Search NASA⌕ Search

SEARCH · Search NASA

Results for “standard plasma sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

136 records · Page 8

Rapid retrieval of first-order spatiotemporal distortions for ultrashort laser pulses

High-intensity, ultrashort laser sources are a foundational pillar for High-Energy-Density (HED) physics, and as the repetition-rates of these systems increase, diagnostics must be developed to match their data collection speed. Characterization of any spatiotemporal distortions in the laser pulse is necessary in order to standardize results across facilities. Here, we have previously developed a laser diagnostic called Spatially and Temporally Resolved Intensity and Phase Evaluation Device: Full Information from a Single Hologram, or STRIPED FISH, to measure the full spatiotemporal laser electric field on a single shot. In order to provide rapid feedback, we here adapt the STRIPED FISH retrieval algorithm, which typically has computation times of up to 30 minutes due to the high spatial resolution of the device and its retrieval of the complete four-dimensional pulse field, to distill the key electric field quantities into a handful of scalars for rapid assessment of the pulse's first order distortions. Here, our new, rapid non-iterative retrieval algorithm is validated with simulated and experimental data, and it provides, within seconds, the same first-order information as given by the full analysis. This algorithm is suitable for on-shot assessment of spatiotemporal distortions and can be adapted to assess high repetition-rate laser quality in HED experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fireball antinucleosynthesis

The tentative identification of approximately ten relativistic antihelium ( He ¯ ) cosmic-ray events at AMS-02 would, if confirmed, challenge our understanding of the astrophysical synthesis of heavy antinuclei. We propose a novel scenario for the enhanced production of such antinuclei that is triggered by isolated, catastrophic injections of large quantities of energetic Standard Model (SM) antiquarks in our galaxy by physics beyond the Standard Model (BSM). We demonstrate that SM antinucleosynthetic processes that occur in the resulting rapidly expanding, thermalized fireballs of SM plasma can, for a reasonable range of parameters, produce the reported tentative ∼ 2 : 1 ratio of He ¯ 3 to He ¯ 4 events at AMS-02, as well as their relativistic boosts. Moreover, we show that this can be achieved without violating antideuterium or antiproton flux constraints for the appropriate antihelium fluxes. A plausible BSM paradigm for the catastrophic injections is the collision of macroscopic composite dark-matter objects carrying large net antibaryon number. Such a scenario would require these objects to be cosmologically stable, but to destabilize upon collision, promptly releasing a fraction of their mass energy into SM antiparticles within a tiny volume. We show that, in principle, the injection rate needed to attain the necessary antihelium fluxes and the energetic conditions required to seed the fireballs appear possible to obtain in such a paradigm. We leave open the question of constructing a BSM particle physics model to realize this, but we suggest two concrete scenarios as promising targets for further investigation. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗

Evaluation of RMI Ejecta Sourcing from Reconstructed Interfaces in 2D FLAG Flyer-Plate Simulations

This study investigates the performance of RMI ejecta sourcing from a reconstructed interface in two-dimensional FLAG ejecta flyer-plate simulations. Enabling the RMI ejecta model to operate on reconstructed interfaces has been a longstanding challenge in FLAG, limiting its applicability to experiments in which interface reconstruction is not required. Addressing this limitation is therefore an important step toward expanding the model’s predictive capability. The first phase of this effort focused on identifying a flyer-plate/target configuration that produces large ejecta clouds from two distinct shocks using the standard RMI ejecta model. A series of simulations examined the effects of flyer composition, layer thickness, and mesh resolution on shock structure and ejecta formation. VISAR traces were used to evaluate shock timing and identify configurations that produced a clear double-shock response. A copper middle-layer flyer with a doubled tin layer yielded the most favorable shock characteristics and was selected as the baseline configuration. After confirming this configuration performed as expected when running a reference FLAG version, it became the basis for three simulations: (1) a standard two-dimensional ejecta flyer-plate calculation using a reference FLAG version, (2) the same calculation with the reconstructed interface option enabled, and (3) a calculation employing ALE strategies to force the ejecta model to operate on the reconstructed interface. While the baseline simulation produced the expected ejecta response, the reconstructed interface approach did not result in measurable ejecta, indicating that this capability remains under development. These results highlight both the progress made and the remaining challenges in extending the RMI ejecta model to reconstructed interfaces.

36 MATERIALS SCIENCE↗

3D quantum ghost imaging microscope

Quantum ghost imaging uses quantum-entangled photons to generate a two-dimensional image with only a bucket detector at the sample. Here we expand on this approach to generate a three-dimensional image without scanning. A quantum-entangled light source directly links information between a pair of 2D sensors, one of which captures a standard image from one perspective and a second sensor which captures a ghost image from a perpendicular perspective. By correlating the spatial information from the two detectors for each photon pair, we obtain three dimensions of spatial information (x, y, and z) for each scattered photon. We demonstrate that this system can study microscopic environments by imaging scattering from metallic nanoparticle clusters. This approach has the potential to greatly reduce the flux of light required to obtain a 3D image of a biological sample and thereby extend the number of images that can be obtained before photodamaging the sample.

Eshun, Audrey [Lawrence Livermore National Laborat↗

Mid-Infrared Reflectance Imaging of Thermal-Barrier Coatings

An apparatus for mid-infrared reflectance imaging has been developed as means of inspecting for subsurface damage in thermal-barrier coatings (TBCs). The apparatus is designed, more specifically, for imaging the progression of buried delamination cracks in plasma-sprayed yttria-stabilized zirconia coatings on turbine-engine components. Progression of TBC delamination occurs by the formation of buried cracks that grow and then link together to produce eventual TBC spallation. The mid-infrared reflectance imaging system described here makes it possible to see delamination progression that is invisible to the unaided eye, and therefore give sufficiently advanced warning before delamination progression adversely affects engine performance and safety. The apparatus (see figure) includes a commercial mid-infrared camera that contains a liquid-nitrogen-cooled focal plane indium antimonide photodetector array, and imaging is restricted by a narrow bandpass centered at wavelength of 4 microns. This narrow wavelength range centered at 4 microns was chosen because (1) it enables avoidance of interfering absorptions by atmospheric OH and CO2 at 3 and 4.25 microns, respectively; and (2) the coating material exhibits maximum transparency in this wavelength range. Delamination contrast is produced in the midinfrared reflectance images because the introduction of cracks into the TBC creates an internal TBC/air-gap interface with a high diffuse reflectivity of 0.81, resulting in substantially higher reflectance of mid-infrared radiation in regions that contain buried delamination cracks. The camera is positioned a short distance (.12 cm) from the specimen. The mid-infrared illumination is generated by a 50-watt silicon carbide source positioned to the side of the mid-infrared camera, and the illumination is collimated and reflected onto the specimen by a 6.35-cm-diameter off-axis paraboloidal mirror. Because the collected images are of a steady-state reflected intensity (in contrast to the transient thermal response observed in infrared thermography), collection times can be lengthened to whatever extent needed to achieve desired signal-to-noise ratios. Each image is digitized, and the resulting data are processed in several steps to obtain a true mid-infrared reflectance image. The raw image includes thermal radiation emitted by the specimen in addition to the desired reflected radiation. The thermal-radiation contribution is eliminated by subtracting the image obtained with the illumination off from the image obtained with the illumination on. A flat-field correction is then made to remove the effects of non-uniformities in the illumination level and pixel-to-pixel variations in sensitivity. This correction is performed by normalizing to an image of a standard object that has a known reflectance at a wavelength of 4 microns. After correction, each pixel value is proportional to the reflectance (at a wavelength of 4-microns) at the corresponding location on the specimen. Mid-infrared reflectance imaging of specimens that were thermally cyc led for different numbers of cycles was performed and demonstrated t hat mid-infrared reflectance imaging was able to monitor the gradual delamination progression that occurs with continued thermal cycling . Reproducible values were obtained for the reflectance associated w ith an attached and fully delaminated TBC, so that intermediate refle ctance values could be interpreted to successfully predict the numbe r of thermal cycles to failure.

Edlridge, Jeffrey I.↗

MOOSE-based Tritium Migration Analysis Program, Version 8 (TMAP8) for advanced open-source tritium transport and fuel cycle modeling

Tritium management is critical for the safety, sustainability, and economics of fusion energy systems, and advanced and reliable modeling tools help accelerate the development of tritium technologies. This paper presents the Tritium Migration Analysis Program, Version 8 (TMAP8), an open-source, MOOSE-based application developed to provide state-of-the-art tritium transport and fuel cycle modeling capabilities. TMAP8 aims to expand the capabilities of previous versions (i.e., TMAP4 and TMAP7) by leveraging modern computational techniques, ensuring high software quality assurance standards (key to building trust), and enabling multispecies, multiscale, and multiphysics simulations for integrated tritium transport modeling in complex geometries. This paper outlines TMAP8’s scope and rigorous development practices, emphasizing its transparency, accessibility, modularity, and reliability. We present the current suite of verification and validation cases based on those from TMAP4, demonstrating TMAP8’s accuracy and reliability against analytical solutions and experimental data. Additionally, the paper showcases TMAP8’s integrated fuel cycle modeling capabilities, highlighting its applicability at various scales and levels. The TMAP8 code and documentation are openly available, promoting collaborative development and widespread adoption within the fusion community. Future work will soon expand TMAP8’s verification and validation suite to include those from TMAP7 and other recent experimental studies for validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Composition, Activity, and Stability of IrO x Oxygen Evolution Reaction Electrocatalysts

The oxygen evolution reaction (OER) is integral to several electrochemical energy conversion and storage technologies, including carbon dioxide reduction to value added fuels, nitrogen reduction to ammonia, reversible fuel cells, rechargeable metal−air batteries, and water electrolysis to produce hydrogen. Iridium oxide (IrO x ) is widely recognized as the benchmark OER catalyst for acidic environments. Despite widespread use of IrO x catalysts, most notably in proton-exchange membrane water electrolyzers (PEMWEs), a comprehensive understanding of the physicochemical properties of commercial catalysts and the impact of these properties on both the activity and stability of these catalysts is lacking. Here, we study commercial IrO x catalysts with different physicochemical properties, three nominally considered amorphous and three rutile, to elucidate how structural and compositional variations affect OER activity and stability. Utilizing standardized aqueous electrochemical protocols, time-resolved dissolution quantification using inductively-coupled plasma mass spectrometry, and physicochemical characterization, including multiple synchrotron X-ray techniques, we systematically correlate catalyst properties with OER performance and degradation behavior aided by principal component analysis (PCA). Our results demonstrate the general trend of amorphous IrO x having higher intrinsic activity but limited stability and crystalline rutile IrO 2 having lower activity but enhanced stability against dissolution. The trends within the amorphous and rutile catalyst groups correlate with inherent material properties, including phase composition and structure, crystallinity, particle size, surface area, and surface structure/chemistry. Notably, we identify a rutile catalyst with the largest crystallite/ domain sizes, moderate surface area, a small fraction of hydrous phase, and a favorable pore structure (trimodal distributions of pore sizes ranging from 2−5 nm) that exhibits the best balance between activity and stability among the six catalysts studied here. These findings illustrate a fundamental structure-governed trade-off between activity and stability and highlight the critical role of surface chemistry modification and structure engineering in IrO x catalyst optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-Sourced Collaboration for the Production and Refining of Rare Elements and Critical Metals (Final Technical Report)

The project objective was to develop a feasible and cost-effective method for recovering rare earth elements (REEs) and critical materials (CMs) from coal and coal byproducts, resulting in high-purity individually separated REEs and CMs. The targeted REEs included Y, Pr, Nd, Gd, Dy, and Sm, with a purity of over 99.5%, while the CMs included Co, Mn, Ga, Sr, Li, Ni, Zn, and Ge, with a purity of over 90%. The project aimed to design a prototype facility capable of producing 1-3 tonnes/day of high-purity REO mixes. The work was divided into four designated circuits: 1) REE extraction and concentration, 2) REE separation and purification, 3) RE metal production, and 4) CM production. To achieve these goals, the project involved 11 tasks, including technology reviews, research, process flow diagram development, mass balance estimation, and preliminary technical-economic analysis. The project team included researchers from the University of Kentucky, University of Alabama and Virginia Tech as well as process specialists from Argonne National Laboratory. MP Materials provided technical support regarding rare earth markets and processing while Alliance Coal performed resource assessment. The project included a market analysis for Nd/Pr, Tb, Dy, Gd, Y, Co, Mn, Li, Sr, Ga, Ni, Zn, and Ge. These analyses provided insights into the supply and demand trends as well as historic and future projections of market price relative to purity requirements for these elements. Two coal resources were selected for the project: the West Kentucky No. 13 (Baker) Seam and an undisclosed lignite resource in the Illinois coal basin. The estimated quantities of REEs in these resources were calculated based on production samples and drilling data. It was estimated that there is adequate supply for an operation producing one metric ton daily of higher purity mixed rare earth oxides (MREO) for approximately 20 years at a site located in western Kentucky. In Circuit 1, project data was obtained from a pilot heap leach and REE concentration facility. It was concluded that the existing circuit, which generated a MREO concentrate, two types of CM mixed products, and Li- and Sr-containing waters, would be suitable feed for circuits 2-4. Data from the first-of-its-kind coal coarse refuse heap leach pilot pad played a crucial role in estimating reliable elemental concentrations of the pregnant leaching solution (PLS). The average total REE concentration in the PLS was found to be 28.6 ppm. In Circuit 2, several concepts were explored including a novel process referred to as solvent-assisted chromatography (SAC). This concept involved a novel columnar reactor that incorporated multiple mixer/settlers, thereby enabling the operation of counter-flowing aqueous and organic phases. Unfortunately, due to project time constraints, a complete fundamental modeling analysis could not be completed to fully evaluate the technology. Molten salt electrowinning was considered as an alternative for circuit 3 following circuit 2 purification circuit utilizing the novel SAC process. A mass and energy balance of Nd reduction to metal in a fluoride containing molten salt electrolyte was conducted. Comparisons were made with the current state of Asian molten salt electrorefining, and potential improvements in siphoning rare earth metals (REM) from the reactor were presented. A cost estimate was performed for the production of 1 tonne per day, which yielded a total of $2.29 million for the nine electrowinning (EW) cells required. The selected option for circuits 2 and 3 was a plasma distillation process, which initially separates rare earth elements (REEs) from other elements. This is followed by selective electrowinning in various ionic liquids. The selection was made on the basis of thermodynamic modeling and experimental data previously published by a project partner. The combination offers an innovative approach to integrated refining and RE metal production. For Circuit 4, an extensive literature review was conducted for the processing of the CMs. The ultimate decision was to utilize a combined plasma and ionic liquid process as well to produce individual high-purity concentrates of Zn, Ni, Co, Mn, and Mg. A separate flowsheet for Li and Sr was recommended, which would yield carbonates of these elements. Due to the lack of suitable experimental data at this time, a process recommendation could not be provided but several methods have been proposed for consideration. Lastly, a techno-economic analysis (TEA) was conducted to assess the effectiveness of the proposed process for further investigation. The TEA results revealed a capital expense (CapEx) of $737 million and an annual operational expense (OpEx) of $220 million. Due to the selected elements, the hypothetical heap leach pad can produce 1 metric tonne per day of REO equivalent, but a conscious decision was made to only treat targeted REEs, resulting in the production of 0.4 metric tonne of REM. An estimated annual revenue of $90.87 million was projected based on standard market pricing information provided by the funding agency. During the TEA, ten different modules were evaluated for costing purposes. The precipitation circuit was identified as the largest single operational expense, followed by the Mg/Mn process due to the amount of treated metal. In terms of capital expenditures, the heap leach process incurred the highest cost, followed by the Mg/Mn process. The scalability of the plasma process is a crucial consideration since the reactors cannot be scaled beyond the largest demonstrated size due to their reliance on surface area of the slag and vapor phase. The purity estimate for the REEs are generally 98%±2% to produce a metal. The purity level being lower than the project objective was due to the lack of specific experimental data needed to tighten the tolerance of the estimates. Based on literature and previous experience, the CMs are estimated as follows; Ga (95%+, metal), Sr (95%+, carbonate), Li (95%+, carbonate), Ni (98%±2%, metal), Zn (95%+, metal sponge), Ge (95%+, metal), Co (98%±2%, metal), and Mn (98%±2%, metal).

01 COAL, LIGNITE, AND PEAT↗