Elevated temperature tensile and creep behavior of a SiC fiber-reinforced titanium metal matrix composite
In this research program, the tensile properties and creep behavior in air of (0)(sub 4), (0/90)(sub s) and (90)(sub 4) SCS-9/Beta 21S composite layups with 0.24 volume fraction fiber were evaluated. Monotonic tensile tests at 23, 482, 650 and 815 C yielded the temperature dependence of the elastic modulus, proportional limit, ultimate tensile strength and total strain at failure. At 650 C, the UTS of the (0)(sub 4) and (0/90)(sub s) layups decreases by almost 50 percent from the room temperature values, indicating that operating temperatures should be less than 650 C to take advantage of the specific tensile properties of these composites.