosynthesis. Using high temporal- and spectral resolution ground-based spectroscopy, we aimed to (1) evaluate performance of SIF retrieval methods under diverse sky conditions using continuous field measurements; (2) assess method sensitivity to fluctuating light, reflectance, and fluorescence emission spectra; and (3) inform users for optimal ground-based SIF retrieval. Analysis included field measurements from bi-hemispherical and hemispherical-conical systems and synthetic upwelling radiance constructed from measured downwelling radiance, simulated reflectance, and simulated fluorescence for benchmarking. Fraunhofer-based differential optical absorption spectroscopy (DOAS) and singular vector decomposition (SVD) retrievals exhibit convergent SIF-PAR relationships and diurnal consistency across different sky conditions, while O2A-based spectral fitting method (SFM), SVD, and modified Fraunhofer line discrimination (3FLD) exhibit divergent SIF-PAR relationships across sky conditions. We find that such behavior holds across system configurations, though hemispherical-conical systems diverge less across sky conditions. O 2 A retrieval accuracy, influenced by atmospheric distortion, improves with a narrower fitting window and when training SVD with temporally local spectra. This may impact SIF-photosynthesis relationships interpreted by previous studies using O 2 A-based retrievals with standard (759–767.76 nm) fitting windows. Fraunhofer-based retrievals resist atmospheric impacts but are noisier and more sensitive to assumed SIF spectral shape than O 2 A-based retrievals. We recommend SVD or SFM using reduced fitting window (759.5–761.5 nm) for robust far-red SIF retrievals across sky conditions.

59 BASIC BIOLOGICAL SCIENCES↗

X-ray diffraction and X-ray standing-wave study of the lead stearate film structure

A new approach to the study of the structural quality of crystals is proposed. It is based on the use of X-ray standing-wave method without measuring secondary processes and considers the multiwave interaction of diffraction reflections corresponding to different harmonics of the same crystallographic reflection. A theory of multiwave X-ray diffraction is developed to calculate the rocking curves in the X-ray diffraction scheme under consideration for a long-period quasi-one-dimensional crystal. This phase-sensitive method is used to study the structure of a multilayer lead stearate film on a silicon substrate. Some specific structural features are revealed for the surface layer of the thin film, which are most likely due to the tilt of the upper layer molecules with respect to the external normal to the film surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Utilizing fluorescent life time imaging microscopy technology for identify carriers of BRCA2 mutation

Worldwide, more than one million women are diagnosed with breast cancer every year, making it the most common female malignancy in the developed world. Germline mutations in BRCA1 and BRCA2 genes are estimated to increase the risk for developing breast cancer by up to 87%. From a clinical point of view, identification of BRCA1 and BRCA2 mutation carriers offers an opportunity to early identify or prevent the development of malignancy; therefore the ability to determine which women are more likely to carry BRCA1 or BRCA2 mutations is of great importance. The available diagnostic tests for mutation analysis of BRCA1 and BRCA2 are time- and labor-intensive, expensive, and do not allow the identification of all the functional mutations. We utilized the Fluorescent lifetime (FLT) imaging microscopy method which allows recognizing different cell populations, in order to distinguish between lymphocytes from BRCA1 and BRCA2 mutation carriers and non-carrier women by using easily obtainable lymphocyte cells from peripheral blood. Our results demonstrate that cells originated from BRCA2-mutation carriers have significantly lower FLT values compared with BRCA1 mutation carriers and control cells. This simple, inexpensive and sensitive method may be utilized in the future to detect BRCA2 mutation carriers, particularly those bearing unknown functional mutations. - Highlights: • Fluorescent lifetime imaging microscopy (FLIM) technology can be used for recognizing BRCA mutation carriers. • Cells originated from BRCA2-mutation carriers have lower FLT values compared with BRCA1 mutation carriers and control cells. • The difference in FLT values were observed regardless irradiation. • FLIM method may be more informative in the detection of BRCA2-mutation carriers than BRCA1.

60 APPLIED LIFE SCIENCES↗

Disentangling x-ray dichroism and birefringence via high-purity polarimetry

High-brilliance synchrotron radiation sources have opened new avenues for x-ray polarization analysis that go far beyond conventional polarimetry in the optical domain. With linear x-ray polarizers in a crossed setting, polarization extinction ratios down to 10 -10 can be achieved. This renders the method sensitive to probe the tiniest optical anisotropies that would occur, for example, in strong-field quantum electrodynamics due to vacuum birefringence and dichroism. Here we show that high-purity polarimetry can be employed to reveal electronic anisotropies in condensed matter systems with utmost sensitivity and spectral resolution. Taking CuO and La 2 CuO 4 as benchmark systems, we present a full characterization of the polarization changes across the Cu K-absorption edge and their separation into dichroic and birefringent contributions. At diffraction-limited synchrotron radiation sources and x-ray lasers, where polarization extinction ratios of 10 -12 can be achieved, our method has the potential to assess birefringence and dichroism of the quantum vacuum in extreme electromagnetic fields.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of vacuum pressure with a magneto-optical trap: A pressure-rise method

The lifetime of an atom trap is often limited by the presence of residual background gases in the vacuum chamber. This leads to the lifetime being inversely proportional to the pressure. Here, we use this dependence to estimate the pressure and to obtain pressure rate-of-rise curves, which are commonly used in vacuum science to evaluate the performance of a system. We observe different rates of pressure increase in response to different levels of outgassing in our system. Therefore, we suggest that this is a sensitive method which will find useful applications in cold atom systems, in particular, where the inclusion of a standard vacuum gauge is impractical.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing ligand removal and ordering at quantum dot surfaces using vibrational sum frequency generation spectroscopy

Controlling nanomaterial interfaces for emerging technologies has driven the need to understand the molecular species located there; however, challenges arise using traditional analytical techniques to directly characterize the molecular structure and local environments of these interfacial species due to their low relative populations. We hypothesized that vibrational sum frequency generation (vSFG) spectroscopy would be uniquely sensitive to the chemical modification of nanoparticle surfaces that is obscured using traditional bulk sensitive methods. Octadecylamine ligands were removed from model CdSe quantum dot surfaces using a common precipitation-resuspension procedure with polar protic and aprotic nonsolvents. Vibrational spectra of the ligands at the surface were collected with vSFG to directly probe the ligand ordering and coverage. Photoluminescence (PL), optical absorption, NMR, and mass spectrometry measurements were conducted for comparison. vSFG was found to be sensitive to subtle changes in ligand disorder over multiple precipitation-resuspension washes, and a limit to the number of ligand molecules removed from the surface and subsequent amount of disorder introduced to their packing was clearly observed. As a result, we also find that nonsolvents do not remain associated with the surface after washing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of XPS to Quantify Thickness of Coatings on Nanoparticles

XPS and other surface sensitive methods are being increasingly used to extract quantitative information about organic and inorganic coatings and contamination on nanoparticles. The extraction of coating thickness information requires combining known information about particle diameter from other measurements, such as electron microscopy, combined with a model that includes the physical processes associated with XPS, including electron path lengths, and particle geometry. Advantages of using XPS include the sensitivity to very thin coatings (or surface contamination) and the abillity to extract important information about organic layers. Single particle information from electron microsocpy combined XPS sensitivity to determine an average coating structure and composition make a powerful combination for nanoparticle anlaysis.

Environmental Molecular Sciences Laboratory↗

Electrochemical assay of active prostate-specific antigen (PSA) using ferrocene-functionalized peptide probes

This paper presents a novel approach to electrochemically determine enzymatically active PSA using ferrocene-functionalized helix peptide (CHSSLKQK). The principle of electrochemical measurement is based on the specific proteolytic cleavage events of the FC-peptide on the gold electrode surface in the presence of PSA, resulting the change of the current signal of the electrode. The percentage of the decreased current is linear with the concentration of active PSA at the range of 0.5-40 ng/mL with a detection limit of 0.2 ng/mL. The direct transduction of peptide cleavage events into an electrical signal provides a simple, sensitive method for detecting the enzymatic activity of PSA and determining the active PSA concentration.

60 APPLIED LIFE SCIENCES↗

Direct Spectrophotometric Analysis of Cr(VI) Using a Liquid Waveguide Capillary Cell

A simple and sensitive method for was developed and evaluated for determination of hexavalent chromium Cr(VI) in the environmental water samples. Cr(VI) is a notorious ground water contaminant toxic for humans and animals, and assessment of an exposure risk for aquatic receptors necessitates frequent Cr(VI) concentration data from a range of surface and groundwater locations. In this work we demonstrated, that enhanced UV-vis spectroscopy using Liquid Waveguide Capillary Cell (LWCC) offered an easy-to-use and economical methodology for the determination of chromate anion CrO42- in the natural waters under field conditions without chemical pretreatment. Direct determination of CrO42- in the groundwater and surface water (Columbia River) samples was achieved by measuring the chromate optical absorbance at 372 nm. A quantitative relationship between intensity of the absorbance signal and water pH allowing straight forward calculation of total Cr(VI) content in natural water was obtained. For a 100 cm pathlength LWCC, the detection limit for chromate in Columbia River water was found to be as low as 0.073 ppb. The described method is applicable for the in-field monitoring of Cr(VI) in the environmental waters at trace levels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visualizing the Three-Dimensional Arrangement of Hydrogen Atoms in Organic Molecules by Coulomb Explosion Imaging

Structure-sensitive methods based on femtosecond light or electron pulses are now making it possible to measure how molecular structures change during light-induced processes. Despite significant progress, high-fidelity imaging of nuclear positions remains a challenge even for relatively small molecular systems and, notably, regarding the positions of hydrogen atoms. As demonstrated in recent work, X-ray-induced Coulomb explosion imaging (CEI) may overcome this obstacle, as its sensitivity does not depend on the mass of the imaged atoms. The photoinduced ring opening of the heterocyclic molecule 2(5 H )-thiophenone has attracted recent interest. Here, in this work, we show that CEI offers a powerful route to imaging the peripheral H atoms in this molecule and thus, more generally, to tracking detailed nuclear motions (e.g., isomerizations) in organic molecules on ultrafast time scales. Specifically, we record momentum-space Coulomb explosion images that report on the three-dimensional positioning of all nuclei within the molecule, for instance, distinguishing H atoms in C–H bonds that lie within or are directed out of the plane defined by the heavy atoms. The prospect of imaging peripheral H atoms to probe photochemical dynamics is explored by coupling ab initio molecular dynamics with classical Coulomb explosion simulations, thereby differentiating potential photoproduct isomers, including those whose structures primarily differ in the position of the hydrogens.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Progress in the development of phase-sensitive neutron reflectometry methods.

It has been a number of years since phase-sensitive specular neutron reflectometry (PSNR) methods employing reference layers were first introduced to help remove the ambiguity inherent in the reconstruction of scattering length density (SLD) depth profiles (Majkrzak, C. F.; Berk, N. F. Physica B 2003, 336, 27) from specular reflectivity measurements. Although a number of scientific applications of PSNR techniques have now been successfully realized (Majkrzak, C. F.; Berk, N. F.; Perez-Salas, U. A. Langmuir 2003, 19, 7796 and references therein), in certain cases practical difficulties remain. In this article, we describe possible solutions to two specific problems: (1) the need for explicit, detailed knowledge of the SLD profile of a given reference layer of finite thickness; and (2) for a reference layer of finite thickness in which only two density variations are possible, how to identify which of two mathematical solutions corresponds to the true physical structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rapid Detection and Identification of a Pathogen's DNA Using Phi29 DNA Polymerase

Zoonotic pathogens including those transmitted by insect vectors are some of the most deadly of all infectious diseases known to mankind. A number of these agents have been further weaponized and are widely recognized as being potentially significant biothreat agents. We describe a novel method based on multiply-primed rolling circle in vitro amplification for profiling genomic DNAs to permit rapid, cultivation-free differential detection and identification of circular plasmids in infectious agents. Using Phi29 DNA polymerase and a two-step priming reaction we could reproducibly detect and characterize by DNA sequencing circular DNA from Borrelia burgdorferi B31 in DNA samples containing as little as 25 pg of Borrelia DNA amongst a vast excess of human DNA. This simple technology can ultimately be adapted as a sensitive method to detect specific DNA from both known and unknown pathogens in a wide variety of complex environments.

59 BASIC BIOLOGICAL SCIENCES↗

Non-targeted discovery-based analysis for gas chromatography with mass spectrometry: A comparison of peak table, tile, and pixel-based Fisher ratio analysis

The ability to discover minute differences between samples or sample classes for gas chromatography coupled to mass spectrometry (GC-MS) can be a challenging endeavor, especially when those differences are not a priori . Fisher ratio (F-ratio) analysis is an apt technique to probe the differences between GC-MS chromatograms. F-ratio analysis is a supervised, non-targeted, discovery-based method that compares two different samples (or sample classes) to reduce the GC-MS dataset into a hit list composed of class distinguishing compounds. Three different F-ratio techniques, peak table, tile, and pixel-based were used to “discover” nine non-native analytes that were spiked into gasoline at four different nominal concentrations of 250, 85, 25, 5 parts-per-million (ppm). For the tile and pixel-based F-ratio calculations, a novel methodology is introduced to improve the sensitivity of the F-ratio calculations while reducing false positives. Furthermore, we use a combinatorial technique using null class comparisons, termed null distribution analysis, to determine a statistical F-ratio cutoff for analysis of the hit lists. The pixel-based algorithm was the most sensitive method and was able to “discover” all nine spiked analytes at a nominal concentration of 250 ppm albeit with one false positive interspersed towards the bottom of the hit list. The pixel-based software was also able to “discover” more of the spiked analytes at the lower concentrations with seven of the spiked analytes “discovered” at 85 ppm, four of the spiked analytes “discovered” at 25 ppm, and one analyte “discovered” at 5 ppm.

47 OTHER INSTRUMENTATION↗

Off-resonant detection of domain wall oscillations using deterministically placed nanodiamonds

Abstract Nitrogen-vacancy (NV) centers in diamond offer a sensitive method of measuring the spatially localized dynamics of magnetization and associated spin textures in ferromagnetic materials. We use NV centers in a deterministically positioned nanodiamond to demonstrate off-resonant detection of microwave field-driven GHz-scale oscillations of a single domain wall (DW). The technique exploits the enhanced relaxation of NV center spins due to the broadband stray field noise generated by an oscillating DW pinned at an engineered defect in a lithographically patterned ferromagnetic nanowire. Discrepancies between the observed DW oscillation frequency and predictions from micromagnetic simulations suggest extreme sensitivity of DW dynamics to patterning imperfections such as edge roughness. These experiments and simulations identify potential pathways toward quantum spintronic devices that exploit current-driven DWs as nanoscale microwave generators for qubit control, greatly increasing the driving field at an NV center and thus drastically reducing the π pulse time.

Rable, Jeffrey↗

Sensitivity analysis of large system of chemical kinetic parameters for engine combustion simulation

In this study, the authors applied the state-of-the art sensitivity methods to downselect system parameters from 4000+ to 8, (23000+ -> 4000+ -> 84 -> 8). This analysis procedure paves the way for future works: (1) calibrate the system response using existed experimental observations, and (2) predict future experiment results, using the calibrated system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗