Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal mass”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Testing of fiber optic based sensors for advanced reactors in the Texas A&M University TRIGA reactor

An Optical Fiber Based Gamma Thermometer has been developed and tested at the Texas A&M University reactor as well as the Ohio State Research Reactor. This sensor technology provides temperature measurement of a thermal mass undergoing gamma heating, from which the gamma flux along the length of the sensor may be calculated. The gamma flux data from an array of OFBGTs could allow the determination of local power density within a nuclear reactor core in three dimensions. The design of the sensor makes use of optical fiber as a truly distributed temperature sensor with a spatial resolution less than 1mm and temperature accuracy of ±1°C. The testing program showed that the system provided the expected temperature data for each location. Overall, this sensor technology shows promise for current Light Water Reactors as well as advanced nuclear reactors by providing an unparalleled level of precision in reactor power measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A dynamic 2D Borehole Thermal Energy Storage (BTES) model for enhanced computational efficiency

Progressing toward a future increasingly reliant on renewable energy sources, the development of effective, durable energy storage solutions becomes essential to balance supply and demand fluctuations. Borehole Thermal Energy Storage (BTES) is a long-duration thermal energy storage technology that captures excess heat generated from renewable energy sources and stores it underground for later use, enabling the efficient utilization of sustainable energy. This approach is particularly valuable in district energy networks when integrated with Ground Source Heat Pumps (GSHP) to provide stable heating and cooling. However, traditional three-dimensional (3D) numerical models of BTES systems demand extensive computational resources, limiting their practicality for real-time and large-scale applications. This study introduces a novel two-dimensional (2D) modeling approach that reduces computational costs while maintaining high accuracy. By employing a radial ring-based discretization method, the model simulates heat injection, retention, and retrieval dynamics over seasonal cycles. A new thermal-mass weighted-average temperature parameter is introduced to evaluate the performance of BTES systems. Model validation against FEFLOW simulations demonstrates a 17-fold improvement in computational speed compared to traditional Computational Fluid Dynamics (CFD) models while achieving a mean absolute percentage error (MAPE) of 2 % during charging and 4 % during discharging. Additionally, a trade-off analysis between computational efficiency and accuracy is conducted, ensuring the model's applicability for real-world scenarios. The findings of this research contribute to the development of computationally efficient BTES models, facilitating better optimization, control, and integration into renewable energy systems. This work provides a foundation for further studies in techno-economic analysis, multi-year performance evaluation, and real-time operational strategies for BTES applications, supporting a more sustainable energy future.

2D modeling↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗

Design Overview of a High-Pressure Helium Flow Visualization Apparatus for Blanket Cooling Studies

Cooling of the fusion blanket first wall remains a significant challenge given the adverse conditions of heat and particle flux encountered near the plasma. Helium emerges as an attractive cooling candidate because of its chemical and neutronic inertness and separability from hydrogenic species (e.g. tritium). Because of the low thermal mass of helium, optimization of these coolant channels is warranted to provide high heat transfer performance at low pumping costs. Increasingly, computational fluid dynamics (CFD) simulations are employed to model and optimize these flow channels, and accompanying experimental data are needed to validate the predictions of these models. To provide the aforementioned experimental data, a high-pressure helium flow visualization upgrade has been designed for the Helium Flow Loop Experiment facility. This apparatus was built to American Society of Mechanical Engineers boiler and pressure vessel standards to withstand operating pressure of 4 MPa and mated to high-pressure glass windows. Seedless flow visualization is performed via high-speed background oriented schlieren (BOS), with image correlation used for time-resolved two-dimensional velocimetry at frequencies in excess of 60 kHz. Rectangular flow channel test articles are additively manufactured via laser powder bed fusion and installed into this visualization apparatus, with one-sided heating supplied by resistive heaters. In conclusion, the chosen test geometries were informed by prior CFD simulations, and the helium flow structures observed via BOS (detachment, recirculation, etc.) will be used for the validation of these accompanying models, in support of the design and optimization of blanket cooling channel configurations.

Helium flow↗

Simulation of Channel Flow with Square Ribs for Blanket First-Wall Cooling: Geometry-Specific Tuning of k-ω Model Using Adjoint Method

Cooling of the plasma-facing first wall is challenging in the design of blanket components because of the high heat flux (on the order of 𝑀𝑊/𝑚2) from the plasma, especially when a low thermal mass medium like helium is chosen as the coolant. Therefore, heat transfer enhancement in which the convective heat transfer rate is augmented by the addition of turbulence-promoting structures becomes a key initiative for providing sufficient cooling capability with helium. Previously, computational fluid dynamics simulations had been performed on pipe flows with different transverse and longitudinal ribbed geometries at Oak Ridge National Laboratory to compare the enhancement performance among different ribbed geometries. Rib shape morphing had been conducted to obtain an optimized rib profile. In the work presented here, the adjoint method is adopted in the ANSYS Fluent solver for turbulence model augmentation, and the Generalized k-ω (GEKO) turbulence model is employed because of its ability of tuning the turbulence model. The Nusselt number and pressure drop obtained from the channel flow with bottom ribbed wall experiments are used as the targets. Sensitivity analysis provides information as guidance to improve the turbulence model accuracy. The augmented GEKO model is tuned for the studied ribbed channel geometry and flow conditions, providing improved predictive accuracy within this context. Extension to other configurations offers potential but may require additional tuning and validation.

Xu, Tracy [ORNL] (ORCID:0009000193700887)↗

Bottomonium suppression from the three-loop QCD potential

We compute the suppression of bottomonium in the quark-gluon plasma using the three-loop QCD static potential. The potential describes the spin-averaged bottomonium spectrum below threshold with a less than 1% error. Within potential nonrelativistic quantum chromodynamics and an open quantum systems framework, we compute the evolution of the bottomonium density matrix. The values of the quarkonium transport coefficients are obtained from lattice QCD measurements of the bottomonium in-medium width and thermal mass shift; we additionally include for the first time a vacuum contribution to the dispersive coefficient γ . Using the three-loop potential and the values of the heavy quarkonium transport coefficients, we find that the resulting bottomonium nuclear modification factor is consistent with experimental observations, while at the same time reproducing the lattice measurements of the in-medium width. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

QLBT: a linear Boltzmann transport model for heavy quarks in a quark-gluon plasma of quasi-particles

Abstract We develop a new heavy quark transport model, QLBT, to simulate the dynamical propagation of heavy quarks inside the quark-gluon plasma (QGP) created in relativistic heavy-ion collisions. Our QLBT model is based on the linear Boltzmann transport (LBT) model with the ideal QGP replaced by a collection of quasi-particles to account for the non-perturbative interactions among quarks and gluons of the hot QGP. The thermal masses of quasi-particles are fitted to the equation of state from lattice QCD simulations using the Bayesian statistical analysis method. Combining QLBT with our advanced hybrid fragmentation-coalescence hadronization approach, we calculate the nuclear modification factor $$R_\mathrm {AA}$$ R AA and the elliptic flow $$v_2$$ v 2 of D mesons at the Relativistic Heavy-Ion Collider and the Large Hadron Collider. By comparing our QLBT calculation to the experimental data on the D meson $$R_\mathrm {AA}$$ R AA and $$v_2$$ v 2 , we extract the heavy quark transport parameter $$\hat{q}$$ q ^ and diffusion coefficient $$D_\mathrm {s}$$ D s in the temperature range of $$1-4~T_\mathrm {c}$$ 1 - 4 T c , and compare them with the lattice QCD results and other phenomenological studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A NUMERICAL STUDY OF HEAT TRANSFER IN THE FUEL CELL OF A SOLID OXIDE FUEL CELL-COMBUSTOR

A Solid Oxide Fuel Cell-Combustor (SOFC-C) concept was proposed to address many challenges a traditional fuel cell-gas turbine hybrid system (FC-GT) will have in aerospace applications. By taking advantage of the temperature rise during compression and the combustion of anode off-gas, the SOFC-C eliminates the recuperating heat exchanger usually required for cathode flows, greatly reducing the size and weight (thermal mass) of the system. The fuel cell is one of the key parts of the SOFC-C, so it is desired to understand the heat transfer in the fuel cell. In present work, a computational fluid dynamic (CFD) model was developed to reveal the gas flow and heat transfer in the fuel cell of the SOFC-C. The model includes not only convection heat transfer, but also includes the radiation heat transfer. The modeling results help to optimize the SOFC-C design.

Zhang, Mingkan↗

Field Performance of Commercial Building Load Flexibility Using Model Predictive Control

Model Predictive Control (MPC) applied to buildings is starting to see some commercial adoption by companies. However, it is hard to estimate if relative energy cost savings are enough to justify the cost of MPC implementation with few reported demonstrations. In small commercial and residential buildings, a one size-fits-all solution can help reduce implementation costs, while in very large buildings or districts the potential energy cost savings magnitude can cover more tailored solutions. This estimation becomes harder for medium to large commercial buildings, where a one-size-fits-all solution cannot be adopted and potential energy cost savings might not be sufficient to cover a tailored solution. Therefore, value propositions in addition to energy efficiency alone can make MPC technology more attractive through additional energy cost savings. One such value proposition is load shifting in response to dynamic electricity prices. On this aspect, MPC is a key technology to unlock building thermal mass for energy flexibility in response to electric grid conditions. This study shows the experimental results of MPC control of an office building in Berkeley, where different dynamic electricity price profiles were used in the MPC objective function to shift the building load and to calculate hypothetical electricity costs. Results show potential 50% cost savings with respect to the existing controller with the dynamic price scenario.

Zanetti, Ettore↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tailoring Charge Transport and Magnetism in Complex Half-Heusler/Full-Heusler Nanocomposites (Final Report)

This project exploits (1) the facile co-crystallization of the half-Heusler (HH) and full-Heusler (FH) structures, (2) the high coherency and stability of the HH/FH interfaces, and (3) the solid-state inter-conversion between HH and FH structures through local atomic diffusion, to investigate, for selected compositions of the HH and FH phases, the effect of size, dimensionality, dispersion and volume fraction of FH nanostructures on the electronic, phonon and magnetic behavior of the resulting HH/FH nanocomposites. Our goal is to identify and control key material and growth parameters governing phase formation, microstructural evolution, and to understand the mechanism by which these changes of the internal structure modify the material’s performance. To elucidate the mechanism by which the FH nanostructures regulate electronic charge transport and induce ferromagnetism within non-magnetic and magnetic semiconducting HH matrices, suitable series of HH/0D-FH and HH/2D-FH nanocomposites will be fabricated using synthesis conditions suggested by theoretical calculations of the formation energy and stability of various FH phases (varying M) in HH matrices with known chemical composition. The structure of the HH/FH interfaces (size, chemical composition, volume fraction and dispersion) will be investigated along with the evaluation of the electronic (carrier density, mobility, thermopower, electrical conductivity, effective mass), thermal and magnetic (susceptibility, magnetization etc.) properties of the resulting HH/FH nanocomposites.

36 MATERIALS SCIENCE↗

Heating and Cooling Energy Modeling of 3D-Printed Concrete Construction of Residential Buildings [Slides]

3D printed concrete construction (C3DP) is an emerging technology that comes with the associated benefits of high thermal mass walls. We investigated using BEopt software the heating and cooling energy use of a single story C3DP-constructed house. We then compared the heating/cooling energy use of the C3DP house against the corresponding energy use in a traditional timber (wood) frame construction (WFC), as well as a concrete masonry unit (CMU) construction. Both peak energy use for heating and cooling (Btu), as well as base energy use for both heating and cooling (MMBtu/yr) of the C3DP design were compared against the WFC and CMU baseline construction of identical geometries and orientations across all eight climate zones defined in the International Energy Conservation Code (IECC). The BEopt models for all three constructions (C3DP, WFC, and CMU) were built to comply with the 2018 IECC code. Results indicate that C3DP construction has significant heating and cooling energy benefits in certain climate zones, with the highest peak cooling energy savings (9% compared to WFC, and 5% compared to CMU) in the IECC Climate Zone 1 in the month of July. The peak heating and cooling energy demand reduction of C3DP were found to be more significant than the base heating and cooling energy demand in all IECC climate zones. The 2018 IECC compliance-related U-Factor adjustments of all models also resulted in more peak energy savings of the C3DP design in the cooling-dominated climate zones (climate zones 1 and 2), moderate energy savings in moderate climate zones (climate zones 3, 4, and 6), and little to no change in energy savings in very cold climates (climate zones 7 and 8).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CRADA Number NFE-19-07846 with Grid Fruit, LLC (CRADA Final Report)

Cooperative Research and Development Agreement (CRADA) NFE-19-07846 between Oak Ridge National Laboratory (ORNL) and Grid Fruit, LLC (Grid Fruit) focused on simulating, monitoring, and adjusting controls of commercial refrigerator and freezer systems to provide load flexibility and demand response services from these machines. Viewing these medium and low-temp coolers as thermal masses, the volumes of chilled air in these coolers make them time-shiftable loads ripe for deployment at optimal times. Grid Fruit is a startup company developing methods to schedule the chilling cycles (e.g., in “build load” and “shed load” grid events) to provide energy efficiency, peak shifting, and other benefits both to the grid and the broader environment. These benefits can be magnified by coordinating chillers with HVAC, lights, computers, and other loads. Grid Fruit completed simulations and then selected and ordered controls hardware to prove the technology were successful, but the diversity of chiller models in the field without digital controls, as well as limited market demand at present, make further exploration necessary before commercialization.

42 ENGINEERING↗

Evaluation of Envelope Energy in a High-Performance Manufactured Home in California

There are important applications for a robust energy model for new construction manufactured homes that can characterize the individual performance of the opaque wall and ceiling components of the building envelope. The efficacy of different insulation materials can be assessed with the confidence that modeled performance will closely predict installed performance. This study uses careful calibration of a standard energy model with a short-term co-heating test in an installed manufactured home to de-aggregate the contributions of planar wall sections from overall building envelope thermal resistance. The methodology takes into account thermal mass effects, solar gains, and physical adjustments to the structure to achieve successful calibration and to inform adjustments to the test procedure for future study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improved melt model for power flow

Accelerators that drive z-pinch experiments transport current densities in excess of 1 MA/cm 2 in order to melt or ionize the target and implode it on axis. These high current densities stress the transmission lines upstream from the target, where rapid electrode heating causes plasma formation, melt, and possibly vaporization. These plasmas negatively impact accelerator efficiency by diverting some portion of the current away from the target, referred to as “current loss”. Simulations that are able to reproduce this behavior may be applied to improving the efficiency of existing accelerators and to designing systems operating at ever higher current densities. The relativistic particle-in-cell code CHICAGO ® is the primary code for modeling power flow on Sandia National Laboratories’ Z accelerator. We report here on new algorithms that incorporate vaporization and melt into the standard power-flow simulation framework. Taking a hybrid approach, the CHICAGO® kinetic/multi-fluid treatment has been expanded to include vaporization while the quasi-neutral equation-of-motion has been updated for melt at high current-densities. For vaporization, a new one-dimensional substrate model provides a more accurate calculation of electrode thermal, mass, and magnetic field diffusion as well as a means of emitting absorbed contaminants and vaporized metal ions. A quasi-fluid model has been implemented expressly to mimic the motion of imploding liners for accurate inductance histories. For melt, a multi-ion Hall-MHD option has been implemented and benchmarked against Alegra MHD. This new model is described with sufficient detail to reproduce these algorithms in any hybrid kinetic code. Physics results from the new code are also presented. A CHICAGO ® Hall-MHD simulation of a radial transmission line demonstrates that Hall physics, not included in Alegra, has no significant impact on the diffusion of electrode material. When surface contaminant desorption is mocked in as a hydrogen surface plasma, both the surface and bulk-material plasmas largely compress under the influence of the j × B force. Similar results are seen in Alegra, which also shows magnetic and material diffusion scaling with peak current. Test vaporization simulations using MagLIF and a power-flow experimental geometry show Fe + ions diffuse only a few hundred µm from the electrodes, so present models of Z power flow remain valid.

43 PARTICLE ACCELERATORS↗

Predicting Building Envelope Construction from In-Situ Thermal Testing

When embarking on a retrofit of a building envelope, it is critical to understand the composition of its assembly. This practice is currently done by destructive and invasive material testing or demolition, which is sometimes not possible when in historic or protected buildings. To address this problem, in-situ thermal testing can be utilized along with machine learning classification algorithms to infer the composition of an assembly. In this paper, a proof-of-concept K-nearest neighbors classification model is developed to classify assembly composition from effective thermal resistance, effective thermal mass, and assembly cladding. This model was trained and tested utilizing a synthetic dataset producing an F1-score of 94.6%. This model was also validated with experimental data from a 100-year old wall assembly, confirming the model’s real-world validity. The paper presents a framework for inferring as-built envelope assemblies, all without having to damage or disturb the building and its occupants.

Pilet, Tyler J.↗

Novel Relaxation Time Approximation: A Consistent Calculation of Transport Coefficients with QCD-inspired Relaxation Times

We use a novel formulation of the relaxation time approximation to consistently calculate the bulk and shear viscosity coefficients using QCDinspired energy-dependent relaxation times and phenomenological thermal masses obtained from fits to lattice QCD thermodynamics. The matching conditions are conveniently chosen to simplify the computations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal testing of the Ranger Block III SPACECRAFT in the JPL 25 ft. space simulator

In January, 1964, a test program was begun on the thermal design of the Ranger Block III Spacecraft. The tests were performed i n the newly operational JPL 25' Space Simulator over a period of 6 months . The objectives of these tests were two-fold: A. To evaluate the 25' Space Simulator as a facility for proving the thermal design of spacecrafts, and B. To verify .the thermal design of the Ranger Block III spacecraft. These two objectives are complimentary in the test series performed and are difficult to separate into distinct categories. An important part of the first objective was to learn what type of test preparation, instrumentation, and analysis was required for the meaningful evaluation of test data from the 25' Space Simulator tests. Although some experience had been gained in testing of components and incomplete spacecrafts in smaller solar simulation chambers during the early part of the Ranger program, we knew little about testing of a complete spacecraft in the 25' Space Simulator when this test program began. Test analysis requires that the energy absorbed by various spacecraft components be known. This requires a knowledge of the area of solar absorption or sunlit area, the solar energy flux density on the area, and the effective absorptance of that area. Most of the problems encountered were associated with the determination of the last two quantities since the sunlit area may be obtained directly by inspection of spacecraft surfaces. This paper will present a discussion of our experiences during the Ranger Block III thermal test series on the Thermal Test Model (TCM). The TCM was thermally equivalent to the flight type Ranger spacecraft except for the lack of an antenna dish and solar panels. Flight type structural hardware was used with surface finishes equivalent to those of the flight spacecraft. Aluminum blocks simulated the spacecraft electronics thermal masses with resistance heaters simulating the electronic power dissipation. The discussion will be presented in a semi-chronological order and will be divided into the following areas: 1. Determination of solar simulation flux density on spacecraft surfaces. 2. Problems related to decollimation of the solar simulation source. 3. Determination of effective absorptance in the solar simulation spectrum.

SPACE SIMULATOR↗