Search NASA⌕ Search

SEARCH · Search NASA

Results for “size measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small–field animal irradiation studies

To develop and implement an efficient and accurate commissioning procedure for small-field static beam animal irradiation studies on an MV research linear accelerator (Linatron-M9) using radiochromic gel dosimetry. The research linear accelerator (Linatron-M9) is a 9 MV linac with a static fixed collimator opening of 5.08 cm diameter. Lead collimators were manually placed to create smaller fields of 2 × 2 cm 2 , 1 × 1 cm 2 , and 0.5 × 0.5 cm 2 . Relative dosimetry measurements were performed, including profiles, percent depth dose (PDD) curves, beam divergence, and relative output factors using various dosimetry tools, including a small volume ionization chamber (A14), GAFCHROMIC™ EBT3 film, and Clearview gel dosimeters. The gel dosimeter was used to provide a 3D volumetric reference of the irradiated fields. The Linatron profiles and relative output factors were extracted at a reference depth of 2 cm with the output factor measured relative to the 2 × 2 cm 2 reference field. Absolute dosimetry was performed using A14 ionization chamber measurements, which were verified using a national standards laboratory remote dosimetry service. Absolute dosimetry measurements were confirmed within 1.4% (k = 2, 95% confidence = 5%). The relative output factor of the small fields measured with films and gels agreed with a maximum relative percent error difference between the two methods of 1.1 % for the 1 × 1 cm 2 field and 4.3 % for the 0.5 × 0.5 cm 2 field. These relative errors were primarily due to the variability in the collimator positioning. The measured beam profiles demonstrated excellent agreement for beam size (measured as FWHM), within approximately 0.8 mm (or less). Film measurements were more accurate in the penumbra region due to the film’s finer resolution compared with the gel dosimeter. Following the van Dyk criteria, the PDD values of the film and gel measurements agree within 11% in the buildup region starting from 0.5 cm depth and within 2.6 % beyond maximum dose and into the fall-off region for depths up to 5 cm. The 2D beam profile isodose lines agree within 0.5 mm in all regions for the 0.5 × 0.5 cm 2 and the 1 × 1 cm 2 fields and within 1 mm for the larger field of 2 × 2 cm 2 . The 2D PDD curves agree within approximately 2% of the maximum in the typical therapy region (1–4 cm) for the 1 × 1 cm 2 and 2 × 2 cm 2 and within 5% for the 0.5 × 0.5 cm 2 field. This work provides a commissioning process to measure the beam characteristics of a fixed beam MV accelerator with detailed dosimetric evaluation for its implementation in megavoltage small animal irradiation studies. Radiochromic gel dosimeters are efficient small-field relative dosimetry tools providing 3D dose measurements allowing for full representation of dose, dosimeter misalignment corrections and high reproducibility with low inter-dosimeter variability. Altogether, radiochromic gels are valuable for fast, full relative dosimetry commissioning in comparison to films for application in high-energy small-field animal irradiation studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Size distributions in two porous chondritic micrometeorites

Quantitative size measurements of granular units (GUs), and nm-sized minerals in these units, in two porous chondritic micrometeorites are investigated. The matrix of these micrometeorites consist of loosely packed, 0.1 micron-sized, GUs. These objects were a major component of the solar nebula dust that accreted into protoplanets. The matrix in micrometeorite W7010*A2 has a fractal dimension with a small coefficient that supports efficient sticking of carbon-rich GUs during accretion. The fractal nature of the matrix provides a way to calculate the density using the aggregate size. The resulting very low density for porous chondritic micrometeorites is 0.08-0.14 g/cu cm, which supports the view that they are the solid debris from unconsolidated solar system bodies. Chondritic GUs contain ultrafine olivines, pyroxenes, and sulfides, embedded in hydrocarbons and amorphous carbons. Nanocrystals in the micrometeorites W7010*A2 and U2015*B show log normal size distributions. The high incidence of disk-shaped grains, a changeover from disk-shaped to euhedral grains, the unevolved nature of the size distributions, and multiple populations for grains less than 127 nm in size, are consistent with continuous postaccretion nucleation and growth in amorphous GUs, including coarsening via Ostwald ripening.

Rietmeijer, Frans J. M.↗

Characterizing Detailed Grain Shape and Size Distribution Properties of Lunar Regolith

Introduction: As the nation prepares to return to the Moon, there is an increasing need for testing tools, instruments, and equipment in simulated environments on Earth to ensure successful operations during lunar missions. Regolith will affect all aspects of future lunar missions, from plume interactions during landing to space suit and tool design [1]. Because of this, it is important to understand the grain shape and size properties of lunar regolith and how those influence regolith behavior in order to prepare for these missions. This knowledge is also vital to create more accurate lunar regolith simulants for testing equipment in a lunar environment. While particle size analyses have been performed on most Apollo soils using simple sieving, shape has only been crudely addressed [2]. This work analyzes 4 lunar regolith samples to provide a better understanding of these size and shape parameters and will provide a more accurate baseline of data to create high-fidelity lunar regolith simulants. Methods: New technologies exist today that are capable of measuring size and shape simultaneously for hundreds of thousands of particles in a single measurement. We conducted a rigorous analysis of the particle size distribution (PSD) as well as the size-dependent 2D and 3D shape parameters of lunar regolith samples of different compositions and maturity levels. This analysis was done using a Microtrac SYNC which provides a unique combination of tri-laser diffraction and Dynamic Image Analysis (DIA). Sample Selection. Four regolith samples were selected for analysis based on maturity level and lunar terrain type: • 10084 – Mature high-Ti mare regolith • 15601 – Immature low-Ti mare regolith • 64501 – Mature highland regolith • 67461 – Immature highland regolith Sample Analysis. After receiving the samples, each sample was imaged with an optical microscope (Figure 1). To obtain 2D and 3D particle size and shape, 0.1 g of each sample was then added to the SYNC for analysis, which outputs more than 30 size and shape parameters for each individual grain as well as the complete size distribution from 0.01-2000 μm by blending laser diffraction and DIA together. For the 0.1 g sample masses requested, ~100,000 grains per sample were captured by DIA. Results: From the PSD analysis, it can be seen that the average particle size of 10084 is ~24.5 µm which is much smaller than the average particle size of the Apollo sample collection (~72 µm) [3], while the average particle size of samples 15601, 64501, and 67461 are larger than the Apollo sample average at ~106 µm, ~103 µm, and ~118.5 µm respectively. The size and shape measurements for the samples output ~30 parameters, four of which were focused on for this study: sphericity, aspect ratio, roundness, and concavity (Figure 3). However, after analyzing the plots it was found that only sphericity and aspect ratio showed differences between the samples. These two parameters are measured on a scale from 0 to 1, with 1 being a perfect sphere with equal dimensions. The results show that the sphericity values are slightly high-er for the mature samples 10084 and 64501 (~0.96) than they are for samples 15601 and 67461 (~0.95) (Figure 4). The aspect ratio values are slightly lower for samples 64501 (~0.7) and 67461 (~0.74) than they are for samples 10084 (~0.76) and 15601 (~0.8) (Figure 5). Discussion: Mature regoliths are those that have been exposed to micrometeorite and solar wind bombardment for long periods of time, breaking up particles and causing them to become more rounded [4]. Therefore, the smaller particle sizes and higher sphericity values for samples 10084 and 64501 are expected due to their higher maturity level compared to 15601 and 67461. However, the aspect ratio values are not dependent on maturity and are instead dependent on terrain type. The lower aspect ratio values for the high-land samples is potentially due to the higher plagioclase content, which occurs in elongated particles and does not break down as easily as the pyroxenes or olivines that are present in the mare. Conclusion and Future Work: The results of this work provide a baseline of high-quality data that will contribute to the creation of high-fidelity lunar simulants and will greatly benefit NASA’s efforts of establishing a human presence on the Moon. Future work includes performing unsupervised image classification on the ~105 particle images per sample in order to identify different classes of grains. These grain classes can then be linked to detailed shape properties, and the relative abundance of each class in the samples can be compared. Acknowledgments: We would like to thank the Extraterrestrial Materials Analysis Group (ExMAG) and the Astromaterials Allocation Review Board (AARB) for allocating lunar regolith samples 10084,9010, 15601,365, 64501,249, and 67461,171 for this work. References: [1] Taylor, L. A. et al. (2005) AIAA #2510. [2] Katagiri et al. (2015) ASCE. [3] Carrier III, W. D. (2005) Lunar Geotech Institute Tech Report. [4] McKay, D. S. et al. (1991) The Lunar Sourcebook, Chapter 7.

S R Deitrick↗

Particle size and velocity measurement in flames by laser anemometer

Simultaneous droplet size and velocity measurements by a particle counting Laser Doppler Anemometer (LDA) in kerosene fuel sprays under burning and non-burning conditions are presented. Particle sizes are derived from pulse height analysis of the mean LDA signals and velocities are simultaneously determined by measuring Doppler shift frequencies. The measurements show that droplet velocity is a function of droplet diameter for burning and non-burning conditions, and spatially averaged size distributions are derived from velocity data. A comparison of results obtained under burning and non-burning conditions show changes in size distribution due to preferential vaporization of small droplets, acceleration due to thermal expansion of gases, and corresponding changes in droplet momentum.

Chigier, N. A.↗

Overview of high-density QCD studies with the CMS experiment at the LHC

We review key measurements performed by CMS in the context of its heavy ion physics program, using event samples collected in 2010-2018 with several collision systems and energies. These studies provide detailed macroscopic and microscopic probes of the quark-gluon plasma (QGP) created at the LHC energies, a medium characterized by the highest temperature and smallest baryon-chemical potential ever reached in the laboratory. Numerous observables related to high-density quantum chromodynamics (QCD) were studied, leading to some of the most impactful and qualitatively novel results in the 40-year history of the field. Using a dedicated high-multiplicity trigger in the first pp run, CMS discovered that small collision systems can exhibit signs of collectivity, a generic phenomenon with significant implications and presently understood to affect essentially all soft physics processes. This observation opened new paths to understand how fluidity and plasma properties emerge in QCD matter as a function of system size. Measurements of jet quenching have reached a completely new level of detail by directly assessing, for the first time, the medium modification of parton showers, as opposed to simply observing leading hadrons or di-hadrons. The first fully reconstructed beauty hadron and heavy-flavor jet nuclear modifications were also measured. The large size of the event samples, the precision of the measurements, and the extension of the probed kinematical phase space, allowed many other hard probes of the QGP medium to be explored in detail, leading to multiple groundbreaking findings. In particular, the seminal measurements of bottomonium suppression patterns answer fundamental questions that have been actively pursued, both theoretically and experimentally, by the community since the mid-1980s. We conclude by outlining the opportunities offered by the continuation of this physics program at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of Directional Array Size on the Measurement of Airframe Noise Components

A study was conducted to examine the effects of overall size of directional (or phased) arrays on the measurement of aeroacoustic components. An airframe model was mounted in the potential core of an open-jet windtunnel, with the directional arrays located outside the flow in an anechoic environment. Two array systems were used; one with a solid measurement angle that encompasses 31.6 deg.of source directivity and a smaller one that encompasses 7.2 deg. The arrays, and sub-arrays of various sizes, measured noise from a calibrator source and flap edge model setups. In these cases, noise was emitted from relatively small, but finite size source regions, with intense levels compared to other sources. Although the larger arrays revealed much more source region detail, the measured source levels were substantially reduced due to finer resolution compared to that of the smaller arrays. To better understand the measurements quantitatively, an analytical model was used to define the basic relationships between array to source region sizes and measured output level. Also, the effect of noise scattering by shear layer turbulence was examined using the present data and those of previous studies. Taken together, the two effects were sufficient to explain spectral level differences between arrays of different sizes. An important result of this study is that total (integrated) noise source levels are retrievable and the levels are independent of the array size as long as certain experimental and processing criteria are met. The criteria for both open and closed tunnels are discussed. The success of special purpose diagonal-removal processing in obtaining integrated results is apparently dependent in part on source distribution. Also discussed is the fact that extended sources are subject to substantial measurement error, especially for large arrays.

Brooks, Thomas F.↗

Two-phase flow

An experimental program to characterize the spray from candidate nozzles for icing-cloud simulation is discussed. One canidate nozzle, which is currently used for icing research, has been characterized for flow and drop size. The median-volume diameter (MVD) from this air-assist nozzle is compared with correlations in the literature. The new experimental spray facility is discussed, and the drop-size instruments are discussed in detail. Since there is no absolute standard for drop-size measurements and there are other limitations, such as drop -size range and velocity range, several instruments are used and results are compared. A two-phase model was developed at Pennsylvania State University. The model uses the k-epsilon model of turbulence in the continous phase. Three methods for treating the discrete phase are used: (1) a locally homogeneous flow (LHF) model, (2) a deterministic separated flow (DSF) model, and (3) a stochastic separated flow (SSF) model. In the LHF model both phases have the same velocity and temperature at each point. The DSF model provides interphase transport but ignores the effects of turbulent fluctuations. In the SSF model the drops interact with turbulent eddies whose properties are determined by the k-epsilon turbulence model. The two-phase flow model has been extended to include the effects of evaporation and combustion.

Tacina, Robert R.↗

Evaluation of ultrasonics and optimized radiography for 2219-T87 aluminum weldments

Ultrasonic studies are described which are specifically directed toward the quantitative measurement of randomly located defects previously found in aluminum welds with radiography or with dye penetrants. Experimental radiographic studies were also made to optimize techniques for welds of the thickness range to be used in fabricating the External Tank of the Space Shuttle. Conventional and innovative ultrasonic techniques were applied to the flaw size measurement problem. Advantages and disadvantages of each method are discussed. Flaw size data obtained ultrasonically were compared to radiographic data and to real flaw sizes determined by destructive measurements. Considerable success was achieved with pulse echo techniques and with 'pitch and catch' techniques. The radiographic work described demonstrates that careful selection of film exposure parameters for a particular application must be made to obtain optimized flaw detectability. Thus, film exposure techniques can be improved even though radiography is an old weld inspection method.

Clotfelter, W. N.↗

Experimental Investigation of Solder Joint Defect Formation and Mitigation in Reduced-Gravity Environments

This paper documents a research effort on reduced gravity soldering of plated through hole joints which was conducted jointly by the National Center for Space Exploration Research, NASA Glenn Research Center, and NASA Johnson Space Center. Significant increases in joint porosity and changes in external geometry were observed in joints produced in reduced gravity as compared to normal gravity. Multiple techniques for mitigating the observed increase in porosity were tried, including several combinations of flux and solder application techniques, and demoisturizing the circuit board prior to soldering. Results were consistent with the hypothesis that the source of the porosity is a combination of both trapped moisture in the circuit board itself, as well as vaporized flux that is trapped in the molten solder. Other topics investigated include correlation of visual inspection results with joint porosity, pore size measurements, limited pressure effects (0.08 MPa - 0.1 MPa) on the size and number of pores, and joint cooling rate.

Watson, J. Kevin↗

Adaptation of fibers in fast-twitch muscles of rats to spaceflight and hindlimb suspension

The adaptation of single fibers in medial gastrocnemius (MG), a fast-twitch extensor, and in tibialis anterior (TA), a fast-twitch flexor, was studied after 14 days of spaceflight onboard Cosmos 2044 or hindlimb suspension. Quantitative myosin ATPase activities of single fibers were measured in flight and suspended rats. Each of the enzyme and size measurements were directly correlated within each fiber with respect to its qualitative myosin ATPase staining properties and its expression of fast, slow, or both myosin heavy chains (MHC). The percentage of slow- and fast-twitch fibers of the MG and TA were found to be unchanged. Mean fiber size of all fibers was unaffected after flight or suspension. The ATPase activity in the MG was higher in flight than in control or suspended rats. In comparison to Cosmos 1887 spaceflight, the adaptations in the muscle fibers of the MG were more moderate.

Jiang, Bian↗

Radio structure at 8.4 GHz in Sagittarius A, the compact radio source at the Galactic center

VLBI observations of the compact, nonthermal radio source at the Galactic center show it to be elongated at 8.4 GHz along a position angle of 82 + or - 6 deg. The source has an axial ratio of 0.53 + or - 0.10 with a major axis of 17.4 + or - 0.5 mas. Examination of VLA maps of the Galactic center region indicate no obvious alignment with this smaller-scale elongation of the nuclear region, nor is the nuclear position angle aligned with the axis of Galactic rotation. Comparison with the size measured at frequencies from 1 to 22 GHz shows that the size follows very closely the lambda-squared dependence expected from interstellar scattering. The alongated nature of the source implies either that the scattering medium is anisotropic or that some remnant of the intrinsic structure remains visible through the scattering medium.

Jauncey, David L.↗

Atmospheric Blocking Drives Recent Albedo Change Across the Western Greenland Ice Sheet Percolation Zone

Greenland Ice Sheet (GrIS) albedo has decreased over recent decades, contributing to enhanced surface melt and mass loss. However, it remains unclear whether GrIS darkening is due to snow grain size increases, higher concentrations of light-absorbing impurities (LAIs), or a combination. Here, we assess albedo controls in the western GrIS percolation zone using in situ albedo, LAI, and grain size measurements. We find a significant correlation between albedo and snow grain size (p < 0.01), but not with LAIs. Modeling corroborates that LAI concentrations are too low to significantly reduce albedo, but larger grain sizes could reduce albedo by at least ∼3%. Strong atmospheric blocking increases grain sizes and reduces albedo through increased surface temperature, fewer storms, and higher incoming shortwave radiation. These findings clarify the mechanisms by which anomalously strong blocking contributed to recent GrIS albedo decline and mass loss, highlighting the importance of improving projections of future blocking.

Gabriel Lewis↗

Lessons Learned from the Airborne Particulate Monitor ISS Payload

Particulate monitoring on spacecraft has not been undertaken for air quality purposes for the first twenty years of human habitation on the International Space Station (ISS). The Airborne Particulate Monitor (APM) is a reference-quality instrument technology demonstration that characterized the airborne particles in the ISS cabin in real-time. Onboard aerosols have been measured with this higher fidelity instrument, so future miniaturized low-power aerosol instruments can be reliably compared in future ISS experiments. Several issues were encountered during the payload operations that are a result of the unique environment on ISS, which could not have been anticipated or eliminated by ground testing. First, the ISS had very small amounts of particulate matter in the particle measurement size range of the APM, which was unexpected. Second, despite the measured ‘clean’ environment, larger debris such as lint accumulated regularly on the cleanable inlet screen, which required regular inspection and crew time. The third issue is that particle emissions measured on ISS depend only on the activities in the immediate vicinity of the particle instrument and total particle concentrations cannot be generalized for the entire module. Finally, the sampling efficiency of APM on ISS is unknown because aisle-deployed instruments attached to wall panels of ISS are in the boundary layer of the large-scale ventilation flow of the modules. These issues are discussed and potential solutions for future particulate monitors are presented.

aerosol↗

Analysis and testing of a new method for drop size and velocity measurements using laser light scatter interferometry

Drop size and velocity can be measured simultaneously using an optical system which is the same as a laser Doppler velocimeter except that three detectors are located at selected spacings behind the receiver aperture. Drops passing through the intersection of the two beams scatter light which produces an interferrence fringe pattern. The temporal frequency of the fringe pattern is the Doppler difference frequency which is linearly proportional to the drop velocity while the spatial frequency is linearly related to the drop diameter. The spacing of the fringes is also dependent upon the light wavelength, beam intersection angle, drop refractive index (unless reflected light is measured), and the location of the receiver. The theoretical analysis was verified, signal phase processing methods were evaluated, and the effects of signal quality upon the measurements were investigated.

Bachalo, W. D.↗

Tethered Balloon Observations of Vertically Resolved Aerosol Size Distributions during the U.S. DOE ARM CoURAGE and BNF Campaigns

This dataset contains vertically resolved aerosol particle number size distributions measured using a miniature Scanning Electrical Mobility Spectrometer (mSEMS) deployed aboard the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Tethered Balloon System (TBS) during the 2025 Coast-Urban-Rural Atmospheric Gradient Experiment (CoURAGE) and Bankhead National Forest (BNF) field campaigns. The mSEMS measured aerosol size distributions over approximately 10–300 nm during repeated TBS vertical profiles through the atmospheric boundary layer. The dataset provides measurements of particle number size distributions as a function of particle diameter, altitude, and time and supports investigation of aerosol vertical structure, elevated ultrafine and Aitken-mode particle layers, boundary-layer evolution, and residual-layer processes.

ARM↗

Laser Scanner for Tile-Cavity Measurement

Irregular surfaces mapped and digitized for numerical-control machinery. Fast, accurate laser scanning system measures size and shape of cavity without making any physical contact with cavity and walls. Measurements processed into control signals for numerically controlled machining of tile or block to fit cavity. System generates map of grid points representing cavity and portion of outer surface surrounding cavity. Map data used to control milling machine, which cuts tile or block to fit in cavity.

Yoshino, Stanley Y.↗

Evidence of Inverse Hall-Petch Behavior and Low Friction and Wear in High Entropy Alloys

We present evidence of inverse Hall-Petch behavior for a single-phase high entropy alloy (CoCrFeMnNi) in ultra-high vacuum and show that it is associated with low friction coefficients (~0.3). Grain size measurements by STEM validate a recently proposed dynamic amorphization model that accurately predicts grain size-dependent shear strength in the inverse Hall-Petch regime. Wear rates in the initially soft (coarse grained) material were shown to be remarkably low (~10 –6 mm 3 /N-m), the lowest for any HEA tested in an inert environment where oxidation and the formation of mixed metal-oxide films is mitigated. The combined high wear resistance and low friction are linked to the formation of an ultra-nanocrystalline near-surface layer. The dynamic amorphization model was also used to predict an average high angle grain boundary energy (0.87 J/m 2 ). This value was used to explain cavitation-induced nanoporosity found in the highly deformed surface layer, a phenomenon that has been linked to superplasticity.

36 MATERIALS SCIENCE↗