Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Spectral Narrowing Accompanies Enhanced Spatial Resolution in Saturated Coherent Anti-Stokes Raman Scattering (CARS): Comparisons of Experiment and Theory

Here, we demonstrate theoretically and confirm experimentally the mechanism by which spectral narrowing accompanies enhanced spatial resolution in a saturated coherent anti-Stokes Raman scattering (CARS) signal that is demodulated at the third harmonic (3$f$) of the pump modulation frequency ($f$). Under these modulation conditions, theory predicts a narrowing of the full-width at half-maximum (FWHM) of the CARS spectrum by a factor of 2.0 with respect to that of the spectrum obtained by demodulation at the fundamental frequency. Theory also predicts an improvement of spatial resolution by a factor of 1.7. Experimentally, narrowing of the FWHM of the CARS spectrum of 1,4-bis((E)-2-methylstyryl) benzene (MSB) crystals by a factor of 2.5 is observed upon saturation. Further experimental confirmation is provided from investigating diamond particles, for which spectral narrowing was enhanced by a factor of 2.8 and spatial resolution was enhanced by a factor of 2. Details of the mechanism and execution of the saturated CARS experiment are elucidated and limits to its applicability are suggested, one of which is the conclusion that the saturation approach is not suitable for extraction of harmonics beyond 3$f$ . In this work we have developed a more comprehensive understanding of the correlation between the observed experimental results and experimental factors than has been previously reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance comparisons between information extraction techniques using variable spatial resolution data

The decreased instantaneous field of view (IFOV) is one of the principal advances noted for the Thematic Mapper (TM) sensor. The 42.5 microradian IFOV of TM and the 710 km nominal orbit altitude result in a 30 m nominal spatial resolution at the earth surface. This is a considerable decrease in the projected pixel area when compared to the 79 m nominal spatial resolution of the Landsat Multispectral Scanner (MSS). An experiment was conducted which allowed a rigorous test of the influence of classifier design, with data spatial resolution of TM (30 m) and approximately that of the Landsat MSS (90 m), on classification performance for a particular TM scene. The experiment involved evaluation of the results for the per-point Gaussian maximum likelihood (GML) classifier and the supervised ECHO (Extraction and Classification of Homogeneous Objects) classifier.

Latty, R. S.↗

WHY IS NON-THERMAL LINE BROADENING OF SPECTRAL LINES IN THE LOWER TRANSITION REGION OF THE SUN INDEPENDENT OF SPATIAL RESOLUTION?

Spectral observations of the solar transition region (TR) and corona show broadening of spectral lines beyond what is expected from thermal and instrumental broadening. The remaining non-thermal broadening is significant (5–30 km s{sup −1}) and correlated with intensity. Here we study spectra of the TR Si iv 1403 Å line obtained at high resolution with the Interface Region Imaging Spectrograph (IRIS). We find that the large improvement in spatial resolution (0.″33) of IRIS compared to previous spectrographs (2″) does not resolve the non-thermal line broadening which, in most regions, remains at pre-IRIS levels of about 20 km s{sup −1}. This invariance to spatial resolution indicates that the processes behind the broadening occur along the line-of-sight (LOS) and/or on spatial scales (perpendicular to the LOS) smaller than 250 km. Both effects appear to play a role. Comparison with IRIS chromospheric observations shows that, in regions where the LOS is more parallel to the field, magneto-acoustic shocks driven from below impact the TR and can lead to significant non-thermal line broadening. This scenario is supported by MHD simulations. While these do not show enough non-thermal line broadening, they do reproduce the long-known puzzling correlation between non-thermal line broadening and intensity. This correlation is caused by the shocks, but only if non-equilibrium ionization is taken into account. In regions where the LOS is more perpendicular to the field, the prevalence of small-scale twist is likely to play a significant role in explaining the invariance and correlation with intensity. (letters)

79 ASTRONOMY AND ASTROPHYSICS↗

High spatial resolution neutron imaging of lithium-ion batteries: Correlating microstructure and lithium transport

Thick electrodes for lithium-ion batteries can increase the overall energy density, but increasing the electrode thickness introduces charge transport limitations. These limitations may be mitigated through proper electrode structuring. Here, high spatial resolution neutron imaging was used to understand the correlation between microstructure and lithium transport in lithium-ion anodes. Batteries with distinct graphite anode microstructures were produced and studied with high spatial resolution in operando neutron radiography to observe the effects of structure on transport. High spatial resolution neutron computed tomography was performed following in operando neutron radiography. X-ray computed tomography and scanning electron microscopy were used to observe the finer scale anode structure to complement neutron imaging. Solvent-free anodes containing a tightly-packed layered structure confined lithium movement close to the separator. This structure limited capacity, but supported better rate capability. Conversely, a more open pore structure in the wet cast anodes yielded higher capacity with reduced rate capability. Together, these results show that lithium distributions can be controlled by the macroscopic structure of the electrodes, the microstructural pore network, and the microscale active areas that support electrochemical reactions. Furthermore, multimodal imaging applying the complementary strengths of neutron and X-ray methods is shown as a tool for advancing battery design.

25 ENERGY STORAGE↗

Improving Imaging Instrument Spatial Resolution Using Software

In order to overcome spatial resolution limitations associated with physical sensor limitations when using smallsats and cubesats, we utilize an image processing technology referred to as Super-Resolution (SR). In general, software approaches are increasingly considered in connection with smaller satellites for which size, mass and power constraints limit the sensor capabilities. Being able to perform hardware vs. software trades might enable more capabilities for a lower cost. This paper describes recent experiments conducted to optimize the spatial enhancement of acquired observations using multiple sub-pixel shifted low resolution image.

Image Processing↗

Superior spatial resolution in confocal X-ray techniques using collimating channel array optics: elemental mapping and speciation in archaeological human bone

Confocal X-ray fluorescence imaging (CXFI) and confocal X-ray absorption spectroscopy (CXAS) respectively enable the study of three dimensionally resolved localization and speciation of elements. Applied to a thick sample, essentially any volume element of interest within the X-ray fluorescence escape depth can be examined without the need for physical thin sectioning. To date, X-ray confocal detection generally has employed a polycapillary optic in front of the detector to collect fluorescence from the probe volume formed at the intersection of its focus with the incident microfocus beam. This work demonstrates the capability of a novel Collimating Channel Array (CCA) optic in providing an improved and essentially energy independent depth resolution approaching 2 μm. By presenting a comparison of elemental maps of archaeological bone collected without confocal detection, and with polycapillary- and CCA-based confocal detection, this study highlights the strengths and limitations of each mode. Unlike the polycapillary, the CCA shows similar spatial resolution in maps for both low (Ca) and high (Pb and Sr) energy X-ray fluorescence, thus illustrating the energy independent nature of the CCA optic resolution. While superior spatial resolution is demonstrated for all of these elements, the most significant improvement is observed for Ca, demonstrating the advantage of employing the CCA optic in examining light elements. In addition to CXFI, this configuration also enables the collection of Pb L3 CXAS data from micro-volumes with dimensions comparable to bone microstructures of interest. Our CXAS result, which represents the first CCA-based biological CXAS, demonstrates the ability of CCA optics to collect site specific spectroscopic information. The demonstrated combination of site-specific elemental localization and speciation data will be useful in diverse fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Land cover classification accuracy as a function of sensor spatial resolution

The benefits obtained from sensor systems for monitoring earth resources will depend on the application and interpretation methods used. A frequently used analysis method is supervised per-pixel multispectral classification with a typical application being land cover classification. An investigation is conducted to evaluate the effect of spatial resolution on the ability to classify land cover types with per-pixel digital image classification techniques. Attention is also given to the documentation of changes in scene noise and the percentage of boundary pixels as a function of spatial resolution, in order to improve the understanding of the interrelationship between classification accuracy and spatial resolution. It is found that scene noise varies considerably between land cover categories. Changes in scene noise with coarsening resolution occur at different rates for different categories.

Markham, B. L.↗

Pushing the limits: characterisation and performance of the prototype multilayer Laue lenses fluorescence microscope with a view to achieve nm-scale spatial resolution

Synchrotron based x-ray microscopy established itself as a prominent tool for noninvasive investigations in many areas of science and technology. Many facilities around the world routinely achieve sub-micrometer resolution with a few instruments capable of imaging with the spatial resolution better than 100 nm. With an ongoing effort to push the 2D/3D resolution down to 10 nm in the hard x-ray regime both fabrication of the nano-focusing optics and stability of a microscope become extremely challenging. In this work we present our approach to overcome technical challenges on the path towards high spatial resolution hard x-ray microscopy and demonstrate the performance of a scanning fluorescence microscope equipped with the multilayer Laue lenses focusing optics. We utilised the Imaging and Coherence beamline (I13) at Diamond Light Source to perform X-ray testing of the scanning microscope.

36 MATERIALS SCIENCE↗

Linear mixing model applied to coarse spatial resolution data from multispectral satellite sensors

A linear mixing model was applied to coarse spatial resolution data from the NOAA Advanced Very High Resolution Radiometer. The reflective component of the 3.55-3.95 micron channel was used with the two reflective channels 0.58-0.68 micron and 0.725-1.1 micron to run a constrained least squares model to generate fraction images for an area in the west central region of Brazil. The fraction images were compared with an unsupervised classification derived from Landsat TM data acquired on the same day. The relationship between the fraction images and normalized difference vegetation index images show the potential of the unmixing techniques when using coarse spatial resolution data for global studies.

Holben, Brent N.↗

Estimation of reactogenicity of preparations produced on the basis of photoinactivated live vaccines against brucellosis and tularaemia on the organismic level. 2. Using the method of speckle-microscopy with high spatial resolution

The method of speckle microscopy was adapted to estimate the reactogenicity of the prototypes of vaccine preparations against extremely dangerous infections. The theory is proposed to describe the mechanism of formation of the output signal from the super-high spatial resolution speckle microscope. The experimental studies show that bacterial suspensions, irradiated in different regimes of inactivation, do not exert negative influence on the blood microcirculations in laboratory animals. (optical technologies in biophysics and medicine)

60 APPLIED LIFE SCIENCES↗

High spatial-resolution IRAS images of M51

High spatial-resolution (approx. equal to 30 seconds) images of M51 in the four Infrared Astronomy Satellite (IRAS) bands (12, 25, 60, and 100 microns) have been obtained. The spatial variation in flux in all four bands is coincident with the spiral features seen in H alpha and 6 cm with a few exceptions. In the nuclear region (4 minutes) the position of the peak of maximum intensity shifts in relation to the visual nucleus: it is coincident with the nucleus at 12 microns, shifts approximately 45 seconds to south-southwest, and is 45 seconds northwest of the nucleus at 60 and 100 microns.

Canterna, R.↗

Spatially Resolved Mapping of Three-Dimensional Molecular Orientations with ~2 nm Spatial Resolution through Tip-Enhanced Raman Scattering

We record local optical field images of silver nanocubes (75 nm) using tip-enhanced Raman (TER) spectral imaging. The images that we observe are consistent with several recent reports from our group, but here, we demonstrate sub-2 nm spatial resolution in local optical field nanoimaging under ambient laboratory conditions. This is achieved by scanning the substrate (nanocube on Si) relative to a 4-thiobenzonitrile (TBN)-functionalized Ag-coated TER probe. The spatial resolution that we obtain necessitates that only a few molecules govern the recorded optical response; molecular orientation becomes an important consideration in such measurements. We model the orientation through geometry optimization of a TBN molecule chemisorbed onto an Ag79 cluster (sphere with a ~1 nm diameter). Using the computed orientation of the cluster-bound molecule, we then model the optical response using formalism that accounts for the orientation of the molecule relative to vector components of the local optical fields. We find optimal agreement between experiment and theory. In effect, this work reveals the parallels between single-molecule Raman scattering and high-spatial-resolution TER spectroscopy, even when the images themselves cannot be used to visualize a single molecule in real space.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Achieving Large-Scale, High-Resolution, Full Shell Replicated X-Ray Optics: Budgeting for Sources of Spatial Resolution Errors

Technology for a large-area, high-angular resolution mirror module for a future Great Observatory x-ray mission is progressing along different paths. To date, none of these are fully developed. Work at the Marshall Space Flight Center (MSFC) seeks to leverage the benefits of full shell optics while exploring the limits of using shell replication technology for optics production. Here, we provide an updated accounting of spatial-resolution-constraining error terms to give context to recent improvements in MSFC replicated optics, as well as guidance and justification for current and future directions of research. Content includes strawman error allocations for an optical system that is parametrically Lynx-like, where the replicated-optics technology stands relative to these allocations, and methodology for mapping development plans to efficiently identify the limiting factors and approaches to overcoming these.

error budget↗

Technological and optical methods for increasing the spatial resolution of thermochemical laser writing on thin metal films

Various techniques, effects, and factors are examined that enable one to increase the spatial resolution of thermochemical direct laser writing on thin metal films. A few specific conditions of experimental laser processing with the focused beam of a CW green laser are investigated therewith. One of the goals of this work was to find a suitable metal and its thickness that would make it possible to implement the through-oxidation regime. When properly adjusting a value of laser exposure, this regime was found to be very useful for increasing the spatial resolution of the laser writing. This is due to bleaching of an oxidized film near the peak of a focused laser spot. Apart from the experimental results concerning the technology of laser processing of the metal films, in this work, there are also considered some ways of reducing a focused spot size used for the direct laser writing.

36 MATERIALS SCIENCE↗

Selecting the spatial resolution of satellite sensors required for global monitoring of land transformations

The paper provides preliminary evidence for the spatial resolutions required to monitor land transformations at broad scales. This is obtained from simulations of imagery at various spatial resolutions between 125 and 4000 m derived from Landsat MSS imagery. Consideration is given to the various types of spatial images detectable by remotely-sensed systems, as well as to the difficulties associated in disentangling permanent land transformations from shorter term changes such as phenological and interannual changes.

Townshend, J. R. G.↗

High spatial resolution direct conversion amorphous selenium X-ray detectors with monolithically integrated CMOS readout

Recent progress in the field of micron-scale spatial resolution direct conversion X-ray detectors for high-energy synchrotron light sources serve applications ranging from nondestructive and noninvasive microscopy techniques which provide insight into the structure and morphology of crystals, to medical diagnostic measurement devices. Amorphous selenium ( a -Se) as a wide-bandgap thermally evaporated photoconductor exhibits ultra-low thermal generation rates for dark carriers and has been extensively used in X-ray medical imaging. Being an amorphous material, it can further be deposited over large areas at room temperatures and at substantially lower costs as compared to crystalline semiconductors. Here, to address the demands for a high-energy and high spatial resolution X-ray detector for synchrotron light source applications, we have thermally evaporated a -Se on a Mixed-Mode Pixel Array Detector (MM-PAD) Application Specific Integrated Circuit (ASIC). The ASIC format consists of 128 × 128 square pixels each 150 μm on a side. A 200 μm a -Se layer was directly deposited on the ASIC followed by a metal top electrode. The completed detector assembly was tested with 45 kV Ag and 23 kV Cu X-ray tube sources. The detector fabrication, performances, Modulation Transfer Function (MTF) measurements, and simulations are reported.

36 MATERIALS SCIENCE↗

High-spatial-resolution mapping of catalytic reactions on single particles

We report the critical role in surface reactions and heterogeneous catalysis of metal atoms with low coordination numbers, such as found at atomic steps and surface defects, is firmly established. But despite the growing availability of tools that enable detailed in situ characterization, so far it has not been possible to document this role directly. Surface properties can be mapped with high spatial resolution, and catalytic conversion can be tracked with a clear chemical signature; however, the combination of the two, which would enable high-spatial-resolution detection of reactions on catalytic surfaces, has rarely been achieved. Single-molecule fluorescence spectroscopy has been used to image and characterize single turnover sites at catalytic surfaces, but is restricted to reactions that generate highly fluorescing product molecules. Herein the chemical conversion of N-heterocyclic carbene molecules attached to catalytic particles is mapped using synchrotron-radiation-based infrared nanospectroscopy with a spatial resolution of 25 nanometres, which enabled particle regions that differ in reactivity to be distinguished. Lastly, these observations demonstrate that, compared to the flat regions on top of the particles, the peripheries of the particles-which contain metal atoms with low coordination numbers-are more active in catalysing oxidation and reduction of chemically active groups in surface-anchored N-heterocyclic carbene molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗