Search NASA⌕ Search

SEARCH · Search NASA

Results for “skin”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Quantitative image analysis of laminin immunoreactivity in skin basement membrane irradiated with 1 GeV/nucleon iron particles

We previously reported that laminin immunoreactivity in mouse mammary epithelium is altered shortly after whole-body irradiation with 0.8 Gy from 600 MeV/nucleon iron ions but is unaffected after exposure to sparsely ionizing radiation. This observation led us to propose that the effect could be due to protein damage from the high ionization density of the ion tracks. If so, we predicted that it would be evident soon after radiation exposure in basement membranes of other tissues and would depend on ion fluence. To test this hypothesis, we used immunofluorescence, confocal laser scanning microscopy, and image segmentation techniques to quantify changes in the basement membrane of mouse skin epidermis. At 1 h after exposure to 1 GeV/nucleon iron ions with doses from 0.03 to 1.6 Gy, neither the visual appearance nor the mean pixel intensity of laminin in the basement membrane of mouse dorsal skin epidermis was altered compared to sham-irradiated tissue. This result does not support the hypothesis that particle traversal directly affects laminin protein integrity. However, the mean pixel intensity of laminin immunoreactivity was significantly decreased in epidermal basement membrane at 48 and 96 h after exposure to 0.8 Gy 1 GeV/nucleon iron ions. We confirmed this effect with two additional antibodies raised against affinity-purified laminin 1 and the E3 fragment of the long-arm of laminin 1. In contrast, collagen type IV, another component of the basement membrane, was unaffected. Our studies demonstrate quantitatively that densely ionizing radiation elicits changes in skin microenvironments distinct from those induced by sparsely ionizing radiation. Such effects may might contribute to the carcinogenic potential of densely ionizing radiation by altering cellular signaling cascades mediated by cell-extracellular matrix interactions.

Non-NASA Center↗

Tests of Flammability of Cotton Fabrics and Expected Skin Burns in Microgravity

During a shuttle launch and other portions of space flight, astronauts wear specialized flame resistant clothing. However during most of their missions on board the Space Shuttle or International Space Station, astronauts wear ordinary clothing, such as cotton shirts and pants. As the behaviour of flames is considerably different in microgravity than under earth s gravity, fabrics are expected to burn in a different fashion in microgravity than when tested on earth. There is interest in determining how this change in burning behaviour may affect times to second and third degree burn of human skin, and how the results of standard fabric flammability tests conducted under earth s gravity correlate with the expected fire behaviour of textiles in microgravity. A new experimental apparatus was developed to fit into the Spacecraft Fire Safety Facility (SFSF), which is used on NASA s KC-135 low gravity aircraft. The new apparatus was designed to be similar to the apparatus used in standard vertical flammability tests of fabrics. However, rather than using a laboratory burner, the apparatus uses a hot wire system to ignite 200 mm high by 80 mm wide fabric specimens. Fabric temperatures are measured using thermocouples and/or an infrared imaging system, while flame spread rates are measured using real time observations or video. Heat flux gauges are placed between 7 and 13 mm away from the fabric specimen, so that heat fluxes from the burning fabric to the skin can be estimated, along with predicted times required to produce skin burns.

Cavanagh, Jane M.↗

Cyclooxygenases in human and mouse skin and cultured human keratinocytes: association of COX-2 expression with human keratinocyte differentiation

Epidermal expression of the two isoforms of the prostaglandin H-generating cyclooxygenase (COX-1 and COX-2) was evaluated both by immunohistochemistry performed on human and mouse skin biopsy sections and by Western blotting of protein extracts from cultured human neonatal foreskin keratinocytes. In normal human skin, COX-1 immunostaining is observed throughout the epidermis whereas COX-2 immunostaining increases in the more differentiated, suprabasilar keratinocytes. Basal cell carcinomas express little if any COX-1 or COX-2 immunostaining whereas both isozymes are strongly expressed in squamous cell carcinomas deriving from a more differentiated layer of the epidermis. In human keratinocyte cultures, raising the extracellular calcium concentration, a recognized stimulus for keratinocyte differentiation, leads to an increased expression of both COX-2 protein and mRNA; expression of COX-1 protein, however, shows no significant alteration in response to calcium. Because of a recent report that failed to show COX-2 in normal mouse epidermis, we also looked for COX-1 and COX-2 immunostaining in sections of normal and acetone-treated mouse skin. In agreement with a previous report, some COX-1, but no COX-2, immunostaining is seen in normal murine epidermis. However, following acetone treatment, there is a marked increase in COX-1 expression as well as the appearance of significant COX-2 immunostaining in the basal layer. These data suggest that in human epidermis as well as in human keratinocyte cultures, the expression of COX-2 occurs as a part of normal keratinocyte differentiation whereas in murine epidermis, its constitutive expression is absent, but inducible as previously published.

NASA Discipline Cell Biology↗

Amorphous material of the skin in amyotrophic lateral sclerosis: a morphologic and biochemical study

We performed morphologic studies on skin from seven patients with ALS and seven control subjects. By light microscopy, the wide spaces that separated collagen bundles reacted strongly with colloidal iron and alcian blue in ALS patients. Electron microscopy revealed markedly increased amorphous material that was positive for ruthenium red in the ground substance. These findings were not present in controls. Quantitative amino acid analysis showed that the amount of total amino acids (nmoles per mg dry weight) was significantly decreased (p < 0.01) in ALS patients compared with that of controls, and there was a significant negative correlation between skin amino acid content and duration of illness in ALS patients (r = -0.83, p < 0.001). These morphologic findings and biochemical data indicate that the amorphous material, which is markedly increased in ALS skin, includes glycosaminoglycans.

Non-NASA Center↗

Elevated Skin Blood Flow Influences Near Infrared Spectroscopy Measurements During Supine Rest

Near infrared spectroscopy is a non-invasive technique that allows determination of tissue oxygenation/blood flow based on spectrophotometric quantitation of oxy- and deoxyhemoglobin present within a tissue. This technique has gained acceptance as a means of detecting and quantifying changes in tissue blood flow due to physiological perturbation, such as that which is elicited in skeletal muscle during exercise. Since the NIRS technique requires light to penetrate the skin and subcutaneous fat in order to reach the muscle of interest, changes in skin blood flow may alter the NIRS signal in a fashion unrelated to blood flow in the muscle of interest. The aim of this study was to determine the contribution of skin blood flow to the NIRS signal obtained from resting vastus lateralis muscle of the thigh.

Lee, Stuart M. C.↗

Skin Friction at Very High Reynolds Numbers in the National Transonic Facility

Skin friction coefficients were derived from measurements using standard measurement technologies on an axisymmetric cylinder in the NASA Langley National Transonic Facility (NTF) at Mach numbers from 0.2 to 0.85. The pressure gradient was nominally zero, the wall temperature was nominally adiabatic, and the ratio of boundary layer thickness to model diameter within the measurement region was 0.10 to 0.14, varying with distance along the model. Reynolds numbers based on momentum thicknesses ranged from 37,000 to 605,000. The measurements approximately doubled the range of available data for flat plate skin friction coefficients. Three different techniques were used to measure surface shear. The maximum error of Preston tube measurements was estimated to be 2.5 percent, while that of Clauser derived measurements was estimated to be approximately 5 percent. Direct measurements by skin friction balance proved to be subject to large errors and were not considered reliable.

Watson, Ralph D.↗

Protective Skins for Aerogel Monoliths

A method of imparting relatively hard protective outer skins to aerogel monoliths has been developed. Even more than aerogel beads, aerogel monoliths are attractive as thermal-insulation materials, but the commercial utilization of aerogel monoliths in thermal-insulation panels has been inhibited by their fragility and the consequent difficulty of handling them. Therefore, there is a need to afford sufficient protection to aerogel monoliths to facilitate handling, without compromising the attractive bulk properties (low density, high porosity, low thermal conductivity, high surface area, and low permittivity) of aerogel materials. The present method was devised to satisfy this need. The essence of the present method is to coat an aerogel monolith with an outer polymeric skin, by painting or spraying. Apparently, the reason spraying and painting were not attempted until now is that it is well known in the aerogel industry that aerogels collapse in contact with liquids. In the present method, one prevents such collapse through the proper choice of coating liquid and process conditions: In particular, one uses a viscous polymer precursor liquid and (a) carefully controls the amount of liquid applied and/or (b) causes the liquid to become cured to the desired hard polymeric layer rapidly enough that there is not sufficient time for the liquid to percolate into the aerogel bulk. The method has been demonstrated by use of isocyanates, which, upon exposure to atmospheric moisture, become cured to polyurethane/polyurea-type coats. The method has also been demonstrated by use of commercial epoxy resins. The method could also be implemented by use of a variety of other resins, including polyimide precursors (for forming high-temperature-resistant protective skins) or perfluorinated monomers (for forming coats that impart hydrophobicity and some increase in strength).

Leventis, Nicholas↗

Hot Films on Ceramic Substrates for Measuring Skin Friction

Hot-film sensors, consisting of a metallic film on an electrically nonconductive substrate, have been used to measure skin friction as far back as 1931. A hot film is maintained at an elevated temperature relative to the local flow by passing an electrical current through it. The power required to maintain the specified temperature depends on the rate at which heat is transferred to the flow. The heat transfer rate correlates to the velocity gradient at the surface, and hence, with skin friction. The hot-film skin friction measurement method is most thoroughly developed for steady-state conditions, but additional issues arise under transient conditions. Fabricating hot-film substrates using low-thermal-conductivity ceramics can offer advantages over traditional quartz or polyester-film substrates. First, a low conductivity substrate increases the fraction of heat convected away by the fluid, thus increasing sensitivity to changes in flow conditions. Furthermore, the two-part, composite nature of the substrate allows the installation of thermocouple junctions just below the hot film, which can provide an estimate of the conduction heat loss.

Noffz, Greg↗

Global Clear-Sky Surface Skin Temperature from Multiple Satellites Using a Single-Channel Algorithm with Angular Anisotropy Corrections

Surface skin temperature (T(sub s)) is an important parameter for characterizing the energy exchange at the ground/water-atmosphere interface. The Satellite ClOud and Radiation Property retrieval System (SatCORPS) employs a single-channel thermal-infrared (TIR) method to retrieve T(sub s) over clear-sky land and ocean surfaces from data taken by geostationary Earth orbit (GEO) and low Earth orbit (LEO) satellite imagers. GEO satellites can provide somewhat continuous estimates of T(sub s) over the diurnal cycle in non-polar regions, while polar T(sub s) retrievals from LEO imagers, such as the Advanced Very High Resolution Radiometer (AVHRR), can complement the GEO measurements. The combined global coverage of remotely sensed T(sub s), along with accompanying cloud and surface radiation parameters, produced in near-realtime and from historical satellite data, should be beneficial for both weather and climate applications. For example, near-realtime hourly T(sub s) observations can be assimilated in high-temporal-resolution numerical weather prediction models and historical observations can be used for validation or assimilation of climate models. Key drawbacks to the utility of TIR-derived T(sub s) data include the limitation to clear-sky conditions, the reliance on a particular set of analyses/reanalyses necessary for atmospheric corrections, and the dependence on viewing and illumination angles. Therefore, T(sub s) validation with established references is essential, as is proper evaluation of T(sub s) sensitivity to atmospheric correction source. This article presents improvements on the NASA Langley GEO satellite and AVHRR TIR-based T(sub s) product that is derived using a single-channel technique. The resulting clear-sky skin temperature values are validated with surface references and independent satellite products. Furthermore, an empirically adjusted theoretical model of satellite land surface temperature (LST) angular anisotropy is tested to improve satellite LST retrievals. Application of the anisotropic correction yields reduced mean bias and improved precision of GOES-13 LST relative to independent Moderate-resolution Imaging Spectroradiometer (MYD11_L2) LST and Atmospheric Radiation Measurement Program ground station measurements. It also significantly reduces inter-satellite differences between LSTs retrieved simultaneously from two different imagers. The implementation of these universal corrections into the SatCORPS product can yield significant improvement in near-global-scale, near-realtime, satellite-based LST measurements. The immediate availability and broad coverage of these skin temperature observations should prove valuable to modelers and climate researchers looking for improved forecasts and better understanding of the global climate model.

Scarino, Benjamin R.↗

Near-Real Time Ocean-Atmosphere Skin Temperature as Part of NASA GMAO Atmospheric Data Assimilation System

The Global Modeling and Assimilation Office (GMAO) at NASA, GSFC is developing an integrated Earth system analysis (IESA). Integral to this IESA are ocean-atmosphere interface states, such as the skin SST. Recently the GMAO's near-real time operational weather analysis and prediction system implemented an analysis for skin SST along with the meteorological analysis since Jan, 2017. The skin SST is modeled and constrained using infrared radiometric observations. This poster describes some of the details of this development, its impact on forecasts, current and future developments towards the inclusion of microwave data (e.g. GPM-GMI).

SST↗

Balloon fabrics made of Goldbeater's skins

Goldbeater's skin, which is the prepared outside membrane of the large intestine of an ox, is examined as a balloon fabric and details of how goldbeater's skin is prepared for use are provided. The construction techniques employed by Germany, France, and England are all discussed.

FABRICS, GAS - CELL↗

A Method for Obtaining Surface Flow Vectors and Its Implementation in Interferometric Skin Friction Measurement

A new method was developed to extract surface flow vectors from an oilflow visualization image that has oil streaklines. The method is analogous to the PIV processing where the image is divided into interrogation windows. A representative flow direction is obtained for each interrogation window using image processing with a line-detection algorithm. Repeating the process for the entire image, one can find the surface vector field. The Hough transformation, Radon transformation and Machine Learning were used as line-detection algorithms. The obtained vector field is then postprocessed to filter spurious vectors and to apply smoothing. The method was tested on 2D and 3D models with different flow complexities. The method was able to predict surface flow vectors for all cases tested. The predicted surface flow vectors were used in obtaining the surface skin friction. The successful implementation of the surface flow vectors enables interferometric skin friction measurements on surfaces beneath 3D complex flows. In addition, the surface flow vectors can be superimposed on the oilflow visualization images to better explain the surface flow topology.

Surface flow vectors↗

A Method for Obtaining Surface Flow Vectors and Its Implementation in Interferometric Skin Friction Measurement

A new method was developed to extract surface flow vectors from an oilflow visualization image that has oil streaklines. The method is analogous to the PIV processing where the image is divided into interrogation windows. A representative flow direction is obtained for each interrogation window using image processing with a line-detection algorithm. Repeating the process for the entire image, one can find the surface vector field. The Hough transformation, Radon transformation and Machine Learning were used as line-detection algorithms. The obtained vector field is then postprocessed to filter spurious vectors and to apply smoothing. The method was tested on 2D and 3D models with different flow complexities. The method was able to predict surface flow vectors for all cases tested. The predicted surface flow vectors were used in obtaining the surface skin friction. The successful implementation of the surface flow vectors enables interferometric skin friction measurements on surfaces beneath 3D complex flows. In addition, the surface flow vectors can be superimposed on the oilflow visualization images to better explain the surface flow topology.

Surface flow vectors↗

Improved electrodes for skin contacts

Design is described of thick, flexible electrodes with appropriate metal surfaces which prevent unnecessary skin motion. Electrodes provide sufficient radial pressure directed toward body surface to depress skin a noticeable portion of its normal resilient thickness.

Castle, J. G.↗

Pressure-gradient effects on hypersonic turbulent skin friction and boundary-layer profiles.

Local skin friction, total-temperature profiles, and pitot-pressure profiles were measured on the wall of a Mach-7.4 wind tunnel. The wall to adiabatic wall temperature ratio was varied from 0.3 to 0.5. Boundary-layer characteristics were compared with those predicted by a finite-difference method. Local skin friction was predicted to within 15%. Pressure-gradient effects on the temperature and Mach number distributions and the shape factor (displacement thickness/momentum thickness) were underpredicted, but the velocity distributions were closely predicted.

Hopkins, E. J.↗

A general review of concepts for reducing skin friction, including recommendations for future studies

Four main concepts which have significantly reduced skin friction in experimental studies are discussed; suction, gaseous injection, particle additives, and compliant wall. It is considered possible that each of these concepts could be developed and applied in viable skin friction reduction systems for aircraft application. Problem areas with each concept are discussed, and recommendations for future studies are made.

Fischer, M. C.↗