Search NASA⌕ Search

SEARCH · Search NASA

Results for “subsonic tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

High Pressure Quick Disconnect Particle Impact Tests

To determine whether there is a particle impact ignition hazard in the quick disconnects (QDs) in the Environmental Control and Life Support System (ECLSS) on the International Space Station (ISS), NASA Johnson Space Center requested White Sands Test Facility (WSTF) to perform particle impact testing. Testing was performed from November 2006 through May 2007 and included standard supersonic and subsonic particle impact tests on 15-5 PH stainless steel, as well as tests performed on a QD simulator. This report summarizes the particle impact tests completed at WSTF. Although there was an ignition in Test Series 4, it was determined the ignition was caused by the presence of a machining imperfection. The sum of all the test results indicates that there is no particle impact ignition hazard in the ISS ECLSS QDs.

Peralta, Stephen↗

Inlets for high angles of attack

Different inlet designs for high angle of attack STOL and VTOL applications were tested in a subsonic wind tunnel. Three removable entry lips having contraction ratios of 1.30, 1.34 and 1.38 were tested with a single diffuser. The internal contour of each entry lip was an ellipse with a major to minor axis of 2.0. Each lip and diffuser assembly was tested to determine its tolerance to angle of attack, first with a conventional centerbody and then with an extended centerbody. Results indicate that a large improvement in separation angle (determined as a function of lip contraction ratio and inlet flow) was obtained for the extended centerbody for all contraction ratios. Improved inlet tolerance to angle of attack was obtained by reducing the adverse pressure gradient downstream of the throat.

Miller, B. A.↗

The F-15B Lifting Insulating Foam Trajectory (LIFT) Flight Test

A series of flight tests has been performed to assess the structural survivability of space shuttle external tank debris, known as divots, in a real flight environment. The NASA F-15B research test bed aircraft carried the Aerodynamic Flight Test Fixture configured with a shuttle foam divot ejection system. The divots were released in flight at subsonic and supersonic test conditions matching points on the shuttle ascent trajectory. Very high-speed digital video cameras recorded the divot trajectories. The objectives of the flight test were to determine the structural survivability of the divots in a real flight environment, assess the aerodynamic stability of the divots, and provide divot trajectory data for comparison with debris transport models. A total of 10 flights to Mach 2 were completed, resulting in 36 successful shuttle foam divot ejections. Highspeed video was obtained at 2,000 pictures per second for all of the divot ejections. The divots that were cleanly ejected remained structurally intact. The conical frustum-shaped divots tended to aerodynamically trim in both the subsonic and supersonic free-stream flow.

Corda, Stephen↗

Subsonic Dynamics of Stardust Sample Return Capsule

Subsonic dynamic stability tests performed in the NASA Langley 20-Foot Vertical Spin-Tunnel on a 0.238 scale model of the Stardust Sample Return Capsule are discussed. The tests reveal that the blunted 60 degree half-angle cone capsule is dynamically unstable at low subsonic conditions due to the aft location of the center-of-gravity (0.351 body diameters back from the nose). The divergent behavior of the capsule continued when the center-of-gravity was moved to 0.337 and 0.313 body diameters back from the nose. When the center-of-gravity was moved further forward to 0.290 body diameters back from the nose, the vehicle established itself in a limit cycle with amplitude around 10 degrees. Two afterbody modifications were examined which proved unsuccessful in alleviating the instability of the original design. Finally, the addition of different sized parachutes was examined as a means to stabilize the vehicle. The parachute tests indicate that a parachute with equivalent full scale drag area of at least 2.24 ft. is necessary to assure large perturbations are damped.

Mitcheltree, Robert A.↗

Theoretical and experimental study on the ejector augmented jet flap

The analytical concept used in determining the characteristics of jet flap or related propulsive systems suitable for VTOL and STOL applications was examined. The configuration chosen was a two dimensional wing with a biplane flap, having a jet injected on the upper surface of the wing at the flap hinge axis and discharging into the channel between the two elements of the flap. The experimental work was conducted in a two dimensional test installation in a subsonic wind tunnel. The model description, the test conditions, and a summary of the experimental results are presented.

Stewart, H. J.↗

Results of winglet development studies for DC-10 derivatives

The results of investigations into the application of winglets to the DC-10 aircraft are presented. The DC-10 winglet configuration was developed and its cruise performance determined in a previous investigation. This study included high speed and low speed wind tunnel tests to evaluate aerodynamic characteristics, and a subsonic flutter wind tunnel test with accompanying analysis and evaluation of results. Additionally, a configuration integration study employed the results of the wind tunnel studies to determine the overall impact of the installation of winglets on the DC-10 aircraft. Conclusions derived from the high speed and low speed tests indicate that the winglets had no significant effects on the DC-10 stability characteristics or high speed buffet. It was determined that winglets had a minimal effect on aircraft lift characteristics and improved the low speed aircraft drag under high lift conditions. The winglets affected the DC-10 flutter characteristics by reducing the flutter speed of the basic critical mode and introducing a new critical mode involving outer wing torsion and longitudinal bending. The overall impact of winglets was determined to be of sufficient benefit to merit flight evaluation.

Shollenberger, C. A.↗

Advanced Crew Escape Suits (ACES): Particle Impact Test

NASA Johnson Space Center (JSC) requested NASA JSC White Sands Test Facility to assist in determining the effects of impaired anodization on aluminum parts in advanced crew escape suits (ACES). Initial investigation indicated poor anodization could lead to an increased risk of particle impact ignition, and a lack of data was prevalent for particle impact of bare (unanodized) aluminum; therefore, particle impact tests were performed. A total of 179 subsonic and 60 supersonic tests were performed with no ignition of the aluminum targets. Based on the resulting test data, WSTF found no increased particle impact hazard was present in the ACES equipment.

Rosales, Keisa R.↗

Development of a Large Field-of-View PIV System for Rotorcraft Testing in the 14- x 22-Foot Subsonic Tunnel

A Large Field-of-View Particle Image Velocimetry (LFPIV) system has been developed for rotor wake diagnostics in the 14-by 22-Foot Subsonic Tunnel. The system has been used to measure three components of velocity in a plane as large as 1.524 meters by 0.914 meters in both forward flight and hover tests. Overall, the system performance has exceeded design expectations in terms of accuracy and efficiency. Measurements synchronized with the rotor position during forward flight and hover tests have shown that the system is able to capture the complex interaction of the body and rotor wakes as well as basic details of the blade tip vortex at several wake ages. Measurements obtained with traditional techniques such as multi-hole pressure probes, Laser Doppler Velocimetry (LDV), and 2D Particle Image Velocimetry (PIV) show good agreement with LFPIV measurements.

Jenkins, Luther N.↗

The Real-Time Wall Interference Correction System of the NASA Ames 12-Foot Pressure Wind Tunnel

An improved version of the Wall Signature Method was developed to compute wall interference effects in three-dimensional subsonic wind tunnel testing of aircraft models in real-time. The method may be applied to a full-span or a semispan model. A simplified singularity representation of the aircraft model is used. Fuselage, support system, propulsion simulator, and separation wake volume blockage effects are represented by point sources and sinks. Lifting effects are represented by semi-infinite line doublets. The singularity representation of the test article is combined with the measurement of wind tunnel test reference conditions, wall pressure, lift force, thrust force, pitching moment, rolling moment, and pre-computed solutions of the subsonic potential equation to determine first order wall interference corrections. Second order wall interference corrections for pitching and rolling moment coefficient are also determined. A new procedure is presented that estimates a rolling moment coefficient correction for wings with non-symmetric lift distribution. Experimental data obtained during the calibration of the Ames Bipod model support system and during tests of two semispan models mounted on an image plane in the NASA Ames 12 ft. Pressure Wind Tunnel are used to demonstrate the application of the wall interference correction method.

Ulbrich, Norbert↗

An Overview of the Proprotor Performance Test in the 14-­ by 22­-Foot Subsonic Tunnel

This work experimentally investigates the aerodynamic behavior of proprotors across a wide range of angles of attack. These flight conditions are intended to be representative of Urban Air Mobility (UAM) vehicle platforms that utilize articulating propulsors to transition from a vertical takeoff and landing (VTOL) phase typical of a conventional rotor­craft, to an axial mode of forward flight typical of a fixed-­wing aircraft. These data are used to identify the potential limits of lower­ fidelity aerodynamic modeling tools, as well as to inform future acoustic phases of testing. Tests were conducted on two proprotor designs in the NASA Langley 14­- by 22­-Foot Subsonic Tunnel using an articulating propeller test stand. Hover results identified unique flow physics on one of the proprotors, including severe outboard flow separation and perpendicular blade vortex interactions on the outboard portions of the blades. Transition and forward flight conditions yielded very informative trends in terms of both on-­ and off­-axis forces and moments against which low-­fidelity prediction models were compared.

aerodynamics↗

Durability of foam insulation for LH2 fuel tanks of future subsonic transports

Organic foams were tested to determine their suitability for insulating liquid hydrogen tanks of subsonic aircraft. The specimens, including nonreinforced foams and foams with chopped glass reinforcements, flame retardants, and vapor barriers, were scaled to simulate stress conditions in large tanks. The tests were conducted within aluminum tank compartments filled with liquid hydrogen and the boil-off rate was used as the criterion of thermal performance. It was found that while all insulations deteriorated with increased cycles, two nonreinforced polyurethane foams showed no structural deterioration after 4200 thermal cycles (equivalent to 15 years of airline service). It was also found that fiberglass reinforcement and flame retardants impaired thermal performance and reduced useful life of the foams. Vapor barriers enhanced structural integrity without any deterioration in thermal properties.

Sharpe, E. L.↗

Blade-Mounted Flap Control for BVI Noise Reduction Proof-of-Concept Test

This report describes a wind tunnel test of the McDonnell Douglas Helicopter Systems (MDHS) Active Flap Model Rotor at the NASA Langley 14- by 22-Foot Subsonic Tunnel. The test demonstrated that BVI noise reductions and vibration reductions were possible with the use of an active flap. Aerodynamic results supported the acoustic data trends, showing a reduction in the strength of the tip vortex with the deflection of the flap. Acoustic results showed that the flap deployment, depending on the peak deflection angle and azimuthal shift in its deployment schedule, can produce BVI noise reductions as much as 6 dB on the advancing and retreating sides. The noise reduction was accompanied by an increase in low frequency harmonic noise and high frequency broadband noise. A brief assessment of the effect of the flap on vibration showed that significant reductions were possible. The greatest vibration reductions (as much as 76%) were found in the four per rev pitching moment at the hub. Performance improvement cam results were inconclusive, as the improvements were predicted to be smaller than the resolution of the rotor balance.

Dawson, Seth↗

Predicting Wall Modifications for Adaptive Wind Tunnels

Wall shape changed iteratively until it matches streamlines. FLEXWAL predicts upper and lower wall modifications necessary to remove wall-interference effects in adaptive-wall wind tunnels. FLEXWAL aids in elimination of wall-interference effects on objects tested in typical two-dimensional wind tunnel with rigid sidewalls and flexible, solid floor and ceiling boundaries. Iterative procedure valid for subsonic and transonic test conditions, and convergence of method verified both analytically and experimentally. FLEXWAL written in FORTRAN IV for batch execution.

Everhart, J. L.↗

Langley Ground Facilities and Testing in the 21st Century

A strategic approach for retaining and more efficiently operating the essential Langley Ground Testing Facilities in the 21st Century is presented. This effort takes advantage of the previously completed and ongoing studies at the Agency and National levels. This integrated approach takes into consideration the overall decline in test business base within the nation and reduced utilization in each of the Langley facilities with capabilities to test in the subsonic, transonic, supersonic, and hypersonic speed regimes. The strategy accounts for capability needs to meet the Agency programmatic requirements and strategic goals and to execute test activities in the most efficient and flexible facility operating structure. The structure currently being implemented at Langley offers agility to right-size our capability and capacity from a national perspective, to accommodate the dynamic nature of the testing needs, and will address the influence of existing and emerging analytical tools for design. The paradigm for testing in the retained facilities is to efficiently and reliably provide more accurate and high-quality test results at an affordable cost to support design information needs for flight regimes where the computational capability is not adequate and to verify and validate the existing and emerging computational tools. Each of the above goals are planned to be achieved, keeping in mind the increasing small industry customer base engaged in developing unpiloted aerial vehicles and commercial space transportation systems.

Ambur, Damodar R.↗

Wind-Tunnel Tests of a 0.16-Scale Model of the Douglas MX-656 Airplane at High Subsonic Speeds: Stability and Control Characteristics - 1

Wind tunnel tests of the 0.16-scale Douglas MX-656 model were made at low and high subsonic Mach numbers to investigate the static longitudinal- and lateral stability characteristics. The tests shows that undesirable changes in longitudinal stability at the stall were apparently caused by an altered downwash pattern at the tail. The jettisonable nose fins were highly destabilizing. Compressibility effects for the test Mach numbers were not detrimental to the longitudinal- or lateral-stability characteristics.

Hamilton, William T.↗

Analysis and testing of compressible flow ejectors with variable area mixing tubes.

An analytical model has been developed to predict the flow behavior within axisymmetric single-nozzle ejectors employing variable-area mixing tubes. The primary flow may be supersonic or subsonic and may have a different stagnation temperature from the subsonic secondary flow. Tests were performed on an ejector with an 800 F supersonic (M = 2.72) primary jet to evaluate the analytical model. Measured velocity profiles, temperature profiles, and wall static pressure distributions are presented and compared to the analytical predictions. Agreement is generally good.

Hickman, K. E.↗

Effect of nozzle lateral spacing on afterbody drag and performance of twin-jet afterbody models with convergent-divergent nozzles at Mach numbers up to 2.2

Twin-jet afterbody models were investigated by using two balances to measure the thrust-minus-total drag and the afterbody drag, separately, at static conditions and at Mach numbers up to 2.2 for an angle of attack of 0 deg. Hinged-flap convergent-divergent nozzles were tested at subsonic-cruise- and maximum-afterburning-power settings with a high-pressure air system used to provide jet-total-pressure ratios up to 20. Two nozzle lateral spacings were studied, using afterbodies with similar interfairing shapes but with different longitudinal cross-sectional area distributions. Alternate, blunter, interfairings with different shapes for the two spacings, which produced afterbodies having identical cross-sectional area progressions corresponding to an axisymmetric minimum wave-drag configuration, were also tested. The results indicate that the wide-spaced configurations improved the flow field around the nozzles, thereby reducing drag on the cruise nozzles; however, the increased surface and projected cross-sectional areas caused an increase in afterbody drag. Except for a slight advantage with cruise nozzles at subsonic speeds, the wide-spaced configurations had the higher total drag at all other test conditions.

Pendergraft, O. C., Jr.↗

Reflectivity characterization of in-flow acoustic floor treatment for the NASA Langley 14- by 22-Foot Subsonic Tunnel

An experimental campaign was performed to assess acoustic modifications to the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel. Recent acoustic test campaigns in this facility have emphasized the reduction of aerodynamic noise due to flow scrubbing across acoustically treated floor baskets. However, the measures implemented to address this noise contaminant have resulted in the installation of floor basket coverings of high acoustic reflectivity. Therefore, a controlled test campaign was performed to identify a suitable acoustic basket configuration in terms of both acoustic absorptivity and reduced flow scrubbing noise. This test campaign was conducted in two phases: the first in an anechoic chamber facility on a single acoustic basket panel to identify a notional configuration of acceptable absorptivity, and the second in a complete floor basket installation checkout test in the NASA Langley 14- by 22-Foot Subsonic Tunnel. Results show that the newly implemented floor treatment exhibits suitable performance in both desired categories of acoustic absorptivity and reduced flow scrubbing noise. This campaign has also validated the effectiveness and usefulness of the anechoic chamber test configuration as a means of assessing acoustic reflections at oblique angles of incidence.

Nikolas S Zawodny↗