Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Near-field passive sensor for the monitoring of high-temperature oxidative corrosion of metals

This study reports on the development and testing of a passive wireless device designed to track temperature and corrosion behavior in SS304H stainless steel under elevated temperatures. The ANSYS HFSS software was utilized to model and optimize the design of an inductor-capacitor (LC) resonator passive wireless sensors fabricated using platinum designs printed onto an aluminum oxide support operating at frequencies between (50–190 MHz). The optimal LC wireless sensor designs were then fabricated using screen-printing and sintering methods. Here, the sensors were tested by placing the sensor onto polished SS304H flat substrates and heated to 900–1050 °C in air. Wireless acquisition of sensor data during heating, cooling, and isothermal stages was achieved through a Pt loop antenna connected to an RF signal generator and a network analyzer.

20 FOSSIL-FUELED POWER PLANTS↗

Development of Miniaturized High-Temperature Multi-Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings.

20 FOSSIL-FUELED POWER PLANTS↗

Assessing Heterogeneity of Surface Water Temperature Following Stream Restoration and a High-Intensity Fire from Thermal Imagery

Thermal heterogeneity of rivers is essential to support freshwater biodiversity. Salmon behaviorally thermoregulate by moving from patches of warm water to cold water. When implementing river restoration projects, it is essential to monitor changes in temperature and thermal heterogeneity through time to assess the impacts to a river’s thermal regime. Lightweight sensors that record both thermal infrared (TIR) and multispectral data carried via unoccupied aircraft systems (UASs) present an opportunity to monitor temperature variations at high spatial (<0.5 m) and temporal resolution, facilitating the detection of the small patches of varying temperatures salmon require. Here, we present methods to classify and filter visible wetted area, including a novel procedure to measure canopy cover, and extract and correct radiant surface water temperature to evaluate changes in the variability of stream temperature pre- and post-restoration followed by a high-intensity fire in a section of the river corridor of the South Fork McKenzie River, Oregon. We used a simple linear model to correct the TIR data by imaging a water bath where the temperature increased from 9.5 to 33.4 °C. The resulting model reduced the mean absolute error from 1.62 to 0.35 °C. We applied this correction to TIR-measured temperatures of wetted cells classified using NDWI imagery acquired in the field. We found warmer conditions (+2.6 °C) after restoration (p < 0.001) and median absolute deviation for pre-restoration (0.30) to be less than both that of post-restoration (0.85) and post-fire (0.79) orthomosaics. In addition, there was statistically significant evidence to support the hypothesis of shifts in temperature distributions pre- and post-restoration (KS test 2009 vs. 2019, p < 0.001, D = 0.99; KS test 2019 vs. 2021, p < 0.001, D = 0.10). Moreover, we used a Generalized Additive Model (GAM) that included spatial and environmental predictors (i.e., canopy cover calculated from multispectral NDVI and photogrammetrically derived digital elevation model) to model TIR temperature from a transect along the main river channel. This model explained 89% of the deviance, and the predictor variables showed statistical significance. Collectively, our study underscored the potential of a multispectral/TIR sensor to assess thermal heterogeneity in large and complex river systems.

Barker, Matthew I. (ORCID:0000000252864930)↗

Real-time well integrity monitoring in underground gas storage wells using distributed temperature and strain sensing: a field demonstration

Here, this article presents the first successful field demonstration of a combined distributed temperature and strain sensing (DTSS) system installed directly on newly replaced tubing in a 5400-ft-deep operational underground gas storage well. The DTSS system uses a single optical fiber to monitor temperature and strain in real-time, providing a cost-effective solution for long-term well integrity assessment. In this study, the strain–stress correlation of the tubing—representative of material behavior analysis—is investigated as a potential method for monitoring tubing integrity throughout its lifetime. Moreover, the DTSS system’s capability to support both continuous and discrete monitoring is evaluated by comparing future data with historical records, enabling the early detection of issues such as material fatigue, corrosion, or deformation. Overall, the work examines the effectiveness and scalability of the DTSS system for real-time monitoring of well operations and integrity in a newly replaced well.

Distributed Strain Sensing↗

As-run thermal hydraulics analysis of the EPRI-1 Experiment

The EPRI-1 experiment was designed to irradiate various types of reactor pressure vessel steels at a temperature of 288°C (PLN-3934). The specimens were irradiated in an instrumented test train inside a pressurized water loop in the center lobe of the ATR during cycle 157C. Temperature was monitored using thermocouples placed at the top of the test train. Additional temperature indications were obtained by post-irradiation examination of melt wires placed within the test train and spanning the temperature range 239°C to 327°C. The purpose of this analysis is to calculate specimen temperature using measured data on reactor power and as-run calculations of heating rates of the test train. The accuracy of the model is assessed by comparing the measured and calculated in-pile tube inlet to outlet temperature difference, comparing the measured and calculated thermocouple temperatures, and comparing the calculated specimen temperature to the temperature range indicated by the melt wires.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Calcined Polyethyleneimine-Coated Optical Fibers for Distributed pH Monitoring at High Pressures and Temperatures

In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Previous tests using metal oxide-based coatings (TiO2) provided strong responses at elevated temperatures and moderate pressure stability but provided poor differentiation between acidic and alkaline solutions. Building off the pH responsiveness of the TiO2 surface and known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. As the polymer itself is highly water soluble and easily removed by aqueous solutions, the sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1,000 psi) and temperatures (80 °C).

Shumski, Alexander↗

Field evaluation of zone temperature response to control actions in cooling systems of small and medium-sized office buildings

The response of zone temperature to control actions in heating, ventilation, and air conditioning (HVAC) systems, known as zone temperature response, has been a central focus of building control research owing to its crucial role in determining control performance. However, existing studies often overlook the representativeness of the buildings being studied, resulting in unclear generalizations. In addition, those studies tend to focus on a single aspect of the response. Furthermore, this paper provides the first comprehensive characterization of zone temperature response applicable to a clearly defined building sector—small and medium-sized office (SMO) buildings (<5000 m 2 ) in the US. Specifically, two representative SMO buildings, selected based on the US Department of Energy’s commercial prototype buildings, were studied. Field tests were conducted over a 2-month period during summer, and the collected data were analyzed with two key metrics—delay time and nonlinearity index—to quantify zone temperature response, capturing both short- and long-term patterns. Beyond this quantitative characterization, the analysis reveals that the HVAC system type, rather than factors like floor area or zone location, is the primary determinant of the zone temperature response. Drawing on the field test results, we recommend that building control strategies monitor zone temperatures at intervals shorter than 10 minutes, configure controls independently for VAV- and RTU-served zones, and implement nonlinear methods at the zone level—particularly for VAV zones—rather than across the entire building.

Building control↗

Calcined Polyethyleneimine Coated Optical Fibers for Distributed pH Monitoring at High Pressures and Temperatures

In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Building off of earlier TiO2 based pH sensors and the known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. The sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1000 psi) and temperatures (80 °C). A calibration curve with strong differentiation between acidic and alkaline pH was developed for both transmission-based and distributed pH measurements, using fixed wavelength transmission and integrated linear amplitude of backscattered light for distributed measurements.

Shumski, Alexander↗

Distributed sensing of electromagnetic components using optical fiber based methods

An OFDR based fiber-optics sensor for distributed real-time temperature rise monitoring of a transformer in operation has been disclosed. The fiber-optic sensor provides an effective solution to monitoring the physical structures of the transformer core, as well as accurately detecting the non-uniform temperature distribution inside the transformer, and thus provides innovative feedback to the transformer design by minimizing the core losses. Additionally, the method may be responsive to the presence of magnetic and electric fields, as well as responsive to various chemical species. The method allows novel approaches to real-time asset monitoring of power transformers while operational.

Ohodnicki, Paul R.↗

Real-time measurement of parametric influences on the refractive index and length changes in silica optical fibers

In this paper, we present a simple cascaded Fabry-Perot interferometer (FPI) that can be used to measure in real-time the refractive index (RI) and length variation in silica optical fibers caused due to external physical parameters, such as temperature, strain, and radiation. As a proof-of-concept, we experimentally demonstrate real-time monitoring of temperature effects on the RI and length and measure the thermo-optic coefficient (TOC) and thermal expansion coefficient (TEC) by using the cascaded FPI within a temperature range of 21–486°C. The experimental results provide a TEC of 5.53 × 10 −7 /°C and TOC of 4.28 × 10 −6 /°C within the specified temperature range. Such a simple cascaded FPI structure will enable the design of optical sensors to correct for measurement errors by understanding the change in RI and length of optical fiber caused by environment parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive Temperature Sensors for Nuclear Applications

In April 2007, the Department of Energy (DOE) designated the Advanced Test Reactor (ATR) a National Scientific User Facility (NSUF) to advance US leadership in nuclear science and technology. By attracting new users from universities, laboratories, and industry, this program supports basic and applied nuclear research to help address the nation's energy security needs. In support of this program, the Idaho National Laboratory (INL) established in-house capabilities to develop, fabricate, test, and qualify new and enhanced temperature sensors for irradiation testing. This effort is continuing today through the DOE?s Advanced Sensors and Instrumentation (ASI) program. Although most efforts emphasize sensors capable of providing real-time data, selected tasks have been completed to enhance passive sensors for irradiations where instrumentation leads cannot be included. These sensors include silicon carbide (SiC) monitors, melt wires and the sublime temperature monitor. SiC monitors are available to detect peak irradiation temperatures between 200°C and 800°C in reactor locations where instrumentation leads cannot be used. SiC monitors may be evaluated using specialized equipment installed at INL?s Measurement Sciences Laboratory (MSL). A melt wire inventory is also maintained at MSL. This inventory contains wires for specific use in irradiation experiments ranging in temperatures from 30°C to 1500°C. Melt wires and SiC monitors have had decades of research and application. Recent research has produced a passive monitor known as the sublime temperature monitor. This passive sensor has the capability of recording temperature gradients. This paper will discuss passive temperature sensors currently being researched and implemented under the ASI program.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A reduced-order modeling of a tubular solar reactor for long duration thermochemical energy storage

The storage of solar energy in a solid form, referred to as a “solar fuel”, can be achieved through a process known as endothermic solar thermochemistry. This process transforms the absorbed solar energy into a stable and retrievable form that can be stored for extended periods of time. This paper presents a low–order heat transfer model of a counter–current tubular falling bed reactor designed to produce thermally reduced magnesium manganese oxide pellets for long duration thermochemical energy storage. The energy required for the endothermic reduction was supplied by concentrated solar energy or renewable electricity via indirect heating of the gas and solid reactants flowing in a ceramic tube. The counter-current gas flow enhances the mixing of the solid particles with the heat recuperation zone, allowing the gas and particles to enter and exit the tubular reactor close to room temperature. Further, the reactor was vertically oriented and was heated circumferentially by an adjustable level heat flux along a finite segment of its length. The temperature distribution of the reactor in response to transient changes along the tube was modeled by considering conduction, convection, and radiation heat transfer. Governing equations for the heat transfer model were solved by discretizing the reactor tube into a finite number of control volumes and using an energy balance for the heat exchange between the reactor wall, gas, and particles within the control volume. The energy absorbed during this endothermic reaction was modeled numerically by fitting the data of the chemical conversion rate with the corresponding temperature of particles in the heating zone. The numerical model has been experimentally validated using a reactor prototype made of a 121.92 cm alumina tube heated by a 7kW electric tube–furnace. The alumina tube receives magnesium manganese oxide pellets of 3.66±0.516 mm in diameter from the top, and a counter–current gas flow from the bottom. The reactor wall temperature was monitored by six thermocouples installed along the reactor tube length. The experimental procedure was numerically simulated, and the temperature variation along the reactor tube was compared with a matrix of experimental runs for a range of particles mass flowrates (0.75–1.25g/s) and corresponding gas flowrates (36–65 SLPM). The reactor system was heated gradually from room temperature to a steady state temperature of 1673K, and then cooled down to room temperature. The heating and cooling processes were simulated, and the numerical and experimental results were compared throughout processes. The numerical model showed similar trends to the experimental results, with an error of 0.69 to 7.9% for the particle inlet and 0.7 to 7.9% for the gas inlet during steady-state operation. The proposed numerical model can be implemented as a simplified physical model to design a feedback control system to regulate reactor temperature.

14 SOLAR ENERGY↗

Transformers and Long Short-Term Memory Transfer Learning for GenIV Reactor Temperature Time Series Forecasting

Automated monitoring of the coolant temperature can enable autonomous operation of generation IV reactors (GenIV), thus reducing their operating and maintenance costs. Automation can be accomplished with machine learning (ML) models trained on historical sensor data. However, the performance of ML usually depends on the availability of large amount of training data, which is difficult to obtain for GenIV, as this technology is still under development. We propose the use of transfer learning (TL), which involves utilizing knowledge across different domains, to compensate for this lack of training data. TL can be used to create pre-trained ML models with data from small-scale research facilities, which can then be fine-tuned to monitor GenIV reactors. In this work, we develop pre-trained Transformer and long short-term memory (LSTM) networks by training them on temperature measurements from thermal hydraulic flow loops operating with water and Galinstan fluids at room temperature at Argonne National Laboratory. The pre-trained models are then fine-tuned and re-trained with minimal additional data to perform predictions of the time series of high temperature measurements obtained from the Engineering Test Unit (ETU) at Kairos Power. The performance of the LSTM and Transformer networks is investigated by varying the size of the lookback window and forecast horizon. The results of this study show that LSTM networks have lower prediction errors than Transformers, but LSTM errors increase more rapidly with increasing lookback window size and forecast horizon compared to the Transformer errors.

LSTM↗

Predicting melt pool depth and grain length using multiple signatures from in-situ single camera two-wavelength imaging pyrometry for laser powder bed fusion

In laser powder bed fusion (LPBF), the in-situ process signatures are known to have a direct correlation with the microstructural properties of the solidified melt pool (MP). It is known that the MP cooling and heating rates, and laser processing parameters can critically determine the grain structure and thereby affect the part properties. The objective of this work is to study the feasibility of using in-process, high-speed imaging pyrometry for evaluating the solidified MP properties “below” the surface, such as depth and microstructural properties. To accomplish this, we employ an in-house single camera-based two-wavelength imaging pyrometry (STWIP) system for monitoring the printing of single-scan tracks with Inconel 718 on a commercial LPBF printer (EOS M290). Further, the lab designed STWIP system is a coaxial high-speed (>10,000 fps) imaging system capable of monitoring MP temperature, morphology, and intensity profiles. The temperature measurements from STWIP are emissivity independent. The STWIP measured MP signatures of the printed tracks are correlated with the ex-situ microscopy characterized MP depth and the average grain lengths. From the data analysis, using support vector machine (SVM)-based regression models, we found that the MP temperature signatures are crucial for an accurate prediction of MP depth and the grain length, thus validating the novelty and necessity of the developed in-situ monitoring methods and analysis.

36 MATERIALS SCIENCE↗

Machine Learning Analysis of Temperature-Strain Relationships for Structural Health Monitoring of Pipes: Self-powered wireless sensor system for health monitoring of liquid-sodium cooled fast reactors

This report presents machine learning (ML) analysis of temperature-strain relationships for structural health monitoring of nuclear reactor stainless steel (SS) pipes with the strain gauge sensor directly printed on the pipe with a 3D conformal aerosol jet printer. We investigate correlations for two sensor pairs installed on the same SS304 pipe: commercial K-type thermocouple with a printed gold strain gauge (TC3-SG3), and commercial K-type thermocouple with commercial Kyowa strain gauge (TC0-SG0). The temperature ranges for the sensor pairs TC0-SG0 and TC3-SG3 are 20.00°C to 266.37°C and 39.95°C to 219.28°C respectively. ML algorithms in this study include Linear Regression (baseline method), Ridge Regression, Lasso Regression, and Gradient Boosting. Performance evaluation metrics include Root Mean Square Error (RMSE), Mean Square Error (MSE), Mean Absolute Error (MAE), R 2 Score, and Explained Variance. Using advanced feature engineering techniques, we extracted 27 temperature-based features and 30 strategic inclusion features. The best performance was obtained with the Gradient Boosting method, which achieves prediction accuracy of R 2 = 0.9999 and RMSE = 7.69 μStrain for TC0-SG0, and R 2 = 0.9998 and RMSE = 18.03 μStrain for TC3-SG3. While the temperature-strain correlations are weaker for the gauge directly printed on the pipe than for the commercial strain gauge, deployment-ready performance exceeding industry standards is achieved for both sensor pairs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of Ion Irradiation on Amorphous and Crystalline Ge–Se and Their Application as Phase Change Temperature Sensor

Research on phase change materials is predominantly focused on their application as memory devices or for temperature control which requires low phase change temperature. The Ge–Se binary chalcogenide glass system with its wide glass-forming region is a potential candidate for high-temperature and high-radiation phase change applications. In this study, the concept of employing Ge x Se 100– x glasses to monitor high temperature (450–528 °C) using the phase change effect, is reported. Materials selection, device structure, and performance of prototype sensors are analyzed. In addition, the effect of heavy ion irradiation by Xe ions with energies of 200, 600, and 1000 keV (fluence ≈10 14 cm –2 ) on the Ge x Se 100– x ( x = 30, 33, 40) thin films and phase change devices is studied. The irradiation effect on the amorphous and crystalline structure of the thin films is evaluated by Raman spectroscopy and X-ray diffraction (XRD). Although the changes in the structural units of amorphous films are negligible, in crystalline films orthorhombic-GeSe 2 crystals are found to be most affected by irradiation and a new phase, orthorhombic GeSe is found in the thin films after irradiation. The performance of a sensor with an active film of Ge 40 Se 60 is also shown as an example.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Temperature-dependent calibration procedures for the silicon photomultiplier readout of the cosmic ray veto detector for the Mu2e experiment

The cosmic ray veto detector for the Mu2e experiment consists of scintillation bars embedded with wavelength-shifting fibers and read out by silicon photomultipliers (SiPMs). Here, in this manuscript, the calibration procedures of the SiPMs are described including corrections for the temperature dependence of their light yield. These corrections are needed as the SiPMs are not kept at a constant temperature due to the complexity and cost of implementing a cooling system on such a large detector. Rather, it was decided to monitor the temperature to allow the appropriate corrections to be made. The SiPM temperature dependence has been measured in a dedicated experiment and the calibration procedures were validated with data from production detectors awaiting installation at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mitigating urban heat island and enhancing indoor thermal comfort using terrace garden

The United Nations advocates for sustainable urban planning and design, emphasizing green infrastructure initiatives to mitigate urban heat island effects and enhance the resilience and livability of cities globally. To address urban heat challenges, a study was conducted in Chennai, India, from April to June 2023. The study focused on assessing temperature dynamics on a building's terrace by comparing a well-maintained garden area with an exposed region. Temperature and humidity sensors were deployed in both the garden and exposed areas of the terrace, as well as within rooms beneath it, to monitor hourly temperature fluctuations. The findings indicate a significant reduction in internal room temperatures in areas with rooftop gardens, ranging from 4 to 11 °C, depending on the time of year and sun's position, compared to rooms with fully exposed roof configurations. Additionally, simulation studies were performed to validate these findings, suggesting that optimizing the distribution of soil beds and plant density across the roof could yield an additional temperature reduction of 3–4 °C, resulting in an overall difference of up to 14–15 °C. The study highlights the efficacy of rooftop gardens in providing cooling effects during daylight hours and maintaining temperature parity post-sunset. Through analysis of sensor data, the research elucidates the intricate relationship between green infrastructure and thermal comfort, offering insights for energy-efficient building design and resilient urban planning. The findings underscore the potential of rooftop gardens in fostering a more comfortable, energy-efficient, and sustainable urban living environment.

54 ENVIRONMENTAL SCIENCES↗