Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Accelerated test techniques for micro-circuits: Evaluation of high temperature (473 k - 573 K) accelerated life test techniques as effective microcircuit screening methods

The application of high temperature accelerated test techniques was shown to be an effective method of microcircuit defect screening. Comprehensive microcircuit evaluations and a series of high temperature (473 K to 573 K) life tests demonstrated that a freak or early failure population of surface contaminated devices could be completely screened in thirty two hours of test at an ambient temperature of 523 K. Equivalent screening at 398 K, as prescribed by current Military and NASA specifications, would have required in excess of 1,500 hours of test. All testing was accomplished with a Texas Instruments' 54L10, low power triple-3 input NAND gate manufactured with a titanium- tungsten (Ti-W), Gold (Au) metallization system. A number of design and/or manufacturing anomalies were also noted with the Ti-W, Au metallization system. Further study of the exact nature and cause(s) of these anomalies is recommended prior to the use of microcircuits with Ti-W, Au metallization in long life/high reliability applications. Photomicrographs of tested circuits are included.

Johnson, G. M.↗

Simulation verification techniques study: Simulation performance validation techniques document

Techniques and support software for the efficient performance of simulation validation are discussed. Overall validation software structure, the performance of validation at various levels of simulation integration, guidelines for check case formulation, methods for real time acquisition and formatting of data from an all up operational simulator, and methods and criteria for comparison and evaluation of simulation data are included. Vehicle subsystems modules, module integration, special test requirements, and reference data formats are also described.

Duncan, L. M.↗

Simulation verification techniques study. Subsystem simulation validation techniques

Techniques for validation of software modules which simulate spacecraft onboard systems are discussed. An overview of the simulation software hierarchy for a shuttle mission simulator is provided. A set of guidelines for the identification of subsystem/module performance parameters and critical performance parameters are presented. Various sources of reference data to serve as standards of performance for simulation validation are identified. Environment, crew station, vehicle configuration, and vehicle dynamics simulation software are briefly discussed from the point of view of their interfaces with subsystem simulation modules. A detailed presentation of results in the area of vehicle subsystems simulation modules is included. A list of references, conclusions and recommendations are also given.

Duncan, L. M.↗

Ride quality research techniques: Section on scaling techniques

Scaling techniques appropriate for the measurement of ride quality subjective responses are evaluated. The major focal points of interest are summarized in succeeding paragraphs as follow: (1) scope of scaling, (2) goal of scaling, (3) category scales; including polarity, scalar points, and whether the scale is discrete or continuous in nature, (4) need and use of adjectives and/or adverbs, (5) role and use of magnitude estimation, (6) multiple response measures; and (7) related topics.

Source record↗

Modulation/demodulation techniques for satellite communications. Part 2: Advanced techniques. The linear channel

A theory is presented for deducing and predicting the performance of transmitter/receivers for bandwidth efficient modulations suitable for use on the linear satellite channel. The underlying principle used is the development of receiver structures based on the maximum-likelihood decision rule. The application of the performance prediction tools, e.g., channel cutoff rate and bit error probability transfer function bounds to these modulation/demodulation techniques.

Omura, J. K.↗

Modulation/demodulation techniques for satellite communications. Part 3: Advanced techniques. The nonlinear channel

A theory for deducing and predicting the performance of transmitter/receivers for bandwidth efficient modulations suitable for use on the nonlinear satellite channel is presented. The underlying principle used throughout is the development of receiver structures based on the maximum likelihood decision rule and aproximations to it. The bit error probability transfer function bounds developed in great detail in Part 4 is applied to these modulation/demodulation techniques. The effects of the various degrees of receiver mismatch are considered both theoretically and by numerous illustrative examples.

Omura, J. K.↗

Protein solubilities determined by a rapid technique and modification of that technique to a micro-method

A simple, rapid method for determination of protein solubilities has been developed which is based upon maximization of the free solution volume to be brought into equilibrium. The tetragonal lysozome solubility diagram has been determined from pH 4.0 to 5.2 (0.1 M sodium acetate), 2-7 percent NaCl, 3-25 C, and portions of the orthorhombic solubility diagram using this technique. Both tetragonal and orthorhombic solubilities were found to increase smoothly with decreasing salt concentration and increasing temperature; no retrograde solubilities were observed. Using column volumes of 75, 300, and 900 microliters, identical tetragonal lysozyme solubility diagrams were obtained. Chymotrypsinogen solubilities have also been determined using this apparatus, being retrograde over the temperature range tested. It is noted that the primary limiting factor in reducing the crystalline volume is the minimum solution sample size needed to accurately quantitate the protein.

Cacioppo, Elizabeth↗

Comparison of a two-dimensional adaptive-wall technique with analytical wall interference correction techniques

A two dimensional airfoil model was tested in the adaptive wall test section of the NASA Langley 0.3 meter Transonic Cryogenic Tunnel (TCT) and in the ventilated test section of the National Aeronautical Establishment Two Dimensional High Reynold Number Facility (HRNF). The primary goal of the tests was to compare different techniques (adaptive test section walls and classical, analytical corrections) to account for wall interference. Tests were conducted over a Mach number range from 0.3 to 0.8 at chord Reynolds numbers of 10 x 10(exp 6), 15 x 10(exp 6), and 20 x 10(exp 6). The angle of attack was varied from about 12 degrees up to stall. Movement of the top and bottom test section walls was used to account for the wall interference in the HRNF tests. The test results are in good agreement.

Mineck, Raymond E.↗

Comparison of Commercial Electromagnetic Interface Test Techniques to NASA Electromagnetic Interference Test Techniques

This report documents the development of analytical techniques required for interpreting and comparing space systems electromagnetic interference test data with commercial electromagnetic interference test data using NASA Specification SSP 30237A "Space Systems Electromagnetic Emission and Susceptibility Requirements for Electromagnetic Compatibility." The PSpice computer simulation results and the laboratory measurements for the test setups under study compare well. The study results, however, indicate that the transfer function required to translate test results of one setup to another is highly dependent on cables and their actual layout in the test setup. Since cables are equipment specific and are not specified in the test standards, developing a transfer function that would cover all cable types (random, twisted, or coaxial), sizes (gauge number and length), and layouts (distance from the ground plane) is not practical.

Smith, V.↗

V and V techniques for FPGA-based I and C systems - How do they compare with techniques for microprocessors? - 355

We compare verification and validation (V and V) techniques for FPGA and microprocessor-based instrumentation and control (I and C) systems from the point of view of standards compliance, an approach based on behavioural properties, and the analysis of vulnerabilities. We found that the non-technology-specific elements of the standards considered are very similar. Differences are more marked when considering behavioural properties and vulnerabilities: the amount of effort required and confidence level obtained depend on a number of properties of the particular design under verification. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures

Natural organic matter (NOM) is composed of a highly complex mixture of thousands of organic compounds which, historically, proved difficult to characterize. However, to understand the thermodynamic and kinetic controls on greenhouse gas (carbon dioxide [CO 2 ] and methane [CH 4 ]) production resulting from the decomposition of NOM, a molecular-level characterization coupled with microbial proteome analyses is necessary. Further, climate and environmental changes are expected to perturb natural ecosystems, potentially upsetting complex interactions that influence both the supply of organic matter substrates and the microorganisms performing the transformations. A detailed molecular characterization of the organic matter, microbial proteomics, and the pathways and transformations by which organic matter is decomposed will be necessary to predict the direction and magnitude of the effects of environmental changes. This article describes a methodological throughput for comprehensive metabolite characterization in a single sample by direct injection Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS), gas chromatography mass spectrometry (GC-MS), nuclear magnetic resonance (NMR) spectroscopy, liquid chromatography mass spectrometry (LC-MS), and proteomics analysis. Furthermore, this approach results in a fully-paired dataset which improves statistical confidence for inferring pathways of organic matter decomposition, the resulting CO 2 and CH 4 production rates, and their responses to environmental perturbation. Herein we present results of applying this method to NOM samples collected from peatlands; however, the protocol is applicable to any NOM sample (e.g., peat, forested soils, marine sediments, etc.).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

M-BAND IMAGING OF THE HR 8799 PLANETARY SYSTEM USING AN INNOVATIVE LOCI-BASED BACKGROUND SUBTRACTION TECHNIQUE

Multi-wavelength observations/spectroscopy of exoplanetary atmospheres are the basis of the emerging exciting field of comparative exoplanetology. The HR 8799 planetary system is an ideal laboratory to study our current knowledge gap between massive field brown dwarfs and the cold 5 Gyr old solar system planets. The HR 8799 planets have so far been imaged at J- to L-band, with only upper limits available at M-band. We present here deep high-contrast Keck II adaptive optics M-band observations that show the imaging detection of three of the four currently known HR 8799 planets. Such detections were made possible due to the development of an innovative LOCI-based background subtraction scheme that is three times more efficient than a classical median background subtraction for Keck II AO data, representing a gain in telescope time of up to a factor of nine. These M-band detections extend the broadband photometric coverage out to {approx}5 {mu}m and provide access to the strong CO fundamental absorption band at 4.5 {mu}m. The new M-band photometry shows that the HR 8799 planets are located near the L/T-type dwarf transition, similar to what was found by other studies. We also confirm that the best atmospheric fits are consistent with low surface gravity, dusty, and non-equilibrium CO/CH{sub 4} chemistry models.

79 ASTRONOMY AND ASTROPHYSICS↗

A Comparison of Reduced Order Modeling Techniques Used in Dynamic Substructuring [PowerPoint]

Experimental dynamic substructuring is a means whereby a mathematical model for a substructure can be obtained experimentally and then coupled to a model for the rest of the assembly to predict the response. Recently, various methods have been proposed that use a transmission simulator to overcome sensitivity to measurement errors and to exercise the interface between the substructures; including the Craig-Bampton, Dual Craig-Bampton, and Craig-Mayes methods. This work compares the advantages and disadvantages of these reduced order modeling strategies for two dynamic substructuring problems. The methods are first used on an analytical beam model to validate the methodologies. Then they are used to obtain an experimental model for structure consisting of a cylinder with several components inside connected to the outside case by foam with uncertain properties. This represents an exceedingly difficult structure to model and so experimental substructuring could be an attractive way to obtain a model of the system.

97 MATHEMATICS AND COMPUTING↗

Retrospective neutron spectrum determination of a (30 MeV D, Be) source using the multi-foil activation technique and STAYSL-PNNL [Characterization of neutron spectra from a (30 MeV d, Be) source using the multi-foil activation technique]

Retrospective characterization of a (30 MeV D, Be) neutron source was performed employing multi-foil activation and STAYSL-PNNL. Experimental reaction rates were calculated from gamma spectroscopy measurements of irradiated foils and MCNP provided the guess spectrum. Adjusted spectra were evaluated through activation calculations for a stainless-steel target using FISPACT-II. Adjusted spectra showed limited dependence on the dosimetry reactions and provided minor improvements in activation calculations. Omitting reflected neutrons in the guess spectrum generated poor activation results and the limited number of dosimetry reactions introduced doubt in the adjusted spectra. Furthermore, a dedicated neutron spectrometry experiment and a more detailed simulation is required.

42 ENGINEERING↗