Search NASA⌕ Search

SEARCH · Search NASA

Results for “single image velocity measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The Boot Lake MF imaging radar

The Middle-Atmosphere Imaging Radar is located at the Boot Lake field site, 10 miles east of Brighton, Colorado. It operates at 2.66 MHz with a 50-kW peak pulse power in 30 microsecond pulses. Ten independent coaxial-collinear antennas are used; five are parallel and run east-west, the other five are parallel and run north-south. Each antenna consists of eight half-wave dipoles. All ten antennas or a crossed pair may be used for transmission; all ten are sampled by pairs in rapid sequence for reception. The system is now operating on a campaign basis as a Fourier interferometer by measuring the complex voltages on the ten antennas and Fourier transforming them independently. Multiple scatterers within a single range gate, now sorted by velocity, can be located individually by their phase angles. The transmitted signal cycles through four modes (N-S linear, right-hand circular, E-W linear, and left-hand circular).

Adams, G. W.↗

Systematic Errors in Stereo PIV When Imaging through a Glass Window

This document assesses the magnitude of velocity measurement errors that may arise when performing stereo particle image velocimetry (PIV) with cameras viewing through thick, refractive window and where the calibration is performed in one plane only. The effect of the window is to introduce a refractive error that increases with window thickness and the camera angle of incidence. The calibration should be performed while viewing through the test section window, otherwise a potentially significant error may be introduced that affects each velocity component differently. However, even when the calibration is performed correctly, another error may arise during the stereo reconstruction if the perspective angle determined for each camera does not account for the displacement of the light rays as they refract through the thick window. Care should be exercised when applying in a single-plane calibration since certain implicit assumptions may in fact require conditions that are extremely difficult to meet in a practical laboratory environment. It is suggested that the effort expended to ensure this accuracy may be better expended in performing a more lengthy volumetric calibration procedure, which does not rely upon the assumptions implicit in the single plane method and avoids the need for the perspective angle to be calculated.

Green, Richard↗

Precision of FLEET Velocimetry Using High-Speed CMOS Camera Systems

Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 microseconds, precisions of 0.5 meters per second in air and 0.2 meters per second in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision HighSpeed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.

Peters, Christopher J.↗

Intracavity Rayleigh/Mie Scattering for Multipoint, Two-Component Velocity Measurement

A simultaneous multi-point two-component Doppler velocimeter is described. The system uses two optical cavities: a Fabry-Perot etalon and an optical cavity for collecting and re-circulating the Rayleigh/Mie scattered light that is collected from the measurement volume in two parallel, but opposite directions. Single-pulse measurements of two orthogonal components of the velocity vector in a supersonic free jet were performed to demonstrate the technique. The re-circulation of the light rejected by the interferometer input mirror also increased the signal intensity by a factor of 3.5. 2005 Optical Society of America Interferometric Rayleigh scattering has previously been used for single-point velocity measurements in unseeded gas flow. However, this past work has generally been limited to probing with continuous-wave lasers resulting in time-averaged measurements of velocity. Multiple velocity components have been measured simultaneously by separate instruments.1,2 It has also been demonstrated that two orthogonal velocity components can be measured simultaneously at one point using one interferometer by reflecting back the probing laser beam, although this approach results in directional ambiguity of the flow velocity vector.3 This measurement ambiguity was removed by prior knowledge of the approximate magnitude and sign of the velocity components. Furthermore, it was shown that multiple points could be measured simultaneously with a Rayleigh scattering interferometric approach, but only one component of velocity was measured.4 Another method of performing multiple component velocity measurements with Rayleigh scattering uses a pair of cameras to image the flow, one of which views the flow through an iodine gas filter. This iodine-filter technique has the advantage of allowing high-resolution velocity imaging, but it generally has a lower dynamic range.

Bivolaru, Daniel↗

Spectroscopy of the first resolved strongly lensed Type Ia supernova iPTF16geu

We report the results from spectroscopic observations of the multiple images of the strongly lensed Type Ia supernova (SN Ia), iPTF16geu, obtained with ground-based telescopes and the Hubble Space Telescope (HST). From a single epoch of slitless spectroscopy with HST, we resolve spectra of individual lensed supernova images for the first time. This allows us to perform an independent measurement of the time-delay between the two brightest images, Δt = 1.4 ± 5.0 d, which is consistent with the time-delay measured from the light curves. We also present measurements of narrow emission and absorption lines characterizing the interstellar medium in the SN Ia host galaxy at z = 0.4087, as well as in the foreground lensing galaxy at z = 0.2163. We detect strong Na ID absorption in the host galaxy, indicating that iPTF16geu belongs to a subclass of SNe Ia displaying ‘anomalously’ large Na ID column densities compared to dust extinction derived from light curves. For the lens galaxy, we refine the measurement of the velocity dispersion, σ = 129 ± 4 km/s, which significantly constrains the lens model. We use ground-based spectroscopy, boosted by a factor ∼70 from lensing magnification, to study the properties of a high-z SN Ia with unprecedented signal-to-noise ratio. The spectral properties of the supernova, such as pseudo-Equivalent widths of several absorption features and velocities of the Si II-line, indicate that iPTF16geu is a normal SN Ia. We do not detect any significant deviations of the SN spectral energy distribution from microlensing of the SN photosphere by stars and compact objects in the lensing galaxy.

J Johansson↗

Time-Resolved PIV for Space-Time Correlations in Hot Jets

Temporally Resolved Particle Image Velocimetry (TR-PIV) is being used to characterize the decay of turbulence in jet flows a critical element for understanding the acoustic properties of the flow. A TR-PIV system, developed in-house at the NASA Glenn Research Center, is capable of acquiring planar PIV image frame pairs at up to 10 kHz. The data reported here were collected at Mach numbers of 0.5 and 0.9 and at temperature ratios of 0.89 and 1.76. The field of view of the TR-PIV system covered 6 nozzle diameters along the lip line of the 50.8 mm diameter jet. The cold flow data at Mach 0.5 were compared with hotwire anemometry measurements in order to validate the new TR-PIV technique. The axial turbulence profiles measured across the shear layer using TR-PIV were thinner than those measured using hotwire anemometry and remained centered along the nozzle lip line. The collected TR-PIV data illustrate the differences in the single point statistical flow properties of cold and hot jet flows. The planar, time-resolved velocity records were then used to compute two-point space-time correlations of the flow at the Mach 0.9 flow condition. The TR-PIV results show that there are differences in the convective velocity and growth rate of the turbulent structures between cold and hot flows at the same Mach number.

Wernet, Mark P.↗

Time Resolved PIV for Space-Time Correlations in Hot Jets

Temporally Resolved Particle Image Velocimetry (TR-PIV) is the newest and most exciting tool recently developed to support our continuing efforts to characterize and improve our understanding of the decay of turbulence in jet flows -- a critical element for understanding the acoustic properties of the flow. A new TR-PIV system has been developed at the NASA Glenn Research Center which is capable of acquiring planar PIV image frame pairs at up to 25 kHz. The data reported here were collected at Mach numbers of 0.5 and 0.9 and at temperature ratios of 0.89 and 1.76. The field of view of the TR-PIV system covered 6 nozzle diameters along the lip line of the 50.8 mm diameter jet. The cold flow data at Mach 0.5 were compared with hotwire anemometry measurements in order to validate the new TR-PIV technique. The axial turbulence profiles measured across the shear layer using TR-PIV were thinner than those measured using hotwire anemometry and remained centered along the nozzle lip line. The collected TR-PIV data illustrate the differences in the single point statistical flow properties of cold and hot jet flows. The planar, time-resolved velocity records were then used to compute two-point space-time correlations of the flow at the Mach 0.9 flow condition. The TR-PIV results show that there are differences in the convective velocity and growth rate of the turbulent structures between cold and hot flows at the same Mach number

Wernet, Mark P.↗

Microcalorimeter measurement of x-ray spectra from a high-temperature magnetically confined plasma

A NASA-built x-ray microcalorimeter spectrometer has been installed on the MST facility at the Wisconsin Plasma Physics Laboratory and has recorded x-ray photons emitted by impurity ions of aluminum in a majority deuterium plasma. Much of the x-ray microcalorimeter development has been driven by the needs of astrophysics missions, where imaging arrays with few-eV spectral resolution are required. The goal of our project is to adapt these single-photon-counting microcalorimeters for magnetic fusion energy research and demonstrate the value of such measurements for fusion science. Microcalorimeter spectrometers combine the best characteristics of the x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and the broadband coverage of an x-ray pulse height analysis system. Fusion experiments are increasingly employing high-Z plasma-facing components and require measurement of the concentration of all impurity ion species in the plasma. This diagnostic has the capability to satisfy this need for multi-species impurity ion data and will also contribute to measurements of impurity ion temperature and flow velocity, Zeff, and electron density. Here, we introduce x-ray microcalorimeter detectors and discuss the diagnostic capability for magnetic fusion energy experiments. We describe our experimental setup and spectrometer operation approach at MST, and we present the results from an initial measurement campaign.

Eckart, M. E. (ORCID:0000000338945889)↗

STRIDES: a 3.9 per cent measurement of the Hubble constant from the strong lens system DES J0408−5354

We present a blind time-delay cosmographic analysis for the lens system DES J0408−5354. This system is extraordinary for the presence of two sets of multiple images at different redshifts, which provide the opportunity to obtain more information at the cost of increased modelling complexity with respect to previously analysed systems. We perform detailed modelling of the mass distribution for this lens system using three band Hubble Space Telescope imaging. We combine the measured time delays, line-of-sight central velocity dispersion of the deflector, and statistically constrained external convergence with our lens models to estimate two cosmological distances. We measure the ‘effective’ time-delay distance corresponding to the redshifts of the deflector and the lensed quasar |$D_{\Delta t}^{\rm eff}=$||$3382_{-115}^{+146}$| Mpc and the angular diameter distance to the deflector D_d = |$1711_{-280}^{+376}$| Mpc, with covariance between the two distances. From these constraints on the cosmological distances, we infer the Hubble constant H_0= |$74.2_{-3.0}^{+2.7}$| km s^−1 Mpc^−^1 assuming a flat ΛCDM cosmology and a uniform prior for Ω_m as |$\Omega _{\rm m} \sim \mathcal {U}(0.05, 0.5)$|⁠. This measurement gives the most precise constraint on H_0 to date from a single lens. Our measurement is consistent with that obtained from the previous sample of six lenses analysed by the H_0 Lenses in COSMOGRAIL’s Wellspring (H0LiCOW) collaboration. It is also consistent with measurements of H_0 based on the local distance ladder, reinforcing the tension with the inference from early Universe probes, for example, with 2.2σ discrepancy from the cosmic microwave background measurement.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Hydrogen Burner for FT4000® Aeroderivative Engine - Final Report

This report details an effort to develop a retrofittable fuel/air injector for the FT4000® aeroderivative gas turbine that enables use of hydrogen as a carbon-free fuel for efficient power generation. The FT4000 engine’s low-NOx combustor was developed by Pratt & Whitney and RTX Technology Research Center with core technology from the Pratt & Whitney PW4000 turbofan aircraft engine. The current FT4000 production engine operates on either natural gas or No. 2 fuel oil with water injection to achieve high thermal efficiency and low emissions. This engine is fielded by Mitsubishi Power Aero and delivers 70 MW of power with a simple-cycle efficiency of over 41% when operating with wet compression. The work reported here advances the technology readiness level of the FT4000 combustor for operation with hydrogen, starting with an experimental assessment of the current production hardware with increasing hydrogen content mixed with natural gas and ending with improved nozzle concepts for fully robust operation with 100% hydrogen. High-pressure single-sector combustor rig tests have been completed, demonstrating the ability for the dual fuel nozzle to operate an FT4000 combustor on 100% hydrogen with low nitrogen oxide (NOx) emissions. Metal temperature measurements and video images of the flame structure from zero to 100% hydrogen highlight opportunities to improve the fuel nozzle robustness for high hydrogen conditions. The design of new fuel/air mixer concepts to improve durability and operability with high hydrogen levels was also completed. A total of eleven new concepts were developed and analyzed, ranging from modifications to the bill-of-materials nozzle to fully clean sheet designs. The concepts were evaluated with non-reacting and reacting flow evaluations to assess the performance of the new hardware designs. Non-reacting tests included Phase Doppler Particle Analysis (PDPA) for droplet size and velocity, mechanical patternation for liquid water flux, and planar laser induced fluorescence (PLIF) with acetone-seeding for gaseous fuel/air mixing characterization. Five scaled candidate fuel nozzle designs, in addition to a scaled bill-of-materials nozzle, were then successfully evaluated in an atmospheric pressure burner rig. The nozzles were evaluated for performance with natural gas, hydrogen/natural gas blends, and pure hydrogen. For 100% hydrogen, the nozzles were evaluated with and without water injection. Optical and infrared imaging of the flame and fuel nozzle was captured. NOx emissions were sampled from fixed emissions probes. The results show measurable differences between the various designs, and the data was used to down-select the two most promising designs to advance to future full pressure rig testing. Results from this study have cleared the current production FT4000 engines with dual fuel nozzles to operate at baseload power on blends of hydrogen mixed with natural gas and water. Two promising nozzle designs have been developed to enable fully robust operation with up to 100% hydrogen. These nozzles require validation at full baseload operating conditions before they can be introduced to the field.

03 NATURAL GAS↗

A simple approach for characterizing the spatially varying sensitivity of microchannel plate detectors

Herein we present a simple approach to characterize the spatial variation of the gain in microchannel plate (MCP) coupled to phosphor detectors using single electron or photon hits. The technique is easy to implement and general enough to be extended to other kinds of detectors. We demonstrate the efficacy of the approach on both laboratory and Monte Carlo generated datasets. Furthermore, we use the approach to measure the variation in gain over time as the MCP is exposed to an increasing number of electrons.

47 OTHER INSTRUMENTATION↗

The Doppler Wind Temperature Sensor (DWTS) Flight Evaluation and Experiments (TES-16,17)

The Doppler Wind Temperature Sensor instrument (DWTS), developed by Global Atmospheric Technologies and Sciences (GATS), is a powerful yet simple tool with the potential of becoming a new window to upper atmosphere dynamics. Based around a defense-grade infrared camera peering through a static gas cell used as a scanning spectral filter, the DWTS is designed to measure the fingerprints of wind and thermal waves as they propagate to the mesosphere and lower thermosphere. DWTS achieves this scanning by measuring the induced change in the doppler shift of the emission as it passes through the DWTS field of view. DWTS holds promise to aid in more accurate weather determination (Gordley, et al), and the core technology can be easily adapted to study other atmospheres of interest. In partnership with GATS, NOAA, and other collaborators, NASA Ames and the Nano Orbital Workshop group have been working to evaluate the DWTS instrument on orbit and optimize it as a flexible cube satellite payload. The first mission selected for DWTS evaluation is preparing for flight in early 2024, followed by a more capable science mission in 2025, with both missions part of the TES-n/NOW flight series. The first flight, TES-16/DWTS-A, will incorporate a single DWTS instrument in an approximately 2U payload volume with the imaging aperture perpendicular to the flight velocity vector. With an estimated power consumption of 20 watts, supplied via a custom NOW-designed GaN converter, the instrument will maintain the imaging sensor plane at 80K using an integrated pulse-tube cryocooler during instrument evaluation periods. Data from DWTS will be captured via a NOW-designed custom data processor before being transmitted via S-band radio back to select ground stations, with instrument command and control operated via L-band global-coverage radio. After the TES-16/DWTS-A initial demonstration mission, the subsequent TES-17/DWTS-B mission will be a dedicated science mission equipped with three DWTS instruments, each hosting a different gas cell to obtain full altitude coverage from 20 to 200 km both day and night from a single cube satellite. The intention of the flight series, and one of NASA’s interests in the instrument, is to advance a Martian atmospheric instrument (Colaprete, Gordley, et al) which, if successful, would greatly further understanding of Martian atmospheric behavior. The proposed paper will review the flight series in detail, including challenges from the TES-16 flight tests and the projected challenges and application to Mars study. Additional detail regarding the possible applications of a Cognitive Communication technique in current flight development by NOW collaborators at the NASA Glenn Research Center will also be discussed, including the implications of using an automated User Initiated Service (UIS) protocol to maximize the data collected per orbit.

Doppler Wind Temperature Sensor↗

Development of a Comprehensive Two-Phase Flow Database for the Validation of NEK-2P

Three-dimensional (3-D) two-phase Computational Fluid Dynamics (CFD) codes are emerging as a powerful and potentially practical tool for applications in which detailed local flow information is needed. However, two-phase flow models and associated closure relations are not well established for CFD applications, which is partly due to the lack of high-quality validation data. The main objective of this work is to develop a comprehensive database of two-phase flows that can be used to validate two-phase CFD codes such as NEK-2P. In this project, four advanced local measurement systems, including Particle Image Velocimetry and Planar Laser-Induced Fluorescence (PIV-PLIF), high-speed imaging, x-ray densitometry, and multi-sensor conductivity probe are employed to measure the local two-phase flow parameters of both gas and liquid phases. By combining these techniques, the local void fraction, bubble velocity, interfacial area concentration, bubble frequency, liquid velocity, turbulence intensity, etc., in various two-phase flow regimes can be obtained. These local measurement techniques are first used in a 25.4 mm circular pipe test section. Seven air-water two-phase flow conditions spanning the bubbly, slug, churn-turbulent, and annular flow regimes are measured in this facility. The obtained database contains the radial profiles of both gas- and liquid-phase parameters at three axial locations along the test section. The second facility used in this work contains a 30 mm × 10 mm rectangular test section, in which three two-phase flow and two single-phase flow conditions are measured. Two-dimensional distributions of local two-phase flow parameters in the cross-sectional plane are measured in this facility at three axial locations as well. A facility featuring a 3×3 electrically heated rod bundle is also designed and being constructed in this project. This facility is specially designed for optical measurements and is expected to provide high-quality boiling data in the future. Preliminary analyses have been performed for the data taken in the 25.4 mm circular pipe. Both center-peaked and wall-peaked void fraction profiles have been observed in the data depending on the two-phase flow conditions and/or developing lengths. The 1-D drift-flux model was evaluated with the newly obtained datasets, in which both gas- and liquid-phases data were directly measured. The distribution parameter model has been optimized based on a new void-profile classification method proposed in this study. The optimized drift-flux model shows a significant improvement in predicting both gas velocity and void fraction. The measured liquid-phase turbulence was used to benchmark Sato’s turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. In the bubbly flows tested that have low void fractions less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction. The Conjugate Heat Transfer (CHT) model was developed and implemented in NEK-2P. This model allows the coupled simulation of the solid domain and two-phase fluid domain, allowing the specification of realistic boundary conditions. The CHT implementation was verified first with non-boiling simulations. The predicted temperatures in the fluid domain were shown to be identical in simulations with or without the CHT model. The CHT model was then validated through simulations of three Becker benchmark CHF tests performed under both Dryout (DO) and Departure from Nucleate Boiling (DNB) conditions. Reasonably good agreement was obtained between calculated wall temperatures and corresponding experimental data.

42 ENGINEERING↗

Magnetic TRAnsition Region Probe (MTRAP)

MTRAP (Magnetic Transition Region Probe) will reveal the fine-scale physical processes in the Sun's magnetic transition region, the complex layer from the upper photosphere to the upper chromosphere/lower transition region. In the magnetic transition region plasma forces and magnetic forces are of comparable strength, which results in complex interplay of the two, which interplay governs the coupling of the convectively-driven deeper layers to the magnetically-driven upper transition region and inner corona. The fine-scale magnetic structure, processes, and events in the magnetic transition region are key to the genesis of the Sun's entire hot, dynamic outer atmosphere and to the initiation of large eruptive events. MTRAP will be a single spacecraft in Sun-synchronous Earth orbit. Because MTRAP will probe and measure the 3-D structure and dynamics of the magnetic field and plasma in the chromosphere and transition region with unprecedented resolution, the required telescope size and telemetry rates dictate that MTRAP be in Earth orbit, not in deep space. The observations will feature visible and infrared maps of vector magnetic and velocity fields in the magnetic transition region and photosphere. These will have large field of view (greater than 100,000 km), high resolution (greater than 100 km), and high sensitivity (greater than 30 G in transverse field). These observations of the lower atmosphere will be complemented by UV maps of the structure, velocity, and magnetic field (including the full vector field if technically feasible) higher up, in the upper chromosphere and lower transition region. MTRAP will also have an EUV imaging spectrograph observing coronal structure and dynamics in the same field of view with comparable resolution. Specific phenomena to be analyzed include spicules, bright points, jets, the base of plumes, and the triggering of eruptive flares and coronal mass ejections. Additional information is included in the original extended abstract.

Moore, R. L.↗

Slat Noise Control Using a Slat Gap Filler

The leading edge slat of a high-lift system is one of the main noise contributors on many commercial aircraft during approach. This paper continues our previous studies on the gap filler for passive noise control on the 30P30N high-lift airfoil. An improved implementation of the gap filler was applied to minimize the effects of flow leakage encountered in the previous work, which resulted in spurious noise content in the far-field acoustic spectra. To evaluate the effect of passive flow control on the acoustics generated by the unsteady flow field, anechoic wind tunnel experiments are conducted on the two-dimensional, three-element high-lift airfoil with a gap filler mounted to the slat. The slat geometry modification associated with the gap filler alters the flow field in the cove region that dominates the generation of the acoustic field. A single angle of attack (훼푘=8◦) and three flow speeds corresponding to Reynolds numbersof푅푒푐=1.2푒6,1.5푒6, and1.71푒6are selected as the test conditions. Steady surface pressure measurements are conducted to assess the effect of the treatments on the overall lift. Acoustic array measurements are used to evaluate the influence of the gap filler on the radiated noise. Delay and Sum beamforming is applied to locate the noise sources on the model and to provide the integrated spectra. The gap filler is found to eliminate the narrowband peaks in the acoustic spectra and, also, to yield a 10 dB reduction in the broadband noise in comparison with the baseline case. Time-resolved Particle Image Velocimetry results show that the flow features are significantly altered with the presence of the gap filler, which leads to a more stable slat cove shear layer and, thus, to weaker pressure and velocity fluctuations.

Yang Zhang↗

GPS/MEMS IMU/Microprocessor Board for Navigation

A miniaturized instrumentation package comprising a (1) Global Positioning System (GPS) receiver, (2) an inertial measurement unit (IMU) consisting largely of surface-micromachined sensors of the microelectromechanical systems (MEMS) type, and (3) a microprocessor, all residing on a single circuit board, is part of the navigation system of a compact robotic spacecraft intended to be released from a larger spacecraft [e.g., the International Space Station (ISS)] for exterior visual inspection of the larger spacecraft. Variants of the package may also be useful in terrestrial collision-detection and -avoidance applications. The navigation solution obtained by integrating the IMU outputs is fed back to a correlator in the GPS receiver to aid in tracking GPS signals. The raw GPS and IMU data are blended in a Kalman filter to obtain an optimal navigation solution, which can be supplemented by range and velocity data obtained by use of (l) a stereoscopic pair of electronic cameras aboard the robotic spacecraft and/or (2) a laser dynamic range imager aboard the ISS. The novelty of the package lies mostly in those aspects of the design of the MEMS IMU that pertain to controlling mechanical resonances and stabilizing scale factors and biases.

Gender, Thomas K.↗

Alignment Jig for the Precise Measurement of THz Radiation

A miniaturized instrumentation package comprising a (1) Global Positioning System (GPS) receiver, (2) an inertial measurement unit (IMU) consisting largely of surface-micromachined sensors of the microelectromechanical systems (MEMS) type, and (3) a microprocessor, all residing on a single circuit board, is part of the navigation system of a compact robotic spacecraft intended to be released from a larger spacecraft [e.g., the International Space Station (ISS)] for exterior visual inspection of the larger spacecraft. Variants of the package may also be useful in terrestrial collision-detection and -avoidance applications. The navigation solution obtained by integrating the IMU outputs is fed back to a correlator in the GPS receiver to aid in tracking GPS signals. The raw GPS and IMU data are blended in a Kalman filter to obtain an optimal navigation solution, which can be supplemented by range and velocity data obtained by use of (l) a stereoscopic pair of electronic cameras aboard the robotic spacecraft and/or (2) a laser dynamic range imager aboard the ISS. The novelty of the package lies mostly in those aspects of the design of the MEMS IMU that pertain to controlling mechanical resonances and stabilizing scale factors and biases.

Javadi, Hamid H.↗

SYSTEMATIC MULTI-INDEX VALIDATIONS OF SIDI ENGINE FLOW FIELD LES COMPUTATIONS USING CRANK ANGLE-RESOLVED PIV MEASUREMENTS

In-cylinder flow fields make significant impacts on the fuel atomization, fuel mixture formation, and combustion process in spark ignition direct injection (SIDI) engines. In recent years, model-based simulation approaches are preferred in regard to investigating the transient in-cylinder flow field characteristics. Most commonly, the simulation models are validated using single representative flow field at a typical crank angle measured by particle image velocimetry (PIV). However, it provides only limited knowledge about the flow field which is highly three-dimensional and of transient nature. In this study, crank angle-resolved Ply measurements are conducted on three distinct planes inside the cylinder to capture the transient process of flow field characteristics which vary with the crank angle. These three planes consist of one tumble plane through the spark plug tip, one tumble plane along two intake ports, and one swirl plane at 30 mm below the cylinder head. Large eddy simulation (LES) is employed for the numerical computations using the CONVERGE codes. On the basis of large datasets for both temporal and spatial domains, a multi-index systematic validation approach is conducted. Crank angle-resolved calculations of global indices and local indices are implemented using the flow fields velocity data obtained from both PIV and LES on select planes. Global indices reveal the trends in similarities of different crank angle degrees and locations, while local indices give the detail comparison results. In summary, with the systematic multi-index validation approach, the crucial crank angle degrees and locations for model verification will be detected. Furthermore, the corresponding critical flow features are analyzed. Practical guideline of flow field validation is proposed.

Crank angle-resolved PIV↗