The Feasibility of Tropospheric and Total Ozone Determination Using a Fabry-perot Interferometer as a Satellite-based Nadir-viewing Atmospheric Sensor

Monitoring of the global distribution of tropospheric ozone (O3) is desirable for enhanced scientific understanding as well as to potentially lessen the ill-health impacts associated with exposure to elevated concentrations in the lower atmosphere. Such a capability can be achieved using a satellite-based device making high spectral resolution measurements with high signal-to-noise ratios; this would enable observation in the pressure-broadened wings of strong O3 lines while minimizing the impact of undesirable signal contributions associated with, for example, the terrestrial surface, interfering species, and clouds. The Fabry-Perot Interferometer (FPI) provides high spectral resolution and high throughput capabilities that are essential for this measurement task. Through proper selection of channel spectral regions, the FPI optimized for tropospheric O3 measurements can simultaneously observe a stratospheric component and thus the total O3 column abundance. Decreasing stratospheric O3 concentrations may lead to an increase in biologically harmful solar ultraviolet radiation reaching the earth's surface, which is detrimental to health. In this research, a conceptual instrument design to achieve the desired measurement has been formulated. This involves a double-etalon fixed-gap series configuration FPI along with an ultra-narrow bandpass filter to achieve single-order operation with an overall spectral resolution of approximately .068 cm(exp -1). A spectral region of about 1 cm(exp -1) wide centered at 1054.73 cm(exp -1) within the strong 9.6 micron ozone infrared band is sampled with 24 spectral channels. Other design characteristics include operation from a nadir-viewing satellite configuration utilizing a 9 inch (diameter) telescope and achieving horizontal spatial resolution with a 50 km nadir footprint. A retrieval technique has been implemented and is demonstrated for a tropical atmosphere possessing enhanced tropospheric ozone amounts. An error analysis assessing the impact on retrieved O3 amounts of the most significant uncertainties associated with this particular measurement has been performed for several different types of atmospheres. Results show the proposed instrumentation to enable a good measurement of absolute ozone amounts and an even better determination of relative changes, with a range of accuracy to within 7.55 to 20.6 percent for integrated tropospheric amounts (and 1.99 to 4.02 percent for total O3 column abundance) and a corresponding range in precision to within 7.73 to 10.4 percent (and 3.30 to 3.95 percent for total O3 column abundance), for the atmospheric conditions considered.

Larar, Allen Maurice↗

OSIRIS-REx Touch-and-Go (TAG) Mission Design for Asteroid Sample Collection

The Origins Spectral Interpretation Resource Identification Security Regolith Explorer (OSIRIS-REx) mission is a NASA New Frontiers mission launching in September 2016 to rendezvous with the near-Earth asteroid Bennu in October 2018. After several months of proximity operations to characterize the asteroid, OSIRIS-REx flies a Touch-And-Go (TAG) trajectory to the asteroid's surface to collect at least 60 g of pristine regolith sample for Earth return. This paper provides mission and flight system overviews, with more details on the TAG mission design and key events that occur to safely and successfully collect the sample. An overview of the navigation performed relative to a chosen sample site, along with the maneuvers to reach the desired site is described. Safety monitoring during descent is performed with onboard sensors providing an option to abort, troubleshoot, and try again if necessary. Sample collection occurs using a collection device at the end of an articulating robotic arm during a brief five second contact period, while a constant force spring mechanism in the arm assists to rebound the spacecraft away from the surface. Finally, the sample is measured quantitatively utilizing the law of conservation of angular momentum, along with qualitative data from imagery of the sampling device. Upon sample mass verification, the arm places the sample into the Stardust-heritage Sample Return Capsule (SRC) for return to Earth in September 2023.

OSIRIS-REX TOUCH-AND-GO (TAG) MISSION DESIGN FOR A↗

Development of partitioning as an aid to spectral signature extension

Lists of spectrally similar LACIE sample segments may be constructed with the use of three basic information types: static, seasonal, and pass-specific variables. All are related directly or indirectly to spectral signature behavior and can be used to define spatial domains over which crop-specific signatures should be extendable. Topics covered include: (1) static spectral stratification; (2) evaluation of static partitions relative to variance control objectives; (3) evaluation of the relative importance of static versus seasonal and pass-specific partitioning variables in spectral variability; and (4) a current perspective on partitioning.

Thomas, R. W.↗

Mercury: Mid-infrared (7.3 - 13.5 microns) spectroscopic observations showing features characteristic of plagioclase

Mid-infrared spectroscopic observations of the surface of Mercury are reported for the wavelength range 7.3 to 13.5 microns. The observed spectral radiance emanated from equatorial and low latitude regions between 110-130 deg Mercurian longitude. The area is primarily an intercrater plain. The spectra show distinct and recognizable features, the principal Christiansen emission peak being the most prominent. The Christiansen feature strongly suggests the presence of plagioclase (Ca,Na)(Al,Si)AlSi2O8, (in particular labradorite: Ab(50) - Ab(30)). In addition we have studied the effects of thermal gradients to gain insight into the effects of thermal conditions on the spectral radiance of rock samples. This simulates the thermophysical effects as the rotating surface of Mercury is alternately heated and cooled. The spectral features of the samples are retained; however, the relative and absolute amplitudes vary as illustrated by laboratory reflectance and emittance spectra from quartzite.

Kozlowski, R. W. H.↗

Intrinsic Dimensionality as a Metric for the Impact of Mission Design Parameters

High-resolution space-based spectral imaging of the Earth's surface delivers critical information for monitoring changes in the Earth system as well as resource management and utilization. Orbiting spectrometers are built according to multiple design parameters, including ground sampling distance (GSD), spectral resolution, temporal resolution, and signal-to-noise ratio. Different applications drive divergent instrument designs, so optimization for wide-reaching missions is complex. The Surface Biology and Geology component of NASA's Earth System Observatory addresses science questions and meets applications needs across diverse fields, including terrestrial and aquatic ecosystems, natural disasters, and the cryosphere. The algorithms required to generate the geophysical variables from the observed spectral imagery each have their own inherent dependencies and sensitivities, and weighting these objectively is challenging. Here, we introduce intrinsic dimensionality (ID), a measure of information content, as an applications-agnostic, data-driven metric to quantify performance sensitivity to various design parameters. ID is computed through the analysis of the eigenvalues of the image covariance matrix, and can be thought of as the number of significant principal components. This metric is extremely powerful for quantifying the information content in high-dimensional data, such as spectrally resolved radiances and their changes over space and time. We find that the ID decreases for coarser GSD, decreased spectral resolution and range, less frequent acquisitions, and lower signal-to-noise levels. This decrease in information content has implications for all derived products. ID is simple to compute, providing a single quantitative standard to evaluate combinations of design parameters, irrespective of higher-level algorithms, products, applications, or disciplines.

Intrinsic dimensionality↗

A multiwavelength digital holographic microscope architecture for enhancing life detection

Spectral properties of living organism can provide a discriminating method for characterization. However, digital holographic microscopy (DHM), a high-resolution, volumetric imaging technique that is well-suited for examining microbial species is typically monochromatic. Thus, the spectral properties of bacteria are not probed with DHM save only for the wavelength of operation. Here we describe a new DHM instrument which enhances the method via the simultaneous recording of wavelength multiplexed holograms of the sample. This coarse spectral encoding is akin to labeling with RGB values, thereby producing colorized images of the species which enables a new dimension of characterization. This new instrument is derived from a previous architecture which has already demonstrated superior opto/mechanical stability. Herein, this novel instrument is described, and the results of experimental measurements taken with this new instrument are shown.

Bedrossian, Manuel↗

Ramdb: The NASA Raman Spectral Database (version 1.00).

Given that, in most instances, minimal sample preparation is required and due to its contactless instrument design, Raman spectroscopy is one of the most versatile vibrational spectroscopic techniques for the chemical analysis of environmental and biological specimens. The diversity of applications of Raman spectroscopy ranges anywhere from art [1] to planetary science missions [2]. The advancement in the use of Raman spectroscopy in Solar System missions, notably in post-mission sample return analysis, requires a spectral library holding the broad range of specimens that could be found in Solar System sources. For this purpose, we have initiated the development of a Raman spectral database (Ramdb) at NASA Ames Research Center. Currently, the database includes experimental and theoretical Raman spectra of PAHs [3, 4], as well as laboratory Raman spectra of amino acids, carbon allotropes, minerals, and analogs relevance to Earth Sciences [5], Exobiology [6], Planetary [7], and Astrochemistry [8] to name just a few examples. Ramdb can be found on the web at www.astrochemistry.org/ramdb, where raw and processed Raman spectra can be downloaded in CSV format. The laboratory Raman spectra are measured using a laser Raman spectrometer (JASCO NRS-5500-532QRI). The Raman instrument is equipped with three excitation lasers, with wavelengths of 405, 532, and 785 nm. A clean silicon substrate is used as the internal standard for wavenumber calibration. Powdered samples were prepared (microscopic >10 um, grounded microscopic < 10 um) on glass slides. Some raw data exhibited a background signal arising as a combination of laser-induced fluorescence from the sample. To correct this background, we developed a Python pipeline that uses open-source Python libraries. Ramdb provides both raw and processed (using Python pipeline) data, which includes tabulated Raman shift transitions and other measurement details. The theoretical Raman band positions of PAHs (pyrene monomers and tetramer clusters) were computed using density functional theory (DFT) with the help of the Gaussian 16 suite of programs [9]. In the near future, Ramdb will serve as a repository of Raman spectral data from Laboratory Astrophysics and Planetary Science experiments involving the irradiation of organic compounds under simulated space and planetary conditions. In addition, online and offline tools will be developed for utilising the database for comparison to the user’s sample.

N Punnakayathil↗

Simultaneous Retrieval of Selected Optical Water Quality Indicators From Landsat-8, Sentinel-2, and Sentinel-3

Constructing multi-source satellite-derived water quality (WQ) products in inland and nearshore coastal waters from the past, present, and future missions is a long-standing challenge. Despite inherent differences in sensors’ spectral capability, spatial sampling, and radiometric performance, research efforts focused on formulating, implementing, and validating universal WQ algorithms continue to evolve. This research extends a recently developed machine-learning (ML) model, i.e., Mixture Density Networks (MDNs) (Pahlevan et al., 2020; Smith et al., 2021), to the inverse problem of simultaneously retrieving WQ indicators, including chlorophyll-a (Chla), Total Suspended Solids (TSS), and the absorption by Colored Dissolved Organic Matter at 440 nm (a cdom (440)), across a wide array of aquatic ecosystems. We use a database of in situ measurements to train and optimize MDN models developed for the relevant spectral measurements (400–800 nm) of the Operational Land Imager (OLI), MultiSpectral Instrument (MSI), and Ocean and Land Color Instrument (OLCI) aboard the Landsat-8, Sentinel-2, and Sentinel-3 missions, respectively. Our two performance assessment approaches, namely hold-out and leave-one-out, suggest significant, albeit varying degrees of improvements with respect to second-best algorithms, depending on the sensor and WQ indicator (e.g., 68%, 75%, 117% improvements based on the hold-out method for Chla, TSS, and a cdom (440), respectively from MSI-like spectra). Using these two assessment methods, we provide theoretical upper and lower bounds on model performance when evaluating similar and/or out-of-sample datasets. To evaluate multi-mission product consistency across broad spatial scales, map products are demonstrated for three near-concurrent OLI, MSI, and OLCI acquisitions. Overall, estimated TSS and a cdom (440) from these three missions are consistent within the uncertainty of the model, but Chla maps from MSI and OLCI achieve greater accuracy than those from OLI. By applying two different atmospheric correction processors to OLI and MSI images, we also conduct matchup analyses to quantify the sensitivity of the MDN model and best-practice algorithms to uncertainties in reflectance products. Our model is less or equally sensitive to these uncertainties compared to other algorithms. Recognizing their uncertainties, MDN models can be applied as a global algorithm to enable harmonized retrievals of Chla, TSS, and a cdom (440) in various aquatic ecosystems from multi-source satellite imagery. Local and/or regional ML models tuned with an apt data distribution (e.g., a subset of our dataset) should nevertheless be expected to outperform our global model.

Machine learning↗

Spectral and correlation analysis with applications to middle-atmosphere radars

The correlation and spectral analysis methods for uniformly sampled stationary random signals, estimation of their spectral moments, and problems arising due to nonstationary are reviewed. Some of these methods are already in routine use in atmospheric radar experiments. Other methods based on the maximum entropy principle and time series models have been used in analyzing data, but are just beginning to receive attention in the analysis of radar signals. These methods are also briefly discussed.

Rastogi, Prabhat K.↗

Spectroscopic and Geochemical Analyses of Ferrihydrite from Hydrothermal Springs in Iceland and Applications to Mars

Ferrihydrite samples were collected from a thermal spring and a cold stream in the Landmannalaugar region of Iceland. Chemical and spectroscopic analyses have been performed on the air-dried and fine-grained fractions of these samples. The ferrihydrite from the cold stream is a pure sample, containing small amounts of Ca, P and Si, which do not form minerals detectable with X-ray diffraction (XRD) or reflectance and transmittance spectroscopy. The ferrihydrite from the thermal pool is a less pure sample, containing larger amounts of amorphous Si and P. The XRD and spectral features for this sample are also consistent with a less crystalline structure. Some of the Si is incorporated in the structure of the ferrihydrite. The Ca, P and possibly some of the Si may be biogenic. The spectral character of these Icelandic ferrihydrites is compared with those of synthetic ferrihydrites and other iron oxide/oxyhydroxide minerals. Ferrihydrite is characterized by a broad Fe3+ excitation band near 0.92 microns (approx. 10900/cm) and a strong Fe-O absorption feature near 475/cm (approx. 21 microns) in transmittance spectra. Multiple bands due to H2O and OH are also present for ferrihydrite. Natural ferrihydrites frequently exhibit a band near 950-1050/cm (approx. 10 microns) that is typically not observed for synthetic ferrihydrites and may be due to some Si in the structure. An additional pair of spectral bands near 1400 and 1500/cm (approx. 7 microns) are characteristic of pure ferrihydrites from natural and synthetic sources. Hydrothermal springs may have been present at one time on Mars in association with volcanic activity. Ferrihydrite formation in such an environment may have contributed to the ferric oxide-rich surface material on Mars.

Bishop, Janice↗

Thermal infrared spectral character of Hawaiian basaltic glasses

Thermal IR reflectance spectra of exposed surfaces of Hawaiian basalt samples from Mauna Loa and Kilauea show systematic changes with age. Spectra of fresh glass collected from active lava flows showed evidence of a strong degree of disorder. After a few weeks of exposure to the laboratory environment, spectra of the top surfaces of these samples began to exhibit spectral features suggestive of ordering into silicate chainlike ansd sheetlike units. With progressive aging, features of apparent sheetlike structures became the preferred mode.

Crisp, Joy↗

The dependence of the soft X ray spectral slope with radio property, luminosity, and redshift, for a large sample of AGN from the Einstein IPC data base

The dependence of the soft X-ray spectral slope on radio, optical and X-ray properties, and on redshift are reported for a large sample of Active Galactic Nuclei (AGN). The sample includes 317 optically and radio-selected AGN from a preliminary version of the Einstein Imaging Proportional Counter (IPC) quasar and AGN data base. The main results are: the difference in X-ray slope between radio-loud and radio-quiet AGN were confirmed for an independent and much larger sample of sources; a difference in X-ray slope between flat and steep radio spectrum AGN is observed only in high luminosity sub-sample; in flat radio spectrum AGNs there is an indication for a dependence of the X-ray spectral index on X-ray luminosity redshift and alpha sub 0x.

Brunner, H.↗

Spectrometer integrated with a facsimile camera

This invention integrates a spectrometer capability with the basic imagery function of facsimile cameras without significantly increasing mechanical or optical complexity, or interfering with the imaging function. The invention consists of a group of photodetectors arranged in a linear array in the focal plane of the facsimile camera with a separate narrow band interference filter centered over each photodetector. The interference filter photodetector array is on a line in the focal plane of the facsimile camera along the direction of image motion due to the rotation of the facsimile camera's vertical mirror. As the image of the picture element of interest travels down the interference filter photodetector array, the photodetector outputs are synchronously selected and sampled to provide spectral information on the single picture element.

Burcher, E. E.↗

Measurement of sputtered efflux from 5-, 8-, and 30-cm diameter mercury ion thrusters

A technique has been developed which uses spectral transmittance of samples exposed to thruster efflux to determine and characterize the effect of the efflux on spacecraft surfaces and optical devices. An investigation of facility backsputter revealed that efflux samples must be protected (e.g., by small shield boxes) from materials from tank walls and targets. The composition of the sputter efflux deposited on the samples was mostly molybdenum with trace amounts of tantalum, iron and/or mercury. The efflux from a 5-cm diameter thruster was deposited on samples located in the plane of the accelerator grid; the 8-cm diameter thruster efflux results showed that the location of ion beam sputtering and efflux deposition equilibrium occurred at 57 deg with respect to the thruster axis; and the 30-cm diameter thruster had an ion beam erosion-efflux deposition equilibrium at 45 deg.

Weigand, A. J.↗