Search NASA⌕ Search

SEARCH · Search NASA

Results for “structural mount”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Structural considerations for fabrication and mounting of the AXAF HRMA optics

A methodology is described which minimizes optics distortion in the fabrication, metrology, and launch configuration phases. The significance of finite element modeling and breadboard testing is described with respect to performance analyses of support structures and material effects in NASA's AXAF X-ray optics. The paper outlines the requirements for AXAF performance, optical fabrication, metrology, and glass support fixtures, as well as the specifications for mirror sensitivity and the high-resolution mirror assembly. Analytical modeling of the tools is shown to coincide with grinding and polishing experiments, and is useful for designing large-area polishing and grinding tools. Metrological subcomponents that have undergone initial testing show evidence of meeting force requirements.

Cohen, Lester M.↗

Sun sensor boresight alignment testing for the Halogen Occultation Experiment

The boresight alignment testing for the sun sensor assembly on the Halogen Occultation Experiment (HALOE) is described. The sun sensor assembly consists of three sensors that provide feedback signals for controlling dual axes gimbals. Two energy balancing silicon detectors are operated as wideband sensors in the azimuth and elevation axes. The third sensor is a silicon photodiode array operated as a narrow-band sensor in the elevation axis. These sensors are mounted on a common Invar structure which is mounted to the HALOE telescope. A blackbody was used as the stimulating source to perform the initial boresight alignment and this was checked with a heliostat solar look and a direct solar look. These tests are explained with a comparison between each source used.

Moore, A. S.↗

Silicon Carbide Mounts for Fabry-Perot Interferometers

Etalon mounts for tunable Fabry- Perot interferometers can now be fabricated from reaction-bonded silicon carbide structural components. These mounts are rigid, lightweight, and thermally stable. The fabrication of these mounts involves the exploitation of post-casting capabilities that (1) enable creation of monolithic structures having reduced (in comparison with prior such structures) degrees of material inhomogeneity and (2) reduce the need for fastening hardware and accommodations. Such silicon carbide mounts could be used to make lightweight Fabry-Perot interferometers or could be modified for use as general lightweight optical mounts. Heretofore, tunable Fabry-Perot interferometer structures, including mounting hardware, have been made from the low-thermal-expansion material Invar (a nickel/iron alloy) in order to obtain the thermal stability required for spectroscopic applications for which such interferometers are typically designed. However, the high mass density of Invar structures is disadvantageous in applications in which there are requirements to minimize mass. Silicon carbide etalon mounts have been incorporated into a tunable Fabry-Perot interferometer of a prior design that originally called for Invar structural components. The strength, thermal stability, and survivability of the interferometer as thus modified are similar to those of the interferometer as originally designed, but the mass of the modified interferometer is significantly less than the mass of the original version.

Lindemann, Scott↗

Sensing, interlocking solar module system and installation method

A solar module system is coupled directly to a fixed structure either individually or collectively as an array. Universal mounting brackets attached to the back of each solar panel module each connect to one or more other brackets of adjacent solar panels and/or to mounting feet that anchor to the fixed structure. Mounting brackets interlock with mounting brackets on adjacent solar modules and include a flexible snap coupling mechanism including a locking feature to selectively flexibly connect to and disconnect from other mounting brackets of adjacent solar panels.

14 SOLAR ENERGY↗

Development of a Co-Axial Hot Cathode for Magnetized Ion Source Plasma

Directly heated high temperature cathodes of refractory metals such as tungsten run electric current of more than several tens of amperes. The electric current makes magnetic field around the cathode wire, and the magnetic field causes inhomogeneous emission of electrons from the cathode. To solve this problem we have designed the cathode having a co-axial heater current flow structure, and mounted it in a Bernas-type ion source. A plasma produced by co-axial hot cathode showed a clearer column along the external magnetic field and less displacement in the direction perpendicular to the field than that produced by a hair-pin filament. Stable discharge current as high as 5000 mA was obtained for Ar and BF{sub 3} gases with the co-axial cathode. Boron and phosphorus ion beams were extracted from the source on an actual ion implanter. The ion beam currents were 1.5 times as large as those obtained with a hair-pin filament.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flat TBPS Integration Testing for the CMS Outer Tracker Upgrade

The upcoming High-Luminosity (HL) LHC will significantly increase luminosity, introducing more demanding operating conditions for the CMS detector. To meet these challenges, CMS is undergoing major upgrades, including a complete replacement of its tracking detector. This poster presents recent integration testing efforts conducted at Fermilab on the Flat Tracker Barrel with pixel-strip (PS) modules integration test stand, a subcomponent of the outer tracker located in the central barrel region. In this region, PS modules are mounted on structures that provide mechanical support and cooling, called planks. The testing focuses on validating the integrated system’s thermal and electrical performance. Results from these tests will be discussed, highlighting their importance for ensuring reliable tracker operation in the HL-LHC era.

Salazar Segovia, Itzelli [UC, Davis]↗

System enables dimensional inspection of very large structures

Precision rotary table with an integrated optical tooling bar system enables accurate and rapid measurement of linear and angular dimensions on very large structures of any configuration. The structure is mounted on the turntable, which can be rotated to expose any desired surface.

Simpson, R. R.↗

Space Shuttle Earth Observation sensors pointing and stabilization requirements study

The shuttle orbiter inertial measurement unit (IMU), located in the orbiter cabin, is used to supply inertial attitude reference signals; and, in conjunction with the onboard navigation system, can provide a pointing capability of the navigation base accurate to within plus or minus 0.5 deg for earth viewing missions. This pointing accuracy can degrade to approximately plus or minus 2.0 deg for payloads located in the aft bay due to structural flexure of the shuttle vehicle, payload structural and mounting misalignments, and calibration errors with respect to the navigation base. Drawbacks to obtaining pointing accuracy by using the orbiter RCS jets are discussed. Supplemental electromechanical pointing systems are developed to provide independent pointing for individual sensors, or sensor groupings. The missions considered and the sensors required for these missions and the parameters of each sensor are described. Assumptions made to derive pointing and stabilization requirements are delineated.

Source record↗

Diffraction grating transmission efficiencies for XUV and soft X rays

The manufacture and properties of a grating intended for extrasolar X-ray studies are described. The manufacturing process uses a split laser beam exposing an interference pattern on the photoresist-coated glass plated with a nickel parting layer. The grating, supporting structure, and mounting frame are electrodeposited on the nickel parting layer, and the final product is lifted from the glass substrate by selective etching of the nickel. A model was derived which relates the number of counts received in a given order m as a function of photon wavenumber. A 4-deg beam line was used to measure the efficiencies of gold transmission gratings for diffraction of X-rays in the range of 45 to 275 eV. The experimental results are in good agreement with model calculations.

Schnopper, H. W.↗

Transducers for ultrasonic limb plethysmography

The design, construction, and performance characteristics of ultasonic transducers suitable for limb plethysmography are presented. Both 3-mm-diameter flat-plate and 12-mm-diameter hemispheric ceramic transducers operating at 2 MHz were fitted in 1-mm thick epoxy-resin lens/acoustic-coupling structures and mounted in exercie-EKG electrode housings for placement on the calf using adhesive collars. The effects of transducer directional characteristics on performance under off-axis rotation and the electrical impedances of the transducers were measured: The flat transducer was found to be sensitive to rotation and have an impedance of 800 ohms; the hemispheric transducer, to be unaffected by rotation and have an impedance of 80 ohms. The use of hemispheric transducers as both transmitter and receiver, or of a flat transducer as transmitter and a hemispheric transducer as receiver, was found to produce adequate dimensional measurements, with minimum care in transducer placement, in short-term physiological experiments and long-term (up to 7-day) attachment tests.

Nickell, W. T.↗

A Gimbal sizing analysis for an IPACS rotating assembly

All major components of an integrated power/attitude control system (IPACS) assembly were analyzed for testing, launch, and operational stresses. The conceptual design for the outer gimbal and mounting ring structures were developed and analyzed along with preliminary designs of the pivot and torquer assemblies. Results from the system response analysis and the thermal analysis are also presented. Gimballing of this rotating assembly should present few difficulties as the maximum gimballing rate is quite low. However, the inner gimbal assembly in its current configuration must be modified to develop the system from a laboratory concept to a realistic flight hardware status.

Burke, P. R.↗

High-Precision Coupling Mechanism Operable By Robots

Coupling mechanism has features making it easily operable by hand and suitable for operation by robots: tolerates some initial misalignment, imposes precise final alignment, and protects itself against overtightening. Typically used to mount equipment module on structure. Mechanism includes kinematic mounts, which tolerate small initial misalignment and enforce precise final alignment as two assemblies brought together. Clamping force applied to kinematic mounts via two flexible plates. Bolt and nut tightened on flexible plates to impose spring clamping load. Repeatability of interface tested and found to be better than forty-millionths of inch.

Voellmer, George↗

Laser Metrology System For A Segmented Telescope Reflector

Report describes proposed laser metrology system in far-infrared telescope with segmented primary reflector. Telescope to be flown in outer space and used to observe celestial objects. Laser metrology system mounted on structure that supported secondary telescope reflector and measures relative positions and alignments of segments of primary reflector. System used in pointing as well as in maintaining surface figure.

Lau, Kenneth H.↗

Supersonic Aftbody Closure Wind-Tunnel Testing, Data Analysis, and Computational Results

This paper reports on the model, test, and results from the Langley Supersonic Aftbody Closure wind tunnel test. This project is an experimental evaluation of the 1.5% Technology Concept Aircraft (TCA) aftbody closure model (Model 23) in the Langley Unitary Plan Wind Tunnel. The baseline TCA design is the result of a multidisciplinary, multipoint optimization process and was developed using linear design and analysis methods, supplemented with Euler and Navier-Stokes numerical methods. After a thorough design review, it was decided to use an upswept blade attached to the forebody as the mounting system. Structural concerns dictated that a wingtip support system would not be feasible. Only the aftbody part of the model is metric. The metric break was chosen to be at the fuselage station where prior aft-sting supported models had been truncated. Model 23 is thus a modified version of Model 20. The wing strongback, flap parts, and nacelles from Model 20 were used, whereas new aftbodies, a common forebody, and some new tails were fabricated. In summary, significant differences in longitudinal and direction stability and control characteristics between the ABF and ABB aftbody geometries were measured. Correcting the experimental data obtained for the TCA configuration with the flared aftbody to the representative of the baseline TCA closed aftbody will result in a significant reduction in longitudinal stability, a moderate reduction in stabilizer effectiveness and directional stability, and a moderate to significant reduction in rudder effectiveness. These reductions in the stability and control effectiveness levels of the baseline TCA closed aftbody are attributed to the reduction in carry-over area.

Allen, Jerry↗

The James Webb Space Telescope

The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approx.40K). The JWST Observatory architecture includes the Optical Telescope Element and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The ISIM optical metering structure is a roughly 2.2x1.7x2.2mY, asymmetric frame that is composed of carbon fiber and resin tubes bonded to invar end fittings and composite gussets and clips. The structure supports the SIs, isolates the SIs from the OTE, and supports thermal and electrical subsystems. The structure is attached to the OTE structure via strut-like kinematic mounts. The ISM structure must meet its requirements at the approx.40K cryogenic operating temperature. The SIs are aligned to the structure s coordinate system under ambient, clean room conditions using laser tracker and theodolite metrology. The ISM structure is thermally cycled for stress relief and in order to measure temperature-induced mechanical, structural changes. These ambient-to-cryogenic changes in the alignment of SI and OTE-related interfaces are an important component in the JWST Observatory alignment plan and must be verified.

Nowak, Maria↗

Photogrammetric Metrology for the James Webb Space Telescope Integrated Science Instrument Module

The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approximately 40K). The JWST Observatory architecture includes the Optical Telescope Element and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The ISM optical metering structure is a roughly 2.2x1.7x2.2m, asymmetric frame that is composed of carbon fiber and resin tubes bonded to invar end fittings and composite gussets and clips. The structure supports the SIs, isolates the SIs from the OTE, and supports thermal and electrical subsystems. The structure is attached to the OTE structure via strut-like kinematic mounts. The ISIM structure must meet its requirements at the approximately 40K cryogenic operating temperature. The SIs are aligned to the structure's coordinate system under ambient, clean room conditions using laser tracker and theodolite metrology. The ISIM structure is thermally cycled for stress relief and in order to measure temperature-induced mechanical, structural changes. These ambient-to-cryogenic changes in the alignment of SI and OTE-related interfaces are an important component in the JWST Observatory alignment plan and must be verified. We report on the planning for and preliminary testing of a cryogenic metrology system for ISIM based on photogrammetry. Photogrammetry is the measurement of the location of custom targets via triangulation using images obtained at a suite of digital camera locations and orientations. We describe metrology system requirements, plans, and ambient photogrammetric measurements of a mock-up of the ISIM structure to design targeting and obtain resolution estimates. We compare these measurements with those taken from a well known ambient metrology system, namely, the Leica laser tracker system. We also describe the data reduction algorithm planned to interpret cryogenic data from the Flight structure. Photogrammetry was selected from an informal trade study of cryogenic metrology systems because its resolution meets sub-allocations to ISIM alignment requirements and it is a non-contact method that can in principle measure six degrees of freedom changes in target location. In addition, photogrammetry targets can be readily related to targets used for ambient surveys of the structure. By thermally isolating the photogrammetry camera during testing, metrology can be performed in situ during thermal cycling. Photogrammetry also has a small but significant cryogenic heritage in astronomical instrumentation metrology. It was used to validate the displacement/deformation predictions of the reflectors and the feed horns during thermal/vacuum testing (90K) for the Microwave Anisotropy Probe (MAP). It also was used during thermal vacuum testing (100K) to verify shape and component alignment at operational temperature of the High Gain Antenna for New Horizons. With tighter alignment requirements and lower operating temperatures than the aforementioned observatories, ISIM presents new challenges in the development of this metrology system.

Nowak, Maria↗

Determining Transmission Loss from Measured External and Internal Acoustic Environments

An estimate of the internal acoustic environment in each internal cavity of a launch vehicle is needed to ensure survivability of Space Launch System (SLS) avionics. Currently, this is achieved by using the noise reduction database of heritage flight vehicles such as the Space Shuttle and Saturn V for liftoff and ascent flight conditions. Marshall Space Flight Center (MSFC) is conducting a series of transmission loss tests to verify and augment this method. For this test setup, an aluminum orthogrid curved panel representing 1/8th of the circumference of a section of the SLS main structure was mounted in between a reverberation chamber and an anechoic chamber. Transmission loss was measured across the panel using microphones. Data measured during this test will be used to estimate the internal acoustic environments for several of the SLS launch vehicle internal spaces.

Scogin, Tyler↗