Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage futures study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Modular, Crushed-Rock Thermal Energy Storage Pilot Design (Final Report)

The goal of this project was to design a next-step pilot to advance near-term energy storage integrated with a fossil plant to provide a facility capable of being viable and effective in a market with growing penetration of variable renewable energy (VRE). Thermal energy storage (TES) represents an ideal technology for this purpose. The completed effort included a feasibility study to prepare for the Phase II pre-front end engineering design (pre-FEED) for implementing a crushed-rock TES system integrated with a natural gas combined cycle (NGCC) plant. The crushed rock storage technology, which is being developed by Brenmiller Energy, is a modular TES system termed bGen™, which can accommodate both thermal and electrical inputs and output steam, hot water, or hot air. For this application, the estimated efficiency is 80% thermal to thermal. For the feasibility study, the Brenmiller technology was designed to operate on a slipstream from NYPA’s Eugene W. Zeltmann Power Project (Zeltmann) NGCC plant in Astoria, New York. The projected size of the system will be up to 4 MWe with at least 4 hours of storage duration, or 16 MWh-e total. The study also included a techno-economic evaluation of a 200 MWh commercial-scale demonstration. Prior to this project, EPRI had reviewed Brenmiller’s technology, which is being built to demonstrate bGen™ at 1.7 MWe on a solar plant (Rotem) and has been designed for an NGCC facility in Italy, assessing it at technology readiness level (TRL) 5. Brenmiller is also conducting a separate 1-MWth pilot with NYPA that pairs a bGen™ module with a microturbine for a combined-heat-and-power (CHP) application to improve efficiency and provide flexibility. The next-step pilot being designed as part of this project would represent a 5-fold increase in scale, versus Rotem, and would show the technology’s ability to provide effective and economical energy storage, bringing the technology to TRL 6. This pilot would represent the next-to-last demonstration scale before the technology could be commercial ready at GWh-e scales in the 2030 timeframe. The main objective of the work completed by the Electric Power Research Institute, Inc. (EPRI), Brenmiller Energy (Brenmiller), New York Power Authority (NYPA), and United E&C (formerly AECOM) was to perform a Phase I feasibility study on the integration of a crushed-rock thermal energy storage (TES) with a fossil plant. Under this project, the EPRI-led team successfully completed a feasibility study to prepare for the potential future Phase II pre-front end engineering design (pre-FEED) to implement a crushed-rock TES system integrated with a natural gas combined cycle (NGCC) plant. Specific deliverables under this project included the Technology Maturation Plan, Conceptual Study, Techno-Economic Assessment, Technology Gap Assessment, Project Plan for Phase II (submitted as Phase II Renewal Application), Commercialization Plan, and the Final Report (this document). This Final Report includes a compilation of the various summary reports that were prepared during the 12-month schedule of the Phase I project execution under award DE-FE0032017.

03 NATURAL GAS↗

Field expedient stool collection methods for gut microbiome analysis in deployed military environments

ABSTRACT Field expedient devices and protocols for the collection, storage, and shipment of stool samples in deployed settings are needed for the advancement of microbiome research in military health. Relevant assessments include the evaluation of microbiome signatures associated with susceptibility to travelers’ diarrhea and recovery of gut function following infection. However, inherent biases in microbial measurements due to preservatives and sampling methods are unclear and should be assessed for an accurate evaluation of the microbiome. We performed shotgun metagenomic sequencing and compared the microbiome composition in paired fecal samples collected using Flinters Technology Associates (FTA) cards and OMNIgene (OG) Gut tubes, prior to and during international travel, from 49 adult participants, 39 of whom remained asymptomatic and 10 experienced travelers’ diarrhea. Higher concentrations of nucleic acid and sequencing libraries were observed in OG samples. A majority of genera (82.9%) were detected with both methods, and detections of genera limited to one collection method were not highly prevalent across samples and were present in extremely low relative abundances (<0.01%). Differences in beta diversity were largely explained by inter-individuality of microbiome composition, followed by the effect of collection method and timepoint-disease states. Differential abundance analysis indicated that Corynebacterium and Blautia were consistently higher in abundance across all groups with FTA and OG collection, respectively. The observed differences in microbiome composition between methods suggest the need for consistent and standardized protocols within a study. Overall, the data presented here could help guide the future design of fecal microbiome study protocols in field and military deployment settings. IMPORTANCE The assessment of field-deployable methods for fecal sample collection and storage is required to reliably capture samples collected in remote and austere locations. This study describes a comparative metagenomics analysis between samples collected by two different commercially available methods in a military-deployed setting. The results presented here are foundational for the future design of fecal microbiome study protocols in an operational context.

field study↗

Evaluating Impacts of the Inflation Reduction Act and Bipartisan Infrastructure Law on the U.S. Power System

The Inflation Reduction Act of 2022 (IRA) and the Infrastructure Investment and Jobs Act of 2021, commonly referred to as the 'Bipartisan Infrastructure Law (BIL),' collectively represent the largest commitment of the U.S. Federal Government to invest in the modernization and decarbonization of the U.S. energy system. The Congressional Budget Office (CBO) estimates that total support for the broad range of climate and clean energy programs, tax credits, and other incentives authorized through the two laws will exceed $430 billion from 2022 through 2031 (CRS 2022; CBO 2021, 2022). While the climate and clean energy provisions are numerous and have the potential to impact all aspects of the U.S. energy system from fuel and electricity production to final consumption in industry, transportation, and buildings, the provisions relevant to the electricity sector - in particular the suite of tax credits for clean generation, storage, and carbon dioxide ( CO 2 ) capture and storage - are expected to be some of the most consequential in terms of emissions reduction and clean energy deployment (Larsen et al. 2022; Jenkins, Mayfield, et al. 2022; Mahajan et al. 2022; Zhao et al. 2022). In this report, we detail the methods and results of a study estimating the potential impacts of key provisions of IRA and BIL on the contiguous U.S. power sector from present day through 2030. The analysis employs an advanced power system planning model, the Regional Energy Deployment System (ReEDS), to evaluate how major provisions from both laws impact investment in and operation of utility-scale generation, storage, and transmission, and, in turn, how those changes impact power system costs, emissions, and climate and health damages. While not exhaustive in capturing every provision, the analysis estimates the possible scale of power-sector impacts that could result from the modeled provisions in IRA and BIL. The study is structured around two scenarios to evaluate the potential impacts of both laws on the power sector: 1) No New Policy: A counter-factual scenario that reflects all Federal and state policies enacted as of September 2022, with exception to IRA and BIL, and assumes load growth consistent with the Energy Information Administration's Annual Energy Outlook 2022 (AEO22) Reference case (EIA 2022a); 2) IRA-BIL: A scenario reflecting all Federal and state policies enacted as of September 2022, including key IRA and BIL provisions, most notably the investment and production tax credits for zero-carbon emitting electricity generation and storage (ITC and PTC), the tax credit for CO 2 capture and storage (45Q), and the tax credit for existing nuclear plants (described further in Section 2.3). To account for the impacts of IRA and BIL on electrification, assumes increased load growth consistent with a scaled version of the Medium Electrification scenario from the Electrification Futures Study (Mai et al. 2018). These scenarios are simulated across seven sets of assumptions with varying projected future electricity market conditions, including technology costs and performance, natural gas prices, and the degree of availability, feasibility, and cost of development of renewable resources, electricity transmission, and CO 2 pipeline, injection, and storage infrastructure. In addition, we simulate two sensitivities on the 'policy' treatment in which we vary key assumptions pertaining to the realized value of the clean electricity ITC and PTC: 1) the cost of monetization of tax credits, and 2) the level of bonus crediting realized by project developers. We demonstrate that IRA and BIL have the collective potential to drive substantial growth in clean electricity by 2030, while reducing costs for consumers, mitigating climate change, and decreasing the human health impacts of power sector emissions. However, we also demonstrate that if expected cost improvements of clean technologies are not realized and/or constraints on deployment driven by factors such as supply-chain challenges, regulatory hurdles, and the social acceptability of energy infrastructure development limit the rate of clean energy and associated infrastructure deployment (such as transmission), then the share of clean generation achieved and the associated emissions benefits realized may be substantively reduced.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluating grid stress and reliability in future electricity grids across a range of demand, generation mix, and weather trends

The reliability of power grids in the future will depend on how system planners account for the integration of new technologies, extreme weather events, and uncertainties in demand growth from increased electrification and data centers. This study introduces an open-source, multisectoral, multiscale modeling framework that projects grid stress and reliability trends between 2020 and 2055 in the Western Interconnection of the United States. The framework integrates global to national energy-water-land dynamics with power plant siting and hourly grid operations modeling. We analyze future wholesale electricity price shocks and unserved energy events across eight scenarios spanning a range of population growth and economic change, generation mixes, and weather conditions. Our results show future grids with high percentage of non-renewable generation and strong economic growth are characterized by higher reliability and lower wholesale electricity prices than lower growth scenarios because of larger reliance on dispatchable generators and lower fossil fuel extraction costs. Scenarios with high percentage of renewable resources have lower median but more volatile wholesale electricity prices as well as more frequent and severe unserved energy events compared to scenarios relying more on dispatchable generators. These events occur because higher proportion of solar and wind energy causes net demand curves to deepen during midday (duck curves get progressively severe), exacerbating the challenge of meeting demand during summer evening peaks. This study suggests that robust and co-optimized transmission and energy storage planning could help maintain low wholesale electricity prices and high reliability levels in future electricity grids across uncertainties in generation mixes.

Electric grid reliability↗

Assessment of CO 2 trapping mechanisms in partially depleted oil-bearing sands

The goal of this work is to evaluate various CO 2 sequestration mechanisms occurring in the Morrow B Sandstone in the Farnsworth Unit. A history-matched numerical simulation model was created using extensive geological, petrophysical, and operational data collected from the field. The numerical model is competent to investigate the impact of residual, structural-stratigraphic, solubility, and mineral trapping mechanisms on the fluid transportation dynamics and petrophysical property variations. The model forecasts the field response of 20 years of WAG injections. Afterward, all wells were shut-in, and the reservoir was allowed to evolve for 1000 years to investigate the fate of injected CO 2 . In this paper, we assess the impacts of various trapping mechanisms on oil recovery and CO 2 storage efficacy. By analyzing the results reported from the numerical simulation model, the in-situ fluid composition and mineralogy changes are also investigated. More importantly, we seek to confirm the petrophysical property variations due to the CO 2 injection with observations from laboratory measurements. The experiences gained from this study provide valuable insights regarding physiochemical storage induced by the CO 2 injection activities and serve as a benchmark case for future CO 2 enhanced oil recovery (EOR) projects involving reactive solute transport.

42 ENGINEERING↗

Fine‐root dynamics in deeper soils: a critical but overlooked component of ecosystem responses to climate warming

Climate warming is predicted to strongly affect the functioning of terrestrial ecosystems. The plant root system is a critical component of these ecosystems, with fine roots, in particular, playing a key role in plant water and nutrient uptake and transport. In addition, root litter and exudation represent the dominant plant carbon inputs into soil. Consequently, understanding fine‐root responses to warming is essential for predicting how the growth, resilience, and carbon storage of terrestrial ecosystems will respond to future climate change. Despite the growing literature on fine‐root responses to warming, most studies have focused on topsoil (0–30 cm). However, a significant portion of the fine‐root mass occurs below this depth. For instance, c. 40% of fine‐root mass is found below 30 cm in temperate and tropical ecosystems. Due to the importance of fine roots for plants and belowground carbon cycling, focusing solely on surface soils overlooks the critical need for insights into how roots in deeper soil layers (e.g. below 30 cm) respond to warming. We argue that studying the entire soil profile is necessary to comprehensively understand fine‐root dynamics under climate warming and the implications for soil organic carbon cycling, water, and nutrient uptake.

climate warming↗

Feasibility of Hybrid Electro- and Acousto-Dynamical Systems for Quantum Optical Networks

We present results on an exploratory research program that aims to study the feasibility of novel, sustained, dense, and efficient quantum information generation, storage, retrieval, relay and distribution devices and systems towards future advanced quantum networking architectures. The pathfinder program is anchored on original ideas and device conceptual designs that turn the phononic-sourced challenges into an opportunity towards optimized transduction chains over a broad range of length and energy/temperature scales. The proposal involves conceptual design and feasibility towards integration, commissioning and benchmarking of challenging transduction devices in a scaled quantum network setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Review of Coupled Geochemical–Geomechanical Impacts in Subsurface CO 2 , H 2 , and Air Storage Systems

Increased demand for decarbonization and renewable energy has led to increasing interest in engineered subsurface storage systems for large-scale carbon reduction and energy storage. In these applications, a working fluid (CO 2 , H 2 , air, etc.) is injected into a deep formation for permanent sequestration or seasonal energy storage. The heterogeneous nature of the porous formation and the fluid–rock interactions introduce complexity and uncertainty in the fate of the injected component and host formations in these applications. Interactions between the working gas, native brine, and formation mineralogy must be adequately assessed to evaluate the efficiency, risk, and viability of a particular storage site and operational regime. This study reviews the current state of knowledge about coupled geochemical–geomechanical impacts in geologic carbon sequestration (GCS), underground hydrogen storage (UHS), and compressed air energy storage (CAES) systems involving the injection of CO 2 , H 2 , and air. Specific review topics include (1) existing injection induced geochemical reactions in these systems; (2) the impact of these reactions on the porosity and permeability of host formation; (3) the impact of these reactions on the mechanical properties of host formation; and (4) the investigation of geochemical-geomechanical process in pilot scale GCS. This study helps to facilitate an understanding of the potential geochemical–geomechanical risks involved in different subsurface energy storage systems and highlights future research needs.

08 HYDROGEN↗

NDE to Manage Atmospheric SCC in Canisters for Dry Storage of Spent Fuel: An Assessment

This report documents efforts to assess representative horizontal (Transuclear NUHOMS®) and vertical (Holtec HI-STORM) storage systems for the implementation of non-destructive examination (NDE) methods or techniques to manage atmospheric stress corrosion cracking (SCC) in canisters for dry storage of used nuclear fuel. The assessment is conducted by assessing accessibility and deployment, environmental compatibility, and applicability of NDE methods. A recommendation of this assessment is to focus on bulk ultrasonic and eddy current techniques for direct canister monitoring of atmospheric SCC. This assessment also highlights canister regions that may be most vulnerable to atmospheric SCC to guide the use of bulk ultrasonic and eddy current examinations. An assessment of accessibility also identifies canister regions that are easiest and more difficult to access through the ventilation paths of the concrete shielding modules. A conceivable sampling strategy for canister inspections is to sample only the easiest to access portions of vulnerable regions. There are aspects to performing an NDE inspection of dry canister storage system (DCSS) canisters for atmospheric SCC that have not been addressed in previous performance studies. These aspects provide the basis for recommendations of future efforts to determine the capability and performance of eddy current and bulk ultrasonic examinations for atmospheric SCC in DCSS canisters. Finally, other important areas of investigation are identified including the development of instrumented surveillance specimens to identify when conditions are conducive for atmospheric SCC, characterization of atmospheric SCC morphology, and an assessment of air flow patterns over canister surfaces and their influence on chloride deposition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exploring the Future Energy Value of Long-Duration Energy Storage

Long-duration energy storage is commonly viewed as a key technology for providing flexibility to the grid and broader energy systems over a multidecadal time frame. However, prior work has typically used present-day grid infrastructures to characterize the relationship between the duration and arbitrage value of storage in electricity markets. This study leverages established National Renewable Energy Laboratory grid planning and operations tools, analysis, and data to execute a price-taker model of an energy storage system for several 8760 h price series representative of current and future contiguous United States grid infrastructures with varying shares of variable renewable energy (VRE). We find that the total value of energy storage typically increases with VRE shares, but any increase in the relative value of longer storage durations over time depends on the region and grid mix. Some regions see incremental value increasing notably, up to 20–40 h in 2050, while others do not. The negative effect of lower roundtrip efficiency on value is also found to be scenario-dependent, with the energy value in higher VRE scenarios being less sensitive to roundtrip efficiency and more supportive of longer storage durations. Long-duration storage value and deployment potential are a function of evolving electricity sector infrastructure, markets, and policy, making it critical to consistently revisit potential long-duration storage contributions to the grid.

14 SOLAR ENERGY↗

Quantifying Energy Storage Density Utilization Trends in Redox Flow Battery Chemistries

The transition to new energy resources is driving the need for efficient energy storage. Redox flow batteries (RFBs) are a promising solution due to their flexible design and safer materials, particularly for long-duration storage applications. Despite these advantages, RFB technologies still have considerable room for growth in terms of utilizing all of their available energy storage density. Herein, we assess RFB energy storage density utilization trends for multiple chemistries by accounting for their unique thermodynamic limits, energy efficiencies, and charge capacity constraints. Of the RFBs chemistries analyzed, most still use less than 60% of their theoretical energy storage capacity. The conventional all-vanadium RFB was the closest to its thermodynamic limit available. Moreover, the volumetric footprint and electrolyte cost analyses demonstrate the real-world implications of these inefficiencies. This analysis further indicates that future studies would benefit from clearer reporting of two key quantities: discharge efficiency, which is more directly tied to practically recoverable energy density than round-trip energy efficiency, and state-of-charge or capacity-utilization limits, which govern access to theoretical storage capacity. More consistent reporting of these factors would improve the accuracy and comparability of energy storage utilization analyses across RFB chemistries.

battery energy storage↗

Current Developments of Carbon Capture Storage and/or Utilization–Looking for Net-Zero Emissions Defined in the Paris Agreement

An essential line of worldwide research towards a sustainable energy future is the materials and processes for carbon dioxide capture and storage. Energy from fossil fuels combustion always generates carbon dioxide, leading to a considerable environmental concern with the values of CO2 produced in the world. The increase in emissions leads to a significant challenge in reducing the quantity of this gas in the atmosphere. Many research areas are involved solving this problem, such as process engineering, materials science, chemistry, waste management, and politics and public engagement. To decrease this problem, green and efficient solutions have been extensively studied, such as Carbon Capture Utilization and Storage (CCUS) processes. In 2015, the Paris Agreement was established, wherein the global temperature increase limit of 1.5 °C above pre-industrial levels was defined as maximum. To achieve this goal, a global balance between anthropogenic emissions and capture of greenhouse gases in the second half of the 21st century is imperative, i.e., net-zero emissions. Several projects and strategies have been implemented in the existing systems and facilities for greenhouse gas reduction, and new processes have been studied. This review starts with the current data of CO2 emissions to understand the need for drastic reduction. After that, the study reviews the recent progress of CCUS facilities and the implementation of climate-positive solutions, such as Bioenergy with Carbon Capture and Storage and Direct Air Capture. Future changes in industrial processes are also discussed.

Regufe, Maria João (ORCID:0000000327748302)↗

Raman Microscopy Analysis of Wyoming CarbonSAFE Pilot Well Thin Sections for Mineralogy and Organic Matter Characterization

Scanning confocal Raman microspectroscopy (RMS) was used to analyze thin sections for inorganic mineral content and for evaluation of organic material (OM). Thin sections were selected from a stratigraphic test well core in the Powder River Basin, Wyoming under the Wyoming CarbonSAFE project. The well was analyzed with a variety of rock and fluid characterization techniques to determine the feasibility of a commercial-scale CO2 storage site. RMS complements other analyses, including traditional petrography, SEM, porosity and permeability, and XRD For this aspect of the study, RMS is especially important in the evaluation of OM in sealing lithologies. At prospective geologic CO2 storage sites, it is imperative to assess the unconventional oil and gas potential of seals to ensure that any future development would not compromise the integrity of the seals. Whole-slide mineralogical surveys were performed on thin sections from various shale and sandstone formations. Surveys were analyzed with Direct Classical Least Squares to identify and quantify minerals. The location and concentration of minerals was color-coded and overlaid on optical images for visualization of the distribution of minerals. Dense hyperspectral Raman mapping of OM was performed on five thin sections. Eleven spectral parameters diagnostic of organic type and thermal maturity were used to train a Partial Least Squares (PLS) calibration against a set of artificially matured samples spanning the pre- to mid-oil window. The PLS was applied to the study set and a post-mature set. Additionally, the PLS was applied to each point in hyperspectral maps for visualization of trends in maturity across sample sets and discrimination of organic matter types within a given map. In inorganic surveys on thin sections, a total of 14 unique inorganic minerals were identified in Raman spectra including quartz, dolomite, calcite, hematite and anhydrite. Shale thin sections tended to be dominated by organic material. OM was often observed mixed with inorganic minerals. Sand- and mudstones were dominated by inorganic minerals. The PLS extrapolated the post-mature set to reflectances >1.2%. The study set ranged from very immature to postmature in the median of map fit-peak parameters. However, point maturity maps indicate that matrix OM in all study samples is immature and that discreet organic particles selected for mapping, which may be inertinites, bias medians towards more-mature. The work demonstrates the capabilities of RMS to perform both whole-slide mineralogy and OM analysis with applications to formation evaluation in oil & gas, carbon sequestration and mining. Here, analysis of sealing formations in the well indicates high levels of immature organic matter that would not be a viable target for future oil production that could compromise the CO2 storage site. The work brings together diverse disciplines from geology and petrography to analytical chemistry, big data and microscopy.

Myers, Grant↗

Shifts in hydropower operation to balance wind and solar will modify effects on aquatic biota

To avoid negative consequences to freshwater biota from climate change, society must complete the transition from fossil to renewable electricity sources. However, temporal patterns in hydropower generation (and flow releases that affect aquatic biota) may change with increased wind and solar penetration. We used power cost modeling to characterize current and future within-day and seasonal patterns in hydropower generation across the Eastern Interconnection in a wet and a dry year. Compared to the baseline, future hydropower generation across the grid decreased during the day and increased before dawn and after dusk. At a project level, such a pattern would suggest 'double peaking' operation (up- and down-ramping before dawn and after dusk, with lower releases midday). Variation in generation was higher in wet years than dry years, foreshadowing possible flow constraints on hydropower flexibility. At the grid scale, projected ramping rates were higher in all seasons. A review of the ecological literature suggests that these changes would shift the timing of invertebrate drift and elevate the risk of nest scouring during up-ramping and the risk of stranding or dewatering during down ramping. Thermal conditions may be moderated by increased ramping. Strategies for adapting to future shifts in the renewable portfolio range from re-regulation in reservoir cascades to providing flow refuge (structures and vegetation) below individual projects. Coordinated basin-scale operation can distribute peaking operation to maintain grid support while restricting local ramping at critical ecological times. In addition, research to design hybrid renewable systems that add battery storage is needed to understand how we can mitigate future risks to aquatic communities while promoting the use of renewable energy. This study, which is among the first to examine ecological side-effects of the shift to renewable energy in freshwater ecosystems, lays out a path toward understanding and navigating changes to flow regimes under the energy transition.

54 ENVIRONMENTAL SCIENCES↗

Summary of International Waste Management Programs (LLNL Input to SNL L3 MS: System-Wide Integration and Site Selection Concepts for Future Disposition Options for HLW)

The Used Fuel Disposition Campaign (UFDC) within the Department of Energy’s Office of Nuclear Energy (DOE-NE) Fuel Cycle Technology (FCT) program has been tasked with investigating the disposal of the nation’s spent nuclear fuel (SNF) and high-level nuclear waste (HLW) for a range of potential waste forms and geologic environments. This Lessons Learned task is part of a multi-laboratory effort, with this LLNL report providing input to a Level 3 SNL milestone (System-Wide Integration and Site Selection Concepts for Future Disposition Options for HLW). The work package number is: FTLL11UF0328; the work package title is: Technical Bases / Lessons Learned; the milestone number is: M41UF032802; and the milestone title is: “LLNL Input to SNL L3 MS: System-Wide Integration and Site Selection Concepts for Future Disposition Options for HLW”. The system-wide integration effort will integrate all aspects of waste management and disposal, integrating the waste generators, interim storage, transportation, and ultimate disposal at a repository site. The review of international experience in these areas is required to support future studies that address all of these components in an integrated manner. Note that this report is a snapshot of nuclear power infrastructure and international waste management programs that is current as of August 2011, with one notable exception. No attempt has been made to discuss the currently evolving world-wide response to the tragic consequences of the earthquake and tsunami that devastated Japan on March 11, 2011, leaving more than 15,000 people dead and more than 8,000 people missing, and severely damaging the Fukushima Daiichi nuclear power complex. Continuing efforts in FY 2012 will update the data, and summarize it in an Excel spreadsheet for easy comparison and assist in the knowledge management of the study cases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of Pretreatment and Aging on the Iodine Capture Performance of Silver-Exchanged Mordenite - 12314

Volatile gas emissions from a nuclear fuel recycle facility in the United States are governed by several key regulations, including 10 CFR 20, 40 CFR 61, and 40 CFR 190. Under 40 CFR 190, the total quantity of iodine that may be released to the environment from the entire fuel cycle is limited to 5 millicuries of I-129 per gigawatt-year of electrical energy produced by the fuel cycle. With a reasonable engineering margin, an iodine decontamination factor (DF) of approximately 1000 will be required for the complete fuel cycle. Off-gas treatment in a fuel reprocessing plant must address several gas streams containing iodine, among a number of volatile radionuclides. Past research and developmental activities identified silver-exchanged mordenite (AgZ) as a very promising sorbent based on its acid resistance, relatively high iodine and methyl iodide capacity, and high achievable DF. Recent studies at ORNL have focused on the impacts of long-term exposure to simulated off-gas streams (aging) and pretreatment on the iodine adsorption performance of hydrogen-reduced silver-exchanged mordenite (Ag{sup 0}Z). Experiments were conducted to determine the effects of long-term exposure to both dry and moist air on the iodine sorption capacity of Ag{sup 0}Z. The data indicates that aging reduces the capacity of Ag{sup 0}Z, which must be accounted for to prevent degradation of DF. Because of its high acid resistance, a AgZ sorbent has been selected specifically for application in treating off-gas streams containing iodine. While extensive tests have been conducted in the United States on a form of this sorbent, the specific material previously tested is no longer commercially available and similar materials are currently being evaluated. As part of this evaluation, tests were conducted to determine the iodine sorption properties of this replacement media and the effects of long-term (up to 6 months) exposure to simulated off-gas streams. The ultimate goal is to develop an understanding of the fundamental phenomena that controls aging for this material and other zeolites that could be considered for use in off-gas treatment in the future. The trends in the study results indicate that the amount of elemental silver observed by XRD increases from 0.3 wt% in vendor-supplied AgZ to approximately 5 wt% by reducing the material with hydrogen. The study also concluded that aging decreases the quantity of elemental silver in the material. After 2 months of aging, the Ag{sup 0} content of an experimental sample was reduced from 5 wt% to about 1.3 wt%. The form into which the elemental silver is converted during aging was not determined. Experimental tests have been initiated to study how aging of Ag{sup 0}Z impacts iodine loading on the zeolite. Loading tests with un-aged Ag{sup 0}Z resulted in an 81% silver utilization. The loading capacity of iodine on Ag{sup 0}Z was reduced with aging in dry air. Material aged for 6 months in dry air had a 40% reduction in iodine loading capacity. Under moist-air aging conditions, a significant decrease in the rate and total loading (∼45% of theoretical) of iodine uptake can be observed beginning with the shortest aging period (i.e., after 1 month) when compared with the loading curve using Ag{sup 0}Z with no aging. Increasing exposure time to the humid air used to age the Ag{sup 0}Z beyond 1 month resulted in a slight additional reduction in capacity to about 35% of theoretical at 2 months. Virtually identical capacity was observed with 4 months of aging. Compared to the non-aged material, the 1 month dry-air aged Ag{sup 0}Z shows about a 35% reduction (approximate) in iodine loading capacity and the 6 month dry-air aged Ag{sup 0}Z shows about a 50% reduction. These studies generated several questions that will be addressed in future tests. They include the following: Is there indeed degradation over time (in storage) in the iodine adsorption performance of Ag{sup 0}Z? Once reduced, how should the Ag{sup 0}Z be stored- under a hydrogen atmosphere, an inert atmosphere, a desiccant, or some other method or combination of methods? Does Ag{sup 0}Z have a 'shelf life' that must be considered after receipt from a vendor and before use in a plant? Also, how should a column of Ag{sup 0}Z be stored offline in a processing plant (parallel column) arrangement? Future tests will also include increasingly challenging aging environments such as acid vapor conditions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Interaction energy and isosteric heat of adsorption between hydrogen and magnesium diboride

Hydrogen storage materials form a crucial research topic for future energy utilization employing hydrogen and among those of interest magnesium diboride (MgB 2 ) has shown its prevalence. In this study, a first-principles analytical adsorption model of one hydrogen molecule in the vicinity of various magnesium diboride crystal surfaces was developed in order to obtain surface thermodynamic properties as a function of molecular and lattice properties. Henry's law constant (K H ) and isosteric heat of adsorption (ΔH ads ) indicators of the affinity between a gaseous molecule and a solid surface are thus calculated. The results in this paper not only address questions pertaining to the first stage of hydrogen storage processes but also advance the understanding of physisorption thermodynamics of a neutral molecule (H 2 ) coming in contact with a layered metallic-like surface (MgB 2 ). Although the model is built from a framework of classical calculations, quantum effects are incorporated as the fractional charge of the ions on the free surfaces, which is essential for the calculation of analytic thermodynamic values that approximate calculations from other methods. To benchmark our theoretical models, periodic density functional calculations were performed to determine the interactions between H 2 and different MgB 2 surfaces from first-principles. By considering both the top and sublayers of MgB 2 in calculating interaction energy, we have analytically and computationally calculated the interaction energies of H 2 molecules and MgB 2 's terminated planes, and witnessed the strong dependence of interaction energies on surface charges. We have also observed a dipole flipping phenomenon which explains the discontinuity seen in the interaction energy graph of Mg(0001). Both analytical and computational results showed heat of adsorption at zero coverage varying at a very low range (<7 kJ mol -1 ).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal Modeling and Simulation of the Packed-bed Thermal Energy Storage Combined with INL Thermal Energy Distribution System

Dynamic Energy Transport and Integration Lab (DETAIL) at Idaho National Laboratory is to support experimental demonstration and validation research on Nuclear-Renewable Hybrid Energy System [1]. The Thermal Energy Distribution System (TEDS) is a thermal-hydraulic flow loop in DETAIL with its own dedicated control system to support the integration of co-located multiple experimental systems, where a packed-bed thermal energy storage (TES) is installed as a thermal buffer and storage unit. Among various TES options, the packed-bed TES is adopted in TEDS because it offers a low-cost single-tank thermal storage option compared to the traditional two-tank TES. However, since the TES tank is filled with granular fillers having different thermophysical properties from those of TES tank wall, there is a potential thermo-mechanical issue to be carefully addressed like thermal ratcheting which may pose a significant design concern for the packed-bed TES tank. Thermal ratcheting is a thermomechanical process caused by the repeated rearrangement of granular filler inside a TES tank during continuous thermal cycling operation of the packed-bed TES system. If the thermally induced stress exceeds the yield strength of a TES tank wall, catastrophic consequences may happen like rupture of the TES tank. Thus, it is important to understand the phenomenon to ensure the robust operation of the packed-bed TES tank. Given that thermal ratcheting is caused by complex interaction of thermal transport in the porous bed and solid mechanics, the accurate prediction of transient thermal behavior of the packed-bed TES tank, which is the focus of this paper, is critical to the reliable thermal ratcheting analysis. This paper discusses the numerical modeling, simulation, and validation studies that are ongoing at INL to investigate the transient thermal behavior of the packed-bed TES. Of particular concern is the transient thermal process occurring in the packed-bed TES unit that is operated in conjunction with the INL TEDS. The main goal of this research is three-fold: (i) provide preliminary insights into the transient thermal behavior of the TEDS TES tank, (ii) support the thermal measurement and validation plan for TEDS experiment, and (iii) provide transient thermal boundary conditions to support the reliable thermal ratcheting analysis of the TEDS TES tank. For the transient thermal modeling and analysis, a CFD model was developed, and the validity of the modeling approach was examined via comparing the numerical simulation results with the experimental data obtained from various design characteristics of packed-bed TES tanks. Then, the present modeling method was applied for the transient thermal analysis of the TEDS TES tank, and the results are discussed along with the potential improvement of data acquisition strategy for the future TEDS experiments for more precise validation study.

25 ENERGY STORAGE↗