Entry dynamics performance predictions for Pioneer Venus probes

The scientific experiments planned for the Pioneer Venus entry probes require that the probes provide a stable platform at a controlled roll rate throughout the atmospheric phase of the mission. The 45-degree half-cone forebody common to both the small and large probe configurations provides a design which meets all stability and attitude requirements. The uncertainty in the dynamic stability parameter coupled with the possible variability of roll rate due to ablation induced roll torques could, however, result in slight angle of attack divergence in the transonic flight regime. Minimum roll rate requirements on the small probe are passively achieved by a vane mounted on the pressure-temperature sensing arm. The vane was sized to provide minimum dynamic disturbance.

Mccloy, R. D.↗

Geologic application of thermal inertia imaging using HCMM data

The feasibility of using thermal inertia, inferred from remotely sensed temperature data, to complement LANDSAT reflectivity data for reconnaissance geologic mapping and mineral exploration is under investigation. The bulk of HCMM data tapes was received and processed, and a thermal inertia image of one data set was made. Additional areas of interest were identified on the HCMM photographic products and data tapes were ordered for these areas. During analysis of selected subareas, various sedimentary rock units were distinguished in the Death Valley, California test site and areas of altered rock were identified in the Cuprite/Goldifield, Nevada test site.

Paley, H. N.↗

Detection of Gas Slugs in Heat Pipes

Temperature sensing system detects presence of gas slugs in heat pipes. System designed for operation between zero and 70 degrees C and detects noncondensable pockets of gas that result from decomposition of ammonia cooling fluid. Slugs 1 in. (25mm) in length detected.

Jones, J. A.↗

Shuttle flight data analysis

As the STS moves into routine operations, the direction of the work is shifting to an in-depth assessment of performance and its impact on the design and development of a future generation of vehicles. Particular emphasis is placed on providing an accurate physical explanation of anomalies, assessing the quality of simulation provided by the ground test facilities utilized, understanding the ground to flight extrapolation procedures, and the limitations of theoretical prediction techniques. The results are expected to provide direction and focus for future research and technology programs to enable substantial technological improvements in the next generation vehicles. The recent approval of the Orbital Experiments (OEX) Program's Shuttle Infrared Leeside Temperature Sensing (SILTS), Shuttle Entry Air Data System (SEADS), and Shuttle Upper Atmospheric Mass Spectrometer (SUMS) experiments to be integrated for flight on OV-102 in late 1985 is a firm indication of a strong commitment to a continuing and vigorous program in shuttle flight data analysis.

Walberg, G. D.↗

Bulk undercooling

Bulk undercooling methods and procedures will first be reviewed. Measurement of various parameters which are necessary to understand the solidification mechanism during and after recalescence will be discussed. During recalescence of levitated, glass-encased large droplets (5 to 8 mm diam) high speed temperature sensing devices coupled with a rapid response oscilloscope are now being used at MIT to measure local thermal behavior in hypoeutectic and eutectic binary Ni-Sn alloys. Dendrite tip velocities were measured by various investigators using thermal sensors or high speed cinematography. The confirmation of the validity of solidification models of bulk-undercooled melts is made difficult by the fineness of the final microstructure, the ultra-rapid evolution of the solidifying system which makes measurements very awkward, and the continuous modification of the microstructure which formed during recalescence because of precipitation, remelting and rapid coarsening.

Kattamis, T. Z.↗

Airborne infrared low level wind shear predictor

The operating principles and test performance of an airborne IR (13-16 micron) temperature-sensing detection and warning system for low-level wind shear (LLWS) are presented. The physics of LLWS phenomena and of the IR radiometer are introduced. The cold density-current outflow or gust front related to LLWS is observed in the IR spectrum of CO2 by a radiometer with + or - 0.5-C accuracy at 0.5-Hz sampling rate; LLWS alerts are given on the basis of specific criteria. Test results from the JAWS experiments conducted at Denver in July 1982, are presented graphically and discussed. The feasibility of the passive IR system is demonstrated, with an average warning time of 51 sec, corresponding to a distance from touchdown of about 2 miles.

Kuhn, P. M.↗

Comprehensive analysis of Shuttle Orbiter leeside surface infrared imagery obtained during atmospheric entry

The thermographic analysis techniques developed for processing of data from the Shuttle Infrared Leeside Temperature Sensing (SILTS) experiment are discussed. The SILTS experiment will obtain high-spatial-resolution infrared images of the leeside of the Space Shuttle Orbiter during atmospheric entry by means of a scanning infrared radiometer located atop the orbiter's vertical stabilizer. Comprehensive analysis of the SILTS thermography requires accurate consideration of all those factors (such as geometry of the observed surfaces, local surface emissivity, solar radiation, and other potential sources of image degradation) which may potentially affect the output of the infrared radiometer. An overview of the entire data processing procedure and brief descriptions of the data processing algorithms are presented.

Myrick, D. L.↗

Advanced sensible heat solar receiver for space power

NASA Lewis, through in-house efforts, has begun a study to generate a conceptual design of a sensible heat solar receiver and to determine the feasibility of such a system for space power applications. The sensible heat solar receiver generated in this study uses pure lithium as the thermal storage medium and was designed for a 7 kWe Brayton (PCS) operating at 1100 K. The receiver consists of two stages interconnected via temperature sensing variable conductance sodium heat pipes. The lithium is contained within a niobium vessel and the outer shell of the receiver is constructed of third generation rigid, fibrous ceramic insulation material. Reradiation losses are controlled with niobium and aluminum shields. By nature of design, the sensible heat receiver generated in this study is comparable in both size and mass to a latent heat system of similar thermal capacitance. The heat receiver design and thermal analysis was conducted through the combined use of PATRAN, SINDA, TRASYS, and NASTRAN software packages.

Bennett, Timothy J.↗

Structure and recalescence behavior of undercooled nickel-tin alloys

The effects of undercooling on the thermal behavior and structure of Ni-Sn alloys are investigated. Hypoeutectic (Ni-25 wt pct Sn) and eutectic (Ni-32.5 wt pct Sn) compositions of the Ni-Sn alloy were undercooled using a levitation melting with glass encasement technique, and the recalescence of these alloys was measured using a high speed temperature sensing device and a digital oscilloscope. It is observed that in both samples the total solidification and recalescence times decrease with increasing undercooling; the volume fraction of normal lamellar eutectic decreases with increasing undercooling; and in the hypoeutectic sample, the morphology of the primary phase changes from dendritic to spherical with increasing undercooling.

Wu, Yanzhong↗

Rapid solidification of levitation melted Ni-Sn alloy droplets with high undercooling

Experimental results obtained by high-speed optical temperature sensing for the rapid solidification of highly undercooled, levitation-melted Ni-Sn alloy droplets are presented. These data suggest a solidification model proceeding according to overlapping steps: (1) dendritic growth within the bulk undercooled melt, (2) continued recalescence as supersaturation of the interdendritic liquid dissipates, (3) fine-scale remelting within the dendrites, (4) ripening of the fine structure, and (5) solidification of remaining liquid at the end of recalescence.

Shiohara, Yuh↗

Advanced sensible heat solar receiver for space power

NASA Lewis, through in-house efforts, has begun a study to generate a conceptual design of a sensible heat solar receiver and to determine the feasibility of such a system for space power applications. The sensible heat solar receiver generated in this study uses pure lithium as the thermal storage medium and was designed for a 7 kWe Brayton (PCS) operating at 1100 K. The receiver consists of two stages interconnected via temperature sensing variable conductance sodium heat pipes. The lithium is contained within a niobium vessel and the outer shell of the receiver is constructed of third generation rigid, fibrous ceramic insulation material. Reradiation losses are controlled with niobium and aluminum shields. By nature of design, the sensible heat receiver generated in this study is comparable in both size and mass to a latent heat system of similar thermal capacitance. The heat receiver design and thermal analysis were conducted through the combined use of PATRAN, SINDA, TRASYS, and NASTRAN software packages.

Bennett, Timothy J.↗

Exploiting operational vehicles for in-flight research - Space Shuttle and Space Station Freedom

Five Orbiter Experiments in which NASA's Langley Research Center has had significant involvement are described. These experiments are the Shuttle Infrared Leeside Temperature Sensing experiment, the Shuttle Upper Atmosphere Mass Spectrometer experiment, the High Resolution Accelerometer Package experiment, the Orbital Acceleration Research experiment, and the Space Station structural characterization experiment. The Shuttle Entry Air Data System is also described.

Holloway, Paul F.↗

Testing, analysis, and code verification of aerodynamics and heat transfer related to turbomachinery

Discussed here are the writing of a data acquisition code and the installation and testing of new pressure and temperature instrumentation to be used in the testing and evaluation of miniature heat flux sensors. A brief summary of the problem which led to the need for these tests is presented as well as a proposed data acquisition program and the results of investigations of two measurement systems, the Omega OM-900 temperature sensing system and the Scani-Valve Hyscan pressure measurement system.

King, Paul I.↗

An overview of the results of the FIFE-87 and FIFE-89 campaigns

Results of a major land surface-atmosphere exchange study, the First ISLSCP Field Experiment (FIFE) are summarized. Findings result from nearly 80 days of field measurements over a 15 kilometer square area involving 30 science teams, seven remote sensing aircraft, and 5 satellites which acquired over 1200 low resolution and 35 high spatial resolution satellite images, maps of remotely sensed temperature, vegetation index and soil moisture, surface flux measurements from more than 20 ground stations and airborne sensors, and transects of vegetation, soil moisture and soil chemistry. Relationships between in situ, airborne, and spaceborne remote measurements and the problem of scaling will be discussed. Energy balance comparisons among sites were made. Diurnal measurements of latent heat fluxes indicated a strong correlation between the evaporative fraction at midday and the daytime average value.

Murphy, R. E.↗

A millimeter-wave radiometer for detecting microbursts

This paper describes a millimeter-wave radiometer for the detection of wind shear from airborne platforms or at airport terminals. This proposed instrument will operate near the group of atmospheric oxygen absorptions centered near 60 GHz, which it will use to sense temperature from a distance. The instrument will use two channels to provide two different temperature measurements, providing the basis for solution of two equations in two unknowns, which are range to the wind shear plume and its temperature. A third channel will measure ambient atmospheric temperature. Depending on the temperature difference between the wind-shear plume and ambient, the standard deviation of range measurement accuracy is expected to be about 1 km at 5 km range, while the temperature measurement standard deviation will be about one-fourth the temperature difference between plume and ambient at this range. The instrument is expected to perform usefully at ranges up to 10 km, giving adequate warning of the presence of wind shear even for high performance jet aircraft. Other atmospheric hazards which might be detected by this radiometer include aircraft wakes and vortices, clear-air turbulence, and wind rotors, although the latter two phenomena would be detected by an airborne version of the instrument. A separate radiometer channel will be provided in the proposed instrument to detect aircraft wakes and vortices based on perturbation of the spectrum of microscopic atmospheric temperature fluctuations caused by the passage of large aircraft.

Mcmillan, Robert↗

Generic Propellants Transfer Unit (GPTU)

The Generic Propellants Transfer Unit (GPTU) is being designed to support spacecraft liquid propellant operations at the Kennedy Space Center (KSC) and Eastern Test Range (ETR). The GPTU will have a 500 gallon capacity and be Department Of Transportation (DOT) approved for over-the-road transportation of hypergolic propellants. The use of these containers will allow the users to increase efficiency and reduce the following costs: design/construction, transportation (to/from the launch site), propellant transfer operations, and decontamination operations. The user also acquires the flexibility of transporting to an offsite location for processing or storage without obtaining special exemptions or permits. These containers will incorporate their own quantity gaging and temperature sensing systems, and be integrated onto a transport trailer which contains work platforms and a fluid transfer system.

Cook, Christopher A.↗

Fourier transform spectrometry for fiber-optic sensor systems

An integrated-optic Mach-Zehnder interferometer is used as a Fourier transform spectrometer to analyze the input and output spectra of a temperature-sensing thin-film etalon. This type of spectrometer has an advantage over conventional grating spectrometers because it is better suited for use with time-division-multiplexed sensor networks. In addition, this spectrometer has the potential for low cost due to its use of a component that could be manufactured in large quantities for the optical communications industry.

Beheim, Glenn↗

Fiber-optic thermometer using Fourier transform spectroscopy

An integrated-optic Mach-Zender interferometer is used as a Fourier transform spectrometer to analyze the input and output spectra of a temperature-sensing thin-film etalon. This configuration provides a high degree of immunity to the effects of changes in the source spectrum, and it readily permits the interrogation of a number of different sensors using a single spectrometer. In addition, this system has a potentially low cost because it uses optical communications hardware that may in the future be manufactured in large quantities.