Search NASA⌕ Search

SEARCH · Search NASA

Results for “testing facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

STEADY STATE MODELING OF THE MINIMUM CRITICAL CORE OF THE TRANSIENT REACTOR TEST FACILITY

With the advent of next generation reactor systems and new fuel designs, the U.S. Department of Energy (DOE) has identified the need for the resumption of transient testing of nuclear fuels. The DOE has decided that the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory (INL) is best suited for future testing. TREAT is a thermal neutron spectrum, air-cooled, nuclear test facility that is designed to test nuclear fuels in transient scenarios. These specific scenarios range from simple temperature transients to full fuel melt accidents. DOE has expressed a desire to develop a simulation capability that will accurately model the experiments before they are irradiated at the facility. It is the aim for this capability to have an emphasis on effective and safe operation while minimizing experimental time and cost. The multi physics platform MOOSE has been selected as the framework for this project. The goals for this work are to identify the fundamental neutronics properties of TREAT and to develop an accurate steady state model for future multiphysics transient simulations. In order to minimize computational cost, the effect of spatial homogenization and angular discretization are investigated. It was found that significant anisotropy is present in TREAT assemblies and to capture this effect, explicit modeling of cooling channels and inter-element gaps is necessary. For this modeling scheme, single element calculations at 293 K gave power distributions with a root mean square difference of 0.076% from those of reference SERPENT calculations. The minimum critical core configuration with identical gap and channel treatment at 293 K resulted in a root mean square, total core, radial power distribution 2.423% different than those of reference SERPENT solutions.

Critical↗

Tracer gas test in Net-Zero Energy Residential Test Facility

The Net-Zero Energy Residential Test Facility (NZERTF) at NIST was built in 2012 to support the development and adoption of cost-effective net-zero energy designs, technologies, and construction methods. It is two-story, and has four bedrooms, three bathrooms, and an open living room, dining room, and kitchen space. The NZERTF also has a basement and attic, both located within the conditioned space because the thermal and air-moisture barriers encompass the basement walls and attic roof. Transfer grilles link the living spaces to these two zones. The central heating and cooling system includes an air-toair heat pump, which delivers air to the basement, first and second floors. The heat pump has a cooling capacity of 7.6 kW and a heating capacity of 7.8 kW. The indoor unit is in the basement and ductwork runs along the basement ceiling. A balanced heat recovery ventilator (HRV) is installed in the basement and has its own dedicated ductwork. The HRV supplies 47 L/s of outdoor air to the house, with supplies on the first floor (in the kitchen/dining area) and in each of the three second-floor bedrooms. Air from the first-floor bathroom and both second-floor bathrooms is returned to the HRV before being exhausted, though the HRV was turned off during the tests. The house also has a range hood exhaust and a clothes dryer exhaust, both of which were turned off for the tests. The temperature of the house was measured and the operation of the space conditioning system, including its recirculating air distribution fan, were controlled by a commercially available thermostat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of the cryostat for High Field Vertical Magnet Testing Facility at Fermilab

High Field Vertical Magnet Test Facility (HFVMTF) is a joint project between the Office of High Energy Physics (HEP) and the Office of Fusion Energy Sciences (FES). Its construction is currently under way at Fermi National Accelerator Laboratory (Fermilab). As a part of the project a new double bath superfluid helium cryostat has been designed. The cryostat can accommodate magnets with up to 20 tonne weight and 1.3 m diameter. This paper discusses challenges and solutions for cryostat, lambda plate and heat exchanger design, and presents results of performance analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RELAP5-3D Input Model for the High Temperature Test Facility

A RELAP5-3D model of the High Temperature Test Facility at Oregon State University has been developed. The model includes the systems, components, and controls needed to perform code assessment calculations using data from the facility. Details of the model are provided. The input was developed for RELAP5-3D Version 4.4.2.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spark Plasma Sintering (SPS) Update for the Fuel Conversion Effort at the Transient Reactor Test Facility

Over the lifetime of the Transient Reactor Test Facility (TREAT) reactor from 1959 to 1994, a series of historical tests disclosed certain material specific requisites for irradiation testing variables resulted in negligible structural damage after exposure to the reactor and multiple experiments. Comparable fuel design, material testing, and qualifications needs to occur for the high-enriched uranium (HEU) to low enriched uranium (LEU) fuel conversion (<20% U235) of TREAT. This includes, retaining a uniform precipitate dispersion of fueled UO2 micron-size particles throughout a graphite-moderating matrix, where high-density graphite is in direct contact with the fuel and acts as a moderator. On that note, the design of future LEU reactor TREAT fuel core will consider the relative sizing and spacing of fuel as well as the retention of graphite in accordance with the expected thermal, neutron, and energy portfolio for future conversion. In light of the above, LEU conversion fuel blocks currently being manufactured must undergo critical materials testing, irradiation, and examination to determine effects on the manufactured replacement fuel blocks at the millimeter to sub-micron size scale. Herein, we will report and update the community on value-added studies focusing on spark plasma sintering as an alternative technique to fabricate high density graphite dispersion fuel.

36 MATERIALS SCIENCE↗

New Approach and Test Facility for High Field Accelerator Magnets R&D

This paper presents a new approach for developing and demonstrating high field magnet technology based on a magnet and test facility developed specifically for it. The traditional approach for carrying out high field magnet R&D has been building a new magnet to demonstrate a new design, new material or new technology. However, building a high field magnet is time consuming and expensive. To overcome this limitation, Brookhaven National Laboratory (BNL) built and successfully tested a 10 T Nb 3 Sn dipole DCC017 with large enough open or clear space (31 mm wide and 338 mm high) so that a pair of racetrack coils could be inserted into this opening without disassembling the magnet. The motivation be-hind this design was to facilitate a magnet R&D program where the new coils (with a large range in width and height accommodated) would reside in a high field region in direct contact with the existing coils (just as other magnet coils) and thus become an integral part of the magnet. We summarize the approach, the magnet, the test facility, past experiences, current and future test plans and planned up-grade. Here, the magnet facility is now available to service the needs of the wider community for testing cable and insert coils in a back-ground field of up to 10 T.

43 PARTICLE ACCELERATORS↗

Physical and Experimental Background of the Design of the ELISE Test Facility

In 2007 the IPP RF driven negative hydrogen ion source was chosen by the ITER board as the new reference source for the ITER neutral beam system. In order to support the design of the Neutral Beam Test Facility in Padua and its commissioning and operating phases, IPP is presently constructing a new test facility ELISE (Extraction from a Large Ion Source Experiment) for a large-scale extraction from a half-size ITER RF source. Plasma operation of up to one hour is foreseen; but due to the limits of the IPP HV system, pulsed extraction only is possible. The extraction system is designed for acceleration of negative ions of up to 60 kV. The start of the ELISE operation is planned for middle of 2010. The aim of the design of the ELISE source and extraction system was to be as close as possible to the ITER design; it has however some modifications allowing a better diagnostic access as well as more flexibility for exploring open questions. The design was also supported by diagnostics and modeling efforts of the processes leading to negative ion production and extraction in a RF source.

43 PARTICLE ACCELERATORS↗

Design of a Test Article and Test Facility to Investigate Flow-Induced Vibration of a Helical Coil Steam Generator

NuScale Power LLC (NuScale) is developing a small modular reactor (SMR) with unique design features and arrangements that require testing to provide quality data for safety analysis codes and design validation, as well as for technology maturation. A multi-phase testing program is underway at NuScale to demonstrate that its unique helical coil steam generator design is not susceptible to flow-induced vibration during operation. The phases of the testing program include modal testing of individual tubes during test article fabrication and modal and flow testing after test article completion. NuScale has contracted SIET S.p.A. in Piacenza, Italy for the design and fabrication of the test article and test facility. In-fabrication testing was performed at the site of test article build in Cremosano, Italy. Modal testing and flow testing of the completed test article will be performed at SIET’s facilities in Piacenza. This paper discusses the design of the test article and test facility, including supporting systems, required to generate the quality data required to support NuScale’s comprehensive vibration assessment program as part of the overall licensing effort for NuScale’s first-of-a-kind small modular light water reactor.

Flow-induced vibration, helical coil, steam genera↗

NaREC Offshore and Drivetrain Test Facility Collaboration: Cooperative Research and Development Final Report, CRADA Number CRD-04-140

The National Renewable Energy Laboratory (NREL) and the National Renewable Energy Centre (NaREC) in the United Kingdom (UK) have a mutual interest in collaborating in the development of full-scale offshore wind energy and drivetrain testing facilities. NREL and NaREC will work together to share resources and experiences in the development of future wind energy test facilities. This Cooperative Research and Development Agreement (CRADA) includes sharing of test protocols, infrastructure cost data, test plans, pro forma contracting instruments, and safe operating strategies. Furthermore, NREL and NaREC will exchange staff for training and development purposes.

17 WIND ENERGY↗

Cleaning residual NaK in the fast flux test facility fuel storage cooling system

The Fast Flux Test Facility (FFTF), located on the U.S. Department of Energy's Hanford Reservation, is a liquid metal-cooled test reactor. The FFTF was constructed to support the U.S. Liquid Metal Fast Breeder Reactor Program. The bulk of the alkali metal (sodium and NaK) has been drained and will be stored onsite prior to final disposition. Residual NaK needed to be removed from the pipes, pumps, heat exchangers, tanks, and vessels in the Fuel Storage Facility (FSF) cooling system. The cooling system was drained in 2004 leaving residual NaK in the pipes and equipment. The estimated residual NaK volume was 76 liters in the storage tank, 1.9 liters in the expansion tank, and 19-39 liters in the heat transfer loop. The residual NaK volume in the remainder of the system was expected to be very small, consisting of films, droplets, and very small pools. The NaK in the FSF Cooling System was not radiologically contaminated. The portions of the cooling system to be cleaned were divided into four groups: 1. The storage tank, filter, pump, and associated piping; 2. The heat exchanger, expansion tank, and associated piping; 3. Argon supply piping; 4. In-vessel heat transfer loop. The cleaning was contracted to Creative Engineers, Inc. (CEI) and they used their superheated steam process to clean the cooling system. It has been concluded that during the modification activities (prior to CEI coming onsite) to prepare the NaK Cooling System for cleaning, tank T-914 was pressurized relative to the In-Vessel NaK Cooler and NaK was pushed from the tank back into the Cooler and that on November 6, 2005, when the gas purge through the In-Vessel NaK Cooler was increased from 141.6 slm to 283.2 slm, NaK was forced from the In-Vessel NaK Cooler and it contacted water in the vent line and/or scrubber. The gases from the reaction then traveled back through the vent line coating the internal surface of the vent line with NaK and NaK reaction products. The hot gases also exited the scrubber through the stack and due to the temperature of the gas, the hydrogen auto ignited when it mixed with the oxygen in the air. There was no damage to equipment, no injuries, and no significant release of hazardous material. Even though the FSF Cooling System is the only system at FFTF that contains residual NaK, there are lessons to be learned from this event that can be applied to future residual sodium removal activities. The lessons learned are: - Before cleaning equipment containing residual alkali metal the volume of alkali metal in the equipment should be minimized to the extent practical. As much as possible, reconfirm the amount and location of the alkali metal immediately prior to cleaning, especially if additional evolutions have been performed or significant time has passed. This is especially true for small diameter pipe (<20.3 centimeters diameter) that is being cleaned in place since gas flow is more likely to move the alkali metal. Potential confirmation methods could include visual inspection (difficult in all-metal systems), nondestructive examination (e.g., ultrasonic measurements) and repeating previous evolutions used to drain the system. Also, expect to find alkali metal in places it would not reasonably be expected to be. - Staff with an intimate knowledge of the plant equipment and the bulk alkali metal draining activities is critical to being able to confirm the amount and locations of the alkali metal residuals and to safely clean the residuals. - Minimize the potential for movement of alkali metal during cleaning or limit the distance and locations into which alkali metal can move. - Recognize that when working with alkali metal reactions, occasional pops and bangs are to be anticipated. - Pre-plan emergency responses to unplanned events to assure responses planned for an operating reactor are appropriate for the deactivation phase.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scaling and Design Analysis of a Sub-Scale, Reduced Temperature Stratified Flow Separate Effects Test Facility for the Experimental Investigation of Air Ingress in a High Temperature Reactor System

High temperature gas reactors (HTGR) are poised to spearhead the next generation of nuclear reactors, due to their passive safety characteristics and their applications flexibility. Able to provide base load power or process heat for industrial applications, HGTRs may be a critical component to reducing greenhouse gas emissions in the United States and abroad. However, increased interest and development has also highlighted areas requiring further investigation, one of which being the air-ingress accident. Air ingress may occur following a break in the coaxial cross duct and pressure vessel depressurization. The initial mode of ingress is hypothesized to be density driven cross flow as the cold air enters the lower plenum, at which point molecular diffusion and/or local buoyancy phenomena will dominate until a global natural circulation current is established. While computational simulations support this progression, little or no experimental data exists to validate and support this phenomenology. Therefore, it is necessary to generate such data; this research seeks to do so through the use of a sub-scale separate effects test facility - the Stratified Flow Separate Effects Test Facility (SFSETF). The goal of this facility is more specifically to focus on the transition to global natural circulation starting from air ingress after a double-ended guillotine break (DEGB) while neglecting depressurization. This paper will provide analyses performed in the design of this facility, including the geometric and hydraulic scaling analyses, safety analysis and instrumentation selection. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Vibrational Stability of SRF Accelerator Test Facility at Fermilab

Recently developed, the Superconducting Radio Frequency (SRF) Accelerator Test Facilities at Fermilab support the International Linear Collider (ILC), High Intensity Neutrino Source (HINS), a new high intensity injector (Project X) and other future machines. These facilities; Meson Detector Building (MDB) and New Muon Lab (NML) have very different foundations, structures, relative elevations with respect to grade level and surrounding soil composition. Also, there are differences in the operating equipment and their proximity to the primary machine. All the future machines have stringent operational stability requirements. The present study examines both near-field and ambient vibration in order to develop an understanding of the potential contribution of near-field sources (e.g. compressors, ultra-high and standard vacuum equipment, klystrons, modulators, utility fans and pumps) and distant noise sources to the overall system displacements. Facility vibration measurement results and methods of possible isolation from noise sources are presented and discussed.

43 PARTICLE ACCELERATORS↗

Concepts for the magnetic design of the MITICA neutral beam test facility ion accelerator

The megavolt ITER injector concept advancement neutral injector test facility will be constituted by a RF-driven negative ion source and by an electrostatic Accelerator, designed to produce a negative Ion with a specific energy up to 1 MeV. The beam is then neutralized in order to obtain a focused 17 MW neutral beam. The magnetic configuration inside the accelerator is of crucial importance for the achievement of a good beam efficiency, with the early deflection of the co-extracted and stripped electrons, and also of the required beam optic quality, with the correction of undesired ion beamlet deflections. Several alternative magnetic design concepts have been considered, comparing in detail the magnetic and beam optics simulation results, evidencing the advantages and drawbacks of each solution both from the physics and engineering point of view.

43 PARTICLE ACCELERATORS↗

Computer Codes V and V Tests with a Large-Scale Sodium Thermal-Hydraulic Test Facility (STELLA)

The Korea Atomic Energy Research Institute (KAERI) is carrying out the design of a 'Prototype Generation IV Sodium-cooled Fast Reactor (PGSFR)' in cooperation with Argonne National Laboratory (ANL) in the US. In regard to computer codes V and V, a large-scale sodium thermal-hydraulic test program is currently being progressed in parallel with the PGSFR design, which is called STELLA (Sodium Test Loop for Safety Simulation and Assessment). The final objective of this program is to collect a separate and integral effect test database to validate the safety analysis codes and other thermal hydraulic design codes. In the first phase of the STELLA program, the sodium component test loop (hereafter called STELLA-1) was constructed at the KAERI site, and it has been used for performance tests of key sodium heat exchangers in PGSFR. Since this sodium test loop is basically for separate effects tests to verify the performance of key sodium components, the test database obtained from STELLA-1 has been used for the V and V of safety codes as well as heat exchanger design codes. The second phase of the program aiming at an integral effect test is called STELLA-2, which will be used for synthetic review of the key safety issues of PGSFR. The basic and detailed design phases of the STELLA-2 test facility are underway in accordance with the specific design requirements reflecting the whole design features of PGSFR. The facility installation is scheduled to be completed by 2018. Then the main experiments including the start-up tests will begin and the first integral effect test database will be constructed by the end of 2019. Based on the STELLA-2 platform, a simulation of the PGSFR transient will be made to evaluate the plant dynamic behaviors and demonstrate the decay heat removal performance. Multi-dimensional effects coming from a large sodium pool system will be identified as well. The test database obtained from the STELLA-2 experiment will be used for the validation of the safety analysis codes and other thermal hydraulics codes, and this project finally contributes to the specific design phase of PGSFR. This paper presents both the results of heat transfer tests for the key sodium heat exchangers using STELLA-1 and the first results of heat exchanger design codes V and V. The recent progress of the engineering design for the STELLA-2 test section is introduced and its specific design parameters are also presented in this paper with detailed evaluation results of their scaling distortions. A large-scale sodium thermal-hydraulic test program (STELLA) was introduced with the specific activities for separate and integral effects tests. The test database obtained from STELLA-1 was successfully used to validate both the heat exchanger design and safety analysis codes. Specific design features of the integral effects test facility (STELLA- 2) with a scaling ratio of 1/5 in length and 1/125 in volume were also presented. Validation of the STELLA-2 facility design is underway using system codes and CFD tools. Dedicated water-mockup experiments to verify the scaling design of key subsystems are currently being conducted as well. (authors)

42 ENGINEERING↗

Concept, implementation and commissioning of the automation system for the accelerator module test facility AMTF

The European XFEL project launched on June 5, 2007 will require about 103 accelerator modules as a main part of the XFEL linear accelerator. All superconducting components constituting the accelerator module like cavities and magnets have to be tested before the assembly. For the tests of the individual cavities and the complete modules an XFEL Accelerator Module Test Facility (AMTF) has been erected at DESY. The process control system EPICS (Experimental Physics and Industrial Control System) is used to control and operate the cryogenic plant and all its subcomponents. A complementary component of EPICS is the Open Source software suit CSS (Control System Studio). CSS is an integrated engineering, maintenance and operating tool for EPICS. CSS enables local and remote operating and monitoring of the complete system and thus represents the human machine interface. More than 250 PROFIBUS nodes work at the accelerator module test facility. DESY installed an extensive diagnostic and condition monitoring system. With these diagnostic tools it is possible to examine the correct installation and configuration of all PROFIBUS nodes in real time. The condition monitoring system based on FDT/DTM technology shows the state of the PROFIBUS devices at a glance. This information can be used for preventive maintenance which is mandatory for continuous operation of the AMTF facility. The poster will describe all steps form engineering to implementation and commissioning.

43 PARTICLE ACCELERATORS↗

Development of an Improved RELAP5-3D Model for the High Temperature Test Facility

High-temperature gas-cooled reactors (HTGRs) are rapidly approaching deployment. Confidence in transient analysis of these systems requires modeling and simulation tools that have been validated against data relevant to HTGR conditions. The High Temperature Test Facility (HTTF) is an integral effects thermal hydraulics test facility for prismatic HTGRs. In spring and summer of 2019, HTTF was used for a series of experiments that now serve as the basis for the Organization of Economic Cooperation and Development / Nuclear Energy Agency Thermal Hydraulic Code Validation Benchmark for High Temperature Gas-Cooled Reactors using HTTF Data (HTGR T/H Benchmark). Previous analyses as part of the HTGR T/H benchmark used a RELAP5-3D model developed at Idaho National Laboratory (INL) and demonstrated an ability to reproduce trends in the measured data but difficulties reproducing experimental values within their uncertainty. These difficulties were largely attributed to assumptions made during the development of the initial RELAP5-3D model, which predated the HTTF experiments. A significant cause of difficulty reproducing the measured temperatures may be the radial nodalization of the previous RELAP5-3D model. In this paper, we present a new RELAP5-3D model of HTTF with finer radial nodalization built to assess the impact of radial heat transfer. We describe the new model and compare it against the old one at full-power steady state and for the pressurized conduction cooldown (PCC) transient. These analyses are based on the code-to-code comparison exercise for the PCC problem of the HTGR T/H benchmark. We compare maximum block temperature as the primary figure of merit and include discussion on intracore natural circulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Beam Optics Measurements in Medium Energy Beam Transport at PIP-II Injector Test Facility

The Proton Improvement Plan-II Injector Test (PIP2IT) is an accelerator test facility under construction at Fermilab that will provide a platform to demonstrate critical technologies and concept of the front-end of the PIP-II linear accelerator (linac). The PIP2IT warm front-end comprises a H⁻ ion source capable of delivering 15 mA, 30 keV DC or pulsed beam, a Low Energy Beam Transport (LEBT), a 162.5 MHz, CW Radio Frequency Quadrupole (RFQ) that accelerates the beam to 2.1 MeV and, a 14 m medium energy beam transport (MEBT). Presently, beamline up to the MEBT has been commissioned and operates routinely at the PIP2IT facility. In this paper, we discuss beam measurements performed at the MEBT to analyze beam emittance and its RMS sizes along the MEBT. In addition, beam based calibration of the beamline elements using differential trajectory measurement is also presented.

43 PARTICLE ACCELERATORS↗

FNAL test facility

Report on the status of superconducting magnet test facility at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗