At least 145 records · Page 8

LLRF System Analysis for the Fermilab PIP-II Superconducting LINAC

PIP-II is a superconducting linac that is in the initial acceleration chain for the Fermilab accelerator complex. The RF system consists of a warm front-end with an RFQ and buncher cavities along with 25 superconducting cryo-modules comprised of cavities with five different acceleration \(β\). The LLRF system for the linac has to provide field and resonance control for a total of 125 RF cavities. Various components of the LLRF system have been tested with and without beam at the PIP-II test stands. The LLRF system design is derived from the LCLS-II project with its self-excited loop architecture used in the majority of the cryo-modules. The PIP-II beam loading at 2 mA is much higher than the LCLS-II linac. The control system architecture is analyzed and evaluated for the operational limits of feedback gains and their ability to meet the project regulation requirements for cavity field amplitude and phase regulation.

Varghese, P. [Fermilab] (ORCID:0009000925131983)↗

RF noise suppression using the photodielectric effect in semiconductors

Technique using photodielectric effect of semiconductor in high-Q superconductive cavity gives initial improvement of 2-4 db in signal-to-noise enhancement of conventional RF communication systems. Wide band signal plus noise can be transmitted through a narrow-band cavity due to parametric perturbation of the cavity frequency or phase.

Arndt, G. D.↗

Advances in Nb 3 Sn superconducting radiofrequency cavities towards first practical accelerator applications

Abstract Nb 3 Sn is a promising next-generation material for superconducting radiofrequency cavities, with significant potential for both large scale and compact accelerator applications. However, so far, Nb 3 Sn cavities have been limited to continuous wave accelerating fields <18 MV m −1 . In this paper, new results are presented with significantly higher fields, as high as 24 MV m −1 in single cell cavities. Results are also presented from the first ever Nb 3 Sn-coated 1.3 GHz 9-cell cavity, a full-scale demonstration on the cavity type used in production for the European XFEL and LCLS-II. Results are presented together with heat dissipation curves to emphasize the potential for industrial accelerator applications using cryocooler-based cooling systems. The cavities studied have an atypical shiny visual appearance, and microscopy studies of witness samples reveal significantly reduced surface roughness and smaller film thickness compared to typical Nb 3 Sn films for superconducting cavities. Possible mechanisms for increased maximum field are discussed as well as implications for physics of RF superconductivity in the low coherence length regime. Outlook for continued development is presented.

43 PARTICLE ACCELERATORS↗

Challenges to Reliable Production Nitrogen Doping of Nb for SRF Accelerating Cavities

Over the last several years, alloying of the surface layer of niobium SRF cavities has been demonstrated to beneficially lower the superconducting RF surface resistance. Nitrogen, titanium, and oxygen have all been demonstrated as effective alloying agents, occupying interstitial sites in the niobium lattice within the RF penetration depth and even deeper, when allowed to thermally diffuse into the surface at appropriate temperatures. The use of nitrogen for this function has been often termed ’nitrogen doping’ and is being applied in the LCLS-II and LCLS-II HE projects. We report characterization studies of the distribution of nitrogen into the exposed niobium surface and how such distribution is affected by the quality of the vacuum furnace environment in which the doping takes place, and the complexity of nitride crystal growth on different grain orientations of surface niobium. Using state-of-the-art quantification methods by dynamic secondary ion mass spectrometry (SIMS) depth profiling in niobium, we identify several phenomena involving furnace-sourced contamination. We also highlight a potential issue with N₂ flow constraints from the flange ’caps’ used during heat treatments.

Reece, Charles↗

Effect of duration of 120 oC baking on the performance on superconducting radio frequency niobium cavities

Over the last decade much attention was given in increasing the quality factor of superconducting radio frequency (SRF) cavities by impurity doping. Prior to the era of doping, the final cavity processing technique to achieve the high accelerating gradient includes the ?in situ? low temperature baking of SRF cavities at temperature ~ 120 oC for several hours. Here, we present the results of a series of measurements on 1.3 GHz TESLA shape single-cell cavities with successive low temperature baking at 120 oC up to 96 hours. The experimental data were analyzed with available theory of superconductivity to elucidate the effect of the duration of low temperature baking on the superconducting properties of cavity materials as well as the rf performance. In addition, the rf loss related to the trapping of residual magnetic field refereed as flux trapping sensitivity was measured with respect to the duration of 120 oC bake.

Khanal, B. D.↗

Forged Ingot Niobium Technology for Accelerator Applications and Scientific Frontiers

We report the rf performance of several single-cell superconducting radiofrequency cavities frequency ranging from 1.3-3.0 GHz after low temperature baking in nitrogen environment The cavities are treated at different temperature in the range of (120-160oC) for extended period of time (~24-48 hours) with nitrogen gas injection in the furnace. The improvement in Q0 with Q-rise in some case was observed when nitrogen gas was injected at elevated temperature (~250-290 oC) and held at the temperature range 120-200 oC without any degradation in accelerating gradient over the baseline performance. The temperature and time of baking play significant role in dependence of quality factor on accelerating gradient.

Khanal, B.↗

LLRF System for the Fermilab PIP-II Superconducting LINAC

PIP-II is an 800 MEV superconducting linac that is in the initial acceleration chain for the Fermilab accelerator complex. The RF system consists of a warm front-end with an ion source, RFQ and buncher cavities along with 25 superconducting cryo-modules comprised of five different acceleration \(\beta\). The LLRF system for the LINAC has to provide field and resonance control for a total of 125 RF cavities.The LLRF system design is in the final design review phase and will enter the production phase next year. The PIP-II project is an international collaboration with various partner labs contributing subsystems. The LLRF system design for the PIP-II Linac is presented and the specification requirements and system performance in various stages of testing are described in this paper.

43 PARTICLE ACCELERATORS↗

Fabrication and Radio Frequency Properties of 3-GHz SRF Cavities Coated with MgB 2

Magnesium diboride (MgB 2 ) is considered a potential material for superconducting radio frequency cavities. MgB 2 coated Cu cavity will allow for a higher operational temperature than a bulk Nb cavity because of the higher transition temperature of MgB 2 and the high thermal conductivity of Cu. Using the hybrid physical chemical vapor deposition technique, MgB 2 coatings were successfully achieved on the inner wall of 3-GHz Cu cavities. The surface and superconducting properties of the coatings were characterized using small samples on Cu plugs mounted at different locations of mock cavities. RF measurement of a MgB 2 coated single-cell 3-GHz test cavity was carried out and it showed superconducting transition at 36 K. Here, the quality factor of this test cavity was lower than expected due to poor connectivity and inclusion of Mg-Cu alloy in the MgB 2 coating.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Fast Mechanical Tuner for SRF Cavities

There is a particular need for fast tuners and phase shifters for advanced superconducting accelerator RF systems. The tuners based on ferrite, ferroelectric and piezo materials are commonly used. However, those methods suffer from one or another issue of high power loss, slow response, and narrow tuning range. We propose a robust, fast (up to ~5 MHz/sec), high efficient mechanical tuner for SRF cavities operating at the frequency 50 MHz. We develop an external mechanical tuner that is strongly coupled to the cavity. The tuner design represents a trade-off of high efficiency (low RF losses and low heat flux) and frequency tunability range. Our approach solves this trade-off issue. We propose RF design which exploits two coupled resonators so that a main high-field cavity is controlled with a small tunable resonator with a flexible metallic wall operating in a relatively low RF field. Simulations, carried out for a 7.5 MV/m 50 MHz SRF Quarter Wave Resonator (QWR), show that frequency tunability at level 10⁻³ is obtainable.

43 PARTICLE ACCELERATORS↗

LCLS-II Cryomodules Production Experience and Lessons Learned Towards LCLS-II-HE Project

LCLS-II is an upgrade project for the linear coherent light source (LCLS) at SLAC. The LCLS-II linac consists of thirty-five 1.3 GHz and two 3.9 GHz superconducting RF (SRF) continuous wave (CW) cryomodules with high quality factor cavities. Cryomodules were produced at Fermilab and at Jefferson Lab in collaboration with SLAC. Fermilab successfully completed the assembly, testing and delivery of seventeen 1.3 GHz and three 3.9 GHz cryomodules. LCLS-II-HE is a planned upgrade project to LCLS-II. The LCLS-II-HE linac will consist of twenty-three 1.3 GHz cryomodules with high gradient and high quality factor cavities. This paper presents LCLS-II-HE cryomodule production plans, emphasizing the improvements done based on the challenges, mitigations, and lessons learned from LCLS-II.

43 PARTICLE ACCELERATORS↗

MAGNETIC FLUX EXPULSION IN SUPERCONDUCTING RADIO-FREQUENCY NIOBIUM CAVITIES MADE FROM COLD WORKED NIOBIUM

Trapped residual magnetic field during the cool down of superconducting radio frequency (SRF) cavities is one of the primary sources of RF residual losses leading to lower quality factor. Historically, SRF cavities have been fabricated from high purity fine grain niobium with grain size ~50 to 100 µm as well as large grain with grain size of the order of few centimeters. Non-uniform recrystallization of fine-grain Nb cavities after the post fabrication heat treatment leads to higher flux trapping during the cool down, and hence the lower quality factor. We fabricated two 1.3 GHz single cell cavities from cold-worked niobium from different vendors and processed along with cavities made from SRF grade Nb. The flux expulsion and flux trapping sensitivity were measured after successive heat treatments in the range 800 to 1000°C. The flux expulsion from cold-worked fine-grain Nb cavities improves after 800°C/3h heat treatments and it becomes similar to that of standard fine-grain Nb cavities when the heat treatment temperature is higher than 900°C.

Khanal, B. D.↗

MAGNETIC FLUX EXPULSION IN SUPERCONDUCTING RADIO-FREQUENCY NIOBIUM CAVITIES MADE FROM COLD WORKED NIOBIUM

Trapped residual magnetic field during the cool down of superconducting radio frequency (SRF) cavities is one of the primary sources of RF residual losses leading to lower quality factor. Historically, SRF cavities have been fabricated from high purity fine grain niobium with grain size ~50 to 100 µm as well as large grain with grain size of the order of few centimeters. Non-uniform recrystallization of fine-grain Nb cavities after the post fabrication heat treatment leads to higher flux trapping during the cool down, and hence the lower quality factor. We fabricated two 1.3 GHz single cell cavities from cold-worked niobium from different vendors and processed along with cavities made from SRF grade Nb. The flux expulsion and flux trapping sensitivity were measured after successive heat treatments in the range 800 to 1000°C. The flux expulsion from cold-worked fine-grain Nb cavities improves after 800°C/3h heat treatments and it becomes similar to that of standard fine-grain Nb cavities when the heat treatment temperature is higher than 900°C.

Khanal, B. D.↗

Higher order mode analysis of a 915 MHz 2-cell cavity for a prototype industrial accelerator

A possible solution to reduce the complexity posed by the cryogenic systems in a superconducting RF accelerator for industrial applications, is to capitalize on the advances achieved by the Nb3Sn superconducting RF technology, as well as the feasibility of a reliable 4 K cooling system, based on commercial cryocoolers. Following this philosophy, the conceptual design for a prototype, conduction-cooled, 4 MeV, 20 kW SRF electron linac, is being developed at Jefferson Lab. Such design is based on a 915 MHz two-cell Nb3Sn cavity. In this contribution, we present the proposed cavity design, including the fundamental power coupler, and the analysis of the Higher Order Modes, using numerical simulations to estimate the potentially dangerous modes and to provide the requirements for damping for reliable operations with a cryocooler.

Rimmer, Robert↗

Processing and Test Result of 650 MHz 50 kW CW Prototype Couplers for PIP-II Project

For PIP-II project Fermilab is developing 650 MHz couplers to deliver up to 50 kW CW RF power to the superconducting low-beta (LB650) and high-beta (HB650) cavities. To meet project requirements two different designs of the couplers were proposed, one is conventional design with copper plated stainless steel walls. In second design (EM-shielded) a copper screen is used to shield stainless steel wall from electromagnetic field. For prototyping we built two couplers of each type and tested them at 50kW with full reflection at different reflection phases. In each test the assembly of two couplers were processed with DC bias up to +5 kV, starting with short pulses and ramping power up to 100 kW. Final run for 2 hours in CW mode at 50 kW to reach equilibrium temperature regime and qualify couplers. One pair of couplers was also processed without DC bias. Finally, all four couplers demonstrated full requirements and were qualified. Based on test results the conventional coupler with some modification was chosen as a baseline design. Modified version of coupler is now ordered for prototype of HB650 cryomodule. In paper we will discuss details of coupler processing and results

43 PARTICLE ACCELERATORS↗

Understanding the Role of Extrinsic Impurities in Bulk Nb SRF Cavities

High gradient and high quality factor superconducting radiofrequency (SRF) cavities are essential for efficient particle acceleration in next-generation accelerators. This work demonstrates that the superconducting performance of bulk niobium can be enhanced through a controlled introduction of interstitial oxygen and nitrogen. Thermal and chemical surface treatments modify the concentration and distribution of these impurities, enabling systematic tuning of SRF cavity performance. By combining cavity RF measurements with quantitative materials characterizations, we isolate the impact of impurity concentration on BCS surface resistance and identify the mechanisms by which interstitial impurities alter the superconducting properties of niobium. We find that nitrogen is an order of magnitude more effective than oxygen in reducing BCS resistance at 16 MV/m and that the reduction arises from a combination of mean free path optimization and superconducting gap enhancement. Using these insights, we develop a predictive model that estimates cavity performance directly from room temperature sample material studies, reducing the reliance on full-scale cryogenic tests for surface treatment development. We then apply this model to explore co-doping strategies, demonstrating that combining interstitial oxygen and nitrogen achieves a synergistic reduction in BCS resistance. These results establish co-doping as a viable path for the development of surface-engineered niobium for future high quality factor SRF applications.

Hu, Hannah [Chicago U.]↗

Signatures of enhanced superconducting properties in niobium cavities

Superconducting radio-frequency (SRF) niobium cavities are critical for modern particle accelerators, as well as for advancing superconducting quantum systems and enabling ultrasensitive searches for new physics. In this work, we report a systematic observation of an anomalous frequency dip in Nb cavities, which occurs at temperatures just below the critical temperature (𝑇𝑐 ), indicative of enhanced superconducting properties at 𝑇 ≪ 𝑇 𝑐 . The magnitude of this dip is strongly correlated with the rf surface resistance, impurity distribution near the surface, and 𝑇𝑐 . Additionally, we report measurements of the coherence peak in the ac conductivity of two Nb SRF cavities processed using distinct methods. By comparing recent theories developed to model this experimental data, we show that the frequency-dip feature, larger coherence peak height, and reduction in the temperature-dependent surface resistance with rf current occur at minimal but finite levels of disorder.

43 PARTICLE ACCELERATORS↗

Commissioning of a two-target DC cylindrical magnetron sputter coater for depositing Nb 3 Sn film on Nb superconducting radiofrequency cavities

A DC cylindrical magnetron sputter coater was commissioned and used to coat Nb 2.6 GHz superconducting radiofrequency (SRF) cavity with Nb 3 Sn. The sputter coater has two identical cylindrical magnetrons that can move, with a controlled speed, along the axis of the SRF cavity to coat the inside surface of the cavity. The design of the sputter coater is discussed, along with its performance. Initially, a sample holder that allows coating on flat substrates at positions similar to the equator and beam tubes of a 2.6 GHz SRF cavity was used to test conditions for fabricating Nb 3 Sn layers. Multilayers of Nb and Sn were sequentially sputtered on flat Nb and sapphire substrates mounted on the equivalent positions of the cavity's beam tubes and the equator using the two identical cylindrical magnetrons. Then, the Nb/Sn multilayers were annealed at 950 °C for 3 h. Here, the ~1.2 μm thick Nb 3 Sn film did not show any other Nb–Sn compounds and had a superconducting transition temperature of 17.61–17.76 K. The 2.6 GHz SRF cavity was coated using similar conditions as flat samples. Cryogenic RF testing of the Nb 3 Sn-coated cavity demonstrated a quality factor of 3.2 × 10 8 at an accelerating gradient of 5 MV/m at 4.4 K.

43 PARTICLE ACCELERATORS↗