Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchrotron beamline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Adaptable SEC‐SAXS data collection for higher quality structure analysis in solution

Abstract The two major challenges in synchrotron size‐exclusion chromatography coupled in‐line with small‐angle x‐ray scattering (SEC‐SAXS) experiments are the overlapping peaks in the elution profile and the fouling of radiation‐damaged materials on the walls of the sample cell. In recent years, many post‐experimental analyses techniques have been developed and applied to extract scattering profiles from these problematic SEC‐SAXS data. Here, we present three modes of data collection at the BioSAXS Beamline 4–2 of the Stanford Synchrotron Radiation Lightsource (SSRL BL4‐2). The first mode, the High‐Resolution mode, enables SEC‐SAXS data collection with excellent sample separation and virtually no additional peak broadening from the UHPLC UV detector to the x‐ray position by taking advantage of the low system dispersion of the UHPLC. The small bed volume of the analytical SEC column minimizes sample dilution in the column and facilitates data collection at higher sample concentrations with excellent sample economy equal to or even less than that of the conventional equilibrium SAXS method. Radiation damage problems during SEC‐SAXS data collection are evaded by additional cleaning of the sample cell after buffer data collection and avoidance of unnecessary exposures through the use of the x‐ray shutter control options, allowing sample data collection with a clean sample cell. Therefore, accurate background subtraction can be performed at a level equivalent to the conventional equilibrium SAXS method without requiring baseline correction, thereby leading to more reliable downstream structural analysis and quicker access to new science. The two other data collection modes, the High‐Throughput mode and the Co‐Flow mode, add agility to the planning and execution of experiments to efficiently achieve the user's scientific objectives at the SSRL BL4‐2.

Matsui, Tsutomu↗

Dynamic Measurements of the Structural Evolution of Material Defects at the Mesoscale

This is a technical report to be published as part of the FY2021 annual overview package. We have designed experiments and developed analytical methods using images from x-ray and electron microscopy in order to quantify the behavior of crystal dislocation defects at their native nanometer-length and micro-length scales. The results of these analyses are used to directly inform theoretical physics models and guide interpretation of dark field x-ray microscopy (DFXM) images that offer spatial resolution surpassing the resolution of beamline optics. Additionally, we developed new analytical methods to automate the alignment of optics hardware used in both synchrotron and x-ray free electron laser beamline facilities. The tools and workflows developed for this project are now being deployed as proof-of-concept in reaction history analysis (RHA) for future programmatic integration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phasing Magnet for CSX-2 Beamline at NSLS-II

A phasing magnet has been developed at National Synchrotron Light Source II (NSLS-II) for the Coherent Soft X-ray Scattering (CSX) beamline. The phasing magnet will be located at the center of the straight section in between two identical and independent variably polarized APPLE-II devices. Based on Permanent Magnet technology, the phasing magnet has been designed to achieve the required electron beam delay to properly adjust the phase matching of these two consecutive EPUs (Elliptically Polarizing Undulators) and ensure a positive interference between the photon beam emitted in each device. Also this paper will describe the mechanical and magnetic design together with the final field measurements and magnetic tuning results. Also, the spectral performance of the two EPUs and the method used to properly set the field strength of the phasing magnet for any given radiation wavelength and polarization mode will be presented as well.

36 MATERIALS SCIENCE↗

IRIXS: a resonant inelastic X-ray scattering instrument dedicated to X-rays in the intermediate energy range

A new resonant inelastic X-ray scattering (RIXS) instrument has been constructed at beamline P01 of the PETRA III synchrotron. This instrument has been named IRIXS (intermediate X-ray energy RIXS) and is dedicated to X-rays in the tender-energy regime (2.5–3.5 keV). The range covers the L 2,3 absorption edges of many of the 4delements (Mo, Tc, Ru, Rh, Pd and Ag), offering a unique opportunity to study their low-energy magnetic and charge excitations. The IRIXS instrument is currently operating at the Ru L 3 -edge (2840 eV) but can be extended to the other 4d elements using the existing concept. The incoming photons are monochromated with a four-bounce Si(111) monochromator, while the energy analysis of the outgoing photons is performed by a diced spherical crystal analyzer featuring (10$\bar{2}$ lattice planes of quartz (SiO 2 ). A total resolution of 100 meV (full width at half-maximum) has been achieved at the Ru L 3 -edge, a number that is in excellent agreement with ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Speciation mapping of the oxidation layer on aged uranium dioxide using scanning transmission x-ray spectromicroscopy

In this study, UO 2 was aged in humid air and prepared as a thin section using a focused ion beam (FIB) instrument. The specimen was measured using synchrotron radiation spectromicroscopy techniques at the Beamline 11.0.2 STXM end station of the Advanced Light Source (ALS). Non-negative matrix factorization (NMF) methods were used to identify and map three component x-ray absorption near-edge structure (XANES) spectra in the oxygen K-edge data, revealing a surface layer of U 4 O 9 with a thickness of 206 ± 21 nm, and the bulk of the sample remaining as UO 2 . Uranium N 4,5 -edge XANES spectromicroscopy supports these results. The diffusion-controlled parabolic rate constant for UO 2 oxidation to U 4 O 9 was calculated from the observed layer thickness and compared to literature values. Complementary transmission electron microscopy (TEM) was used to image the sample and identify the phases present in various regions, confirming the STXM results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation shielding analysis of the small-angle X-ray scattering flight tube end station of APS upgrade project

The CSSI beamline of the APSU will have a 20.5 m long, 2.75 m diameter SS end station designed to accept pink beam. In this work, the radiation shielding analysis of this end station is analyzed using STAC8 and FLUKA codes. Effect of mirror properties such as reflectivity, coating, inclination and roughness as well as variation in the steel composition are also studied. 8 mm thick SS is found to be adequate if the source is defined by a pinhole and the white beam is reflected with two mirrors inclined at 3.0 mradian or more. The dose rates from monochromatic beams are found to be below the desired levels when the XOP calculated bandwidth (BW) are used while the use of a flat 0.1% BW requires the mirror inclinations to be above 2.5 mradian or more. STAC8 results are consistently higher than the FLUKA results by about 1.5–2.0 times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous imaging and diffraction in the dynamic diamond anvil cell

The ability to visualize a sample undergoing a pressure-induced phase transition allows for the determination of kinetic parameters, such as the nucleation and growth rates of the high-pressure phase. For samples that are opaque to visible light (such as metallic systems), it is necessary to rely on x-ray imaging methods for sample visualization. Here, we present an experimental platform developed at beamline P02.2 at the PETRA III synchrotron radiation source, which is capable of performing simultaneous x-ray imaging and diffraction of samples that are dynamically compressed in piezo-driven diamond anvil cells. This setup utilizes a partially coherent monochromatic x-ray beam to perform lensless phase contrast imaging, which can be carried out using either a parallel- or focused-beam configuration. The capabilities of this platform are illustrated by experiments on dynamically compressed Ga and Ar. Melting and solidification were identified based on the observation of solid/liquid phase boundaries in the x-ray images and corresponding changes in the x-ray diffraction patterns collected during the transition, with significant edge enhancement observed in the x-ray images collected using the focused-beam. These results highlight the suitability of this technique for a variety of purposes, including melt curve determination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New dynamic diamond anvil cell for time-resolved radial x-ray diffraction

The dynamic diamond anvil cell (dDAC) is a recently developed experimental platform that has shown promise for studying the behavior of materials at strain rates ranging from intermediate to quasi-static and shock compression regimes. Combining dDAC with time-resolved x-ray diffraction (XRD) in the radial geometry (i.e., with incident x-rays perpendicular to the axis of compression) enables the study of material properties such as strength, texture evolution, and deformation mechanisms. This work describes a radial XRD dDAC setup at beamline P02.2 (Extreme Conditions Beamline) at DESY’s PETRA III synchrotron. Time-resolved radial XRD data are collected for titanium, zirconium, and zircon samples, demonstrating the ability to study the strength and texture of materials at compression rates above 300 GPa/s. In addition, the simultaneous optical imaging of the DAC sample chamber is demonstrated. The ability to conduct simultaneous radial XRD and optical imaging provides the opportunity to characterize plastic strain and deviatoric strain rates in the DAC at intermediate rates, exploring the strength and deformation mechanisms of materials in this regime.

47 OTHER INSTRUMENTATION↗

Introducing new resonant soft x-ray scattering capability in SSRL

Resonant soft x-ray scattering (RSXS) is a powerful technique for probing both spatial and electronic structures within solid-state systems. Here, we present a newly developed RSXS capability at beamline 13-3 of the Stanford Synchrotron Radiation Lightsource, designed to enhance materials science research. This advanced setup achieves a base sample temperature as low as 9.8 K combined with extensive angular motions (azimuthal ϕ and flipping χ), enabling comprehensive exploration of reciprocal space. Two types of detectors—an Au/GaAsP Schottky photodiode and a charge-coupled device detector with over 95% quantum efficiency—are integrated to effectively capture scattered photons. Extensive testing has confirmed the enhanced functionality of this RSXS setup, including its temperature and angular performance. The versatility and effectiveness of the system have been demonstrated through studies of various materials, including superlattice heterostructures and high-temperature superconductors.

Kuo, Cheng-Tai [SLAC National Accelerator Laborato↗

Five-analyzer Johann spectrometer for hard X-ray photon-in/photon-out spectroscopy at the Inner Shell Spectroscopy beamline at NSLS-II: design, alignment and data acquisition

Here, a recently commissioned five-analyzer Johann spectrometer at the Inner Shell Spectroscopy beamline (8-ID) at the National Synchrotron Light Source II (NSLS-II) is presented. Designed for hard X-ray photon-in/photon-out spectroscopy, the spectrometer achieves a resolution in the 0.5–2 eV range, depending on the element and/or emission line, providing detailed insights into the local electronic and geometric structure of materials. It serves a diverse user community, including fields such as physical, chemical, biological, environmental and materials sciences. This article details the mechanical design, alignment procedures and data-acquisition scheme of the spectrometer, with a particular focus on the continuous asynchronous data-acquisition approach that significantly enhances experimental efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time machine-learning-driven control system of a deformable mirror for achieving aberration-free X-ray wavefronts

A neural-network machine learning model is developed to control a bimorph adaptive mirror to achieve and preserve aberration-free coherent X-ray wavefronts at synchrotron radiation and free electron laser beamlines. The controller is trained on a mirror actuator response directly measured at a beamline with a real-time single-shot wavefront sensor, which uses a coded mask and wavelet-transform analysis. The system has been successfully tested on a bimorph deformable mirror at the 28-ID IDEA beamline of the Advanced Photon Source at Argonne National Laboratory. It achieved a response time of a few seconds and maintained desired wavefront shapes (e.g., a spherical wavefront) with sub-wavelength accuracy at 20 keV of X-ray energy. This result is significantly better than what can be obtained using a linear model of the mirror’s response. The developed system has not been tailored to a specific mirror and can be applied, in principle, to different kinds of bending mechanisms and actuators.

47 OTHER INSTRUMENTATION↗

Design of monolithic piezoelectric bimorph mirrors made from lithium niobate

Recent advances in deformable mirrors based on monolithic piezoelectric substrates, such as lithium niobate, have the potential to improve the image quality of X-ray optical systems on synchrotron and free-electron laser beamlines and microscopes. However, the quantitative relationship between design parameters and the deformed shape has not been readily available in the literature. We present an analytical model, validated through finite element analysis, enabling calculation of tangential and sagittal curvatures based on mirror dimensions, crystallographic orientation, and applied voltage. We demonstrate that through the selection of material orientation, it is possible to achieve different deformed shapes (sphere, cylinder, or hyperbolic paraboloid). This methodology can be generalized to other piezoelectric materials and substrate-integrated actuator systems.

Marzari, Francesco [University of Trento (Italy); ↗

New dynamic diamond anvil cell for time-resolved radial x-ray diffraction

The dynamic diamond anvil cell (dDAC) is a recently developed experimental platform that has shown promise for studying the behavior of materials at strain rates ranging from intermediate to quasi-static and shock compression regimes. Combining dDAC with time-resolved x-ray diffraction (XRD) in the radial geometry (i.e., with incident x-rays perpendicular to the axis of compression) enables the study of material properties such as strength, texture evolution, and deformation mechanisms. This work describes a radial XRD dDAC setup at beamline P02.2 (Extreme Conditions Beamline) at DESY’s PETRA III synchrotron. Time-resolved radial XRD data are collected for titanium, zirconium, and zircon samples, demonstrating the ability to study the strength and texture of materials at compression rates above 300 GPa/s. In addition, the simultaneous optical imaging of the DAC sample chamber is demonstrated. The ability to conduct simultaneous radial XRD and optical imaging provides the opportunity to characterize plastic strain and deviatoric strain rates in the DAC at intermediate rates, exploring the strength and deformation mechanisms of materials in this regime.

47 OTHER INSTRUMENTATION↗

Trace Element Abundance Measurements on Cosmic Dust Particles

The X-Ray Microprobe on beamline X-26A at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory was used to determine the abundances of elements from Cr through Sr in individual interplanetary dust particles (IDPs) collected from the Earth's stratosphere and the Scanning Transmission X-ray Microscope (STXM) on beamline X-1A at the NSLS was used to determine the carbon abundances and spatial distributions in IDPs. In addition, modeling was performed in an attempt to associate particular types of IDPs with specific types of parent bodies, and thus to infer the chemistry, mineralogy, and structural properties of those parent bodies.

Flynn, George↗

First Protein Crystallization Experiments on The International Space Station: Sweet Success in Space With Thaumatin

We determined the room temperature 1.2 A structure of thaumatin using a crystal grown in the first protein crystallization experiment conducted aboard the International Space Station (ISS). The crystals were grown in the Enhanced Gaseous Nitrogen Dewar (EGN) developed by Alexander McPherson and co-workers. EGN transports frozen solutions contained in tygon tubing in a liquid nitrogen Dewar to ISS where the tubes then thaw. Batch, free interface diffusion (FID), or vapor diffusion crystallization occurs after thawing. EGN was flown to the ISS on STS-106 on September 8, 2000. This was a "risk mitigation" flight that tested EGN performance and the process of conducting experiments on ISS. We focused on how to map a hanging drop crystallization recipe to the EGN FID method. Thaumatin was chosen as the test system. Three series of crystallization recipes were set-up. Each series tested different volume ratios of protein-rich solution to precipitant-rich solution. The series differed from each other by fixing either the protein concentration or the amount of protein in the solutions. Upon return of the samples to Earth on October 24 by STS-92, bubbles that spanned the diameter of the tubing were observed in all tubes. Such bubbles interrupt liquid-liquid diffusion and force vapor diffusion equilibration to occur instead. Nonetheless, crystals grew in 9 of 30 tubes. Many large crystals were grown, the largest being 2.0 x 1.1 x 1.0 cubic mm. The largest crystal was used to collect data at room temperature on beamline 7-1 of the Stanford Synchrotron Radiation Source to a maximum resolution of 1.2 A. The structure was refined anisotropically using SHELX with a data to parameter ratio of 4.5 to give an R(sub factor) of 15.8% (R(sub free) = 18.2%) for ail reflections without generated hydrogens. This refinement is proceeding. Comparisons of this 1.2 A microgravity structure to previous reports of the thaumatin structure at 1.75 A and to ground control crystals will be presented.

Kundrot, Craig E.↗

An Online Dynamic Amplitude-Correcting Gradient Estimation Technique to Align X-ray Focusing Optics

High-brightness X-ray pulses, as generated at synchrotrons and X-ray free electron lasers (XFELs), are used in a variety of scientific experiments. At these facilities, measurements often require optical equipment, e.g Compound Refractive Lenses (CRLs) to be precisely aligned and focused. The lateral alignment of CRLs to a beamline requires precise positioning along four axes: two translational, and the two rotational. At a synchrotron, alignment is often accomplished manually. However, XFEL beamlines present a beam brightness that fluctuates stochastically, making manual alignment a time-consuming endeavor. Automation using simplex or classic stochastic descent often fails, given the errant gradient estimates. Herein we present a dynamic-amplitude correction to the usual gradient based on the combination of a generalized finite difference stencil and a time-dependent sampling pattern. Intensity is recorded periodically, then used to normalize numerical derivatives against fluctuations. Error expectation is analyzed, and efficacy is demonstrated on classic benchmarks. We provide a proof of concept by laterally aligning optics on a simulated XFEL beamline using data recorded at both synchrotron and XFEL facilities.

97 MATHEMATICS AND COMPUTING↗

The Inner Shell Spectroscopy beamline at NSLS-II: a facility for in situ and operando X-ray absorption spectroscopy for materials research

The Inner Shell Spectroscopy (ISS) beamline on the 8-ID station at the National Synchrotron Light Source II (NSLS-II), Upton, NY, USA, is a high-throughput X-ray absorption spectroscopy beamline designed for in situ, operando, and time-resolved material characterization using high monochromatic flux and scanning speed. This contribution discusses the technical specifications of the beamline in terms of optics, heat load management, monochromator motion control, and data acquisition and processing. Results of the beamline tests demonstrating the quality of the data obtainable on the instrument, possible energy scanning speeds, as well as long-term beamline stability are shown. The ability to directly control the monochromator trajectory to define the acquisition time for each spectral region is highlighted. Examples of studies performed on the beamline are presented. The paper is concluded with a brief outlook for future developments.

36 MATERIALS SCIENCE↗

6000 lines/mm blazed grating for a high-resolution x-ray spectrometer

We have designed and fabricated a high groove density blazed grating for a Resonant Inelastic X-ray Scattering spectrometer for the new Qerlin beamline at the Advanced Light Source (ALS) synchrotron facility. The gratings were fabricated using a set of nanofabrication techniques including e-beam lithography, nanoimprint, plasma etch, and anisotropic wet etching. Two gratings with groove density of 6000 lines/mm and 3000 lines/mm and optimized for operation in the 1st and 2nd negative diffraction order respectively were fabricated and tested. We report on fabrication details and characterization of the gratings at beamline 6.3.2 of the ALS.

36 MATERIALS SCIENCE↗