Synergistic Heat Pumped Thermal Storage and Flexibly Carbon Capture System

As the U.S. grid evolves toward a lower-carbon system, fossil generation assets need to operate in energy markets with high variable renewable energy (VRE) penetration while also decreasing carbon emissions. Current carbon capture and storage (CCS) technologies suffer from high capital cost and an inability to operate flexibly during periods of oscillating demand. The ARPA-E FLECCS Program Phase 1 was created to fund designing and optimizing innovative CCS processes that enable flexibility on a high-VRE grid. To address this need, the Colorado State University (CSU) Team won funding to design a synergized system of thermal energy storage, power generation, and flexible carbon capture to enable breakthrough system performance that achieves an LCOE <$75/MWh with >99% capture rate. This approach will target new or existing natural gas combined cycle power plants. The proposed design utilizes novel hot and cold thermal energy storage (TES) technologies that store low-cost, off-peak electricity as thermal energy to power CCS solvent regeneration and boost plant output during periods of peak demand. The design provides an overall optimized net present value (NPV) by maximizing low carbon power to grid while prices are highest using Storworks Power’s concrete TES technology. The team also capitalizes on decades of ION Clean Energy’s (ION) development in low cost and flexible pioneering solvent technology, which has proven reductions in energy consumption and overall cost of 28% and 38%, respectively, compared with state-of-the-art CCS.

20 FOSSIL-FUELED POWER PLANTS↗

Multi-pass flow-through reductive catalytic fractionation

Reductive catalytic fractionation (RCF) is a promising lignin-first biorefining strategy that selectively extracts and depolymerizes lignin from whole biomass. Flow-through (FT)-RCF enables physical separation of the biomass and catalyst, but this process configuration typically operates at high solvent-to-biomass ratios. Here, we demonstrate multi-pass FT-RCF, wherein the lignin-enriched solvent obtained after an initial FT-RCF step is recycled and used in subsequent FT-RCF without intermediate lignin recovery. Multi-pass FT-RCF reduces the solvent-to-biomass ratio from 48 to 1.9 L/kg, which is a lower solvent loading than is accessible in batch reactors, without negative impacts on delignification and monomer yield with up to 12 wt % lignin in the solvent. Overall, this work demonstrates that solvent demand in RCF processes, which is a key cost and energy driver to enable this process at scale, can be reduced by recycling lignin oil between RCF reactions.

09 BIOMASS FUELS↗

Full-Scale Implementation of Propane Biosparge System for In-Situ Remediation of 1,4-Dioxane - 20174

1,4-Dioxane is a common co-contaminant with chlorinated solvents but is not readily remediated via similar treatment approaches (e.g., sorption, reductive dechlorination). However, 1,4-dioxane can be cometabolically biodegraded in the presence of alkane gases and oxygen. At Vandenberg Air Force Base in California, USA, historical use of chlorinated solvents resulted in 1,4-dioxane in groundwater across three vertical groundwater zones. Between April 2013 and December 2016, laboratory testing and various field demonstrations were conducted by us, and others. The results from these tests showed in-situ propane biosparging as a promising technology for reduction of both chlorinated solvent and 1,4-dioxane concentrations, with up to 99 percent reduction in groundwater concentrations. Stable isotope probing (SIP) was also used in 2015 to verify that biodegradation was a (destructive) mechanism occurring in the subsurface.). The success of the propane biosparge demonstrations, and confirmation of the biodegradation mechanism via SIP, has led to the full-scale implementation of a propane biosparge treatment system at Site 24 at Vandenberg Air Force Base. The treatment area is a relatively small footprint (e.g., less than 61 meters (200 feet) long), with 83 new wells installed simultaneously across the three groundwater zones. Ultimately 93 wells will be connected to an above-ground treatment system the includes an air compressor, a propane tank, controls to ensure safe operating conditions, and nutrient amendment elements. This full-scale system is currently known to be among the first of its kind. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical and economic analysis of solvent-based lithium-ion electrode drying with water and NMP

Processing lithium-ion battery (LIB) electrode dispersions with water as the solvent during primary drying offers many advantages over N-methylpyrrolidone (NMP). An in-depth analysis of the comparative drying costs of LIB electrodes is discussed for both NMP- and water-based dispersion processing in terms of battery pack $/kWh. Electrode coating manufacturing and capital equipment cost savings are compared for water vs. conventional NMP organic solvent processing. A major finding of this work is that the total electrode manufacturing costs, whether water- or NMP-based, contribute about 8–9% of the total pack cost. However, it was found that up to a 2 × reduction in electrode processing (drying and solvent recovery) cost can be expected along with a $3–6 M savings in associated plant capital equipment (for a plant producing 100,000 10-kWh Plug-in Hybrid Electric Vehicle (PHEV) batteries) using water as the electrode solvent. This paper shows a different perspective in that the most important benefits of aqueous electrode processing actually revolve around capital equipment savings and environmental stewardship and not processing cost savings.

25 ENERGY STORAGE↗

Gold-Copper alloy “nano-dumplings” with tunable compositions and plasmonic properties

The unique yet tunable optical properties of plasmonic metal nanoparticles have made them attractive targets for a wide range of applications including nanophotonics, molecular sensing, catalysis etc. Such diverse applications that require precisely stable / reproducible plasmonic properties depend sensitively on the particle morphology ie. the shape, size and constituents. Herein, we systematically study the size / shape controlled synthesis of gold-copper “dumpling” shaped alloy nanoparticles by simultaneous reduction of gold and copper salts in the PVP-methanol solute-solvent system, by effectively utilizing the efficient but mild reduction as well as capping abilities of Poly (N-vinylpyrrolidone). Introduction of copper salts not only yielded the alloy nanoparticles, but also slowed down the growth process to maintain high mono-dispersity of the new shapes evolved. Copper and gold has different lattice constants (0.361 and 0.408 nm respectively) and hence doping/addition/replacement of copper atoms to gold FCC unit cell introduces strain into the lattice which is key parameter to the shape evolution in anisotropic nanoparticles. Synthesized alloy nanoparticles were characterized by UV-visible absorption spectroscopy, XRD and TEM imaging.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Charge-mediated cation deposition on metallic surfaces

This work reveals the general mechanisms of Li + cation partial reduction and further deposition under specific electrolyte conditions, and in the proximity of an electrified metal surface. The factors affecting the ion complexation and transport and resultant adsorbed structures are identified for various external electric fields and for several applied voltages. Using ab initio methods, we investigate the relation between solvent–salt structures and dynamics, cation reductive stability, and the existing electric field between electrodes, or under the applied potential if the system is designed as an electrochemical cell. In absence of an applied field, it is found that not only cation but also non-solvated salt deposition on a metallic surface is an endothermic process. However, localized surface polarization orbitals created by an external electric field affect both the thermodynamics and kinetics of the adsorption, leading to a drastic change on the energetic profile; ab initio molecular dynamics simulations describe in detail the underlying mechanisms. Externally applied bias to an electrochemical cell also changes the deposition dynamics: by examining various solvent/salt combinations, we unravel the cation deposition mechanisms at both low and moderately high voltages, determining the relative time scale of each separate process. In this work, different polyhedra formed by the metal cation and its surrounding oxygen atoms appear to be the key indicator driving deposition dynamics at different voltages. Our findings disclose the importance of selecting appropriate voltage windows for stable and uniform growth of metal anode layers, showing the mechanisms leading to impurity formation and non-uniform cation deposition, as well as the role of charged interfacial phenomena in designing stable electrode–electrolyte interfaces.

25 ENERGY STORAGE↗

Slipstream pilot-scale demonstration of a novel amine-based post-combustion technology for carbon dioxide capture from coal-fired power plant flue gas

Post-combustion CO 2 capture (PCC) technology offers flexibility to treat the flue gas from both existing and new coal-fired power plants and can be applied to treat all or a portion of the flue gas. Solvent-based technologies are today the leading option for PCC from commercial coal-fired power plants as they have been applied in large-scale in other applications. Linde and BASF have been working together to develop and further improve a PCC process incorporating BASF’s novel aqueous amine-based solvent technology. This technology offers significant benefits compared to other solvent-based processes as it aims to reduce the regeneration energy requirements using novel solvents that are very stable under the coal-fired power plant feed gas conditions. BASF has developed the desired solvent based on the evaluation of a large number of candidates. In addition, long-term small pilot-scale testing of the BASF solvent has been performed on a lignite-fired flue gas. In coordination with BASF, Linde has evaluated a number of options for capital cost reduction in large engineered systems for solvent-based PCC technology. This report provides a summary of the work performed and results from a project supported by the US DOE (DE-FE0007453) for the pilot-scale demonstration of a Linde-BASF PCC technology using coal-fired power plant flue gas at a 1-1.5 MWe scale in Wilsonville, AL at the National Carbon Capture Center (NCCC). Following a project kick-off meeting in November 2011 and the conclusion of pilot plant design and engineering in February 2013, mechanical completion of the pilot plant was achieved in July 2014, and final commissioning activities were completed to enable start-up of operations in January 2015. Parametric tests were performed from January to December 2015 to determine optimal test conditions and evaluate process performance over a variety of operation parameters. A long-duration 1500-hour continuous test campaign was performed from May to August 2016 at a selected process condition to evaluate process performance and solvent stability over a longer period similar to how the process would operate as a continuously running large-scale PCC plant. The pilot plant integrated a number of unique features of the Linde-BASF technology aimed at lowering overall energy consumption and capital costs. During the overall test period including startup, parametric testing and long-duration testing, the pilot plant was operated for a total of 6,764 hours out of which testing with flue gas was performed for 4,109 hours. The pilot plant testing demonstrated all of the performance targets including CO 2 capture rate exceeding 90%, CO 2 purity exceeding 99.9 mol% (dry), flue gas processing capacity up to 15,500 lbs/hr (equivalent to 1.5 MWe capacity slipstream), regeneration energy as low as 2.7 GJ/tonne CO 2 , and regenerator operating pressure up to 3.4 bara. Excellent solvent stability performance data was measured and verified by Linde and BASF during both test campaigns. In addition to process data, significant operational learnings were gained from pilot tests that will contribute greatly to the commercial success of PCC. Based on a thorough techno-economic assessment (TEA) of the Linde-BASF PCC process integrated with a 550 MWe supercritical coal-fired power plant, the net efficiency of the integrated power plant with CO 2 capture is increased from 28.4% with the DOE/NETL Case 12 reference to 30.9% with the Linde-BASF PCC plant previously presented utilizing the BASF OASE® blue solvent [Ref. 4], and is further increased to 31.4% using a Linde-BASF PCC plant with BASF OASE® blue solvent and an advanced stripper interstage heater (SIH) configuration. The Linde-BASF PCC plant incorporating the BASF OASE® blue solvent also results in significantly lower overall capital costs, thereby reducing the cost of electricity (COE) and cost of CO 2 captured from $147.25/MWh and $56.49/MT CO 2 , respectively, for the reference DOE/NETL Case 12 plant, to $128.49/MWh and $41.85/MT CO2 for process case LB1, respectively, and $126.65/MWh and $40.66/MT CO 2 for process case SIH, respectively. With additional innovative Linde-BASF PCC process configuration improvements, the COE and cost of CO 2 captured can be further reduced to $125.51/MWh and $39.90/MT CO 2 for a further optimized PCC process defined as LB1-CREB. Most notably, the Linde-BASF process options assessed have already demonstrated the potential to lower the cost of CO 2 captured below the DOE target of $40/MT CO 2 at the 550 MWe scale for second generation PCC technologies. Project organization, structure, goals, tasks, accomplishments, process criteria and milestones will be presented in this report along with highlights and key results from parametric and long-duration testing of the Linde-BASF PCC pilot. The parametric and long-duration testing campaigns were aimed at validating the performance of the PCC technology against targets determined from a preliminary techno-economic assessment. The stability of the solvent with extended operation in a realistic power plant setting was measured with performance verified. Additionally, general solvent classification information, process operating conditions, normalized solvent performance data, solvent stability test results, flue gas conditions data, CO 2 purity data in the gaseous product stream, steam requirements and process flow diagrams, and updated process economic data for a scaled-up 550 MWe supercritical power plant with CO 2 capture are presented and discussed in this report.

20 FOSSIL-FUELED POWER PLANTS↗

Compact Absorber Technology Leads to Significant Reduction in the Cost of Point Source CO 2 Capture

The size of columns in traditional absorption-based processes for CO 2 capture contributes significantly to the overall capital cost. A demonstrated method to reduce the cost of point source CO 2 capture, focusing on reducing the absorber height by increasing the liquid-to-gas reaction contact area and decreasing the CO 2 diffusion resistance without increasing gas-side pressure drop is presented along with techno-economic analysis results. Bench-scale tests on the unique Compact Absorber showed overall CO 2 mass transfer enhancement of varying degrees compared to a traditional packed column for similar process conditions, demonstrating that a 60+% reduction in size of a typical post-combustion absorber with a packing height of 70-100 ft and total height of 150-180 ft can be achieved. The techno-economic analysis showed significant cost reductions when the Compact Absorber is combined with other transformative aspects of the University of Kentucky Institute for Decarbonization and Energy Advancement point source CO 2 capture process compared to the U.S. Department of Energy National Energy Technology Laboratory pertinent reference case for pulverized coal plants with CO 2 capture. Here, a levelized cost of electricity excluding CO 2 transportation and storage of $\$95.6$/MWh was estimated, which is a 9% reduction, with a total capital cost contribution of $45/MWh, which is a 12% reduction. Additionally, a breakeven CO 2 sales price also referred to as the cost of CO 2 capture, of $36.70/tonne was estimated when the UK hindered primary amine solvent is used, which is a 20% reduction compared to the reference case.

CO2 capture↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Synergistic Solvent-Surface Interactions Enable Alkyne Semihydrogenation at Palladium

Enabling higher yield and better selectivity for fine-chemical synthesis through heterogeneous catalysis is intricately linked to the interplay of active sites, reaction conditions, and mass transfer influence provided by the catalyst. Alkyne semihydrogenation is ubiquitous in the production of bulk chemicals in the pharmaceutical, polymer, or fine-chemical industries, but product selectivity remains a major challenge. Here, in this study, we demonstrate that the design of catalysts encompassing nickel (Ni) foams as contiguous monolith supports, decorated with ultralow loading of Pd/PdO x nanoparticles on a carbonized polydopamine interface and tuned with a thin layer of Al 2 O 3 , in conjunction with an optimized reaction environment leads to highly selective alkyne semihydrogenation. The reactions demonstrate good functional group tolerance and applicability to flow reactor systems. Combined computational and experimental studies are presented to describe the synergistic effect between the solvent-surface interaction and the degree of Pd surface reduction that are necessary to promote this selectivity. The system highlights the opportunity for catalyst-solvent codesign as a benign alternative to more complex reactants featuring extrinsic poisons or less-favored dopants.

atomic layer deposition↗

Sulfone-Based Electrolytes for Next Generation Lithium Batteries

An electrolyte system based on a sulfone solvent will be presented, outlining a newly discovered synergy between solvent and salt that simultaneously addresses the interfacial requirements of coupling a graphitic anode with a high voltage spinel cathode (LNMO). At the anode, a LiF-rich interphase generated by early-onset reduction of the salt anion effectively suppresses solvent co-intercalation and subsequent graphite exfoliation, enabling unprecedented and highly reversible graphite cycling in a pure sulfone system. Under aggressively oxidative conditions, QC calculations predict that high salt concentration promotes formation of complexes/aggregates which slow the decomposition of the solvent and leads to polymerizable rather than gaseous byproducts--a fundamental improvement over conventional electrolytes. These predictions are corroborated by an in-depth analysis of these functional interphases, as well as stable, long term operation of high voltage (4.85V) LNMO-graphite full cells.

Schroeder, Marshall A.↗

Structure and component dynamics in binary mixtures of poly(2-(dimethylamino)ethyl methacrylate) with water and tetrahydrofuran: A diffraction, calorimetric, and dielectric spectroscopy study

We have combined X-ray diffraction, neutron diffraction with polarization analysis, small angle neutron scattering, differential scanning calorimetry, and broad band dielectric spectroscopy to investigate the structure and dynamics of binary mixtures of poly (2-(dimethylamino)ethyl methacrylate) with either water or tetrahydrofuran (THF) at different concentrations. Aqueous mixtures are characterized by a highly heterogeneous structure where water clusters coexist with an underlying nano-segregation of main chains and side groups of the polymeric matrix. THF molecules are homogeneously distributed among the polymeric nano-domains for concentrations of one THF molecule/monomer or lower. A more heterogeneous situation is found for higher THF amounts, but without evidences for solvent clusters. In THF-mixtures, we observe a remarkable reduction of the glass-transition temperature which is enhanced with increasing amount of solvent but seems to reach saturation at high THF concentrations. Adding THF markedly reduces the activation energy of the polymer β-relaxation. The presence of THF molecules seemingly hinders a slow component of this process which is active in the dry state. The aqueous mixtures present a strikingly broad glass-transition feature, revealing a highly heterogeneous behavior in agreement with the structural study. Regarding the solvent dynamics, deep in the glassy state all data can be described by an Arrhenius temperature dependence with a rather similar activation energy. However, the values of the characteristic times are about three orders of magnitude smaller for THF than for water. Water dynamics display a crossover toward increasingly higher apparent activation energies in the region of the onset of the glass transition, supporting its interpretation as a consequence of the freezing of the structural relaxation of the surrounding matrix. The absence of such a crossover (at least in the wide dynamic window here accessed) in THF is attributed to the lack of cooperativity effects in the relaxation of these molecules within the polymeric matrix.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nitrogen-doped and simultaneously reduced graphene oxide with superior dispersion as electrocatalysts for oxygen reduction reaction

Nitrogen doped graphene oxide (Nr-GO) with properties suitable for electrocatalysts is easily synthesized using phenylhydrazine as a reductant at relatively low temperature. The reducing agent removes various oxygen functional groups bonded to graphene oxide and simultaneously dope the nitrogen atoms bonded with phenyl group all over the basal planes and edge sites of the graphene. The Nr-GO exhibits remarkable electrocatalytic activities for oxygen reduction reaction compared to the commercial carbon black and graphene oxide due to the electronic modification of the graphene structure. In addition, Nr-GO shows excellent dispersibility in various solvent due to the dopant molecules.

36 MATERIALS SCIENCE↗

Direct Coal -to-Liquids (CTL) for Jet Fuel Using Biomass-Derived Solvents

Battelle has demonstrated a novel and potentially breakthrough technology for a direct coal-to-liquids (CTL) process for producing jet fuel using biomass-derived coal solvents (bio-solvents). The Battelle process offers a significant reduction in capital and operating costs and a substantial reduction in greenhouse gas (GHG) emissions, without requiring carbon capture and storage (CCS). The results of the project are the advancement of three steps of the hybrid coal/biomass-to-jet fuel process to the technology readiness level (TRL) of 5. The project objectives were achieved over two phases. In Phase 1, all three major process steps were explored and refined at bench-scale, including: (1) biomass conversion to high hydrogen-donor bio-solvent; (2) coal dissolution in biomass-derived bio-solvent, without requiring molecular H 2 , to produce a synthetic crude (syncrude); and (3) two-stage catalytic hydrotreating/hydrogenation of syncrude to jet fuel and other distillates. In Phase 2, all three subsystems of the CTL process were scaled up to a pre-pilot scale, and an economic analysis was carried out. A total of over 40 bio-solvents were identified and prepared. The most unique attribute of Battelle’s bio-solvents is their ability to provide much-needed hydrogen to liquefy coal and thus increase its hydrogen content so much that the resulting syncrude is liquid at room temperature. Based on the laboratory-scale testing with bituminous coals from Ohio and West Virginia, a total of 12 novel bio-solvent met the goal of greater than 80% coal solubility, with 8 bio-solvents being as good as or better than a well-known but expensive hydrogen-donor solvent, tetralin. The Battelle CTL process was then scaled up to 1 ton/day (1TPD) at a pre-pilot facility operated in Morgantown, WV. These tests were conducted, in part, to produce enough material for syncrude-upgrading testing. To convert the Battelle-CTL syncrude into a form suitable as a blending stock for jet turbine fuel, a two-step catalytic upgrading process was developed at laboratory scale and then demonstrated at pre-pilot scale facility in Pittsburg, PA. Several drums of distillate products were produced, which were then distilled into unblended (neat) synthetic jet fuel and diesel products for a detailed characterization. Based on a detailed characterization of the synthetic jet fuel, a 20% synthetic, 80% commercial jet fuel blend was prepared, which met all specifications. An analysis of the synthetic diesel product showed that it has the promise of being a drop-in fuel as super-low (less than 15 ppm)-sulfur diesel fuel. A detailed economic analysis showed that the Battelle liquefaction process is economical at between 1000 metric tons/day (MT/day) and 2000 MT/day. The unit capital cost for Battelle CTL process for making jet fuel is 50K USD/daily bbl compared to 151K USD/daily bbl for indirect CTL, based on 2011 dollars. The jet-fuel selling cost at the refinery, including a 12% capital cost factor (which included profit), for the Battelle CTL process is 61USD/bbl (1.45 USD/gallon). This is competitive with crude oil price of 48 USD/bbl. At the same time, the GHG emissions of 3.56 MT CO 2 /MT fuel were lower than the GHG emissions of 3.79 MT CO 2 /MTfuel for petroleum-based fuels and 7.77 MT CO 2 /MT fuel for indirect CTL. Thus, the use of bio-solvents completely eliminates the need for carbon capture in the case of Battelle CTL process. The superior economics and low GHG emissions for the Battelle CTL process has thus sparked worldwide interest and some potential commercialization opportunities are emerging.

01 COAL, LIGNITE, AND PEAT↗

Analysis of the Structural Determinants Underlying Discrimination Between Substrate and Solvent in β-Phosphoglucomutase Catalysis

The {Beta}-phosphoglucomutase ({Beta}-PGM) of the haloacid dehalogenase enzyme superfamily (HADSF) catalyzes the conversion of {Beta}-glucose 1-phosphate ({Beta}G1P) to glucose 6-phosphate (G6P) using Asp8 of the core domain active site to mediate phosphoryl transfer from {Beta}-glucose 1,6-(bis)phosphate ({Beta}G1,6bisP) to {Beta}G1P. Herein, we explore the mechanism by which hydrolysis of the {Beta}-PGM phospho-Asp8 is avoided during the time that the active site must remain open to solvent to allow the exchange of the bound product G6P with the substrate {Beta}G1P. On the basis of structural information, a model of catalysis is proposed in which the general acid/base (Asp10) side chain moves from a position where it forms a hydrogen bond to the Thr16-Ala17 portion of the domain-domain linker to a functional position where it forms a hydrogen bond to the substrate leaving group O and a His20-Lys76 pair of the cap domain. This repositioning of the general acid/base within the core domain active site is coordinated with substrate-induced closure of the cap domain over the core domain. The model predicts that Asp10 is required for general acid/base catalysis and for stabilization of the enzyme in the cap-closed conformation. It also predicts that hinge residue Thr16 plays a key role in productive domain-domain association, that hydrogen bond interaction with the Thr16 backbone amide NH group is required to prevent phospho-Asp8 hydrolysis in the cap-open conformation, and that the His20-Lys76 pair plays an important role in substrate-induced cap closure. The model is examined via kinetic analyses of Asp10, Thr16, His20, and Lys76 site-directed mutants. Replacement of Asp10 with Ala, Ser, Cys, Asn, or Glu resulted in no observable activity. The kinetic consequences of the replacement of linker residue Thr16 with Pro include a reduced rate of Asp8 phosphorylation by {Beta}G1,6bisP, a reduced rate of cycling of the phosphorylated enzyme to convert {Beta}G1P to G6P, and an enhanced rate of phosphoryl transfer from phospho-Asp8 to water. The X-ray crystal structure of the T16P mutant at 2.7 {angstrom} resolution provides a snapshot of the enzyme in an unnatural cap-open conformation where the Asp10 side chain is located in the core domain active site. The His20 and Lys76 site-directed mutants exhibit reduced activity in catalysis of the Asp8-mediated phosphoryl transfer between {Beta}G1,6bisP and {Beta}G1P but no reduction in the rate of phospho-Asp8 hydrolysis. Taken together, the results support a substrate induced-fit model of catalysis in which {Beta}G1P binding to the core domain facilitates recruitment of the general acid/base Asp10 to the catalytic site and induces cap closure.

08 HYDROGEN↗

Untapped Potential of Fluoride Ions in Maximizing the Electrochemical Stability of Deep Eutectic Solvents

Advancing the batteries is pivotal to propelling our society toward a sustainable, electrified future. The stability of electrolytes forms the backbone of energy storage systems. This is particularly the case for redox flow batteries (RFBs). Their deployability depends on their longevity and dependability. The presence of unstable electrolytes can trigger undesirable reactions, degrade performance, and lead to battery failure. Aqueous electrolytes, with limited electrochemical stability window (ESW), are prone to hydrogen and oxygen evolution. Conversely, non-aqueous electrolytes offer enhanced stability. In this study, we unveil the ESW of a non-aqueous eutectic solvent, comprising choline fluoride and ethylene glycol—a composition that has eluded experimental investigation until now. Our findings show that the stability window, reduction and oxidation potential limits of deep eutectic solvents, are sensitive to variations in the halide component of the ammonium salt. Furthermore, this work not only highlights the benefits of novel deep eutectic solvents but also sets the stage for their strategic use in future battery electrolytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗