Search NASA⌕ Search

SEARCH · Search NASA

Results for “slice sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Electro-optic techniques in electron beam diagnostics

Electron accelerators such as laser wakefield accelerators, linear accelerators driving free electron lasers, or femto-sliced synchrotrons, are capable of producing femtosecond-long electron bunches. Single-shot characterization of the temporal charge profile is crucial for operation, optimization, and application of such accelerators. A variety of electro-optic sampling (EOS) techniques exists for the temporal analysis. In EOS, the field profile from the electron bunch (or the field profile from its coherent radiation) will be transferred onto a laser pulse co-propagating through an electro-optic crystal. This paper will address the most common EOS schemes and will list their advantages and limitations. Strong points that all techniques share are the ultra-short time resolution (tens of femtoseconds) and the single-shot capabilities. Besides introducing the theory behind EOS, data from various research groups is presented for each technique.

43 PARTICLE ACCELERATORS↗

Methods for ultraviolet excitation microscopy of biological surfaces

Microscopy with Ultraviolet Surface Excitation (MUSE) for use in the classroom to enhance life sciences education and curricula, or for other applications, including without limtiation the operating room, other medical environments, research environments, and low resource environments. MUSE's suitability is based on multiple key factors including its simplicity of use, the incorporation of inexpensive hardware including LED illumination, and very basic tissue preparation. The ultraviolet excitation acts as passive optical sectioning confining the generated fluorescence signal to only a few micrometers below the tissue surface thus eliminating the out of focus signals. This facilitates image capture of tissue microstructure and organization from specimens at the intact or sliced surface arising from varying fluorophore concentration within the different cellular compartments. Although just the tissue auto fluorescence maybe used, image quality is enhanced with brief application of nontoxic fluorescent dyes to selectively highlight cellular compartments. Sample preparation is safe, efficient and familiar to students with basic chemistry or biology lab experience. Mixed-dye powders may be used to simplify translation of this method for educational, medical, research, low resource, and other settings.

Demos, Stavros G.↗

Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner

Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, with radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm). A passing rate of 99% was measured in areas of above 40% of the prescription dose. The final inverse treatment plan was comprised of 43 beams ranging from 5 to 12.5 mm in diameter (2.5 mm size increments are available up to 15 mm in diameter collimation). Using the Xsight Spine Tracking module, the CyberKnife system could not reliably identify and track the tiny mouse spine; however, the CyberKnife system could identify and track the fiducial markers on the 3D mold.In vivo positional accuracy analysis using the 3D mold generated a mean error of 1.41 mm ± 0.73 mm when fiducial markers were used for position tracking. Analysis of the dissected brain confirmed the ability to target the correct brain volume. Conclusions: With the use of a stereotactic body mold with fiducial markers, microCT imaging, and resolution down-sampling, the CyberKnife system can successfully perform small-animal radiotherapy studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy

Purpose: Sparse-sampling and reconstruction techniques represent an attractive strategy to achieve faster image acquisition speeds, while maintaining adequate spatial resolution and signal-to-noise ratio in rapid magnetic resonance imaging (MRI). The authors investigate the use of one such sequence, broad-use linear acquisition speed-up technique (k-t BLAST) in monitoring tumor motion for thoracic and abdominal radiotherapy and examine the potential trade-off between increased sparsification (to increase imaging speed) and the potential loss of “true” information due to greater reliance on a priori information. Methods: Lung tumor motion trajectories in the superior–inferior direction, previously recorded from ten lung cancer patients, were replayed using a motion phantom module driven by an MRI-compatible motion platform. Eppendorf test tubes filled with water which serve as fiducial markers were placed in the phantom. The modeled rigid and deformable motions were collected in a coronal image slice using balanced fast field echo in conjunction with k-t BLAST. Root mean square (RMS) error was used as a metric of spatial accuracy as measured trajectories were compared to input data. The loss of spatial information was characterized for progressively increasing acceleration factor from 1 to 16; the resultant sampling frequency was increased approximately from 2.5 to 19 Hz when the principal direction of the motion was set along frequency encoding direction. In addition to the phantom study, respiration-induced tumor motions were captured from two patients (kidney tumor and lung tumor) at 13 Hz over 49 s to demonstrate the impact of high speed motion monitoring over multiple breathing cycles. For each subject, the authors compared the tumor centroid trajectory as well as the deformable motion during free breathing. Results: In the rigid and deformable phantom studies, the RMS error of target tracking at the acquisition speed of 19 Hz was approximately 0.3–0.4 mm, which was smaller than the reconstructed pixel resolution of 0.67 mm. In the patient study, the dynamic 2D MRI enabled the monitoring of cycle-to-cycle respiratory variability present in the tumor position. It was seen that the range of centroid motion as well as the area covered due to target motion during each individual respiratory cycle was underestimated compared to the entire motion range observed over multiple breathing cycles. Conclusions: The authors’ initial results demonstrate that sparse-sampling- and reconstruction-based dynamic MRI can be used to achieve adequate image acquisition speeds without significant information loss for the task of radiotherapy guidance. Such monitoring can yield spatial and temporal information superior to conventional offline and online motion capture methods used in thoracic and abdominal radiotherapy.

60 APPLIED LIFE SCIENCES↗

Generative Ensemble Regression: Learning Particle Dynamics from Observations of Ensembles with Physics-informed Deep Generative Models

Here, we propose a new method for inferring the governing stochastic ordinary differential equations (SODEs) by observing particle ensembles at discrete and sparse time instants, i.e., multiple “snapshots.” Particle coordinates at a single time instant, possibly noisy or truncated, are recorded in each snapshot but are unpaired across the snapshots. By training a physics-informed generative model that generates “fake” sample paths, we aim to fit the observed particle ensemble distributions with a curve in the probability measure space, which is induced from the inferred particle dynamics. We employ different metrics to quantify the differences between distributions, e.g., the sliced Wasserstein distances and the adversarial losses in generative adversarial networks. We refer to this method as generative “ensemble-regression” (GER), in analogy to the classic “point-regression,” where we infer the dynamics by performing regression in the Euclidean space. We illustrate the GER by learning the drift and diffusion terms of particle ensembles governed by SODEs with Brownian motions and Lévy processes up to 100 dimensions. We also discuss how to treat cases with noisy or truncated observations. Apart from systems consisting of independent particles, we also tackle nonlocal interacting particle systems with unknown interaction potential parameters by constructing a physics-informed loss function. Finally, we investigate scenarios of paired observations and discuss how to reduce the dimensionality in such cases by proving a convergence theorem that provides theoretical support.

97 MATHEMATICS AND COMPUTING↗

Bulk Migration of Ni/NiO in Ni-YSZ during Reducing Conditions

Understanding the migration of Ni/NiO in Ni-YSZ can potentially help to design a better solid oxide fuel cell (SOFC) anode. We have observed that extensive hydrogen reduction and methane steam reforming of Ni-YSZ caused bulk migration of Ni/NiO to at least ~ 5 µm deeper from the Ni-YSZ surface. No significant bulk migration effects were detected after simple thermal treatments in non-reducing/non-reforming environment. Surface analysis of a single zirconia grain in the first 10-20 nm region from annealed, hydrogen reduced and methane steam reformed Ni-YSZ shows Ni-enriched surface supporting earlier claims of Ni exsolution. 3D-EBSD analysis of thermally treated sample before exposing it to reducing and reforming environment indicated mixed NiO/YSZ phase with some porosity and random grain orientation. The surface analysis and mapping were carried out using ToF-SIMS and AES whereas EDS maps on FIB sliced areas on Ni-YSZ were utilized for the bulk analysis. The results provide additional information related to complex reactions occurring in SOFC during internal reforming conditions.

03 NATURAL GAS↗

Nutrient and carbon concentrations in dated soil cores at US-OWC Ameriflux wetland site (OWC NERR)

Soil cores were sampled at the Old Woman Creek (OWC) National Estuarine Research Reserve at the south shore of Lake Erie, near Huron, Ohio, USA. OWC is a temperate mineral soil marsh. We dated the soil cores using lead isotope analysis and measured the concentrations of carbon and nutrients (nitrogen, phosphorus) throughout the core depths. We analyzed 36 cores, sampled along three transects at areas of the wetland with different hydrological regimes. Each transect included three coring sites at different water depth categories (shallow, intermediate deep) with four core samples per coring site. The data can be used to determine the carbon sequestration rates and nutrient accumulation rates, at multiple locations throughout OWC wetland.Dataset, in csv format, with data variables in columns, and different cores and core depths slices in rows, includes results from 36 sediment cores (0-30 cm depth) taken at 9 locations (4 replicates at each location) along 3 gradients of water depth (shallow, intermediate, deep), each at a different hydrologic location (outflow, backflow, middle). At each depth slice within a core, we provide depth, date (using 210Pb), bulk density, and the concentrations of carbon, nitrogen, phosphorus, d13C, and d15N.

54 ENVIRONMENTAL SCIENCES↗

The thin section rock physics: Modeling and measurement of seismic wave velocity on the slice of carbonates

This paper discusses a new approach for investigating the seismic wave velocity of rock, specifically carbonates, as affected by their pore structures. While the conventional routine of seismic velocity measurement highly depends on the extensive laboratory experiment, the proposed approach utilizes the digital rock physics view which lies on the numerical experiment. Thus, instead of using core sample, we use the thin section image of carbonate rock to measure the effective seismic wave velocity when travelling on it. In the numerical experiment, thin section images act as the medium on which wave propagation will be simulated. For the modeling, an advanced technique based on artificial neural network was employed for building the velocity and density profile, replacing image's RGB pixel value with the seismic velocity and density of each rock constituent. Then, ultrasonic wave was simulated to propagate in the thin section image by using finite difference time domain method, based on assumption of an acoustic-isotropic medium. Effective velocities were drawn from the recorded signal and being compared to the velocity modeling from Wyllie time average model and Kuster-Toksoz rock physics model. To perform the modeling, image analysis routines were undertaken for quantifying the pore aspect ratio that is assumed to represent the rocks pore structure. In addition, porosity and mineral fraction required for velocity modeling were also quantified by using integrated neural network and image analysis technique. It was found that the Kuster-Toksoz gives the closer prediction to the measured velocity as compared to the Wyllie time average model. We also conclude that Wyllie time average that does not incorporate the pore structure parameter deviates significantly for samples having more than 40% porosity. Utilizing this approach we found a good agreement between numerical experiment and theoretically derived rock physics model for estimating the effective seismic wave velocity of rock.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-191: Automated Detection of Anatomic Changes in H'N Patients

Purpose: To develop a novel statistics-based method for automated detection of anatomical changes using cone-beam CT data. A method was developed that can provide a reliable and automated early warning system that enables a “just-in-time” adaptation of the treatment plan. Methods: Anatomical changes were evaluated by comparing the original treatment planning CT with daily CBCT images taken prior treatment delivery. The external body contour was computed on a given CT slice and compared against the corresponding contour on the daily CBCT. In contrast to threshold-based techniques, a statistical approach was employed to evaluate the difference between the contours using a given confidence level. The detection tool used the two-sample Kolmogorov-Smirnov test, which is a non-parametric technique that compares two samples drawn from arbitrary probability distributions. 11 H'N patients were retrospectively selected from a clinical imaging database with a total of 186 CBCT images. Six patients in the database were confirmed to have anatomic changes during the course of radiotherapy. Five of the H'N patients did not have significant changes. The KS test was applied to the contour data using a sliding window analysis. The confidence level of 0.99 was used to moderate false detection. Results: The algorithm was able to correctly detect anatomical changes in 6 out of 6 patients with an excellent spatial accuracy as early as at the 14th elapsed day. The algorithm provided a consistent and accurate delineation of the detected changes. The output of the anatomical change tool is easy interpretable, and can be shown overlaid on a 3D rendering of the patient's anatomy. Conclusion: The detection method provides the basis for one of the key components of Adaptive Radiation Therapy. The method uses tools that are readily available in the clinic, including daily CBCT imaging, and image co-registration facilities.

60 APPLIED LIFE SCIENCES↗

Meas. K+ -Ar Total Inelastic Cross Section at ProtoDUNE-SP

ProtoDUNE-SP is a single-phase liquid argon time projection chamber that took hadron test beam data in 2018. The test beam included positively charged kaons with test beam momenta of 6 GeV/c and 7 GeV/c, providing a sample to study kaons to benefit future DUNE proton decay and neutrino interaction studies with kaons in the final state. The total inelastic cross section of a positively charged kaon was measured at these test beam settings using the LArIAT thin-slice method of dividing the wires of the time projection chamber into target slices for calculating the cross section, which leverages the monolithic quality of liquid argon detectors. A Bayesian-like unfolding method using RooUnfold was applied to both the incident and interacting slice distributions to measure the cross sections at both test beam momenta. The talk will discuss the method of unfolding, optimization studies for unfolding, and applying systematic uncertainties using a LArIAT-style hadronic cross section using unfolding to extract a kaon total inelastic cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A weak lensing view of the downsizing of star-forming galaxies

We describe a weak lensing view of the downsizing of star-forming galaxies based on cross-correlating a weak lensing (κ) map with a predicted map constructed from a redshift survey. Moderately deep and high-resolution images with Subaru/Hyper Suprime-Cam covering the 4 deg{sup 2} DLS F2 field provide a κ map with 1 arcmin resolution. A dense complete redshift survey of the F2 field including 12,705 galaxies with R⩽20.6 is the basis for construction of the predicted map. The zero-lag cross-correlation between the κ and predicted maps is significant at the 30σ level. The width of the cross-correlation peak is comparable to the angular scale of rich clusters at z∼0.3, the median depth of the redshift survey. Slices of the predicted map in δz=0.05 redshift bins enable exploration of the impact of structure as a function of redshift. The zero-lag normalized cross-correlation has significant local maxima at redshifts coinciding with known massive X-ray clusters. Even in slices where there are no known massive clusters, there is a significant signal in the cross-correlation originating from lower mass groups that trace the large-scale of the universe. Spectroscopic D{sub n}4000 measurements enable division of the sample into star-forming and quiescent populations. In regions surrounding massive clusters of galaxies, the significance of the cross-correlation with maps based on star-forming galaxies increases with redshift from 5σ at z = 0.3 to 7σ at z=0.5; the fractional contribution of the star-forming population to the total cross-correlation signal also increases with redshift. This weak lensing view is consistent with the downsizing picture of galaxy evolution established from other independent studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses

PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neck lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Executive Micro-CT Low-resolution Summary for Catheter Parts [Slides]

Data scans were performed on a Zeiss Xradia 520 Versa operated by departments 1851 (Philip Noell) and 1819 (James Griego). Sample 1, 2, and 3 Catheters were scanned with a 30 um pixel (low-resolution) to get an overall view of the part. (This does not include the entire height of the catheter assembly.) The following slides show the Z, Y, and X slice plane at a specific cross-hair location. We can perform a higher resolution scan down to —0.7 um pixel size including a limited field of view of ~700 um wide. Slide 5 has some requests for the customer for further scan locations. These catheters were provided to us by Simon Dunham of Weill Cornell Medical College.

59 BASIC BIOLOGICAL SCIENCES↗

Polycrystal Plasticity: Comparison Between Grain - Scale Observations of Deformation and Simulations

Here, the response of polycrystals to plastic deformation is studied at the level of variations within individual grains, and comparisons are made to theoretical calculations using crystal plasticity (CP). We provide a brief overview of CP and a review of the literature, which is dominated by surface observations. The motivating question asks how well does CP represent the mesoscale behavior of large populations of dislocations (as carriers of plastic strain). The literature shows consistently that only moderate agreement is found between experiment and calculation. We supplement this with a current example of microstructure evolution in the interior of a copper sample subjected to tensile deformation. Nondestructive measurements of orientation fields were performed using the near-field high-energy X-ray diffraction microscopy (nf-HEDM) technique at the Advanced Photon Source (APS). Starting at highly ordered grains, a single two-dimensional slice of microstructure containing ~150 grains was followed through multiple strain states, where it tracked lattice rotations and defect accumulation of up to 14% elongation. In accord with the literature, at the scale of individual grains, comparison of observations with CP models indicates reasonable qualitative agreement but significant variations between simulation and experiment are apparent. The conclusion is that in order to be able to quantify the effects of microstructure on the distributions of slip, orientation change, and damage accumulation, the empirically derived constitutive relations used in continuum-scale simulations need to be improved. Equally important will be the development of large-scale simulations of polycrystals that directly model dislocations.

36 MATERIALS SCIENCE↗

SPS Ecloud Instabilities - Analysis of Machine Studies and Implications for Ecloud Feedback

The SPS at high intensities exhibits transverse single bunch instabilities with signatures consistent with an Ecloud driven instability. We present recent MD data from the SPS, details of the instrument technique and spectral analysis methods which help reveal complex vertical motion that develops within a subset of the injected bunch trains. The beam motion is detected via wideband exponential taper striplines and delta-sigma hybrids. The raw sum and difference data is sampled at 50 GHz with 1.8 GHz bandwidth. Sliding window FFT techniques and RMS motion techniques show the development of large vertical tune shifts on portions of the bunch of nearly 0.025 from the base tune of 0.185. Results are presented via spectrograms and bunch slice trajectories to illustrate development of the unstable beam and time scale of development along the injected bunch train. The study shows that the growing unstable motion occupies a very broad frequency band of 1.2 GHz. These measurements are compared to numerical simulation results, and the system parameter implications for an Ecloud feedback system are outlined.

43 PARTICLE ACCELERATORS↗

SPS ECLOUD INSTABILITIES - ANALYSIS OF MACHINE STUDIES AND IMPLICATIONS FOR ECLOUD FEEDBACK

The SPS at high intensities exhibits transverse single-bunch instabilities with signatures consistent with an Ecloud driven instability. They present recent MD data from the SPS, details of the instrument technique and spectral analysis methods which help reveal complex vertical motion that develops within a subset of the injected bunch trains. The beam motion is detected via wideband exponential taper striplines and delta-sigma hybrids. The raw sum and difference data is sampled at 50 GHz with 1.8 GHz bandwidth. sliding window FFT techniques and RMS motion techniques show the development of large vertical tune shifts on portions of the bunch of nearly 0.025 from the base tune of 0.185. Results are presented via spectrograms and bunch slice trajectories to illustrate development of the unstable beam and time scale of development along the injected bunch train. The study shows that the growing unstable motion occupies a very broad frequency band of 1.2 GHz. These measurements are compared to numerical simulation results, and the system parameter implications for an Ecloud feedback system are outlined.

60 APPLIED LIFE SCIENCES↗

El-CID: a filter for gravitational-wave electromagnetic counterpart identification

ABSTRACT As gravitational-wave (GW) interferometers become more sensitive and probe ever more distant reaches, the number of detected binary neutron star mergers will increase. However, detecting more events farther away with GWs does not guarantee corresponding increase in the number of electromagnetic counterparts of these events. Current and upcoming wide-field surveys that participate in GW follow-up operations will have to contend with distinguishing the kilonova (KN) from the ever increasing number of transients they detect, many of which will be consistent with the GW sky-localization. We have developed a novel tool based on a temporal convolutional neural network architecture, trained on sparse early-time photometry and contextual information for Electromagnetic Counterpart Identification (El-CID). The overarching goal for El-CID is to slice through list of new transient candidates that are consistent with the GW sky localization, and determine which sources are consistent with KNe, allowing limited target-of-opportunity resources to be used judiciously. In addition to verifying the performance of our algorithm on an extensive testing sample, we validate it on AT2017gfo – the only EM counterpart of a binary neutron star merger discovered to date – and AT2019npv – a supernova that was initially suspected as a counterpart of the GW event, GW190814, but was later ruled out after further analysis.

79 ASTRONOMY AND ASTROPHYSICS↗