Search NASA⌕ Search

SEARCH · Search NASA

Results for “shot noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Robust Design Under Uncertainty in Quantum Error Mitigation

Error mitigation techniques are crucial to achieving near-term quantum advantage. Classical postprocessing of quantum computation outcomes is a popular approach for error mitigation, which includes methods, such as zero noise extrapolation, virtual distillation, and learning-based error mitigation. However, these techniques have limitations due to the propagation of uncertainty resulting from the finite shot number of a quantum measurement. In this work, we introduce general and unbiased methods for quantifying the uncertainty and error of error-mitigated observables based on the strategic sampling of error mitigation outcomes. We then extend our approach to demonstrate the optimization of performance and robustness of error mitigation under uncertainty. To illustrate our methods, we apply them to zero noise extrapolation and Clifford date regression in the ground state of the XY model simulated using depolarizing and International Business Machines Corporation (IBM) Toronto noise models, respectively. In particular, we optimize the choice of noise levels and the allocation of shots for zero noise extrapolation and the distribution of the training circuits for Clifford data regression. While our methods are readily applicable to any postprocessing-based error mitigation approach, in practice they must not be prohibitively expensive—even though they perform optimizations of the error mitigation hyperparameters requiring sampling of a statistical distribution of error mitigation outcomes. By leveraging surrogate-based optimization, we show that our methods can efficiently perform optimal design for a zero noise extrapolation implementation. We then further demonstrate the transferability of learned zero noise extrapolation hyperparameters to other similar circuits.

97 MATHEMATICS AND COMPUTING↗

Contextual subspace variational quantum eigensolver calculation of the dissociation curve of molecular nitrogen on a superconducting quantum computer

Abstract We present an experimental demonstration of the Contextual Subspace Variational Quantum Eigensolver on superconducting hardware. Calculating the potential energy curve of molecular nitrogen proves challenging for many conventional quantum chemistry techniques, since static correlation dominates in the dissociation limit. Our quantum simulations retain good agreement with the Full Configuration Interaction energy, outperforming all benchmarked single-reference wavefunction techniques in capturing the bond-breaking appropriately. Moreover, our methodology is competitive with multiconfigurational approaches but at a saving of quantum resource, meaning larger active spaces can be treated for a fixed qubit allowance. To achieve this result, we deploy an error mitigation/suppression strategy comprised of Dynamical Decoupling, Measurement-Error Mitigation and Zero-Noise Extrapolation. Circuit parallelization also provides passive noise-averaging and improves the effective shot yield to reduce the measurement overhead. Furthermore, we introduce a modified adaptive ansatz construction algorithm that incorporates hardware awareness into our variational circuits, minimizing the transpilation cost for the target qubit topology.

Physics↗

X-ray-line coincidence photopumping in a potassium-chlorine mixed plasma

Exploiting the multiple long pulse capability and suite of x-ray diagnostics of the Orion laser, we have set out to explore line coincidence photopuming—the enhancement in population of an atomic level brought on by resonant absorption of x rays from a different emitting ion. Unlike previous work, the two ions are in the same plasma and so the experiment is an x-ray analog of the well-known Bowen resonance fluorescence mechanism that operates in astrophysical situations in the optical region. Herein, our measurements have shown enhanced fluorescence in a chlorine plasma, attributable to line coincident photopumping from co-mixed potassium ions. To detect this relatively low signal-to-noise phenomenon, the data from multiple shots are combined, and the statistical method of bootstrapping is used to assign a confidence value to the measured enhancement, resulting in an estimate of the enhancement of 39 ± 18 16 % compared to the null case, where no pumping occurs. The experimental results have been compared to coupled radiation-transport and radiation hydrodynamics simulations using the CRETIN code together with the NYM radiation hydrodynamics model and agreement has been found, with the simulations also predicting modest enhancement.

74 ATOMIC AND MOLECULAR PHYSICS↗

Persistent, “Mysterious” Seismoacoustic Signals Reported in Oklahoma State during 2019

Here, we report on the source of seismoacoustic pulses that were observed across the state of Oklahoma (OK) during summer of 2019, and the subject of national media coverage and speculation. Seismic network data collected across four U.S. states and interviews with witnesses to the pulse’s effect on residential structures demonstrate that they were triggered by routine ammunition disposal operations conducted by McAlester Army Ammunition Plant (McAAP). During these operations, conventional explosives destroy obsolete munitions stored in pits through a controlled sequence of electronically timed shots that occur over tens of minutes. Despite noise-abatement efforts that reduce coupling of acoustic energy with air, some lower frequency, subaudible (infrasonic) sound radiates from these shots as discrete pulses. We use nine months of blast log documents, seismic network records, analyst picks, and physical modeling to demonstrate that seismic stations as far as 640 km from McAAP sample these pulses, which record seasonal patterns in stratospheric and tropospheric winds, as well as the dynamic formation of waveguides and shadow zones. Digital short-term average to long-term average detectors that we augment with dynamic thresholds and time-binning operations identify these pulses with a fair probability, when compared with visual observations. Our analyses thereby provide estimates of observation rates for both partial and full sequences of these pulses, as well as single shots. We suggest that disposal operations can exploit existing, composite seismic networks to predict where residents are likely to witness blasting. Crucially, our data also show that dense seismic networks can record multiscale atmospheric processes in the absence of infrasound arrays.

58 GEOSCIENCES↗

More buck-per-shot: Why learning trumps mitigation in noisy quantum sensing

Quantum sensing is one of the most promising applications for quantum technologies. However, reaching the ultimate sensitivities enabled by the laws of quantum mechanics can be a challenging task in realistic scenarios where noise is present. While several strategies have been proposed to deal with the detrimental effects of noise, these come at the cost of an extra shot budget. Given that shots are a precious resource for sensing – as infinite measurements could lead to infinite precision – care must be taken to truly guarantee that any shot not being used for sensing is actually leading to some metrological improvement. In this work, we study whether investing shots in error-mitigation, inference techniques, or combinations thereof, can improve the sensitivity of a noisy quantum sensor on a (shot) budget. We present a detailed bias–variance error analysis for various sensing protocols. Our results show that the costs of zero-noise extrapolation techniques outweigh their benefits. We also find that pre-characterizing a quantum sensor via inference techniques leads to the best performance, under the assumption that the sensor is sufficiently stable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rapid and flexible segmentation of electron microscopy data using few-shot machine learning

Abstract Automatic segmentation of key microstructural features in atomic-scale electron microscope images is critical to improved understanding of structure–property relationships in many important materials and chemical systems. However, the present paradigm involves time-intensive manual analysis that is inherently biased, error-prone, and unable to accommodate the large volumes of data produced by modern instrumentation. While more automated approaches have been proposed, many are not robust to a high variety of data, and do not generalize well to diverse microstructural features and material systems. Here, we present a flexible, semi-supervised few-shot machine learning approach for segmentation of scanning transmission electron microscopy images of three oxide material systems: (1) epitaxial heterostructures of SrTiO 3 /Ge, (2) La 0.8 Sr 0.2 FeO 3 thin films, and (3) MoO 3 nanoparticles. We demonstrate that the few-shot learning method is more robust against noise, more reconfigurable, and requires less data than conventional image analysis methods. This approach can enable rapid image classification and microstructural feature mapping needed for emerging high-throughput characterization and autonomous microscope platforms.

36 MATERIALS SCIENCE↗

Identification of Acoustic Wave Signatures in the Ionosphere From Conventional Surface Explosions Using MF/HF Doppler Sounding

Here, we present an experiment to detect one ton TNT-equivalent chemical explosions using pulsed Doppler radar observations of isodensity layers in the ionospheric E region during two campaigns. The first campaign, conducted on 15 October 2019, produced potential detections of all three shots. The detections closely resemble the temporal and spectral properties predicted using the InfraGA ray tracing and weakly nonlinear waveform propagation model. Here the model predicts that within 6.5–7.25 min of each shot a waveform peaking between 0.9 and 0.4 Hz will impact the ionosphere at 100 km. As the waves pass through this region, they will imprint their signal on an isodensity layer, which is detectable using a Doppler radar operating at the plasma frequency of the isodensity. Within the time windows of each of the three shots in the first campaign, we detect enhanced wave activity peaking near 0.5 Hz. These waves were imprinted on the Doppler signal probing an isodensity layer at 2.785 MHz near 100 km altitude. Despite these detections, the method appears to be unreliable as none of the six shots from the second campaign, conducted on 10 July 2020 were detected. The observations from this campaign were characterized by an increased acoustic noise environment in the microbarom band and persistent scintillation on the radar returns. These effects obscured any detectable signal from these shots and the baseline noise was well above the detection levels of the first campaign.

47 OTHER INSTRUMENTATION↗

Single-Shot Decoding of Good Quantum LDPC Codes

Abstract Quantum Tanner codes constitute a family of quantum low-density parity-check codes with good parameters, i.e., constant encoding rate and relative distance. In this article, we prove that quantum Tanner codes also facilitate single-shot quantum error correction (QEC) of adversarial noise, where one measurement round (consisting of constant-weight parity checks) suffices to perform reliable QEC even in the presence of measurement errors. We establish this result for both the sequential and parallel decoding algorithms introduced by Leverrier and Zémor. Furthermore, we show that in order to suppress errors over multiple repeated rounds of QEC, it suffices to run the parallel decoding algorithm for constant time in each round. Combined with good code parameters, the resulting constant-time overhead of QEC and robustness to (possibly time-correlated) adversarial noise make quantum Tanner codes alluring from the perspective of quantum fault-tolerant protocols.

97 MATHEMATICS AND COMPUTING↗

Comparative study of adaptive variational quantum eigensolvers for multi-orbital impurity models

Hybrid quantum-classical embedding methods for correlated materials simulations provide a path towards potential quantum advantage. However, the required quantum resources arising from the multi-band nature of d and f electron materials remain largely unexplored. Here we compare the performance of different variational quantum eigensolvers in ground state preparation for interacting multi-orbital embedding impurity models, which is the computationally most demanding step in quantum embedding theories. Focusing on adaptive algorithms and models with 8 spin-orbitals, we show that state preparation with fidelities better than 99.9% can be achieved using about 2 14 shots per measurement circuit. When including gate noise, we observe that parameter optimizations can still be performed if the two-qubit gate error lies below 10 -3 , which is slightly smaller than current hardware levels. Finally, we measure the ground state energy on IBM and Quantinuum hardware using a converged adaptive ansatz and obtain a relative error of 0.7%.

42 ENGINEERING↗

Impact Noise Monitoring for Gelled Water Mitigation Test Series - North Pad

This report represents the 1st shot (in a series of 8) conducted on September 15, 2022. One 10 lb C4 charge (along with ~200g of Potassium Bromide (KBr)) was detonated inside 9920 North Pad Boom Box. Noise sampling was performed at several points on Site 9920 to characterize the noise mitigation provided by the block structure. This data will help inform safe locations for Members of the Workforce (MOWs) to be located during future testing with similar net explosive weights. During the test, all MOW/site visitors were bunkered inside Building 9926/Mobile Firing Control Point (MFCP) to prevent personnel exposure to any hazards associated with the testing

42 ENGINEERING↗

External Radiation and Magnetic-Field Effects on the Coherence and Stability of Transmon Qubits

Superconducting transmon qubits are a central building block of modern quantum computing architectures, yet their coherence properties remain sensitive to external influences that can limit performance or introduce temporal instabilities. In this talk, I will discuss two experimental studies aimed at quantifying these effects. First, I will examine how ionizing radiation impacts qubit relaxation. Using the same transmon device operated at two locations with dramatically different radiation backgrounds—the above-ground SQMS facility at Fermilab (USA) and the deep-underground Gran Sasso Laboratory (Italy)—we observe a higher rate of radiation-induced decay events above ground, even though intrinsic noise remains the dominant source of single-shot errors. I will also discuss the detection efficiency of a radiation detector made using such a device. Second, I will present results on how small magnetic fields, applied either during cooldown or at millikelvin temperatures, influence device stability. We find that fixed-frequency transmons maintain robust coherence up to approximately 600 mG of trapped out-of-plane field, and that controlled application of magnetic field can reduce temporal fluctuations in T1. Together, these studies provide insight into how external environments shape transmon coherence and offer potential pathways for improving qubit stability in scalable quantum processors.

Roy, Tanay [Fermilab]↗

Unsupervised anomaly detection in MeV ultrafast electron diffraction

MeV ultrafast electron diffraction (MUED) is a pump-probe technique used to study the dynamic structural evolution of materials. An ultrashort laser pulse triggers structural changes, which are then probed by an ultrashort relativistic electron beam. To overcome low signal-to-noise ratios, diffraction patterns are averaged over thousands of shots. However, shot-to-shot instabilities in the electron beam can distort individual patterns, introducing uncertainty. Improving MUED accuracy requires detecting and removing these anomalous patterns from large datasets. In this work, we developed a fully unsupervised methodology for the detection of anomalous diffraction patterns. Using a convolutional autoencoder, we calculate the reconstruction mean squared error of the diffraction patterns. Based on the statistical analysis of this error, we provide the user an estimation of the probability that the pattern is normal, which also allows a posterior visual inspection of the images that are difficult to classify. This method has been trained with only 100 diffraction patterns and tested on 1521 patterns, resulting in a false positive rate between 0.2% and 0.4%, with a training time of 10 s per image and a test time of about 1 s per image. Here, the proposed methodology can also be applied to other diffraction techniques in which large datasets are collected that include faulty images due to instrumental instabilities.

43 PARTICLE ACCELERATORS↗

Proof-of-concept Talbot–Lau x-ray interferometry with a high-intensity, high-repetition-rate, laser-driven K-alpha source

Talbot–Lau x-ray interferometry is a grating-based phase-contrast technique, which enables measurement of refractive index changes in matter with micrometric spatial resolution. The technique has been established using a variety of hard x-ray sources, including synchrotron, free-electron lasers, and x-ray tubes, and could be used in the optical range for low-density plasmas. The tremendous development of table-top high-power lasers makes the use of high-intensity, laser-driven K-alpha sources appealing for Talbot–Lau interferometer applications in both high-energy-density plasma experiments and biological imaging. To this end, we present the first, to the best of our knowledge, feasibility study of Talbot–Lau phase-contrast imaging using a high-repetition-rate laser of moderate energy (100 mJ at a repetition rate of 10 Hz) to irradiate a copper backlighter foil. The results from up to 900 laser pulses were integrated to form interferometric images. A constant fringe contrast of 20% is demonstrated over 100 accumulations, while the signal-to-noise ratio continued to increase with the number of shots. Phase retrieval is demonstrated without prior ex-situ phase stepping. Instead, correlation matrices are used to compensate for the displacement between reference acquisition and the probing of a PMMA target rod. The steps for improved measurements with more energetic laser systems are discussed. The final results are in good agreement with the theoretically predicted outcomes, demonstrating the applicability of this diagnostic to a range of laser facilities for use across several disciplines.

Bouffetier, V. (ORCID:0000000160791260)↗

Scalable Parallel Measurement of Individual Nitrogen-Vacancy Centers

The nitrogen-vacancy (NV) center in diamond is a solid-state spin defect that has been widely adopted for quantum sensing and quantum information processing applications. Typically, experiments are performed either with a single isolated NV center or with an unresolved ensemble of many NV centers, resulting in a trade-off between measurement speed and spatial resolution or control over individual defects. In this work, we introduce an experimental platform that bypasses this trade-off by addressing multiple optically resolved NV centers in parallel. We perform charge- and spin-state manipulations selectively on multiple NV centers from within a larger set, and we manipulate and measure the electronic spin states of over 100 NV centers in parallel. We show that the high signal-to-noise ratio of the measurements enables the detection of shot-to-shot pairwise correlations between the spin states of 108 NV centers, corresponding to the simultaneous measurement of 5778 unique correlation coefficients. We discuss how our platform can be scaled to parallel experiments with thousands of individually resolved NV centers. These results enable parallelized high-throughput sensing experiments that retain the spatial resolution of single defects and will, thereby, help to unlock advances in applications such as single-molecule NMR and characterization of integrated circuits. In addition, our approach to multiplexing provides a natural platform for the application of recently developed correlated sensing techniques.

NV centers↗

Impulse Noise Sampling at 9965 - Armag

One detonation test was monitored for impulse noise at Thunder Range on November 6, 2020. The TNT equivalency for this shot was 100 lbs. Ground zero for this test was located at an open area of Range 7. The Armag, where MOW were remotely located, was just south of the east end of the TR shock tube The purpose of this sampling event was to characterize the noise attenuation provided by the Armag which will be used as the primary firing location in a future test series. To determine attenuation provided by the Armag, one sound level monitor was placed inside and a second monitor was placed outside the hardened structure at the same distance from ground zero. The Armag was located 1300 feet from ground zero. Essential personnel performing these tests were remotely located inside the Armag and wore hearing protection with a minimum NRR of 23. Members of the Workforce (MOW) who are exposed to noise levels above 140 dBC, regardless of hearing protection worn, are required to be enrolled into the SNL Hearing Conservation Program which includes audiometric testing, online training (HCP100) and wearing hearing protection.

42 ENGINEERING↗

Neutron calorimeter development at fission and fusion pulsed neutron sources

A neutron calorimeter fielded in pulsed neutron irradiation experiments at the National Ignition Facility (NIF) and White Sands Missile Range Fast Burst Reactor (WSMR FBR) is described, and results are provided and discussed. The calorimeter is modular in design to allow fielding of various neutron absorber materials and thicknesses, as well as use at both fission and fusion sources, all of which has been done. Neutron calorimeters designed for fission sources have been fielded at fusion sources as well, but these instances are not documented in available literature—making this work novel. The functional calorimeter consists of a neutron absorber and two sheathed, grounded thermocouples secured within a subassembly made of thermally insulating materials. This subassembly is placed into a sealed vessel for material and facility safety considerations. The device was fielded at NIF in four polar-direct-drive exploding pusher shots and eleven WSMR FBR pulses. Calorimeter data from NIF experiments show a discernable thermal response accredited to neutron heating within the first 10 s, but the data are dominated by noise from ambient X-ray heating after time = 10 s post-pulse. This response is highly consistent between shots and linearly related to incident neutron fluence and neutron absorber thickness. A temperature rise of 1.1E-2 K/(10 13 neutrons/cm 2 ) per millimeter of absorber thickness was determined for both 0.4 mm and 1 mm thick depleted uranium absorbers with linear best fit R 2 of 0.97 and 0.98 for each thickness and y-axis offsets of 8.8E-3 and 1.3E-2, respectively. WSMR FBR experiment data show a temperature rise of 6.2E-2 K/(10 13 neutrons/cm 2 ) with linear best fit R 2 of 0.14 and y-axis offset of 7.6E-3 for a calorimeter with a 1 mm thick enriched boron carbide ( 10 B 4 C) absorber, though it must be noted that device-to-device variability is significant at both facilities. So these data are also affected by noise on a similar timescale as at NIF, though the noise is significantly lesser in magnitude but oscillatory.

42 ENGINEERING↗

Visual Fixations in Basketball Shooting: Differences between Shooting Conditions

Basketball is a sport where shooting is one of the most important factors that determines the success or failure of the teams. Therefore, basketball players need to shoot the ball accurately. The present study aimed to evaluate whether different shooting conditions influence the visual behavior of athletes. For this, the Tobbi Pro Glasses 3 equipment was used to evaluate the time of the first fixation, the number of fixations, and the total time of fixations in the basket, during the shooting movement. Different distances to the basket, simulated gym audience noise, and shooting with opposition were considered. A group of 18 athletes with an average age of 22 ± 3.72 years and an average basketball practice experience of 12.5 ± 4.52 years performed 10 valid shots from different distances and different shooting angles, with different restrictions, namely, shooting with simulated opposition and gym audience noise. Statistically significant differences between shooting with opposition and baseline, in terms of the number of fixations and the total time of fixation, were found. Regarding shooting with gym audience noise, differences only occur for the total time of fixations in one position. Despite this, in all variables and positions, the values were lower in shooting with constraints compared to the baseline.

Amaro, Catarina M. (ORCID:0000000303343503)↗

Optimizing the sensitivity of high repetition rate broadband transient optical spectroscopy with modified shot-to-shot detection

A major limitation of transient optical spectroscopy is that relatively high laser fluences are required to enable broadband, multichannel detection with acceptable signal-to-noise levels. Under typical experimental conditions, many condensed phase and nanoscale materials exhibit fluence-dependent dynamics, including higher order effects such as carrier–carrier annihilation. With the proliferation of commercial laser systems, offering both high repetition rates and high pulse energies, have come new opportunities for high sensitivity pump-probe measurements at low pump fluences. However, experimental considerations needed to fully leverage the statistical advantage of these laser systems have not been fully described. Here, we demonstrate a high repetition rate, broadband transient spectrometer capable of multichannel shot-to-shot detection at 90 kHz. Importantly, we find that several high-speed cameras exhibit a time-domain fixed pattern noise resulting from interleaved analog-to-digital converters, which is particularly detrimental to the conventional “ON/OFF” modulation scheme used in pump-probe spectroscopy. Using a modified modulation and data processing scheme, we achieve a noise level of 10−5 in 4 s for differential transmission, an order of magnitude lower than for commercial 1 kHz transient spectrometers for the same acquisition time. We leverage the high sensitivity of this system to measure the differential transmission of monolayer graphene at low pump fluence. We show that signals on the order of 10−6 OD can be measured, enabling a new data acquisition regime for low-dimensional materials.

47 OTHER INSTRUMENTATION↗