Search NASA⌕ Search

SEARCH · Search NASA

Results for “targeted quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Adjustments and Uncertainty Quantification for SLS Aerodynamic Sectional Loads

This paper presents a method for adjusting sectional loads to match target values for integrated force and moment coefficients. In a typical application, the sectional load profile for one flight condition is calculated from Computational Fluid Dynamics (CFD) while the integrated forces and moments are measured in a wind tunnel experiment. These two methods do not generally result in identical predictions, and this leads to an inherent inconsistency between different data products. This paper aims to provide a procedure to remove that inconsistency. A sectional load profile for a launch vehicle splits the rocket into slices along its length and calculates the aerodynamic loading on each slice, which leads to a one-dimensional aerodynamic load profile that is used for structural analysis. Adjusting sectional loads, also known as line loads, is a nontrivial matter due to several consistency constraints. For example, the adjusted sectional normal force profile must be consistent with both the integrated normal force and pitching moment. To avoid such inconsistency issues, this paper presents a method using a Proper Orthogonal Decomposition (POD) to generate basis functions to adjust the sectional load profiles. As a corollary, this correction method enables the creation of an uncertainty quantification for sectional loads that is consistent with the dispersed integrated force and moment database and its uncertainty quantification. Several extensions to this technique, such as applying the method to the surface pressures, are considered.

Quantification↗

Rapidly Assessing the Quality of Targeted Proteomics Experiments through Monitoring Stable-Isotope Labeled Standards

Selected reaction monitoring (SRM), also known as multiple reaction monitoring (MRM), is a data acquisition technique used in targeted analysis of molecules, including targeted proteomic studies. It exploits the unique capability of triple-quadrupole (QQQ) mass spectrometers to monitor the predefined precursor and fragment ion pairs of specific molecules of interest throughout a liquid chromatography (LC) elution profile. Compared to shotgun proteomics, targeted proteomics using SRM has high selectivity, high sensitivity, and a wide linear dynamic range,(1-3) which makes it especially useful in the accurate and reproducible quantification of low-abundance proteins in highly complex biological samples. SRM has been widely used in the fields of biomarker discovery,(4-7) analysis of protein post-translational modifications(8) and characterization of biological protein networks.(4,9) In the recent years, multiple technical advances have greatly improved the throughput of SRM analyses, allowing for the quantification of hundreds of peptides in a single analysis.(6,7,10) For example, a single 800-plex SRM assay (e.g., 400 unlabeled and heavy-labeled peptide pairs and 2400 transitions with retention time scheduling) using ultrahigh-performance liquid chromatography (UHPLC) has been developed to quantify proteins in plasma.(11) Advanced labeling techniques utilizing in vitro proteome-assisted MRM for protein absolute quantification (iMPAQT) demonstrated the capability of SRM in genome-wide protein quantification of over 18?000 human proteins.(12) Moreover, the scan speed of QQQ instrumentation has been greatly improved in recent releases of commercial instrumentation. The newly developed TSQ Altis (released in 2017) can scan more than 600 transitions per second, which is 6 times more than a traditional QQQ scan speed of 100 transitions per second. The breadth of measurement enabled by these technological improvements to QQQ mass spectrometry has increased the feasibility and popularity of large scale targeted proteomics studies,(13) a major application of which will be in clinical studies in which up to hundreds of protein candidates need to be quantified in hundreds of clinical specimens.(14) Quantitative accuracy is a primary motivating factor for utilizing a targeted proteomics protocol. The precise and reproducible absolute quantification produced by SRM assays is essential to many clinical and laboratory experiments.(15,16) Because the abundance of an endogenous peptide is calculated from the measurement of the spiked-in reference standard, it is essential to assess the data quality of these references.(17) In early applications of targeted proteomics, when instrument speed greatly limited the number of transitions that could be monitored, much of this quality assessment was done manually. However, recent improvements in instrument performance and experimental design have enabled a dramatic increase in the number of target peptides and associated SRM transitions, which makes manual quality assessment an untenable and laborious task. A variety of computational tools assist in SRM experiment design and data analysis. The first task in creating an SRM experiment is the choice of proteins and representative peptides to monitor. Achieving a reliable protein abundance requires appropriately choosing peptides that have a strong signal and are free from interferences in the biological matrix. Numerous computational tools exist to facilitate assay design by identifying peptides and refining SRM transitions.(18-21) To help share these assays and eliminate time spent designing the same transitions at multiple institutions, community portals have begun to host well-designed and vetted assays.(22-24) Analyzing the experimental data requires significant computational effort to align files across replicates and experimental conditions, pick peaks and produce quantitative values, normalize data and perform statistical tests, etc.(25-27)

Gibbons, Bryson C.↗

Bayesian inference of nuclear-matter density from proton scattering

Background: Proton elastic scattering at intermediate energy is widely employed as a tool for determining the matter radius of atomic nuclei. Here, the sensitivity of the approach relies on high-resolution measurements at small scattering angles and low-momentum transfer. Under these conditions, the Glauber multiple scattering theory accurately describes the proton-nucleus elastic cross section. Purpose: Investigate the sensitivity of the Glauber multiple scattering theory to uncertainties associated with input parameters such as the nuclear-matter density distribution and nucleon-nucleon data. Method: A joint Bayesian inference was performed using 12 angular distributions of elastic scattering at different energies on 58 Ni, 90 Zr, and 208 Pb targets. A Metropolis-Hastings algorithm was implemented to make an uncertainty quantification analysis for the input parameters used in the Glauber multiple scattering theory. Results: The experimental cross sections were fitted simultaneously using a joint Bayesian inference approach. Posterior probability density distributions of 42 input parameters were obtained from the analysis. A moderate correlation between the nuclear density parameters and the nucleon-nucleon cross sections was found. This correlation impacts the extraction of the nuclear-matter radius. Conclusions: The present analysis provided a consistent method for extracting the nuclear-matter density distribution of 58 Ni, 90 Zr, and 208 Pb from data across different incident energies. Due to the correlation of the nucleon-nucleon cross sections with the other input parameters, a constrained Bayesian inference using free nucleon-nucleon cross section data was performed. The nuclear-matter radii obtained from the analysis are in good agreement with multiple results reported in the literature.

190 ≤ A ≤ 219↗

First Ever Polymer Flood Field Pilot To Enhance The Recovery Of Heavy Oils On Alaska’s North Slope - Pushing Ahead One Year Later

In June 2018 the team embarked on an ambitious project to address the slow development pace of Alaska’s 20+ billion barrels heavy oil resource via the first ever polymer flood pilot. Following the successful commencement of the pilot in August 2018, the field demonstration, supporting laboratory experiments and numerical simulation have steadily progressed. A significant amount of valuable data and lessons learned have been collected, and are reported in this paper. The ongoing pilot and the research activities is making headway toward the primary objective of validating the use of polymer flooding for extracting heavy oil in Alaska’s challenging environment. The pilot is conducted in two pre-existing pairs of horizontal injectors and producers in an isolated fault block of the Schrader Bluff heavy oil reservoir at the Milne Point Field. A customized polymer blending and pumping unit injects HPAM polymer at a concentration of 1,750 ppm to achieve a target viscosity of 45 cP. Supporting coreflood laboratory experiments have focused on quantification of polymer retention in the rock, and effect of injection water salinity, polymer, and their combinations on oil recovery. The injection and production response of the pilot flood pattern is utilized to develop a history matched reservoir simulation model for forecasting oil recovery beyond the pilot. Finally, specially designed laboratory experiments address anticipated operating concerns regarding post-polymer breakthrough such as oil-water separation efficiency and polymer induced fouling of heater tubes. Polymer has been injected continuously since startup except for two short equipment modification shutdowns, and more recently a prolonged disruption due to polymer hydration issues at the J-pad field site. Cumulatively, over 600,000 lbs. of polymer has been injected, corresponding to ~7%PV. The two producers show significant decrease in the water cut, gradually increasing oil rate, and no polymer breakthrough. Two main observations from the coreflood are a significant uncertainty in polymer retention values, and positive oil recovery response to low salinity water (2,600 mg/liter TDS). The heterogeneity in the flood pattern presents some challenges in obtaining a robust history matched simulation model. Experimental results on produced fluids treatment indicate the formation of a dense polymer deposit, at certain conditions, on heating tubes that can negatively impact the heat transfer efficiency. The scientific knowledge, including the lessons learned during unanticipated shutdowns, quality control, logistics and field data that is being acquired from this effort has referential value for other planned EOR projects. Finally, by all indications, the polymer field pilot is steadily progressing toward achieving the ultimate goal of unlocking the massive heavy oil resources on Alaska North Slope (ANS).

Dandekar, Abhijit↗

TRUST Sensors in Environments: Fiber Optic Displacement (SE-FOD) Report, Release FY24

The objective of the Delivery Environments (DE) Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is to quantify and help increase confidence in specific areas of computational and experimental capabilities that are applicable to the development, on-target assessment, and qualification of current and future delivery environments. More complete quantification of confidence in experimental and computational capabilities and the sufficient increase of confidence in those capabilities is critical to improving weapons engineering design, qualification, and assessment efforts that are critical to the current and future stockpile. This work uses and provides feedback on analysis tools and experimental results databases for efficient and responsive engineering which are currently under development. Under the TRUST work package, there are five testbeds and their associated engineering analysis baseline models (EABMs): 1. Contact Thermal Conductivity (CTC), 2. Nonlinear Dynamics (ND), 3. Sensors in Environments: Accelerometers (SE-A), 4. Sensors in Environments: Fiber Optic Displacement Gauges (SE-FOD), and 5. Sensors in Environments: Thermocouples (SE-TC). The TRUST project uses single-feature testbeds to quantify uncertainties in specific models and experiments and to identify capability development needs that can help to reduce these uncertainties. Each testbed is designed, configured, and tested in collaboration with groups with design and experimental capability: E-14 and MPA-CINT. The complementary simulations are conducted using W-13 analysis tools and stored in model repositories with plans for incremental progress toward EABM requirements. W-13 extends and exercises the testbed simulations in collaboration with experimentalists for uncertainty quantification of current and future materials, geometries, and environments. Additionally, TRUST is intended to provide engineers in W-13 and E-14 with experience in both numerical simulations and experimental methods through cross-discipline collaborations. Following the introduction to the TRUST project, the remainder of this report focuses on experimental, modeling and simulation, and analysis efforts conducted in FY24 relevant to the TRUST Sensors in Environments: Fiber Optic Displacement (SE-FOD) testbed.

42 ENGINEERING↗

TRUST Sensors in Environments: Thermocouples (SE-TC) Report Release FY24

The objective of the Delivery Environments (DE) Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is to quantify and help increase confidence in specific areas of computational and experimental capabilities that are applicable to the development, on-target assessment, and qualification of current and future delivery environments. More complete quantification of confidence in experimental and computational capabilities and the sufficient increase of confidence in those capabilities is critical to improving weapons engineering design, qualification, and assessment efforts that are critical to the current and future stockpile. This work uses and provides feedback on analysis tools and experimental results databases for efficient and responsive engineering which are currently under development.

42 ENGINEERING↗

TRUST Sensors in Environments: Fiber Optic Displacement (SE-FOD)

The objective of the Delivery Environments (DE) Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is to quantify and help increase confidence in specific areas of computational and experimental capabilities that are applicable to the development, on-target assessment, and qualification of current and future delivery environments. More complete quantification of confidence in experimental and computational capabilities and the sufficient increase of confidence in those capabilities is critical to improving weapons engineering design, qualification, and assessment efforts that are critical to the current and future stockpile. Under the TRUST work package, engineers use and provide feedback on analysis tools and experimental results and create databases for efficient and responsive engineering which are currently under development.

42 ENGINEERING↗

Field Deployment of a Portable Optical Spectrometer for Methane Fugitive Emissions Monitoring on Oil and Gas Well Pads

We present field deployment results of a portable optical absorption spectrometer for localization and quantification of fugitive methane (CH 4 ) emissions. Our near-infrared sensor targets the 2$ν_3$ R(4) CH 4 transition at 6057.1 cm −1 (1651 nm) via line-scanned tunable diode-laser absorption spectroscopy (TDLAS), with Allan deviation analysis yielding a normalized 2.0 ppmv∙Hz −1/2 sensitivity (4.5 × 10 −6 Hz −1/2 noise-equivalent absorption) over 5 cm open-path length. Controlled CH 4 leak experiments are performed at the METEC CSU engineering facility, where concurrent deployment of our TDLAS and a customized volatile organic compound (VOC) sensor demonstrates good linear correlation (R 2 = 0.74) over high-flow (>60 SCFH) CH 4 releases spanning 4.4 h. In conjunction with simultaneous wind velocity measurements, the leak angle-of-arrival (AOA) is ascertained via correlation of CH 4 concentration and wind angle, demonstrating the efficacy of single-sensor line-of-sight (LOS) determination of leak sources. Finally, source magnitude estimation based on a Gaussian plume model is demonstrated, with good correspondence (R 2 = 0.74) between calculated and measured release rates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous Proteomic Discovery and Targeted Monitoring using Liquid Chromatography, Ion Mobility Spectrometry, and Mass Spectrometry

Current proteomics approaches are comprised of both broad discovery measurements as well as more quantitative targeted measurements. These two different measurement types are used to initially identify potentially important proteins (e.g., candidate biomarkers) and then enable improved quantification for a limited number of selected proteins. However, both approaches suffer from limitations, particularly the lower sensitivity, accuracy, and quantitation precision for discovery approaches compared to targeted approaches, and the limited proteome coverage provided by targeted approaches. Herein, we describe a new proteomics approach that allows both discovery and targeted monitoring (DTM) in a single analysis using liquid chromatography, ion mobility spectrometry and mass spectrometry (LC-IMS-MS). In DTM, heavy labeled peptides for target ions are spiked into tryptic digests and both the labeled and unlabeled peptides are broadly detected using LC-IMS-MS instrumentation, allowing the benefits of discovery and targeted approaches. To understand the possible improvement of the DTM approach, it was compared to LC-MS broad measurements using an accurate mass and time tag database and selected reaction monitoring (SRM) targeted measurements. The DTM results yielded greater peptide/protein coverage and a significant improvement in the detection of lower abundance species compared to LC-MS discovery measurements. DTM was also observed to have similar detection limits as SRM for the targeted measurements indicating its potential for combining the discovery and targeted approaches.

Environmental Molecular Sciences Laboratory↗

TU-A-12A-06: Intra-Observer Variability in Delineation of Target Volumes in Breast Radiotherapy and Its Effect On Accuracy of Deformation Measurements

Purpose: In breast radiotherapy, the target volume may change during treatment and need adaptation of the treatment plan. This is possible for both tumour bed (TB) and whole breast (WB) target volumes. Delineation of the target (to detect changes) is also subject to uncertainty due to intra- and inter-observer variability. This work measured the uncertainty, due to intraobserver variability, in the quantification of tissue deformation. Methods: Datasets consisting of paired prone and supine CT scans of three patients were used. Significant deformation in target volumes is expected between prone and supine patient positions. The selected cases had 1) no seroma, 2) some seroma, and 3) large seroma. The TB and WB were outlined on each dataset three times by one clinician. Delineation variability was defined as the standard deviations of the distances between observer outlines. For each target volume and each case, tissue deformation between prone and supine delineations was quantified using the Dice similarity coefficient (DSC) and the average surface distance (ASD). The uncertainty in the tissue deformation (due to delineation variability) was quantified by measuring the ranges of DSC and ASD using all combinations of pairs of outlines (9 pairs). Results: For the TB, the range of delineation variability was 0.44-1.16 mm. The deformation, DSC and ASD, (and uncertainty in measurement) of the TB between prone and supine position of the cases were: 1) 0.21 (0.17-0.28) and 12.4 mm (11.8-13 mm); 2) 0.54 (0.51-0.57) and 3.3 mm (3.1-3.5 mm); 3) 0.62 (0.61-0.64) and 4.9 mm (4.6-5.2 mm). WB deformation measurements were subject to less uncertainty due to delineation variability than TB deformation measurements. Conclusion: For the first time, the uncertainty, due to observer variability, in the measurement of the deformation of breast target volumes was investigated. Deformations in these ranges would be difficult to detect. This work was supported in part by Cancer Research-UK under Programme Grant C46/A10588 and in part by the National Institute for Health Research (NIHR) through funding of the biomedical research imaging centre. P. Juneja is supported by the EPSRC Platform Grant EP/H046526/1.

60 APPLIED LIFE SCIENCES↗

Calcium-organic matter fouling in nanofiltration: Synchrotron-based X-ray fluorescence and absorption near-edge structure spectroscopy for speciation

Calcium (Ca)-enhanced organic matter (OM) fouling of nanofiltration (NF) membranes leads to reduced flux during desalination and requires frequent cleaning. Fouling mechanisms are not fully understood, which limits the development of targeted fouling control methods. This study employed synchrotron-based X-ray fluorescence (XRF) and X-ray absorption near-edge structure (XANES) spectroscopy to quantify the spatial distribution and mass of Ca deposition as well as changes in the Ca coordination environment characteristic of specific fouling mechanisms, respectively. Bench-scale filtration experiments were performed using feed solutions containing Ca and ten different types of organic matter (OM), as well as the common scalants, calcium carbonate (CaCO 3 ) and calcium sulfate (CaSO 4 ). Osmotic backwash (OB) was performed at regular intervals for fouling control. Ca-OM aggregation resulted in greater flux decline and lower flux recovery during OB than Ca conditioning of membranes followed by filtration of feed solution with OM. Linear combination fitting (LCF) of XANES absorption spectra from fouled membranes indicated that Ca-OM aggregation preferentially occurred for OM types that exhibited both high carboxylic group and negative charge density. Consequently, these OM types exhibited greater deposition of Ca and TOC on the membrane surface when compared to other OM types. For the coexistence of scalants and OM, Ca speciation within the fouling layer was characteristic of both Ca bound to the membrane (i.e. potential bridging, charge screening) as well as Ca-OM aggregation and deposition mechanisms, while a range of crystal polymorphs were observed to occur simultaneously. XRF and XANES represent powerful tools for the elucidation of NF fouling mechanisms by quantification of Ca deposition as well as Ca speciation. Fouling control methods should target OM types with high carboxyl group density and negative charge to neutralize or eliminate interactions with Ca.

42 ENGINEERING↗

DAiSES: Dynamic Adaptivity in Support of Extreme Scale Department of Energy Project No. ER25622 Prime Contract No. DE-FG02-04ER25622 Final Report for September 15, 2004-September 14, 2008

The DAiSES project [Te04] was focused on enabling conventional operating systems, in particular, those running on extreme scale systems, to dynamically customize system resource management in order to offer applications the best possible environment in which to execute. Such dynamic adaptation allows operating systems to modify the execution environment in response to changes in workload behavior and system state. The main challenges of this project included determination of what operating system (OS) algorithms, policies, and parameters should be adapted, when to adapt them, and how to adapt them. We addressed these challenges by using a combination of static analysis and runtime monitoring and adaptation to identify a priori profitable targets of adaptation and effective heuristics that can be used to dynamically trigger adaptation. Dynamic monitoring and adaptation of the OS was provided by either kernel modifications or the use of KernInst and Kperfmon [Wm04]. Since Linux, an open source OS, was our target OS, patches submitted by kernel developers and researchers often facilitated kernel modifications. KernInst operates on unmodified commodity operating systems, i.e., Solaris and Linux; it is fine-grained, thus, there were few constraints on how the underlying OS can be modified. Dynamically adaptive functionality of operating systems, both in terms of policies and parameters, is intended to deliver the maximum attainable performance of a computational environment and meet, as best as possible, the needs of high-performance applications running on extreme scale systems, while meeting system constraints. DAiSES research endeavored to reach this goal by developing methodologies for dynamic adaptation of OS parameters and policies to manage stateful and stateless resources [Te06] and pursuing the following two objectives: (1) Development of mechanisms to dynamically sense, analyze, and adjust common performance metrics, fluctuating workload situations, and overall system environment conditions. (2) Demonstration, via Linux prototypes and experiments, of dynamic self-tuning and self-provisioning in HPC environments. From a high level, the DAiSES methodology, depicted in Figure 1, includes characterization of application resource usage patterns, identification of candidate (profitable) adaptation targets, determination of feasible adaptation ranges, definition of heuristics to trigger adaptation, design and implementation of OS monitoring, triggering, and adaptation code, and quantification of performance gains.

97 MATHEMATICS AND COMPUTING↗

A microCT-based platform to quantify drug targeting

Abstract Background Heterotopic ossification (HO) is a frequent and debilitating complication of traumatic musculoskeletal injuries and orthopedic procedures. Prophylactic dosing of botulinum toxin type A (BTxA) holds potential as a novel treatment option if accurately distributed throughout soft-tissue volumes where protection is clinically desired. We developed a high-resolution, microcomputed tomography (microCT)-based imaging strategy to assess drug distribution and validated this platform by quantifying distribution achieved via a prototype delivery system versus a single-bolus injection. Methods We injected an iodine-containing contrast agent (iodixanol 320 mg I/mL) into dissected rabbit musculature followed by microCT imaging and analysis. To contrast the performance of distributed versus bolus injections, a three-dimensional (3D) 64-cm 3 -printed soft-tissue holder was developed. A centered 2-cm 3 volume of interest (VOI) was targeted with a single-bolus injection or an equal volume distributed injection delivered via a 3D-printed prototype. VOI drug coverage was quantified as a percentage of the VOI volume that was < 1.0 mm from the injected fluid. Results The microCT-based approach enabled high-resolution quantification of injection distribution within soft tissue. The distributed dosing prototype provided significantly greater tissue coverage of the targeted VOI (72 ± 3%, mean ± standard deviation) when compared to an equal volume bolus dose (43 ± 5%, p = 0.031) while also enhancing the precision of injection targeting. Conclusions A microCT-based imaging technique precisely quantifies drug distribution within a soft-tissue VOI, providing a path to overcome a barrier for clinical translation of prophylactic inhibition of HO by BTxA. Relevance statement This platform will facilitate rapid optimization of injection parameters for clinical devices used to effectively and safely inhibit the formation of heterotopic ossification. Key points • MicroCT provides high-resolution quantification of soft-tissue drug distribution. • Distributed dosing is required to maximize soft-tissue drug coverage. • Imaging platform will enable rapid screening of 3D-printed drug distribution prototypes. Graphical Abstract

Ausk, Brandon J. (ORCID:0000000335338303)↗

Proteomic Identification and Quantification of S-glutathionylation in Mouse Macrophages Using Resin-Assisted Enrichment and Isobaric Labeling

Protein S-glutathionylation (SSG) is an important regulatory posttranslational modification of protein cysteine (Cys) thiol redox switches, yet the role of specific cysteine residues as targets of modification is poorly understood. We report a novel quantitative mass spectrometry (MS)-based proteomic method for site-specific identification and quantification of S-glutathionylation across different conditions. Briefly, this approach consists of initial blocking of free thiols by alkylation, selective reduction of glutathionylated thiols and enrichment using thiol affinity resins, followed by on-resin tryptic digestion and isobaric labeling with iTRAQ (isobaric tags for relative and absolute quantitation) for MS-based identification and quantification. The overall approach was validated by application to RAW 264.7 mouse macrophages treated with different doses of diamide to induce glutathionylation. A total of 1071 Cys-sites from 690 proteins were identified in response to diamide treatment, with ~90% of the sites displaying >2-fold increases in SSG-modification compared to controls.. This approach was extended to identify potential SSG modified Cys-sites in response to H2O2, an endogenous oxidant produced by activated macrophages and many pathophysiological stimuli. The results revealed 364 Cys-sites from 265 proteins that were sensitive to S-glutathionylation in response to H2O2 treatment. These proteins covered a range of molecular types and molecular functions with free radical scavenging, and cell death and survival included as the most significantly enriched functional categories. Overall the results demonstrate that our approach is effective for site-specific identification and quantification of S-glutathionylated proteins. The analytical strategy also provides a unique approach to determining the major pathways and cell processes most susceptible to glutathionylation at a proteome-wide scale.

Environmental Molecular Sciences Laboratory↗

A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers

Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles after incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, ‘HTS-DCYA assay’, is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens™ were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first time. - Highlights: • A novel fluorescence-based method to detect electrophilic sensitizers is proposed. • A model fluorescent thiol was used to directly quantify the reaction products. • A discussion of the reaction workflow and critical parameters is presented. • The method could provide a useful tool to complement existing chemical assays.

60 APPLIED LIFE SCIENCES↗

Sparsifying priors for Bayesian uncertainty quantification in model discovery

We propose a probabilistic model discovery method for identifying ordinary differential equations governing the dynamics of observed multivariate data. Our method is based on the sparse identification of nonlinear dynamics (SINDy) framework, where models are expressed as sparse linear combinations of pre-specified candidate functions. Promoting parsimony through sparsity leads to interpretable models that generalize to unknown data. Instead of targeting point estimates of the SINDy coefficients, we estimate these coefficients via sparse Bayesian inference. The resulting method, uncertainty quantification SINDy (UQ-SINDy), quantifies not only the uncertainty in the values of the SINDy coefficients due to observation errors and limited data, but also the probability of inclusion of each candidate function in the linear combination. UQ-SINDy promotes robustness against observation noise and limited data, interpretability (in terms of model selection and inclusion probabilities) and generalization capacity for out-of-sample forecast. Sparse inference for UQ-SINDy employs Markov chain Monte Carlo, and we explore two sparsifying priors: the spike and slab prior, and the regularized horseshoe prior. UQ-SINDy is shown to discover accurate models in the presence of noise and with orders-of-magnitude less data than current model discovery methods, thus providing a transformative method for real-world applications which have limited data.

97 MATHEMATICS AND COMPUTING↗

Neural Density Estimation and Uncertainty Quantification for ChemCam Spectra [Slides]

The ChemCam instrument of Curiosity uses laser-induced breakdown spectroscopy (LIBS). It fires a laser at target and vaporizes rock surfaces, creating a plasma. Three spectrographs divide the plasma light into wavelengths for chemical analysis: ultraviolet, violet, and visible near-infrared. Regression methods (SVR, PCR, CNN) have been employed for calibration (prediction of the elemental composition of samples); however, labeled ChemCam samples are limited. Here, we focus on unsupervised learning and employ generative models from ChemCam analysis. Further, we use labels (supervised) in combination to the generative model to compute uncertainties related to predictions. We report generative modeling can be successfully applied to model real-world data. Normalizing flow models can be efficiently constructed on latent spaces for fast downstream inference. Unsupervised and supervised learning can be combined to form an uncertainty quantification framework.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Harmonizing tau positron emission tomography in Alzheimer's disease: The CenTauR scale and the joint propagation model

Abstract INTRODUCTION Tau‐positron emission tomography (PET) outcome data of patients with Alzheimer's disease (AD) cannot currently be meaningfully compared or combined when different tracers are used due to differences in tracer properties, instrumentation, and methods of analysis. METHODS Using head‐to‐head data from five cohorts with tau PET radiotracers designed to target tau deposition in AD, we tested a joint propagation model (JPM) to harmonize quantification (units termed “CenTauR” [CTR]). JPM is a statistical model that simultaneously models the relationships between head‐to‐head and anchor point data. JPM was compared to a linear regression approach analogous to the one used in the amyloid PET Centiloid scale. RESULTS A strong linear relationship was observed between CTR values across brain regions. Using the JPM approach, CTR estimates were similar to, but more accurate than, those derived using the linear regression approach. DISCUSSION Preliminary findings using the JPM support the development and adoption of a universal scale for tau‐PET quantification. Highlights Tested a novel joint propagation model (JPM) to harmonize quantification of tau PET. Units of common scale are termed “CenTauRs”. Tested a Centiloid‐like linear regression approach. Using five cohorts with head‐to‐head tau PET, JPM outperformed linearregressionbased approach. Strong linear relationship was observed between CenTauRs values across brain regions.

Neurosciences & Neurology↗